{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T03:17:59Z","timestamp":1767151079804,"version":"build-2238731810"},"reference-count":17,"publisher":"Cambridge University Press (CUP)","issue":"1","license":[{"start":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T00:00:00Z","timestamp":1715904000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":["cambridge.org"],"crossmark-restriction":true},"short-container-title":["Prehosp. Disaster med."],"published-print":{"date-parts":[[2025,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec id=\"S1049023X24000426_as1\">\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Handheld ultrasound (US) devices have become increasingly popular since the early 2000s due to their portability and affordability compared to conventional devices. The Rapid Ultrasonography for Shock and Hypotension (RUSH) protocol, introduced in 2009, has shown promising accuracy rates when performed with handheld devices. However, there are limited data on the accuracy of such examinations performed in a moving ambulance. This study aimed to assess the feasibility and accuracy of the RUSH protocol performed by paramedics using handheld US devices in a moving ambulance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S1049023X24000426_as2\">\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The study aimed to examine the performability of the RUSH protocol with handheld US devices in a moving ambulance and to evaluate the accuracy of diagnostic views obtained within an appropriate time frame.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S1049023X24000426_as3\">\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A prospective study was conducted with paramedics who underwent theoretical and practical training in the RUSH protocol. The participants performed the protocol using a handheld US device in both stationary and moving ambulances. Various cardiac and abdominal views were obtained and evaluated for accuracy. The duration of the protocol performance was recorded for each participant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S1049023X24000426_as4\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Nine paramedics completed the study, with 18 performances each in both stationary and moving ambulance groups. The accuracy of diagnostic views obtained during the RUSH protocol did not significantly differ between the stationary and moving groups. However, the duration of protocol performance was significantly shorter in the moving group compared to the stationary group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S1049023X24000426_as5\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Paramedics demonstrated the ability to perform the RUSH protocol effectively using handheld US devices in both stationary and moving ambulances following standard theoretical and practical training. The findings suggest that ambulance movement does not significantly affect the accuracy of diagnostic views obtained during the protocol. Further studies with larger sample sizes are warranted to validate these findings and explore the potential benefits of prehospital US in dynamic environments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1017\/s1049023x24000426","type":"journal-article","created":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T04:12:00Z","timestamp":1715919120000},"page":"53-58","update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":0,"title":["Rapid Ultrasonography for Shock and Hypotension Protocol Performed using Handheld Ultrasound Devices by Paramedics in a Moving Ambulance: Evaluation of Image Accuracy and Time in Motion"],"prefix":"10.1017","volume":"40","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7517-8637","authenticated-orcid":false,"given":"Burcu","family":"Azapoglu Kaymak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0108-9855","authenticated-orcid":false,"given":"Merve","family":"Eksioglu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2024,5,17]]},"reference":[{"key":"S1049023X24000426_ref11","doi-asserted-by":"publisher","DOI":"10.1111\/j.1553-2712.2010.00755.x"},{"key":"S1049023X24000426_ref8","doi-asserted-by":"publisher","DOI":"10.1017\/S1049023X20001247"},{"key":"S1049023X24000426_ref13","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2007.01.023"},{"key":"S1049023X24000426_ref14","doi-asserted-by":"publisher","DOI":"10.1016\/j.jemermed.2012.07.092"},{"key":"S1049023X24000426_ref17","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajem.2013.11.008"},{"key":"S1049023X24000426_ref3","doi-asserted-by":"publisher","DOI":"10.1002\/emp2.12322"},{"key":"S1049023X24000426_ref15","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2010.096966"},{"key":"S1049023X24000426_ref6","doi-asserted-by":"publisher","DOI":"10.5505\/tjtes.2011.88557"},{"key":"S1049023X24000426_ref16","doi-asserted-by":"publisher","DOI":"10.1017\/S1049023X20001028"},{"key":"S1049023X24000426_ref5","doi-asserted-by":"publisher","DOI":"10.1016\/j.auec.2018.09.003"},{"key":"S1049023X24000426_ref2","doi-asserted-by":"publisher","DOI":"10.1186\/s12947-017-0105-8"},{"key":"S1049023X24000426_ref9","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics13223412"},{"key":"S1049023X24000426_ref12","doi-asserted-by":"publisher","DOI":"10.5811\/westjem.2020.12.49254"},{"key":"S1049023X24000426_ref1","doi-asserted-by":"publisher","DOI":"10.1007\/s00261-015-0406-z"},{"key":"S1049023X24000426_ref4","doi-asserted-by":"publisher","DOI":"10.1016\/j.emc.2009.09.010"},{"key":"S1049023X24000426_ref7","first-page":"37","article-title":"112 emergency medical service in the metropolis","volume":"77","author":"Karaku\u015f","year":"2014","journal-title":"J Istanb Fac Med."},{"key":"S1049023X24000426_ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.jemermed.2012.02.032"}],"updated-by":[{"DOI":"10.1017\/s1049023x25000147","type":"retraction","label":"Retraction","source":"retraction-watch","updated":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T00:00:00Z","timestamp":1742860800000},"record-id":"63149"},{"DOI":"10.1017\/s1049023x25000147","type":"retraction","label":"Retraction","source":"publisher","updated":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T00:00:00Z","timestamp":1715904000000}}],"container-title":["Prehospital and Disaster Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S1049023X24000426","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,25]],"date-time":"2025-03-25T08:31:33Z","timestamp":1742891493000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S1049023X24000426\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,17]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,2]]}},"alternative-id":["S1049023X24000426"],"URL":"https:\/\/doi.org\/10.1017\/s1049023x24000426","relation":{},"ISSN":["1049-023X","1945-1938"],"issn-type":[{"value":"1049-023X","type":"print"},{"value":"1945-1938","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,17]]},"assertion":[{"value":"\u00a9 The Author(s), 2024. Published by Cambridge University Press on behalf of World Association for Disaster and Emergency Medicine","name":"copyright","label":"Copyright","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}}]}}