{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T12:44:07Z","timestamp":1791895447117,"version":"4.3.4"},"reference-count":41,"publisher":"Cambridge University Press (CUP)","license":[{"start":{"date-parts":[[2021,11,29]],"date-time":"2021-11-29T00:00:00Z","timestamp":1638144000000},"content-version":"unspecified","delay-in-days":332,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003246","name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","doi-asserted-by":"publisher","award":["p16-28"],"award-info":[{"award-number":["p16-28"]}],"id":[{"id":"10.13039\/501100003246","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["cambridge.org"],"crossmark-restriction":true},"short-container-title":["Wearable Technol."],"published-print":{"date-parts":[[2021]]},"abstract":"<jats:title>Abstract<\/jats:title>\n\t  <jats:p>This article presents a novel smart sensor garment with integrated miniaturized inertial measurements units (IMUs) that can be used to monitor lower body kinematics during daily training activities, without the need of extensive technical assistance throughout the measurements. The smart sensor tights enclose five ultra-light sensor modules that measure linear accelerations, angular velocities, and the earth magnetic field in three directions. The modules are located at the pelvis, thighs, and shanks. The garment enables continuous measurement in the field at high sample rates (250\u00a0Hz) and the sensors have a large measurement range (32\u00a0g, 4,000\u00b0\/s). They are read out by a central processing unit through an SPI bus, and connected to a centralized battery in the waistband. A fully functioning prototype was built to perform validation studies in a lab setting and in a field setting. In the lab validation study, the IMU data (converted to limb orientation data) were compared with the kinematic data of an optoelectronic measurement system and good validity (CMCs &gt;0.8) was shown. In the field tests, participants experienced the tights as comfortable to wear and they did not feel restricted in their movements. These results show the potential of using the smart sensor tights on a regular base to derive lower limb kinematics in the field.<\/jats:p>","DOI":"10.1017\/wtc.2021.16","type":"journal-article","created":{"date-parts":[[2021,11,29]],"date-time":"2021-11-29T11:27:21Z","timestamp":1638185241000},"update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":14,"title":["Smart sensor tights: Movement tracking of the lower limbs in football"],"prefix":"10.1017","volume":"2","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2838-7799","authenticated-orcid":false,"given":"Annemarijn","family":"Steijlen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bastiaan","family":"Burgers","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erik","family":"Wilmes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeroen","family":"Bastemeijer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bram","family":"Bastiaansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"French","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andre","family":"Bossche","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaspar","family":"Jansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2021,11,29]]},"reference":[{"key":"S2631717621000165_r2","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2017.2786587"},{"key":"S2631717621000165_r12","first-page":"232","article-title":"Wearing electronic performance and tracking system devices in association football: Potential injury scenarios and associated impact energies","volume":"2","author":"Dunn","year":"2018","journal-title":"Multidisciplinary Digital Publishing Institute Proceedings"},{"key":"S2631717621000165_r13","doi-asserted-by":"publisher","DOI":"10.1177\/0363546510395879"},{"key":"S2631717621000165_r20","doi-asserted-by":"publisher","DOI":"10.1002\/admt.201900176"},{"key":"S2631717621000165_r16","doi-asserted-by":"publisher","DOI":"10.1016\/j.jss.2016.04.063"},{"key":"S2631717621000165_r24","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2005.11.011"},{"key":"S2631717621000165_r39","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2015.7319695"},{"key":"S2631717621000165_r8","doi-asserted-by":"publisher","DOI":"10.3390\/s20205926"},{"key":"S2631717621000165_r40","doi-asserted-by":"publisher","DOI":"10.1038\/s41528-020-0068-y"},{"key":"S2631717621000165_r32","doi-asserted-by":"publisher","DOI":"10.1109\/WIMOB.2010.5645046"},{"key":"S2631717621000165_r11","doi-asserted-by":"publisher","DOI":"10.1002\/admt.201700320"},{"key":"S2631717621000165_r4","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.1055\/s-0034-1375695","article-title":"The evolution of physical and technical performance parameters in the English premier league","volume":"35","author":"Barnes","year":"2014","journal-title":"International Journal of Sports Medicine"},{"key":"S2631717621000165_r30","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2006.889184"},{"key":"S2631717621000165_r7","doi-asserted-by":"publisher","DOI":"10.2196\/17032"},{"key":"S2631717621000165_r18","doi-asserted-by":"publisher","DOI":"10.1519\/JSC.0b013e3182610b7d"},{"key":"S2631717621000165_r17","doi-asserted-by":"publisher","DOI":"10.1080\/10739149.2020.1789657"},{"key":"S2631717621000165_r37","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-50124-6_8"},{"key":"S2631717621000165_r25","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2011.5975346"},{"key":"S2631717621000165_r6","doi-asserted-by":"publisher","DOI":"10.1123\/ijspp.2013-0418"},{"key":"S2631717621000165_r21","doi-asserted-by":"publisher","DOI":"10.1016\/j.future.2018.03.032"},{"key":"S2631717621000165_r9","doi-asserted-by":"publisher","DOI":"10.1179\/1743288X11Y.0000000006"},{"key":"S2631717621000165_r28","doi-asserted-by":"publisher","DOI":"10.1186\/s40798-020-00274-7"},{"key":"S2631717621000165_r10","doi-asserted-by":"publisher","DOI":"10.1519\/JSC.0000000000001575"},{"key":"S2631717621000165_r35","doi-asserted-by":"publisher","DOI":"10.3390\/s130709321"},{"key":"S2631717621000165_r14","doi-asserted-by":"publisher","DOI":"10.1136\/bjsports-2011-090664"},{"key":"S2631717621000165_r34","doi-asserted-by":"publisher","DOI":"10.1109\/MPRV.2008.40"},{"key":"S2631717621000165_r36","doi-asserted-by":"publisher","DOI":"10.1109\/JSEN.2020.2994552"},{"key":"S2631717621000165_r15","doi-asserted-by":"publisher","DOI":"10.3390\/s17122932"},{"key":"S2631717621000165_r38","doi-asserted-by":"publisher","DOI":"10.1016\/j.jsams.2013.03.016"},{"key":"S2631717621000165_r3","doi-asserted-by":"publisher","DOI":"10.1177\/0363546503258912"},{"key":"S2631717621000165_r31","doi-asserted-by":"publisher","DOI":"10.1249\/MSS.0b013e318236a3d2"},{"key":"S2631717621000165_r33","unstructured":"Steijlen, ASM , Bastemeijer, J , Plaude, L , French, PJ , Bossche, A and Jansen, KMB (2020) Development of sensor tights with integrated inertial measurement units for injury prevention in football. Paper presented at the Proceedings of the 6th International Conference on Design4Health, Amsterdam."},{"key":"S2631717621000165_r19","doi-asserted-by":"publisher","DOI":"10.1016\/j.compeleceng.2014.06.008"},{"key":"S2631717621000165_r26","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0153737"},{"key":"S2631717621000165_r5","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2015.04.007"},{"key":"S2631717621000165_r1","doi-asserted-by":"publisher","DOI":"10.12720\/ijsps.1.2.256-262"},{"key":"S2631717621000165_r29","doi-asserted-by":"publisher","DOI":"10.3390\/s16111847"},{"key":"S2631717621000165_r41","doi-asserted-by":"publisher","DOI":"10.3390\/s20092527"},{"key":"S2631717621000165_r22","doi-asserted-by":"publisher","DOI":"10.1109\/LCN.2010.5735712"},{"key":"S2631717621000165_r23","doi-asserted-by":"publisher","DOI":"10.1136\/bjsports-2018-099577"},{"key":"S2631717621000165_r27","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2017.03.015"}],"container-title":["Wearable Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S2631717621000165","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,29]],"date-time":"2021-11-29T11:27:26Z","timestamp":1638185246000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S2631717621000165\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021]]},"references-count":41,"alternative-id":["S2631717621000165"],"URL":"https:\/\/doi.org\/10.1017\/wtc.2021.16","relation":{},"ISSN":["2631-7176"],"issn-type":[{"value":"2631-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021]]},"assertion":[{"value":"\u00a9 The Author(s), 2021. Published by Cambridge University Press","name":"copyright","label":"Copyright","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}},{"value":"This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http:\/\/creativecommons.org\/licenses\/by\/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.","name":"license","label":"License","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}],"article-number":"e17"}}