{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T03:46:30Z","timestamp":1794887190411,"version":"4.9.1"},"reference-count":33,"publisher":"American Chemical Society (ACS)","issue":"33","license":[{"start":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T00:00:00Z","timestamp":1784764800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,8,25]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>We describe a custom preparation of high-performance affinity columns based on 3.5 \u03bcm nonporous polymeric particles covalently modified with streptavidin. The sorbent was packed into a 2.1 \u00d7 20 mm column hardware compatible with pressures up to 10,000 psi (68 MPa). Biotinylated affinity ligands were then immobilized on-column using a repetitive injection method until the streptavidin sorbent was saturated. The saturation was observed as a ligand breakthrough signal by ultraviolet detection. Column binding capacity of immobilized affinity ligands was estimated for d-biotin, biotinylated 25nt oligodeoxythymidine, and biotinylated anti-insulin mAb ligands. The prepared columns were used to quantify mRNA and insulin. Affinity column performance was evaluated in terms of binding capacity, calibration linearity range, and target analyte limit of quantitation. The high-performance streptavidin column is a platform for custom-made affinity chromatography device preparation, enabling routine quantitation of analytes of interest.<\/jats:p>","DOI":"10.1021\/acs.analchem.6c01884","type":"journal-article","created":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T12:13:44Z","timestamp":1784808824000},"page":"24117-24125","source":"Crossref","is-referenced-by-count":3,"title":["On-Column Preparation\nof High-Performance Affinity\nChromatography Columns"],"prefix":"10.1021","volume":"98","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1199-1287","authenticated-orcid":true,"given":"Martin","family":"Gilar","sequence":"first","affiliation":[{"name":"Waters Corporation , , ,","place":["Milford, Massachusetts, United States, 01757-3696"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-4176-9812","authenticated-orcid":true,"given":"Beatrice","family":"Muriithi","sequence":"additional","affiliation":[{"name":"Waters Corporation , , ,","place":["Milford, Massachusetts, United States, 01757-3696"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yeliz T.","family":"Sarisozen","sequence":"additional","affiliation":[{"name":"Waters Corporation , , ,","place":["Milford, Massachusetts, United States, 01757-3696"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philip","family":"Wuthrich","sequence":"additional","affiliation":[{"name":"Waters Corporation , , ,","place":["Milford, Massachusetts, United States, 01757-3696"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Donegan","sequence":"additional","affiliation":[{"name":"Waters Corporation , , ,","place":["Milford, Massachusetts, United States, 01757-3696"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin D.","family":"Wyndham","sequence":"additional","affiliation":[{"name":"Waters Corporation , , ,","place":["Milford, Massachusetts, United States, 01757-3696"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,7,23]]},"reference":[{"issue":"12","key":"2026083118450515000_cit1","doi-asserted-by":"publisher","first-page":"3059","DOI":"10.1016\/S0021-9258(18)63022-4","article-title":"Protein purification\nby affinity chromatography. Derivatizations of agarose and polyacrylamide\nbeads","volume":"245","author":"Cuatrecasas","year":"1970","journal-title":"J. Biol. Chem."},{"issue":"4","key":"2026083118450515000_cit2","doi-asserted-by":"publisher","first-page":"769","DOI":"10.4155\/bio.10.31","article-title":"Immunoaffinity chromatography:\nAn introduction to applications\nand recent developments","volume":"2","author":"Moser","year":"2010","journal-title":"Bioanalysis"},{"key":"2026083118450515000_cit3","doi-asserted-by":"publisher","first-page":"465647","DOI":"10.1016\/j.chroma.2024.465647","article-title":"Leveraging\nprior knowledge for process parameter classification in mAb Protein\nA chromatography","volume":"1742","author":"Tao","year":"2025","journal-title":"J. Chromatogr. A"},{"key":"2026083118450515000_cit4","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/978-1-60761-913-0","volume-title":"Protein\nChromatography: methods and Protocols","author":"Dermot Walls","year":"2011"},{"issue":"12","key":"2026083118450515000_cit5","doi-asserted-by":"publisher","first-page":"10329","DOI":"10.3390\/ijms241210329","article-title":"Low-Abundance Protein\nEnrichment for Medical Applications:\nThe Involvement of Combinatorial Peptide Library Technique","volume":"24","author":"Boschetti","year":"2023","journal-title":"Int. J. Mol. Sci."},{"issue":"9","key":"2026083118450515000_cit6","doi-asserted-by":"publisher","first-page":"2802","DOI":"10.1021\/ac048751x","article-title":"Use of multidimensional lectin affinity chromatography\nin differential glycoproteomics","volume":"77","author":"Qiu","year":"2005","journal-title":"Anal. Chem."},{"key":"2026083118450515000_cit7","doi-asserted-by":"publisher","first-page":"746822","DOI":"10.3389\/fmolb.2021.746822","article-title":"Recent Advances\nin Lectin-Based Affinity\nSorbents for Protein Glycosylation Studies","volume":"8","author":"Goumenou","year":"2021","journal-title":"Front. Mol. Biosci."},{"key":"2026083118450515000_cit8","doi-asserted-by":"publisher","first-page":"465454","DOI":"10.1016\/j.chroma.2024.465454","article-title":"Pore structure reconstruction\nto reveal the adsorption capacity limitation of current oligo-dT resins\nand guide new resin design","volume":"1737","author":"Qiao","year":"2024","journal-title":"J. Chromatogr. A"},{"issue":"1\u20132","key":"2026083118450515000_cit9","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/0378-4347(93)80040-B","article-title":"Affinity\nchromatography with nucleic acid polymers","volume":"618","author":"Jarrett","year":"1993","journal-title":"J.\nChromatogr. B: Biomed. Sci. Appl."},{"key":"2026083118450515000_cit10","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1016\/S0076-6879(09)63026-3","article-title":"Affinity chromatography:\ngeneral\nmethods","volume":"463","author":"Urh","year":"2009","journal-title":"Methods Enzymol."},{"key":"2026083118450515000_cit11","doi-asserted-by":"publisher","first-page":"460846","DOI":"10.1016\/j.chroma.2019.460846","article-title":"Versatile modules enable\nautomated multi-column purifications on the AKTA pure chromatography\nsystem","volume":"1618","author":"Franke","year":"2020","journal-title":"J. Chromatogr. A"},{"key":"2026083118450515000_cit12","doi-asserted-by":"publisher","first-page":"466061","DOI":"10.1016\/j.chroma.2025.466061","article-title":"Fundamentals of protein affinity\nchromatography: How\nto prepare and properly use an affinity matrix","volume":"1756","author":"Bilkova","year":"2025","journal-title":"J. Chromatogr. A"},{"key":"2026083118450515000_cit13","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.jpba.2017.04.028","article-title":"Application of protein A-modified capillary-channeled\npolymer polypropylene fibers to the quantitation of IgG in complex\nmatrices","volume":"142","author":"Trang","year":"2017","journal-title":"J. Pharm. Biomed. Anal."},{"key":"2026083118450515000_cit14","doi-asserted-by":"publisher","first-page":"124205","DOI":"10.1016\/j.jchromb.2024.124205","article-title":"A case study\napplication\nof AQbD to the re-development and validation of an affinity chromatography\nanalytical procedure for mAb titer quantitation","volume":"1242","author":"Cernosek","year":"2024","journal-title":"J. Chromatogr. B., Analyt Technol. Biomed. Life Sci"},{"key":"2026083118450515000_cit15","doi-asserted-by":"publisher","first-page":"464670","DOI":"10.1016\/j.chroma.2024.464670","article-title":"Improved mRNA affinity\nchromatography binding capacity and throughput using an oligo-dT immobilized\nelectrospun polymer nanofiber adsorbent","volume":"1717","author":"Dewar","year":"2024","journal-title":"J.\nChromatogr. A"},{"key":"2026083118450515000_cit16","doi-asserted-by":"publisher","first-page":"466382","DOI":"10.1016\/j.chroma.2025.466382","article-title":"Structure-performance\nanalysis of oligo(dT) resin affinity chromatography for RNA separations","volume":"1762","author":"Grinsted","year":"2025","journal-title":"J. Chromatogr. A"},{"issue":"2","key":"2026083118450515000_cit17","doi-asserted-by":"publisher","first-page":"335","DOI":"10.18609\/cgti.2022.049","article-title":"Purification of therapeutic &\nprophylactic mRNA by affinity chromatography","volume":"8","author":"Grinsted","year":"2022","journal-title":"Cell And Gene Ther. Insights"},{"issue":"6","key":"2026083118450515000_cit18","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1073\/pnas.69.6.1408","article-title":"Purification of biologically\nactive globin messenger RNA by chromatography\non oligothymidylic acid-cellulose","volume":"69","author":"Aviv","year":"1972","journal-title":"Proc. Natl.\nAcad. Sci. U. S. A."},{"key":"2026083118450515000_cit19","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.omtm.2022.12.009","article-title":"High-efficiency\npurification of divergent AAV serotypes using AAVX affinity chromatography","volume":"28","author":"Florea","year":"2023","journal-title":"Mol. Ther. Methods Clin. Dev."},{"issue":"3","key":"2026083118450515000_cit20","doi-asserted-by":"publisher","DOI":"10.1002\/biot.202400656","article-title":"Rapid At-Line\nAAVX Affinity HPLC:\nEnabling Process Analytical Technology for Bioprocess Development\nof Adeno-Associated Virus Vectors","volume":"20","author":"Heckel","year":"2025","journal-title":"Biotechnol.\nJ."},{"key":"2026083118450515000_cit21","doi-asserted-by":"publisher","first-page":"465013","DOI":"10.1016\/j.chroma.2024.465013","article-title":"Expediting online liquid chromatography\nfor real-time monitoring of product attributes to advance process\nanalytical technology in downstream processing of biopharmaceuticals","volume":"1729","author":"Graf","year":"2024","journal-title":"J. Chromatogr. A"},{"key":"2026083118450515000_cit22","volume-title":"Bioconjugate techniques","author":"Hermanson","year":"2013"},{"issue":"47","key":"2026083118450515000_cit23","doi-asserted-by":"publisher","first-page":"28204","DOI":"10.1074\/jbc.270.47.28204","article-title":"Recombinant\ncore streptavidins. A minimum-sized core streptavidin has enhanced\nstructural stability and higher accessibility to biotinylated macromolecules","volume":"270","author":"Sano","year":"1995","journal-title":"J. Biol. Chem."},{"key":"2026083118450515000_cit24","first-page":"63","article-title":"H","volume-title":"Immobilisation of DNA on Chips II","author":"Smith","year":"2006"},{"issue":"48","key":"2026083118450515000_cit25","doi-asserted-by":"publisher","first-page":"26349","DOI":"10.1021\/acs.analchem.5c04766","article-title":"High-Efficiency Analytical Protein\nA Columns for High Sensitivity Monoclonal Antibody Titer Analysis","volume":"97","author":"Muriithi","year":"2025","journal-title":"Anal. Chem."},{"key":"2026083118450515000_cit26","volume-title":"An Easy-to-Execute\nDirect-Connect 2D Protein A\u2013SEC Method for the Analysis of\nMonoclonal Antibody Titer and Size Variants in Cell Culture, 720008780","author":"Koza","year":"2025"},{"key":"2026083118450515000_cit27","doi-asserted-by":"publisher","first-page":"466455","DOI":"10.1016\/j.chroma.2025.466455","article-title":"High-performance\nchromatographic immunoassays with\na biotin-streptavidin platform for the selective analysis of vaccine\nantigens","volume":"1763","author":"Kyei","year":"2025","journal-title":"J. Chromatogr. A"},{"issue":"18","key":"2026083118450515000_cit28","doi-asserted-by":"publisher","first-page":"7063","DOI":"10.1021\/ac801199k","article-title":"Monitoring\nof real-time\nstreptavidin-biotin binding kinetics using droplet microfluidics","volume":"80","author":"Srisa-Art","year":"2008","journal-title":"Anal. Chem."},{"issue":"13\u201314","key":"2026083118450515000_cit29","doi-asserted-by":"publisher","first-page":"1674","DOI":"10.1016\/j.tetasy.2010.05.029","article-title":"MISER chromatography\n(multiple injections in a single experimental run): the chromatogram\nis the graph","volume":"21","author":"Welch","year":"2010","journal-title":"Tetrahedron: Asymmetry"},{"key":"2026083118450515000_cit30","unstructured":"Wyndham, K.; Muriithi, B.; Tchoul, O. D.; Sarisozen, Y. T.; Xu, M.; Lauber, M.\n          Particles for affinity\nchromatography; WO 2,024,224,364 A3, 2024."},{"key":"2026083118450515000_cit31","doi-asserted-by":"publisher","first-page":"460931","DOI":"10.1016\/j.chroma.2020.460931","article-title":"Evaluating MISER chromatography as\na tool for characterizing\nHILIC column equilibration","volume":"1619","author":"Berthelette","year":"2020","journal-title":"J. Chromatogr. A"},{"key":"2026083118450515000_cit32","doi-asserted-by":"publisher","first-page":"462247","DOI":"10.1016\/j.chroma.2021.462247","article-title":"Mitigation\nof analyte loss on metal\nsurfaces in liquid chromatography","volume":"1650","author":"Gilar","year":"2021","journal-title":"J. Chromatogr.\nA"},{"key":"2026083118450515000_cit33","volume-title":"Low Adsorption HPLC Columns\nBased\non MaxPeak High Performance Surfaces, White Paper, 720006930EN","author":"Lauber","year":"2021"}],"container-title":["Analytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acs.analchem.6c01884","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/33\/24117\/66227984\/acs.analchem.6c01884.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/33\/24117\/66227984\/acs.analchem.6c01884.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T22:45:15Z","timestamp":1788216315000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/ancham\/article\/98\/33\/24117\/5230730\/On-Column-Preparation-of-High-Performance-Affinity"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,23]]},"references-count":33,"journal-issue":{"issue":"33","published-online":{"date-parts":[[2026,7,23]]},"published-print":{"date-parts":[[2026,8,25]]}},"URL":"https:\/\/doi.org\/10.1021\/acs.analchem.6c01884","relation":{"has-part":[{"id-type":"doi","id":"https:\/\/doi.org\/10.1021\/acs.analchem.6c01884.s001","asserted-by":"subject"}]},"ISSN":["0003-2700","1520-6882"],"issn-type":[{"value":"0003-2700","type":"print"},{"value":"1520-6882","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,23]]}}}