{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T05:15:24Z","timestamp":1775798124032,"version":"3.50.1"},"reference-count":14,"publisher":"Cambridge University Press (CUP)","issue":"1","license":[{"start":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T00:00:00Z","timestamp":1769040000000},"content-version":"unspecified","delay-in-days":21,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":["cambridge.org"],"crossmark-restriction":true},"short-container-title":["Cardiol Young"],"published-print":{"date-parts":[[2026,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec id=\"S1047951125110986_as1\">\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Percutaneous device closure is the preferred method for closing patent ductus arteriosus (PDA), even in preterm infants. We report our experience using the new KONAR-MFO\u2122 ventricular septal defect occluder for transcatheter closure of preterm patent ductus arteriosus as an alternative device in resource-limited centres.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S1047951125110986_as2\">\n                    <jats:title>Methodology:<\/jats:title>\n                    <jats:p>Case 1: A preterm baby with Down\u2019s\u00a0syndrome and tracheobronchomalacia was born at 29 weeks, weighing 1.68 kg with multiple cardiac defects, including a 4 mm PDA and a 6 mm mid-muscular ventricular septal defect (VSD), stuck on a ventilator. Case 2: Another preterm baby born at 35 weeks, weighing 1.89 kg,\u00a0with anorectal malformation and a right inguinal hernia. The echocardiogram revealed a 4 mm PDA with severe PAH. In both cases, the patent ductus arteriosus was occluded using a 6 mm \u00d7 4 mm Konar MFO device on day 14 (case 1) and day 20 (case 2).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S1047951125110986_as3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The baby (case 1) was weaned off the ventilator and discharged on the 28th postnatal day at 2.09 kg. As for case 2, the baby was weaned off the ventilator within 2 days and discharged on day 30 at 2.23 kg. A follow-up echocardiogram of both cases confirmed a well-positioned device with no obstructions. At 18 months, in the follow-up, both babies were gaining weight and thriving.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S1047951125110986_as4\">\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The KONAR MFO device is a safe and effective option for patent ductus arteriosus closure in preterm infants, even in resource-limited settings. Its versatility accommodates various duct sizes and morphologies, and its self-expandable design ensures easy deployment, addressing the anatomical challenges often seen in preterm infants.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1017\/s1047951125110986","type":"journal-article","created":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T05:42:44Z","timestamp":1769060564000},"page":"119-125","update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":0,"title":["Preterm PDA Device closure using the KONAR MFO device in a resource-limited centre of North-East India: a Case series"],"prefix":"10.1017","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2620-2113","authenticated-orcid":false,"given":"Saurabhi","family":"Das","sequence":"first","affiliation":[{"name":"Health City Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2103-8660","authenticated-orcid":false,"given":"Shantanu","family":"Jain","sequence":"additional","affiliation":[{"name":"Health City Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0304-1751","authenticated-orcid":false,"given":"Mirza M.","family":"Kamran","sequence":"additional","affiliation":[{"name":"Metromed International Cardiac Centre"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sukanya","family":"Pathak","sequence":"additional","affiliation":[{"name":"Health City Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kangkan","family":"Sharma","sequence":"additional","affiliation":[{"name":"Health City Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Narendra","family":"Sharma","sequence":"additional","affiliation":[{"name":"Health City Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2026,1,22]]},"reference":[{"key":"S1047951125110986_ref6","doi-asserted-by":"publisher","DOI":"10.3109\/14767058.2014.880879"},{"key":"S1047951125110986_ref10","first-page":"100316","article-title":"Off-label use of Lifetech KONAR-MFTM ventricular septal defect occluder for large patent ductus arteriosus closure in <6 kg infants","volume":"7","author":"Gronier","year":"2022","journal-title":"Int J Cardiol Congenit Heart Dis"},{"key":"S1047951125110986_ref7","first-page":"1266","article-title":"Amplatzer Piccolo Occluder clinical trial for percutaneous closure of the patent ductus arteriosus in patients $700 grams","volume":"96","author":"Sathanandam","year":"2020","journal-title":"Cathet Cardiovasc Interv"},{"key":"S1047951125110986_ref9","first-page":"612","article-title":"Transcatheter closure of hemodynamic significant patent ductus arteriosus in 32 premature infants by Amplatzer ductal occluder additional size-ADOIIAS","volume":"90","author":"Morville","year":"2017","journal-title":"Cathet Cardiovasc Interv"},{"key":"S1047951125110986_ref3","first-page":"240","article-title":"A novel technique for transcatheter patent ductus arteriosus closure in extremely preterm infants using commercially available technology","volume":"85","author":"Zahn","year":"2015","journal-title":"Catheter Cardiovasc Interv"},{"key":"S1047951125110986_ref13","doi-asserted-by":"publisher","DOI":"10.3389\/fped.2021.700284"},{"key":"S1047951125110986_ref5","doi-asserted-by":"publisher","DOI":"10.1186\/1749-8090-7-129"},{"key":"S1047951125110986_ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2014.02.003"},{"key":"S1047951125110986_ref4","doi-asserted-by":"publisher","DOI":"10.1016\/S1875-9572(10)60030-7"},{"key":"S1047951125110986_ref8","first-page":"71","article-title":"Percutaneous closure of patent ductus arteriosus in premature infants: a French national survey","volume":"95","author":"Malekzadeh-Milani","year":"2020","journal-title":"Cathet Cardiovasc Interv"},{"key":"S1047951125110986_ref1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcin.2010.01.016"},{"key":"S1047951125110986_ref11","doi-asserted-by":"publisher","DOI":"10.4103\/apc.apc_49_22"},{"key":"S1047951125110986_ref12","doi-asserted-by":"publisher","DOI":"10.1017\/S1047951120002668"},{"key":"S1047951125110986_ref2","first-page":"409","article-title":"Echocardiographically guided catheter closure of arterial ducts in small preterm infants in the neonatal intensive care unit","volume":"77","author":"Bentham","year":"2011","journal-title":"Catheter Cardiovasc Interv"}],"container-title":["Cardiology in the Young"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S1047951125110986","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,10]],"date-time":"2026-04-10T04:38:41Z","timestamp":1775795921000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S1047951125110986\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2026,1]]}},"alternative-id":["S1047951125110986"],"URL":"https:\/\/doi.org\/10.1017\/s1047951125110986","relation":{},"ISSN":["1047-9511","1467-1107"],"issn-type":[{"value":"1047-9511","type":"print"},{"value":"1467-1107","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1]]},"assertion":[{"value":"\u00a9 The Author(s), 2026. Published by Cambridge University Press","name":"copyright","label":"Copyright","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}}]}}