{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T21:08:58Z","timestamp":1777410538955,"version":"3.51.4"},"reference-count":15,"publisher":"Cambridge University Press (CUP)","issue":"2","license":[{"start":{"date-parts":[[2024,1,3]],"date-time":"2024-01-03T00:00:00Z","timestamp":1704240000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":["cambridge.org"],"crossmark-restriction":true},"short-container-title":["Cardiol Young"],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>We report on a 6-month-old infant (6 Kg\/ 64 cm) with perimembranous ventricular septal defect (absent sub-aortic rim, 10 mm left ventricular entry, and 4 and 6 mm right ventricular exists) and successful retrograde closure using an 8x6 mm KONAR-MF\u2122 VSD occluder (Lifetech, China). Immediate and 48 hours post-procedure ultrasounds showed an accurately positioned device and two jets of mild-to-moderate residual shunts. At the 2-week follow-up, the device did not change position and the shunt was stable and intra-prosthetic. The scheduled 3-month follow-up was skipped for familial reasons. The patient came back without alarming symptoms for the regular 6-month follow-up, and the device was found embolised to the left pulmonary artery. The device was retrieved surgically, and the defect was patch-closed with excellent outcomes. There was a pseudoaneurysm involving the tricuspid valve chordae and the device was endothelialized partially on one edge suggesting that embolization occurred somewhere between 3 months and 6 months post-operative. Defects with compromised anatomies should be closed surgically to avoid suboptimal results, especially in small infants.<\/jats:p>","DOI":"10.1017\/s104795112300433x","type":"journal-article","created":{"date-parts":[[2024,1,3]],"date-time":"2024-01-03T07:29:11Z","timestamp":1704266951000},"page":"455-458","update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":6,"title":["Word of caution: silent late device embolisation after perimembranous ventricular septal defect closure in a 6-Kg infant"],"prefix":"10.1017","volume":"34","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7605-4708","authenticated-orcid":false,"given":"Raymond N.","family":"Haddad","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8658-2686","authenticated-orcid":false,"given":"Zakhia","family":"Saliba","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2024,1,3]]},"reference":[{"key":"S104795112300433X_ref7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2007.03.068"},{"key":"S104795112300433X_ref3","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951121001578"},{"key":"S104795112300433X_ref2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-021-02638-6"},{"key":"S104795112300433X_ref10","doi-asserted-by":"publisher","DOI":"10.1111\/jocs.16441"},{"key":"S104795112300433X_ref12","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951121002985"},{"key":"S104795112300433X_ref11","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2023.1215397"},{"key":"S104795112300433X_ref9","doi-asserted-by":"publisher","DOI":"10.1016\/j.hlc.2014.03.029"},{"key":"S104795112300433X_ref4","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-023-03100-5"},{"key":"S104795112300433X_ref8","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijcard.2017.12.011"},{"key":"S104795112300433X_ref1","doi-asserted-by":"publisher","DOI":"10.1177\/2150135119825562"},{"key":"S104795112300433X_ref5","first-page":"4053","article-title":"Closure of transcatheter ventricular septal defect using lifetechTM konar-MF occluder in children weighing less than 10 kilograms: mid-term results, a tertiary single center experience","volume":"27","author":"Yildiz","year":"2023","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"S104795112300433X_ref13","doi-asserted-by":"publisher","DOI":"10.1016\/S0022-5223(98)70222-3"},{"key":"S104795112300433X_ref15","doi-asserted-by":"publisher","DOI":"10.1007\/s00392-009-0044-y"},{"key":"S104795112300433X_ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.ppedcard.2022.101489"},{"key":"S104795112300433X_ref6","doi-asserted-by":"publisher","DOI":"10.1002\/ccd.20659"}],"container-title":["Cardiology in the Young"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S104795112300433X","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,21]],"date-time":"2024-02-21T00:10:10Z","timestamp":1708474210000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S104795112300433X\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,3]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,2]]}},"alternative-id":["S104795112300433X"],"URL":"https:\/\/doi.org\/10.1017\/s104795112300433x","relation":{},"ISSN":["1047-9511","1467-1107"],"issn-type":[{"value":"1047-9511","type":"print"},{"value":"1467-1107","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,3]]},"assertion":[{"value":"\u00a9 The Author(s), 2024. Published by Cambridge University Press","name":"copyright","label":"Copyright","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}}]}}