{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T14:36:42Z","timestamp":1786199802558,"version":"build-2736575974"},"reference-count":42,"publisher":"Cambridge University Press (CUP)","license":[{"start":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T00:00:00Z","timestamp":1754870400000},"content-version":"unspecified","delay-in-days":222,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["cambridge.org"],"crossmark-restriction":true},"short-container-title":["Wearable Technol."],"published-print":{"date-parts":[[2025]]},"abstract":"<jats:title>Abstract<\/jats:title>\n\t  <jats:p>The Myoshirt, an active exosuit, provides gravity compensation for the shoulders. This study evaluated the impact of the Myoshirt on range of motion (ROM), endurance, and activities of daily living (ADLs) performance through tests involving nine participants with varying levels of arm impairments and diverse pathologies. Optical motion capture was used to quantify ROM of the shoulder and elbow joints during isolated movements and functional tasks. Endurance was quantified through a timed isometric shoulder flexion task, and a battery of ADL tasks was used to measure the perceived support of the exosuit, along with changes in movement quality. Feedback and usability insights were gathered with surveys. The Myoshirt did not significantly improve ROM during isolated movements (shoulder flexion, shoulder abduction, and elbow flexion\/extension), but during the reaching phase of a functional drinking task elbow extension increased significantly by 13.5% (t\u00a0=\u00a07.52, p\u00a0=\u00a0.002). Participants could also keep their arms elevated 78.7% longer (t\u00a0=\u00a01.942, p\u00a0=\u00a0.047). Patients also reported less perceived difficulty with ADLs while using the device, and a therapist reported improved execution quality. Participants who self-reported severe impairment levels tended to derive greater benefits compared to those with milder impairments. These findings highlight the potential of the Myoshirt as an assistive device, particularly for individuals with severe impairments, while emphasizing the need for further refinement.<\/jats:p>","DOI":"10.1017\/wtc.2025.10024","type":"journal-article","created":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T08:23:24Z","timestamp":1754900604000},"update-policy":"https:\/\/doi.org\/10.1017\/policypage","source":"Crossref","is-referenced-by-count":3,"title":["Impact of a shoulder exosuit on range of motion, endurance, and task execution in users with neurological impairments"],"prefix":"10.1017","volume":"6","author":[{"ORCID":"https:\/\/orcid.org\/0009-0005-6191-3801","authenticated-orcid":false,"given":"Adrian","family":"Esser","sequence":"first","affiliation":[{"name":"ETH Z\u00fcrich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabian","family":"M\u00fcller","sequence":"additional","affiliation":[{"name":"ETH Z\u00fcrich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Manczurowsky","sequence":"additional","affiliation":[{"name":"Northeastern University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Hasson","sequence":"additional","affiliation":[{"name":"Northeastern University"},{"name":"Institute for Experiential Robotics, Northeastern University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tim","family":"Unger","sequence":"additional","affiliation":[{"name":"Rehabilitation Engineering Laboratory (RELab)"},{"name":"Lake Lucerne Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chris","family":"Easthope Awai","sequence":"additional","affiliation":[{"name":"Lake Lucerne Institute"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Wolf","sequence":"additional","affiliation":[{"name":"ETH Z\u00fcrich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Riener","sequence":"additional","affiliation":[{"name":"ETH Z\u00fcrich"},{"name":"Balgrist University Hospital, University of Zurich"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2025,8,11]]},"reference":[{"key":"S2631717625100248_r7","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-01887-0_80"},{"key":"S2631717625100248_r2","doi-asserted-by":"publisher","DOI":"10.3791\/57228"},{"key":"S2631717625100248_r6","doi-asserted-by":"publisher","DOI":"10.1109\/EMBC.2016.7591824"},{"key":"S2631717625100248_r17","doi-asserted-by":"publisher","DOI":"10.1007\/s12555-016-0487-7"},{"key":"S2631717625100248_r26","first-page":"1","article-title":"The ArmeoSpring as a training tool to improve upper limb functionality in multiple sclerosis: A pilot study","volume":"15","author":"Mayr","year":"2018","journal-title":"Journal of Neuroengineering and Rehabilitation"},{"key":"S2631717625100248_r41","unstructured":"Unger, T , Moslehian, AS , Peiffer, JD , Ullrich, J , Gassert, R , Lambercy, O , Cotton, RJ and Easthope, CA (2024) Differentiable biomechanics for markerless motion capture in upper limb stroke rehabilitation: A comparison with optical motion capture. eprint: arXiv:2411.14992."},{"key":"S2631717625100248_r24","doi-asserted-by":"publisher","DOI":"10.1088\/1748-3190\/aad8d4"},{"key":"S2631717625100248_r11","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2009.2017111"},{"key":"S2631717625100248_r23","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2018.2854219"},{"key":"S2631717625100248_r13","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR66766.2025.11063015"},{"key":"S2631717625100248_r20","doi-asserted-by":"publisher","DOI":"10.1038\/s42256-022-00495-3"},{"key":"S2631717625100248_r8","doi-asserted-by":"publisher","DOI":"10.3233\/TAD-2002-14304"},{"key":"S2631717625100248_r29","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2022.3175224"},{"key":"S2631717625100248_r30","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2020.2982861"},{"key":"S2631717625100248_r31","first-page":"411","article-title":"Implementation of a robot-mediated upper limb rehabilitation protocol for a customized treatment after stroke: A retrospective analysis","volume":"54","author":"Pavan","year":"2024","journal-title":"NeuroRehabilitation"},{"key":"S2631717625100248_r4","doi-asserted-by":"publisher","DOI":"10.1017\/wtc.2024.21"},{"key":"S2631717625100248_r32","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.add1504"},{"key":"S2631717625100248_r12","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-016-0203-0"},{"key":"S2631717625100248_r34","doi-asserted-by":"publisher","DOI":"10.1109\/ACCESS.2020.3018418"},{"key":"S2631717625100248_r36","doi-asserted-by":"publisher","DOI":"10.1016\/j.msard.2017.11.016"},{"key":"S2631717625100248_r25","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiomech.2005.02.006"},{"key":"S2631717625100248_r28","first-page":"CD006876","article-title":"Electromechanical and robot-assisted arm training for improving activities of daily living, arm function, and arm muscle strength after stroke","volume":"9","author":"Mehrholz","year":"2018","journal-title":"Cochrane Database of Systematic Reviews"},{"key":"S2631717625100248_r15","doi-asserted-by":"publisher","DOI":"10.1177\/17474930211065917"},{"key":"S2631717625100248_r16","first-page":"S252","article-title":"Robot-assisted therapy for long-term upper-limb impairment after stroke","volume":"90","author":"Fluet","year":"2011","journal-title":"American Journal of Physical Medicine and Rehabilitation"},{"key":"S2631717625100248_r38","doi-asserted-by":"publisher","DOI":"10.1109\/TMRB.2020.3012471"},{"key":"S2631717625100248_r33","doi-asserted-by":"publisher","DOI":"10.1007\/s00221-019-05687-9"},{"key":"S2631717625100248_r3","first-page":"114","article-title":"Determining what individual SUS scores mean: Adding an adjective rating scale","volume":"4","author":"Bangor","year":"2009","journal-title":"Journal of User Experience"},{"key":"S2631717625100248_r1","doi-asserted-by":"publisher","DOI":"10.1177\/1545968312448234"},{"key":"S2631717625100248_r39","doi-asserted-by":"publisher","DOI":"10.1007\/s00221-007-1029-6"},{"key":"S2631717625100248_r37","doi-asserted-by":"publisher","DOI":"10.1109\/ICRA.2017.7989785"},{"key":"S2631717625100248_r14","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(21)00252-0"},{"key":"S2631717625100248_r22","unstructured":"Hocoma (2024) Armeo\u00aeSpring \u2013 Hocoma. Available at https:\/\/www.hocoma.com\/de\/losungen\/armeospring-2\/ (accessed 10 December 2024)."},{"key":"S2631717625100248_r9","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-57111-9_1792"},{"key":"S2631717625100248_r27","doi-asserted-by":"crossref","first-page":"86","DOI":"10.32598\/RJ.22.1.3238.1","article-title":"The relationship between upper limb function and participation and independence in daily activities of life in people with stroke","volume":"22","author":"Mazidi","year":"2021","journal-title":"Archives of Rehabilitation"},{"key":"S2631717625100248_r5","first-page":"207","volume-title":"Usability Evaluation In Industry","author":"Brooke","year":"1996"},{"key":"S2631717625100248_r21","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2023-075049"},{"key":"S2631717625100248_r35","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-024-01506-7"},{"key":"S2631717625100248_r10","doi-asserted-by":"publisher","DOI":"10.1177\/1545968309332927"},{"key":"S2631717625100248_r18","doi-asserted-by":"publisher","DOI":"10.1109\/ICORR.2019.8779401"},{"key":"S2631717625100248_r40","doi-asserted-by":"publisher","DOI":"10.3389\/fdgth.2024.1359776"},{"key":"S2631717625100248_r19","doi-asserted-by":"publisher","DOI":"10.1109\/BioRob49111.2020.9224460"},{"key":"S2631717625100248_r42","unstructured":"Vicon (2024) Upper Limb Model. Available at https:\/\/www.vicon.com\/software\/models-and-scripts\/upper-limb-model\/?section=downloads (accessed 9 December 2024)."}],"container-title":["Wearable Technologies"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S2631717625100248","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T08:23:26Z","timestamp":1754900606000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S2631717625100248\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025]]},"references-count":42,"alternative-id":["S2631717625100248"],"URL":"https:\/\/doi.org\/10.1017\/wtc.2025.10024","relation":{},"ISSN":["2631-7176"],"issn-type":[{"value":"2631-7176","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025]]},"assertion":[{"value":"\u00a9 The Author(s), 2025. Published by Cambridge University Press","name":"copyright","label":"Copyright","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}},{"value":"This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http:\/\/creativecommons.org\/licenses\/by\/4.0), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.","name":"license","label":"License","group":{"name":"copyright_and_licensing","label":"Copyright and Licensing"}},{"value":"This content has been made available to all.","name":"free","label":"Free to read"}],"article-number":"e42"}}