{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T20:20:22Z","timestamp":1767990022661,"version":"3.49.0"},"reference-count":33,"publisher":"Cambridge University Press (CUP)","issue":"10","license":[{"start":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["cambridge.org"],"crossmark-restriction":true},"short-container-title":["Cardiol Young"],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S1047951122003511_as1\"><jats:title>Objective:<\/jats:title><jats:p>The purpose of this study is to assess the feasibility, effectivity, and safety of a novel self-expandable valve system, Pulsta\u00ae transcatheter heart valve in patients with tetralogy of fallot and severe pulmonary regurgitation after transannular patch repair.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951122003511_as2\"><jats:title>Background:<\/jats:title><jats:p>Severe pulmonary regurgitation after tetralogy of fallot repair is a life-threatening problem and should be treated by pulmonary valve implantation. Although percutaneous pulmonary valve implantation has been ever increasingly used for this purpose, available balloon-expandable valves have limitations and cannot be used by most patients. Pulsta\u00ae transcatheter heart valve is a new self-expandable valve system and offers a new solution to be used in patients with different types of native right ventricular outflow tract geometry.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951122003511_as3\"><jats:title>Patients and Methods:<\/jats:title><jats:p>Ten patients with severe regurgitation after tetralogy of fallot repair with a transannular patch have been enrolled in the study according to echocardiographic examination. MRI was used in asymptomatic patients to delineate the indication and the right ventricular outflow tract geometry. Pulsta\u00ae transcatheter heart valve implantation was performed in ten patients, and preprocedural, procedure, and 6 months follow-up findings of the patients were evaluated.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951122003511_as4\"><jats:title>Results:<\/jats:title><jats:p>Pulsta\u00ae pulmonary valve implantation was performed in ten patients successfully without any severe complications. Valve functions were perfect in six of ten patients, while the others had insignificant regurgitation by echocardiographic examination at the end of 6 months follow-up.<\/jats:p><\/jats:sec><jats:sec id=\"S1047951122003511_as5\"><jats:title>Conclusions:<\/jats:title><jats:p>This study showed that Pulsta\u00ae transcatheter heart valve is a feasible, effective, and safe method in the treatment of severe pulmonary regurgitation due to transannular patch repair in patients with tetralogy of fallot.<\/jats:p><\/jats:sec>","DOI":"10.1017\/s1047951122003511","type":"journal-article","created":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T05:37:57Z","timestamp":1668577077000},"page":"1926-1934","update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":8,"title":["Early results of Pulsta\u00ae transcatheter heart valve in patients with enlarged right ventricular outflow tract and severe pulmonary regurgitation due to transannular patch"],"prefix":"10.1017","volume":"33","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1041-6299","authenticated-orcid":false,"given":"Ender","family":"Odemis","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2518-2002","authenticated-orcid":false,"given":"Irem","family":"Yenidogan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mete Han","family":"Kizilkaya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2022,11,16]]},"reference":[{"key":"S1047951122003511_ref6","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.118.006494"},{"key":"S1047951122003511_ref11","doi-asserted-by":"publisher","DOI":"10.4070\/kcj.2019.0291"},{"key":"S1047951122003511_ref28","doi-asserted-by":"publisher","DOI":"10.4244\/EIJV5I6A122"},{"key":"S1047951122003511_ref25","doi-asserted-by":"publisher","DOI":"10.1007\/s40746-020-00209-0"},{"key":"S1047951122003511_ref10","doi-asserted-by":"publisher","DOI":"10.12688\/f1000research.17174.1"},{"key":"S1047951122003511_ref19","doi-asserted-by":"publisher","DOI":"10.1016\/j.athoracsur.2015.02.124"},{"key":"S1047951122003511_ref1","volume-title":"Seminars in thoracic and cardiovascular surgery","volume":"17","author":"Cheung","year":"2005"},{"key":"S1047951122003511_ref21","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.25096"},{"key":"S1047951122003511_ref13","doi-asserted-by":"publisher","DOI":"10.1111\/joic.12443"},{"key":"S1047951122003511_ref20","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2008.07.057"},{"key":"S1047951122003511_ref22","first-page":"96","article-title":"Implantation of the Edwards SAPIEN XT and SAPIEN 3 valves for pulmonary position in enlarged native right ventricular outflow tract","volume":"25","author":"G\u00fczelta\u015f","year":"2021","journal-title":"Anatol J Cardiol"},{"key":"S1047951122003511_ref3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2015.09.055"},{"key":"S1047951122003511_ref16","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.24594"},{"key":"S1047951122003511_ref30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2021.01.046"},{"key":"S1047951122003511_ref26","doi-asserted-by":"publisher","DOI":"10.1016\/j.pcad.2018.09.003"},{"key":"S1047951122003511_ref15","doi-asserted-by":"publisher","DOI":"10.1016\/j.acvd.2014.07.045"},{"key":"S1047951122003511_ref31","doi-asserted-by":"publisher","DOI":"10.4244\/EIJ-D-18-00299"},{"key":"S1047951122003511_ref7","doi-asserted-by":"publisher","DOI":"10.4070\/kcj.2019.0291"},{"key":"S1047951122003511_ref12","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2017.11.091"},{"key":"S1047951122003511_ref18","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2004.10.027"},{"key":"S1047951122003511_ref2","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehi091"},{"key":"S1047951122003511_ref4","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.27581"},{"key":"S1047951122003511_ref8","doi-asserted-by":"publisher","DOI":"10.3390\/jcm9092769"},{"key":"S1047951122003511_ref24","doi-asserted-by":"publisher","DOI":"10.32604\/CHD.2021.015222"},{"key":"S1047951122003511_ref23","first-page":"1","article-title":"First experiences with Myval Transcatheter Heart Valve System in the treatment of severe pulmonary regurgitation in native right ventricular outflow tract and conduit dysfunction","volume":"32","author":"Odemis","year":"2021","journal-title":"Cardiol Young"},{"key":"S1047951122003511_ref14","doi-asserted-by":"publisher","DOI":"10.1093\/ejcts\/ezr130"},{"key":"S1047951122003511_ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejcts.2007.12.034"},{"key":"S1047951122003511_ref29","first-page":"1763","article-title":"Harmony feasibility trial: acute and short-term outcomes with a self-expanding transcatheter pulmonary valve","volume":"10","author":"Bergersen","year":"2017","journal-title":"JACC: Cardiovasc Interv"},{"key":"S1047951122003511_ref9","volume-title":"Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual","volume":"9","author":"Geva","year":"2006"},{"key":"S1047951122003511_ref5","doi-asserted-by":"publisher","DOI":"10.1007\/s11886-018-0966-y"},{"key":"S1047951122003511_ref27","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2020.1775578"},{"key":"S1047951122003511_ref32","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.29865"},{"key":"S1047951122003511_ref33","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.27932"}],"updated-by":[{"DOI":"10.1017\/s1047951122003870","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2022,11,16]],"date-time":"2022-11-16T00:00:00Z","timestamp":1668556800000}}],"container-title":["Cardiology in the Young"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S1047951122003511","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,11]],"date-time":"2023-10-11T10:17:29Z","timestamp":1697019449000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S1047951122003511\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,16]]},"references-count":33,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2023,10]]}},"alternative-id":["S1047951122003511"],"URL":"https:\/\/doi.org\/10.1017\/s1047951122003511","relation":{"correction":[{"id-type":"doi","id":"10.1017\/S1047951122003870","asserted-by":"object"}]},"ISSN":["1047-9511","1467-1107"],"issn-type":[{"value":"1047-9511","type":"print"},{"value":"1467-1107","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,16]]},"assertion":[{"value":"\u00a9 The Author(s), 2022. Published by Cambridge University Press","name":"copyright","label":"Copyright","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}},{"value":"This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http:\/\/creativecommons.org\/licenses\/by\/4.0\/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.","name":"license","label":"License","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}]}}