{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T13:04:26Z","timestamp":1785243866556,"version":"3.55.0"},"reference-count":33,"publisher":"American Chemical Society (ACS)","issue":"29","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-045"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["2025YFF1107404"],"award-info":[{"award-number":["2025YFF1107404"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100002365","name":"China Agricultural University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002365","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Reliable pathogen detection in complex suspensions requires both effective sample handling and stable signal generation. Here, we report an acoustofluidic\u2013magnetic relaxation biosensing (MRB) platform for Salmonella detection that combines acoustofluidic particle manipulation with oscillation-stabilized magnetic readout. A cylindrical-array region enhances encounters between Salmonella and immunomagnetic nanobeads (IMNBs) through convective mixing, while a butterfly-shaped acoustic streaming vortex (BSAV) region preferentially retains micron-scale Salmonella\u2013IMNB complexes and generates a nanoscale-dominant outlet suspension. This outlet suspension is subsequently analyzed by an oscillation-assisted MRB system, in which axial micro-oscillation suppresses bead sedimentation and aggregation and stabilizes the \u0394T2 response. Under optimized conditions, the biosensor showed a linear response from 4.8 \u00d7 101 to 4.8 \u00d7 105 CFU\/mL, with a limit of detection of 29 CFU\/mL and a total assay time of approximately 40 min. The platform also exhibited good specificity and satisfactory recoveries of 92.68\u2013103.95% in spiked chicken samples. The results demonstrate that acoustofluidic restructuring of suspension composition can support stable and quantitative magnetic relaxation detection in the Salmonella-spiked chicken model system.<\/jats:p>","DOI":"10.1021\/acs.analchem.6c02311","type":"journal-article","created":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T02:09:57Z","timestamp":1782958197000},"page":"21583-21594","source":"Crossref","is-referenced-by-count":0,"title":["Integrated\nAcoustofluidic Manipulation and Oscillation-Stabilized\nMagnetic Relaxation Biosensing for\n                    <i>Salmonella<\/i>\n                    Detection"],"prefix":"10.1021","volume":"98","author":[{"given":"Jiaqing","family":"Duan","sequence":"first","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yingqiao","family":"Zhu","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gaofei","family":"Lei","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kaiyuan","family":"Jia","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guodong","family":"Li","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Taige","family":"Fu","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3709-084X","authenticated-orcid":true,"given":"Lei","family":"Wang","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9458-1077","authenticated-orcid":true,"given":"Jianhan","family":"Lin","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4758-8596","authenticated-orcid":true,"given":"Yuhe","family":"Wang","sequence":"additional","affiliation":[{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]},{"name":"China Agricultural University , , ,","place":["Beijing, China, 100083"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,7,1]]},"reference":[{"key":"2026072808090096000_cit1","doi-asserted-by":"publisher","first-page":"110246","DOI":"10.1016\/j.foodres.2021.110246","article-title":"Microfluidic Devices\nfor Multiplexed Detection of Foodborne Pathogens","volume":"143","author":"Han","year":"2021","journal-title":"Food Res. Int."},{"key":"2026072808090096000_cit2","doi-asserted-by":"publisher","first-page":"117785","DOI":"10.1016\/j.trac.2024.117785","article-title":"Optical Biosensors for the Detection of Foodborne Pathogens:\nRecent Development and Future Prospects","volume":"177","author":"Wang","year":"2024","journal-title":"TrAC,\nTrends Anal. Chem."},{"issue":"1","key":"2026072808090096000_cit3","doi-asserted-by":"publisher","first-page":"8769","DOI":"10.1038\/s41467-025-63929-7","article-title":"AI-Powered High-Throughput\nDigital Colony Picker Platform for Sorting\nMicrobial Strains by Multi-Modal Phenotypes","volume":"16","author":"Diao","year":"2025","journal-title":"Nat. Commun."},{"key":"2026072808090096000_cit4","doi-asserted-by":"publisher","first-page":"117238","DOI":"10.1016\/j.microc.2026.117238","article-title":"A Colorimetric Biosensor\nfor Salmonella Detection\nCombining Cascaded Magnetophoretic Separation and Nanozyme Signal\nAmplification","volume":"222","author":"Duan","year":"2026","journal-title":"Microchem. J."},{"key":"2026072808090096000_cit5","doi-asserted-by":"publisher","first-page":"117359","DOI":"10.1016\/j.bios.2025.117359","article-title":"Direct Isolation of\nMultiple Types\nof Circulating Tumor Cells from Undiluted Human Blood Using Cascaded\nViscoelastic Microfluidics","volume":"278","author":"Lu","year":"2025","journal-title":"Biosens. Bioelectron."},{"issue":"35","key":"2026072808090096000_cit6","doi-asserted-by":"publisher","first-page":"14222","DOI":"10.1021\/acs.analchem.4c02876","article-title":"An Integrated\nInertial-Magnetophoresis Microfluidic Chip Online-Coupled with ICP-MS\nfor Rapid Separation and Precise Detection of Circulating Tumor Cells","volume":"96","author":"Cai","year":"2024","journal-title":"Anal. Chem."},{"issue":"1","key":"2026072808090096000_cit7","doi-asserted-by":"publisher","DOI":"10.1002\/adma.202207093","article-title":"A Self-Powered Dielectrophoretic\nMicroparticle Manipulation Platform Based on a Triboelectric Nanogenerator","volume":"35","author":"Zhou","year":"2023","journal-title":"Adv. Mater."},{"issue":"6","key":"2026072808090096000_cit8","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.1039\/D4LC00783B","article-title":"A Plug-and-Play Microfluidic Device for Hydrogel Fiber\nSpinning","volume":"25","author":"Wei","year":"2025","journal-title":"Lab Chip"},{"issue":"29","key":"2026072808090096000_cit9","doi-asserted-by":"publisher","first-page":"15949","DOI":"10.1021\/acs.analchem.5c02565","article-title":"An Integrated Microfluidic Platform\nfor Label-Free Sorting and Functional Assessment of Neutrophils in\nSepsis","volume":"97","author":"Yang","year":"2025","journal-title":"Anal. Chem."},{"issue":"17","key":"2026072808090096000_cit10","doi-asserted-by":"publisher","first-page":"6764","DOI":"10.1021\/acs.analchem.4c00485","article-title":"High-Density Microporous\nDrainage-Integrating Sheath\nFlow Generator for Streamlining Microfluidic Cell Sorting Systems","volume":"96","author":"Hayashi","year":"2024","journal-title":"Anal. Chem."},{"issue":"51","key":"2026072808090096000_cit11","doi-asserted-by":"publisher","DOI":"10.1002\/smll.201904732","article-title":"Combinatorial Immunophenotyping of Cell Populations\nwith an Electronic Antibody Microarray","volume":"15","author":"Liu","year":"2019","journal-title":"Small"},{"key":"2026072808090096000_cit12","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1038\/s41378-022-00435-6","article-title":"Recent Advances\nin Acoustofluidic Separation Technology in Biology","volume":"8","author":"Fan","year":"2022","journal-title":"Microsyst. Nanoeng."},{"issue":"5","key":"2026072808090096000_cit13","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1038\/s41563-025-02169-y","article-title":"Topological\nAcoustofluidics","volume":"24","author":"Zhao","year":"2025","journal-title":"Nat. Mater."},{"issue":"3","key":"2026072808090096000_cit14","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.adt5464","article-title":"Rapid\nand Comprehensive Detection of Viral Antibodies and Nucleic Acids\nvia an Acoustofluidic Integrated Molecular Diagnostics Chip: AIMDx","volume":"11","author":"Qian","year":"2025","journal-title":"Sci. Adv."},{"key":"2026072808090096000_cit15","doi-asserted-by":"publisher","first-page":"115746","DOI":"10.1016\/j.bios.2023.115746","article-title":"Ultrasound-Enhanced Catalytic Hairpin\nAssembly Capable of Ultrasensitive MicroRNA Biosensing for the Early\nScreening of Alzheimer\u2019s Disease","volume":"242","author":"Luo","year":"2023","journal-title":"Biosens.\nBioelectron."},{"issue":"16","key":"2026072808090096000_cit16","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.adu8915","article-title":"Oscillating microbubble\narray\u2013based metamaterials\n(OMAMs) for rapid isolation of high-purity exosomes","volume":"11","author":"Li","year":"2025","journal-title":"Sci. Adv."},{"issue":"3","key":"2026072808090096000_cit17","doi-asserted-by":"publisher","first-page":"2232","DOI":"10.1021\/acssensors.5c04047","article-title":"On-Chip Pathogens Enrichment and Detection Using Dual Vortex-Enhanced\nAcoustofluidic Tornado","volume":"11","author":"Wei","year":"2026","journal-title":"ACS Sens."},{"key":"2026072808090096000_cit18","doi-asserted-by":"publisher","first-page":"0319","DOI":"10.34133\/cbsystems.0319","article-title":"An Acoustofluidic\nDevice for Sample Preparation and Detection of Small Extracellular\nVesicles","volume":"6","author":"Liu","year":"2025","journal-title":"Cyborg Bionic Syst."},{"issue":"1","key":"2026072808090096000_cit19","doi-asserted-by":"publisher","DOI":"10.1002\/advs.202409394","article-title":"Acoustofluidic Tweezers Integrated with Droplet Sensing Enable Multifunctional\nClosed-Loop Droplet Manipulation","volume":"12","author":"Sui","year":"2025","journal-title":"Adv. Sci."},{"issue":"26","key":"2026072808090096000_cit20","doi-asserted-by":"publisher","DOI":"10.1073\/pnas.2025406118","article-title":"Flow Field\nAround Bubbles on Formation of Air Embolism in Small Vessels","volume":"118","author":"Li","year":"2021","journal-title":"Proc. Natl. Acad. Sci. U. S. A."},{"key":"2026072808090096000_cit21","doi-asserted-by":"publisher","first-page":"103276","DOI":"10.1016\/j.cis.2024.103276","article-title":"Acoustofluidic\nPrecise\nManipulation: Recent Advances in Applications for Micro\/Nano Bioparticles","volume":"332","author":"Li","year":"2024","journal-title":"Adv. Colloid Interface Sci."},{"issue":"10","key":"2026072808090096000_cit22","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.adm8597","article-title":"Acoustic Separation\nand Concentration of Exosomes for Nucleotide\nDetection: ASCENDx","volume":"10","author":"Naquin","year":"2024","journal-title":"Sci. Adv."},{"issue":"33","key":"2026072808090096000_cit23","doi-asserted-by":"publisher","first-page":"22596","DOI":"10.1021\/acsnano.4c09692","article-title":"Acoustofluidic Virus Isolation via Bessel Beam Excitation\nSeparation Technology","volume":"18","author":"Xia","year":"2024","journal-title":"ACS Nano"},{"key":"2026072808090096000_cit24","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1038\/s41378-024-00731-3","article-title":"Acoustofluidics-Enhanced\nBiosensing with Simultaneously High Sensitivity and Speed","volume":"10","author":"Li","year":"2024","journal-title":"Microsyst. Nanoeng."},{"key":"2026072808090096000_cit25","doi-asserted-by":"publisher","first-page":"104387","DOI":"10.1016\/j.tifs.2024.104387","article-title":"Recent Advances\nin Magnetic Relaxation Switching Biosensors for Animal-Derived Food\nSafety Detection","volume":"146","author":"Wei","year":"2024","journal-title":"Trends Food Sci. Technol."},{"issue":"40","key":"2026072808090096000_cit26","doi-asserted-by":"publisher","first-page":"14934","DOI":"10.1021\/acs.analchem.3c02285","article-title":"Fully Integrated Microfluidic Device for Magnetic Bead\nManipulation to Assist Rapid Reaction and Cleaning","volume":"95","author":"Yang","year":"2023","journal-title":"Anal. Chem."},{"issue":"36","key":"2026072808090096000_cit27","doi-asserted-by":"publisher","first-page":"32246","DOI":"10.1021\/acsnano.5c06890","article-title":"Suppression of Spin-Orbit Torque Switching by the Magnetic\nProximity\nEffect","volume":"19","author":"Cheng","year":"2025","journal-title":"ACS Nano"},{"issue":"9","key":"2026072808090096000_cit28","doi-asserted-by":"publisher","first-page":"8646","DOI":"10.1021\/acsnano.4c14913","article-title":"Deactivated Cas9-Engineered Magnetic\nMicromotors toward\na Point-of-Care Digital Viral RNA Assay","volume":"19","author":"Song","year":"2025","journal-title":"ACS\nNano"},{"key":"2026072808090096000_cit29","doi-asserted-by":"publisher","first-page":"133686","DOI":"10.1016\/j.snb.2023.133686","article-title":"Win-Win Cooperation:\nMagnetic Relaxation Switching Biosensor for Chloramphenicol Detection\nBased on the Pipet Platform and Antigen-Driven Enzyme-Free Dual Signal\nAmplification Strategy","volume":"385","author":"Hong","year":"2023","journal-title":"Sens. Actuators, B"},{"key":"2026072808090096000_cit30","doi-asserted-by":"publisher","first-page":"134386","DOI":"10.1016\/j.snb.2023.134386","article-title":"Magnetic Relaxation\nSwitching Biosensor for One-Step\nDetection of Vibrio Parahaemolyticus Based on Click\nChemistry-Mediated Sol-Gel System","volume":"394","author":"Chen","year":"2023","journal-title":"Sens. Actuators,\nB"},{"key":"2026072808090096000_cit31","doi-asserted-by":"publisher","first-page":"123619","DOI":"10.1016\/j.jhazmat.2020.123619","article-title":"Double-Enzymes-Mediated\nFe2+\/Fe3+ Conversion as Magnetic Relaxation\nSwitch for Pesticide Residues Sensing","volume":"403","author":"Wu","year":"2021","journal-title":"J. Hazard.\nMater."},{"issue":"4","key":"2026072808090096000_cit32","doi-asserted-by":"publisher","first-page":"2802","DOI":"10.1021\/acssensors.4c03552","article-title":"Stable Magnetic Relaxation Switch\nSensor Based on Fe3O4@Gel for Ultrafast Detection\nof Cd2+","volume":"10","author":"Yao","year":"2025","journal-title":"ACS Sens."},{"issue":"13","key":"2026072808090096000_cit33","doi-asserted-by":"publisher","first-page":"14928","DOI":"10.1021\/acsami.1c00430","article-title":"H2O2-Responsive\nGold Nanoclusters @ Mesoporous Silica @\nManganese Dioxide Nanozyme for \u201cOff\/On\u201d Modulation and\nEnhancement of Magnetic Resonance Imaging and Photodynamic Therapy","volume":"13","author":"Yin","year":"2021","journal-title":"ACS Appl. Mater. Interfaces"}],"container-title":["Analytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acs.analchem.6c02311","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/29\/21583\/66297668\/acs.analchem.6c02311.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/29\/21583\/66297668\/acs.analchem.6c02311.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T12:21:17Z","timestamp":1785241277000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/ancham\/article\/98\/29\/21583\/5234934\/Integrated-Acoustofluidic-Manipulation-and"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,1]]},"references-count":33,"journal-issue":{"issue":"29","published-online":{"date-parts":[[2026,7,1]]},"published-print":{"date-parts":[[2026,7,28]]}},"URL":"https:\/\/doi.org\/10.1021\/acs.analchem.6c02311","relation":{},"ISSN":["0003-2700","1520-6882"],"issn-type":[{"value":"0003-2700","type":"print"},{"value":"1520-6882","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,1]]}}}