{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T13:04:34Z","timestamp":1785243874821,"version":"3.55.0"},"reference-count":52,"publisher":"American Chemical Society (ACS)","issue":"29","license":[{"start":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T00:00:00Z","timestamp":1784073600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T00:00:00Z","timestamp":1784073600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T00:00:00Z","timestamp":1784073600000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-045"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["22474008"],"award-info":[{"award-number":["22474008"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,28]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The escalating threat of airborne chemical and biological pollutants demands real-time monitoring technologies capable of simultaneously detecting both classes of contaminants. Conventional analytical methods are frequently constrained by slow response times, high labor requirements, or confinement to laboratory settings. Here, we present a field-deployable instrument, designated as the CB-pMS (chemical and biological portable mass spectrometer), for the automated online detection of volatile organic compounds (VOCs) and bioaerosols. The instrument incorporates an orthogonal hybrid ionization source combining vacuum ultraviolet photoionization (UV-PI) and electrospray ionization (ESI) paired with a pyrolysis interface, enabling noninterfering operation and synergistic ionization of VOCs and airborne microorganisms. The CB-pMS achieves detection limits of 1 ng\/mL for liquid-phase hypaconitine and 10 ppbv for gas-phase dimethyl methyl phosphonate (DMMP), exhibiting excellent linearity (R2 &amp;gt; 0.99) and MS\/MS confirmation capability for analyte identification. In a dynamic wind tunnel experiment designed to simulate realistic environmental conditions, the instrument successfully conducted automated sequential analysis of benzene, toluene, xylene, and airborne Bacillus subtilis. With compact dimensions (48 cm \u00d7 34 cm \u00d7 56 cm) and a weight of 42 kg, the CB-pMS represents a significant advancement toward field-deployable, comprehensive monitoring of airborne chemical and biological threats for environmental surveillance, industrial hygiene, and homeland security applications.<\/jats:p>","DOI":"10.1021\/acs.analchem.6c03165","type":"journal-article","created":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T20:20:36Z","timestamp":1784146836000},"page":"21838-21847","source":"Crossref","is-referenced-by-count":0,"title":["A Chemical\nand Biological Portable Mass Spectrometer\n(CB-pMS) with Automated Sampling and Hybrid Ionization for Online\nDetection of Bioaerosols and VOCs"],"prefix":"10.1021","volume":"98","author":[{"given":"Baokun","family":"Yang","sequence":"first","affiliation":[{"name":"Beijing Institute of Technology , , ,","place":["Beijing, China, 100081"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shiyu","family":"Du","sequence":"additional","affiliation":[{"name":"Beijing Institute of Technology , , ,","place":["Beijing, China, 100081"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiao","family":"Han","sequence":"additional","affiliation":[{"name":"Beijing Institute of Technology , , ,","place":["Beijing, China, 100081"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5274-1546","authenticated-orcid":true,"given":"Wei","family":"Xu","sequence":"additional","affiliation":[{"name":"Beijing Institute of Technology , , ,","place":["Beijing, China, 100081"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5601-5568","authenticated-orcid":true,"given":"Baoqiang","family":"Li","sequence":"additional","affiliation":[{"name":"State Key Laboratory of Chemistry for NBC Hazards Protection , ,","place":["Beijing, China, 102205"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2280-9794","authenticated-orcid":true,"given":"Yanbing","family":"Zhai","sequence":"additional","affiliation":[{"name":"Beijing Institute of Technology , , ,","place":["Beijing, China, 100081"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,7,15]]},"reference":[{"key":"2026072808074477000_cit1","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.jes.2016.07.002","article-title":"Molecular approaches for the detection\nand monitoring of microbial communities in bioaerosols: A review","volume":"51","author":"Yoo","year":"2017","journal-title":"Journal of Environmental Sciences"},{"issue":"1","key":"2026072808074477000_cit2","doi-asserted-by":"publisher","first-page":"17083","DOI":"10.1038\/micronano.2017.83","article-title":"Field-deployable rapid multiple biosensing\nsystem for\ndetection of chemical and biological warfare agents","volume":"4","author":"Saito","year":"2018","journal-title":"Microsystems & Nanoengineering"},{"key":"2026072808074477000_cit3","doi-asserted-by":"publisher","first-page":"340297","DOI":"10.1016\/j.aca.2022.340297","article-title":"Recent advances\nin airborne pathogen detection using\noptical and electrochemical biosensors","volume":"1234","author":"Sivakumar","year":"2022","journal-title":"Anal.\nChim. Acta"},{"issue":"3","key":"2026072808074477000_cit4","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1007\/s10453-024-09824-y","article-title":"On-site monitoring\nof airborne pathogens: recent advances in bioaerosol\ncollection and rapid detection","volume":"40","author":"Feng","year":"2024","journal-title":"Aerobiologia"},{"key":"2026072808074477000_cit5","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.3390\/molecules28041598","article-title":"On-Site Detection of Volatile Organic Compounds (VOCs)","volume":"28","author":"Epping","year":"2023","journal-title":"Molecules"},{"key":"2026072808074477000_cit6","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.jes.2021.08.055","article-title":"Roles of semivolatile\nand intermediate-volatility organic compounds in secondary organic\naerosol formation and its implication: A review","volume":"114","author":"Ling","year":"2022","journal-title":"Journal of Environmental Sciences"},{"key":"2026072808074477000_cit7","doi-asserted-by":"publisher","first-page":"444","DOI":"10.1016\/j.trac.2019.06.006","article-title":"Fast gas chromatography-mass spectrometry:\nA review of the last decade","volume":"118","author":"Zoccali","year":"2019","journal-title":"TrAC Trends in\nAnalytical Chemistry"},{"key":"2026072808074477000_cit8","doi-asserted-by":"publisher","first-page":"340561","DOI":"10.1016\/j.aca.2022.340561","article-title":"Selection of gas standards,\ngas chromatography\ncolumn and adsorbents for the measurement of very volatile organic\ncompounds (C1\u2013C6) in indoor air","volume":"1238","author":"Even","year":"2023","journal-title":"Anal.\nChim. Acta"},{"key":"2026072808074477000_cit9","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.aca.2019.03.027","article-title":"Evaluation\nof different adsorbent materials for the untargeted and targeted bacterial\nVOC analysis using GC\u00d7GC-MS","volume":"1066","author":"Franchina","year":"2019","journal-title":"Anal. Chim.\nActa"},{"issue":"10","key":"2026072808074477000_cit10","doi-asserted-by":"publisher","first-page":"6638","DOI":"10.1021\/acs.analchem.9b00560","article-title":"Assessment of the Quality of Doping\nSubstances Identification in Urine by GC\/MS\/MS","volume":"91","author":"Narciso","year":"2019","journal-title":"Anal. Chem."},{"key":"2026072808074477000_cit11","doi-asserted-by":"publisher","first-page":"115602","DOI":"10.1016\/j.fuel.2019.06.010","article-title":"Molecular\ncharacteristics of the soluble components from three low-rank coals\nbased on the analyses using GC\/MS and GC\/Q-TOF MS","volume":"254","author":"Li","year":"2019","journal-title":"Fuel"},{"issue":"3","key":"2026072808074477000_cit12","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.fmre.2023.05.012","article-title":"Recent progress in\nonline detection methods of bioaerosols","volume":"4","author":"An","year":"2024","journal-title":"Fundamental\nResearch"},{"issue":"3","key":"2026072808074477000_cit13","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.mimet.2008.11.002","article-title":"Use of broad range16S rDNA PCR in\nclinical microbiology","volume":"76","author":"Sontakke","year":"2009","journal-title":"J. Microbiol. Methods"},{"issue":"7","key":"2026072808074477000_cit14","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1515\/CCLM.2008.157","article-title":"Rapid methods for diagnosis of bloodstream infections","volume":"46","author":"Klouche","year":"2008","journal-title":"Clinical Chemistry and Laboratory Medicine"},{"issue":"4","key":"2026072808074477000_cit15","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1128\/CMR.17.4.840-862.2004","article-title":"Impact\nof 16S rRNA Gene Sequence Analysis for Identification of Bacteria\non Clinical Microbiology and Infectious Diseases","volume":"17","author":"Clarridge","year":"2004","journal-title":"Clin. Microbiol. Rev."},{"issue":"17","key":"2026072808074477000_cit16","doi-asserted-by":"publisher","first-page":"9111","DOI":"10.1021\/acs.analchem.5c01223","article-title":"Miniaturization\nof Mass Spectrometry Systems: An Overview of Recent Advancements and\na Perspective on Future Directions","volume":"97","author":"Fan","year":"2025","journal-title":"Anal. Chem."},{"issue":"1","key":"2026072808074477000_cit17","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1021\/acs.analchem.5b03070","article-title":"Miniature and Fieldable\nMass Spectrometers: Recent Advances","volume":"88","author":"Snyder","year":"2016","journal-title":"Anal. Chem."},{"issue":"22","key":"2026072808074477000_cit18","doi-asserted-by":"publisher","first-page":"11501","DOI":"10.1021\/acs.analchem.5b03269","article-title":"Vehicle-Mounted Portable Mass Spectrometry\nSystem for the Covert Detection via Spatial Analysis of Clandestine\nMethamphetamine Laboratories","volume":"87","author":"Mach","year":"2015","journal-title":"Anal. Chem."},{"issue":"3","key":"2026072808074477000_cit19","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1039\/D4AN01484G","article-title":"Development of a portable gas chromatograph\u2013mass spectrometer\nembedded with a low-temperature adsorption thermal desorption module\nfor enhanced detection of volatile organic compounds","volume":"150","author":"Chen","year":"2025","journal-title":"Analyst"},{"issue":"1","key":"2026072808074477000_cit20","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1002\/jms.768","article-title":"Miniaturized system\nof a gas chromatograph coupled with a Paul ion trap mass spectrometer","volume":"40","author":"Shortt","year":"2005","journal-title":"Journal of Mass Spectrometry"},{"key":"2026072808074477000_cit21","doi-asserted-by":"publisher","first-page":"122352","DOI":"10.1016\/j.talanta.2021.122352","article-title":"Development\nof membrane inlet photoionization\nion trap mass spectrometer for trace VOCs analysis","volume":"230","author":"Shi","year":"2021","journal-title":"Talanta"},{"key":"2026072808074477000_cit22","doi-asserted-by":"publisher","first-page":"125221","DOI":"10.1016\/j.talanta.2023.125221","article-title":"A homogeneous\nsampling membrane inlet photoelectron ionization miniature time-of-flight\nmass spectrometer for on-line determination of ethane","volume":"267","author":"Li","year":"2024","journal-title":"Talanta"},{"issue":"7","key":"2026072808074477000_cit23","doi-asserted-by":"publisher","first-page":"4177","DOI":"10.1021\/acs.analchem.7b00195","article-title":"Mini Mass Spectrometer Integrated with a Miniature Ion Funnel","volume":"89","author":"Zhai","year":"2017","journal-title":"Anal. Chem."},{"issue":"40","key":"2026072808074477000_cit24","doi-asserted-by":"publisher","first-page":"22350","DOI":"10.1021\/acs.analchem.5c04683","article-title":"Dual-Trap\n\u201cBrick\u201d Miniature Mass Spectrometer with Enhanced Sensitivity\nand Fragmentation Capabilities","volume":"97","author":"Ma","year":"2025","journal-title":"Anal. Chem."},{"issue":"3","key":"2026072808074477000_cit25","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1021\/acs.chemrestox.0c00444","article-title":"Direct Analysis Using Miniature Mass Spectrometers:\nA Fast On-Site Analytical Tool for Toxicology","volume":"34","author":"Wang","year":"2021","journal-title":"Chem. Res. Toxicol."},{"issue":"17","key":"2026072808074477000_cit26","doi-asserted-by":"publisher","first-page":"8867","DOI":"10.1021\/acs.analchem.5b01943","article-title":"Real-Time\nSample Analysis Using a Sampling Probe and Miniature Mass Spectrometer","volume":"87","author":"Chen","year":"2015","journal-title":"Anal. Chem."},{"key":"2026072808074477000_cit27","doi-asserted-by":"publisher","first-page":"128980","DOI":"10.1016\/j.talanta.2025.128980","article-title":"A new hybrid quadrupole-ion\ntrap operational mode for miniature mass spectrometer","volume":"298","author":"Ma","year":"2026","journal-title":"Talanta"},{"issue":"4","key":"2026072808074477000_cit28","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1021\/jasms.0c00019","article-title":"A \u201cBrick\u201d Mass Spectrometer with Photoionization for\nDirect Analysis of Trace Volatile Compounds","volume":"31","author":"Meng","year":"2020","journal-title":"J. Am. Soc. Mass Spectrom."},{"issue":"4","key":"2026072808074477000_cit29","doi-asserted-by":"publisher","first-page":"2086","DOI":"10.1021\/acs.analchem.4c04706","article-title":"Mesh-Collision Microtube Plasma Ion\nSource for Direct Mass Spectrometry Analysis","volume":"97","author":"Lv","year":"2025","journal-title":"Anal. Chem."},{"key":"2026072808074477000_cit30","doi-asserted-by":"publisher","first-page":"127155","DOI":"10.1016\/j.talanta.2024.127155","article-title":"Microwave plasma torch desorption\nionization mass spectrometry for chemical characterization of aromatic\nsecondary organic aerosol","volume":"283","author":"Yang","year":"2025","journal-title":"Talanta"},{"issue":"6","key":"2026072808074477000_cit31","doi-asserted-by":"publisher","first-page":"3845","DOI":"10.1021\/acs.analchem.8b04168","article-title":"Rapid On-Site Detection\nof Illegal Drugs in Complex Matrix by Thermal\nDesorption Acetone-Assisted Photoionization Miniature Ion Trap Mass\nSpectrometer","volume":"91","author":"Wang","year":"2019","journal-title":"Anal. Chem."},{"issue":"14","key":"2026072808074477000_cit32","doi-asserted-by":"publisher","first-page":"5686","DOI":"10.1021\/acs.analchem.4c00686","article-title":"Pressure-Driven\nSwitching of Photoelectron Impact Ionization-Chemical Ionization\/Penning\nIonization in Vacuum Ultraviolet Photoionization Mass Spectrometry","volume":"96","author":"Yu","year":"2024","journal-title":"Anal. Chem."},{"issue":"23","key":"2026072808074477000_cit33","doi-asserted-by":"publisher","first-page":"9325","DOI":"10.1021\/acs.analchem.4c01555","article-title":"Portable Mass\nSpectrometry for On-site Detection of Hazardous Volatile Organic Compounds\nvia Robotic Extractive Sampling","volume":"96","author":"Liu","year":"2024","journal-title":"Anal. Chem."},{"issue":"17","key":"2026072808074477000_cit34","doi-asserted-by":"publisher","first-page":"9126","DOI":"10.1021\/acs.analchem.5c01237","article-title":"Lab-on-Robot: Unmanned\nMass Spectrometry Robot for Direct Sample Analysis in Hazardous and\nRadioactive Environments","volume":"97","author":"Liu","year":"2025","journal-title":"Anal. Chem."},{"issue":"23","key":"2026072808074477000_cit35","doi-asserted-by":"publisher","first-page":"17100","DOI":"10.1021\/acs.est.2c05259","article-title":"Onsite Identification and Spatial\nDistribution of Air Pollutants Using a Drone-Based Solid-Phase Microextraction\nArray Coupled with Portable Gas Chromatography-Mass Spectrometry via\nContinuous-Airflow Sampling","volume":"56","author":"Chen","year":"2022","journal-title":"Environ. Sci. Technol."},{"issue":"36","key":"2026072808074477000_cit36","doi-asserted-by":"publisher","first-page":"19918","DOI":"10.1021\/acs.analchem.5c04149","article-title":"The Role of Aerosol Liquid Water in Droplet-Assisted\nIonization Mass Spectrometry","volume":"97","author":"Harrison","year":"2025","journal-title":"Anal. Chem."},{"issue":"38","key":"2026072808074477000_cit37","doi-asserted-by":"publisher","first-page":"14260","DOI":"10.1021\/acs.est.3c02895","article-title":"Peroxides on the\nSurface of Organic Aerosol Particles Using Matrix-Assisted Ionization\nin Vacuum (MAIV) Mass Spectrometry","volume":"57","author":"Qin","year":"2023","journal-title":"Environ.\nSci. Technol."},{"issue":"44","key":"2026072808074477000_cit38","doi-asserted-by":"publisher","first-page":"28220","DOI":"10.1039\/D4CP03597F","article-title":"Modeling\nthe ionization mechanism of amorphous solid particles without an external\nenergy source coupled to mass spectrometry","volume":"26","author":"Consta","year":"2024","journal-title":"Phys. Chem. Chem. Phys."},{"key":"2026072808074477000_cit39","doi-asserted-by":"publisher","first-page":"117981","DOI":"10.1016\/j.microc.2026.117981","article-title":"Preliminary characterization\nof a single-particle aerosol mass spectrometer\nwith fluorescence pre-selection capability","volume":"225","author":"Lu","year":"2026","journal-title":"Microchemical Journal"},{"issue":"4","key":"2026072808074477000_cit40","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1080\/02786826.2013.877579","article-title":"Performance of Two Fluorescence-Based\nReal-Time Bioaerosol Detectors: BioScout vs","volume":"48","author":"Saari","year":"2014","journal-title":"UVAPS. Aerosol Science and Technology"},{"issue":"22","key":"2026072808074477000_cit41","doi-asserted-by":"publisher","first-page":"13257","DOI":"10.1021\/acs.est.9b01862","article-title":"Size-Resolved\nSingle-Particle\nFluorescence Spectrometer for Real-Time Analysis of Bioaerosols: Laboratory\nEvaluation and Atmospheric Measurements","volume":"53","author":"Zhang","year":"2019","journal-title":"Environ.\nSci. Technol."},{"issue":"51","key":"2026072808074477000_cit42","doi-asserted-by":"publisher","first-page":"17861","DOI":"10.1021\/acs.analchem.2c03636","article-title":"Airborne Microbial\nAerosol Detection by Combining Single Particle Mass Spectrometry and\na Fluorescent Aerosol Particle Sizer","volume":"94","author":"Lu","year":"2022","journal-title":"Anal.\nChem."},{"key":"2026072808074477000_cit43","doi-asserted-by":"publisher","first-page":"116542","DOI":"10.1016\/j.trac.2022.116542","article-title":"Vacuum ultraviolet\nphotoionization on-line mass spectrometry: Instrumentation developments\nand applications","volume":"149","author":"Dang","year":"2022","journal-title":"TrAC Trends in Analytical\nChemistry"},{"issue":"11","key":"2026072808074477000_cit44","doi-asserted-by":"publisher","first-page":"4174","DOI":"10.1021\/ac8013675","article-title":"Light and\nMolecular Ions: The Emergence of Vacuum UV\nSingle-Photon Ionization in MS","volume":"81","author":"Hanley","year":"2009","journal-title":"Anal. Chem."},{"issue":"7","key":"2026072808074477000_cit45","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.1016\/S1872-2040(17)61028-4","article-title":"Development of Electrospray\/Photoionization\nMiniature Ion Trap Mass Spectrometer","volume":"45","author":"Qian","year":"2017","journal-title":"Chinese\nJournal of Analytical Chemistry"},{"issue":"10","key":"2026072808074477000_cit46","doi-asserted-by":"publisher","first-page":"6616","DOI":"10.1021\/acs.analchem.9b00520","article-title":"Imaging of Polar and Nonpolar Species\nUsing Compact Desorption Electrospray Ionization\/Postphotoionization\nMass Spectrometry","volume":"91","author":"Liu","year":"2019","journal-title":"Anal. Chem."},{"key":"2026072808074477000_cit47","doi-asserted-by":"publisher","first-page":"122380","DOI":"10.1016\/j.talanta.2021.122380","article-title":"Cholesterol was identified\nas a biomarker in human melanocytic nevi\nusing DESI and DESI\/PI mass spectrometry imaging","volume":"231","author":"Qi","year":"2021","journal-title":"Talanta"},{"issue":"6","key":"2026072808074477000_cit48","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1021\/jasms.4c00100","article-title":"A Miniature\nOrthogonal Injection Ion Funnel (MO-IF)\nProviding Enhanced Performance for the Miniature Mass Spectrometer","volume":"35","author":"Tu","year":"2024","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"2026072808074477000_cit49","doi-asserted-by":"publisher","first-page":"342344","DOI":"10.1016\/j.aca.2024.342344","article-title":"Detection\nof nanoplastics released from consumer plastic\nfood containers by electromagnetic heating pyrolysis mass spectrometry","volume":"1296","author":"Shi","year":"2024","journal-title":"Anal. Chim. Acta"},{"issue":"27","key":"2026072808074477000_cit50","doi-asserted-by":"publisher","first-page":"8065","DOI":"10.1039\/D2SC02569H","article-title":"Intact living-cell\nelectrolaunching ionization mass spectrometry for single-cell metabolomics","volume":"13","author":"Shao","year":"2022","journal-title":"Chemical Science"},{"issue":"9","key":"2026072808074477000_cit51","doi-asserted-by":"publisher","first-page":"2772","DOI":"10.3390\/molecules27092772","article-title":"Rapid Characterization\nof Bacterial Lipids with Ambient Ionization Mass Spectrometry for\nSpecies Differentiation","volume":"27","author":"Su","year":"2022","journal-title":"Molecules"},{"key":"2026072808074477000_cit52","doi-asserted-by":"publisher","first-page":"2333","DOI":"10.3390\/microorganisms10122333","article-title":"Multi-Temperatures\nPyrolysis Gas Chromatography: A Rapid Method to Differentiate Microorganisms","volume":"10","author":"Wan","year":"2022","journal-title":"Microorganisms"}],"container-title":["Analytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acs.analchem.6c03165","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/29\/21838\/65966844\/acs.analchem.6c03165.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/29\/21838\/65966844\/acs.analchem.6c03165.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T12:21:19Z","timestamp":1785241279000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/ancham\/article\/98\/29\/21838\/5211350\/A-Chemical-and-Biological-Portable-Mass"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,15]]},"references-count":52,"journal-issue":{"issue":"29","published-online":{"date-parts":[[2026,7,15]]},"published-print":{"date-parts":[[2026,7,28]]}},"URL":"https:\/\/doi.org\/10.1021\/acs.analchem.6c03165","relation":{},"ISSN":["0003-2700","1520-6882"],"issn-type":[{"value":"0003-2700","type":"print"},{"value":"1520-6882","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,15]]}}}