{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,1,28]],"date-time":"2025-01-28T05:31:38Z","timestamp":1738042298759,"version":"3.33.0"},"reference-count":8,"publisher":"Cambridge University Press (CUP)","issue":"1","license":[{"start":{"date-parts":[[2023,12,11]],"date-time":"2023-12-11T00:00:00Z","timestamp":1702252800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":["cambridge.org"],"crossmark-restriction":true},"short-container-title":["Cardiol Young"],"published-print":{"date-parts":[[2024,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Amplatzer Vascular Plug IV (Abbott, USA) is usually used for the occlusion of abnormal tortuous vessels and has not been tried for the transcatheter closure of perimembranous ventricular septal defects with wind-sock morphology. Here, we report on three successful cases of perimembranous ventricular septal defect transcatheter closure using Amplatzer Vascular Plug IV. We did not observe residual shunting or new onset of complications during follow up. These preliminary positive results advocate the application and suitability of Amplatzer Vascular Plug IV for closing wind-sock-like perimembranous ventricular septal defects.<\/jats:p>","DOI":"10.1017\/s1047951123004055","type":"journal-article","created":{"date-parts":[[2023,12,11]],"date-time":"2023-12-11T10:19:15Z","timestamp":1702289955000},"page":"228-231","update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":0,"title":["Preliminary experience with transcatheter closure of wind-sock-like perimembranous ventricular septal defects using Amplatzer Vascular Plug IV devices"],"prefix":"10.1017","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7891-8060","authenticated-orcid":false,"given":"Ming Chern","family":"Leong","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin Yi","family":"Hoo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mazeni","family":"Alwi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2023,12,11]]},"reference":[{"key":"S1047951123004055_ref8","first-page":"844","article-title":"The amplatzer vascular plug 4: preliminary experience","volume":"33","author":"Ferro","year":"2009","journal-title":"J Vasc Interv Radiol"},{"key":"S1047951123004055_ref6","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1007\/s00246-013-0823-0","article-title":"Perventricular closure of perimembranous ventricular septal defects using the concentric occluder device","volume":"35","author":"Wang","year":"2014","journal-title":"Pediatr Cardiol"},{"key":"S1047951123004055_ref3","doi-asserted-by":"crossref","first-page":"128","DOI":"10.3389\/fped.2018.00128","article-title":"Long-term outcome of transcatheter device closure of perimembranous ventricular septal defects","volume":"6","author":"Mandal","year":"2018","journal-title":"Front Pediatr"},{"key":"S1047951123004055_ref7","doi-asserted-by":"crossref","first-page":"E295","DOI":"10.1002\/ccd.28678","article-title":"Percutaneous closure of restrictive-type perimembranous ventricular septal defect using the new KONAR multifunctional occluder: midterm outcomes of the first middle-eastern experience","volume":"96","author":"Haddad","year":"2020","journal-title":"Catheter Cardiovasc Interv"},{"key":"S1047951123004055_ref2","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1016\/j.jacc.2014.01.008","article-title":"Transcatheter versus surgical closure of perimembranous ventricular septal defects in children: a randomized controlled trial","volume":"63","author":"Yang","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"S1047951123004055_ref1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.120.020417"},{"key":"S1047951123004055_ref5","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1017\/S1047951115002206","article-title":"Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer vascular plug-II","volume":"26","author":"Hua","year":"2016","journal-title":"Cardiol Young"},{"key":"S1047951123004055_ref4","doi-asserted-by":"crossref","first-page":"401","DOI":"10.33963\/KP.15762","article-title":"Efficacy and safety of the Amplatzer Duct Occluder II for ventricular septal defect closure: a meta-analysis","volume":"79","author":"Cen","year":"2021","journal-title":"Kardiol Pol"}],"container-title":["Cardiology in the Young"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S1047951123004055","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,27]],"date-time":"2025-01-27T12:49:13Z","timestamp":1737982153000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S1047951123004055\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,11]]},"references-count":8,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2024,1]]}},"alternative-id":["S1047951123004055"],"URL":"https:\/\/doi.org\/10.1017\/s1047951123004055","relation":{},"ISSN":["1047-9511","1467-1107"],"issn-type":[{"type":"print","value":"1047-9511"},{"type":"electronic","value":"1467-1107"}],"subject":[],"published":{"date-parts":[[2023,12,11]]},"assertion":[{"value":"\u00a9 The Author(s), 2023. Published by Cambridge University Press","name":"copyright","label":"Copyright","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}}]}}