{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T13:56:42Z","timestamp":1791295002087,"version":"4.1.0"},"reference-count":43,"publisher":"American Chemical Society (ACS)","issue":"39","license":[{"start":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T00:00:00Z","timestamp":1789516800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"National Science Foundation (NSF) Center for Cell Manufacturing and Therapeutics (CMaT)","award":["1648035"],"award-info":[{"award-number":["1648035"]}]},{"name":"National Institutes of Health (NIH)","award":["5R01GM138802-03"],"award-info":[{"award-number":["5R01GM138802-03"]}]},{"name":"National Institutes of Health (NIH)","award":["5R01GM154933-02"],"award-info":[{"award-number":["5R01GM154933-02"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,10,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>A physics-based scaling framework to predict the outcomes of impingement-based mass spectrometry imaging (MSI) techniques is presented to understand the underlying mechanisms and guide performance improvements. Particular emphasis is placed on analyte extraction, the fundamental process that defines MSI resolution and the softness of ionization. Two distinct regimes, thermodynamic (passive) and kinematic (active), are identified that follow different physical laws. Thermodynamic desorption arises under conditions approaching thermal equilibrium, where molecules are extracted through favorable energetic interactions with the solvent phase. In contrast, kinematic desorption occurs when high-energy particles or droplets impact the sample, supplying mechanical energy to overcome the cohesive forces that bind molecules at the surface. A dimensionless parameter is developed that compares the stress generated by an impacting particle to the cohesive forces binding molecules within a sample, providing a criterion for identifying transitions among extraction regimes. Through a scaling analysis of charged particle transport and impact dynamics, this parameter is expressed in terms of experimentally controllable inputs, revealing that kinematic extraction becomes possible only when the accelerating electric force exceeds the combined effects of the aerodynamic drag and particle inertia. Application of the methodology to representative MSI techniques yields predictions consistent with experimentally observed extraction behaviors, which supports the proposed mechanistic interpretation. More broadly, this framework establishes a semiquantitative foundation for predicting molecular extraction across a wide range of solution- and impingement-based MSI platforms, enabling systematic exploration of performance limits and guiding the design of next-generation MSI technologies using fundamental experimentally measured properties.<\/jats:p>","DOI":"10.1021\/acs.analchem.6c03821","type":"journal-article","created":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T21:01:56Z","timestamp":1789592516000},"page":"28617-28622","source":"Crossref","is-referenced-by-count":0,"title":["Predicting\nOutcomes of Impingement-Based Mass Spectrometry\nImaging"],"prefix":"10.1021","volume":"98","author":[{"given":"John C.","family":"Sentmanat","sequence":"first","affiliation":[{"name":"Georgia Institute of Technology , , , ,","place":["Atlanta, Georgia, United States, 30332"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0859-2541","authenticated-orcid":true,"given":"Andrei G.","family":"Fedorov","sequence":"additional","affiliation":[{"name":"Georgia Institute of Technology , , , ,","place":["Atlanta, Georgia, United States, 30332"]},{"name":"Georgia Institute of Technology , , , ,","place":["Atlanta, Georgia, United States, 30332"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,9,16]]},"reference":[{"key":"2026100608080438700_cit1","doi-asserted-by":"publisher","first-page":"782432","DOI":"10.3389\/fchem.2021.782432","article-title":"Advances in MALDI mass spectrometry\nimaging single cell and tissues","volume":"9","author":"Zhu","year":"2022","journal-title":"Frontiers in\nChemistry"},{"issue":"18","key":"2026100608080438700_cit2","doi-asserted-by":"publisher","first-page":"4093","DOI":"10.1007\/s00216-023-04774-9","article-title":"Recent advances in mass spectrometry\nimaging of single cells","volume":"415","author":"Liu","year":"2023","journal-title":"Anal. Bioanal. Chem."},{"issue":"2","key":"2026100608080438700_cit3","doi-asserted-by":"publisher","first-page":"S0059","DOI":"10.5702\/massspectrometry.S0059","article-title":"Desorption\nin mass spectrometry","volume":"6","author":"Usmanov","year":"2017","journal-title":"Mass Spectrometry"},{"issue":"24","key":"2026100608080438700_cit4","doi-asserted-by":"publisher","first-page":"8549","DOI":"10.1021\/ac0615807","article-title":"Droplet dynamics and ionization mechanisms\nin desorption electrospray ionization mass spectrometry","volume":"78","author":"Venter","year":"2006","journal-title":"Anal. Chem."},{"issue":"1\u20133","key":"2026100608080438700_cit5","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.cplett.2008.08.020","article-title":"Simulated splashes:\nElucidating the mechanism of desorption\nelectrospray ionization mass spectrometry","volume":"464","author":"Costa","year":"2008","journal-title":"Chem.\nPhys. Lett."},{"key":"2026100608080438700_cit6","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1016\/j.jasms.2009.12.012","article-title":"Non-aqueous\nspray\nsolvents and solubility effects in desorption electrospray ionization","volume":"21","author":"Badu-Tawiah","year":"2010","journal-title":"J. Am. Soc. Mass Spectrom."},{"key":"2026100608080438700_cit7","doi-asserted-by":"publisher","first-page":"3967","DOI":"10.1007\/s00216-020-02671-z","article-title":"The role of surface in desorption\nelectrospray ionization-mass spectrometry: advances and future trends","volume":"412","author":"Bianchi","year":"2020","journal-title":"Anal. Bioanal. Chem."},{"issue":"4","key":"2026100608080438700_cit8","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/1044-0305(92)87058-7","article-title":"Shock wave\nmodel for sputtering biomolecules using massive cluster impacts","volume":"3","author":"Mahoney","year":"1992","journal-title":"J. Am. Soc. Mass Spectrom."},{"issue":"5","key":"2026100608080438700_cit9","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1002\/rcm.4909","article-title":"Study of the desorption\/ionization\nmechanism in electrospray\ndroplet impact secondary ion mass spectrometry","volume":"25","author":"Asakawa","year":"2011","journal-title":"Rapid Commun. Mass Spectrom."},{"issue":"12","key":"2026100608080438700_cit10","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1002\/rcm.1290081218","article-title":"Matrix-free\ndesorption of biomolecules using massive cluster impact","volume":"8","author":"Shannon Cornett","year":"1994","journal-title":"Rapid Commun. Mass Spectrom."},{"issue":"38","key":"2026100608080438700_cit11","doi-asserted-by":"publisher","first-page":"12462","DOI":"10.1021\/ja0624321","article-title":"Lipids out of equilibrium:\nEnergetics of desorption\nand pore mediated flip-flop","volume":"128","author":"Tieleman","year":"2006","journal-title":"J. Am. Chem. Soc."},{"issue":"17","key":"2026100608080438700_cit12","doi-asserted-by":"publisher","first-page":"3295","DOI":"10.1039\/b902376c","article-title":"Thermodynamics\nof flip-flop and desorption\nfor a systematic series of phosphatidylcholine lipids","volume":"5","author":"Sapay","year":"2009","journal-title":"Soft Matter"},{"issue":"6","key":"2026100608080438700_cit13","doi-asserted-by":"publisher","first-page":"707","DOI":"10.2514\/3.61409","article-title":"Drag coefficients\nof spheres in continuum and rarefied flows","volume":"14","author":"Henderson","year":"1976","journal-title":"AIAA J."},{"issue":"11","key":"2026100608080438700_cit14","doi-asserted-by":"publisher","first-page":"114303","DOI":"10.1103\/yydh-dgyw","article-title":"Charged droplet manipulation by gas\njets at sub-atmospheric pressures","volume":"10","author":"Sentmanat","year":"2025","journal-title":"Physical\nReview Fluids"},{"issue":"7","key":"2026100608080438700_cit15","doi-asserted-by":"publisher","first-page":"894","DOI":"10.1002\/jms.1048","article-title":"Fundamental\naspects of electrospray\ndroplet impact\/SIMS","volume":"41","author":"Hiraoka","year":"2006","journal-title":"Journal of mass spectrometry"},{"issue":"15","key":"2026100608080438700_cit16","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1002\/rcm.7240","article-title":"Electrospray droplet impact secondary\nion mass spectrometry using a vacuum electrospray source","volume":"29","author":"Takaishi","year":"2015","journal-title":"Rapid Commun. Mass Spectrom."},{"issue":"4","key":"2026100608080438700_cit17","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1016\/j.apsusc.2008.05.146","article-title":"Energy dependence\nof projectiles\non ion formation in electrospray droplet impact SIMS","volume":"255","author":"Asakawa","year":"2008","journal-title":"Appl. Surf. Sci."},{"issue":"10","key":"2026100608080438700_cit18","doi-asserted-by":"publisher","first-page":"1579","DOI":"10.1002\/rcm.3004","article-title":"Study on ion\nformation in electrospray droplet impact secondary ion mass spectrometry","volume":"21","author":"Asakawa","year":"2007","journal-title":"Rapid Commun. Mass Spectrom."},{"key":"2026100608080438700_cit19","doi-asserted-by":"publisher","first-page":"116993","DOI":"10.1016\/j.ijms.2022.116993","article-title":"Electrospray\ndroplet impact\/secondary ion mass spectrometry (EDI\/SIMS) applied\nto the analysis of explosives","volume":"484","author":"Hiraoka","year":"2023","journal-title":"Int. J. Mass\nSpectrom."},{"issue":"10","key":"2026100608080438700_cit20","doi-asserted-by":"publisher","first-page":"3793","DOI":"10.1021\/ac200288v","article-title":"TOF-SIMS\nwith argon gas cluster ion beams: a comparison with C60+","volume":"83","author":"Rabbani","year":"2011","journal-title":"Analytical chemistry"},{"issue":"23","key":"2026100608080438700_cit21","doi-asserted-by":"publisher","first-page":"9058","DOI":"10.1021\/ac8015278","article-title":"A new dynamic\nin mass spectral imaging of single biological cells","volume":"80","author":"Fletcher","year":"2008","journal-title":"Anal. Chem."},{"issue":"13","key":"2026100608080438700_cit22","doi-asserted-by":"publisher","first-page":"7186","DOI":"10.1021\/acs.analchem.4c06594","article-title":"Mapping the Molecular Landscape of\nHuman DLBCL by GCIB-SIMS","volume":"97","author":"Uzoni","year":"2025","journal-title":"Anal. Chem."},{"issue":"23","key":"2026100608080438700_cit23","doi-asserted-by":"publisher","first-page":"8143","DOI":"10.1021\/acs.analchem.0c05311","article-title":"Successive\nhigh-resolution (H2O) n-GCIB and C60-SIMS imaging integrates multi-omics\nin different cell types in breast cancer tissue","volume":"93","author":"Tian","year":"2021","journal-title":"Anal. Chem."},{"issue":"1\u20132","key":"2026100608080438700_cit24","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/0168-583X(94)96096-8","article-title":"Large biomolecule desorption\nby massive\ncluster impact","volume":"88","author":"Mahoney","year":"1994","journal-title":"Nuclear Instruments and Methods\nin Physics Research Section B: Beam Interactions with Materials and\nAtoms"},{"issue":"21","key":"2026100608080438700_cit25","doi-asserted-by":"publisher","first-page":"12692","DOI":"10.1021\/acs.analchem.8b02950","article-title":"Molecular\ncolocalization using massive gold cluster secondary ion mass spectrometry","volume":"90","author":"Eller","year":"2018","journal-title":"Analytical chemistry"},{"issue":"17","key":"2026100608080438700_cit26","doi-asserted-by":"publisher","first-page":"2639","DOI":"10.1002\/rcm.3662","article-title":"Improved\nimaging resolution in desorption electrospray\nionization mass spectrometry","volume":"22","author":"Kertesz","year":"2008","journal-title":"Rapid Communications\nin Mass Spectrometry: An International Journal Devoted to the Rapid\nDissemination of Up-to-the-Minute Research in Mass Spectrometry"},{"issue":"13","key":"2026100608080438700_cit27","doi-asserted-by":"publisher","first-page":"7785","DOI":"10.1021\/acs.analchem.8b00967","article-title":"Desorption electrospray\nionization\nmass spectrometry imaging of proteins directly from biological tissue\nsections","volume":"90","author":"Garza","year":"2018","journal-title":"Analytical chemistry"},{"issue":"11","key":"2026100608080438700_cit28","doi-asserted-by":"publisher","first-page":"1896","DOI":"10.1007\/s13361-012-0468-x","article-title":"Deconstructing desorption\nelectrospray ionization: independent optimization of desorption and\nionization by spray desorption collection","volume":"23","author":"Douglass","year":"2012","journal-title":"Journal\nof The American Society for Mass Spectrometry"},{"issue":"9","key":"2026100608080438700_cit29","doi-asserted-by":"publisher","first-page":"1186","DOI":"10.1002\/jms.1250","article-title":"Desorption\nelectrospray ionization mass spectrometry of intact bacteria","volume":"42","author":"Meetani","year":"2007","journal-title":"Journal of mass spectrometry"},{"issue":"6","key":"2026100608080438700_cit30","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.jasms.2007.03.006","article-title":"Detection of attomole\namounts of analyte by desorption\nelectrospray ionization mass spectrometry (DESI-MS) determined using\nfluorescence spectroscopy","volume":"18","author":"Bereman","year":"2007","journal-title":"J. Am. Soc. Mass\nSpectrom."},{"issue":"4","key":"2026100608080438700_cit31","doi-asserted-by":"publisher","first-page":"1027","DOI":"10.1021\/ac701947d","article-title":"Scanning and surface alignment considerations\nin chemical\nimaging with desorption electrospray mass spectrometry","volume":"80","author":"Kertesz","year":"2008","journal-title":"Analytical chemistry"},{"key":"2026100608080438700_cit32","doi-asserted-by":"publisher","first-page":"9985","DOI":"10.1021\/acs.analchem.5c00843","article-title":"Delineation of Subcellular Molecular\nHeterogeneity in Single Cells via Ultralow-Flow-Rate Desorption Electrospray\nIonization Mass Spectrometry Imaging","volume":"97","author":"Zhang","year":"2025","journal-title":"Anal.\nChem."},{"issue":"27","key":"2026100608080438700_cit33","doi-asserted-by":"publisher","first-page":"9690","DOI":"10.1021\/acs.analchem.2c01093","article-title":"High-throughput nano-DESI\nmass spectrometry imaging\nof biological tissues using an integrated microfluidic probe","volume":"94","author":"Li","year":"2022","journal-title":"Analytical chemistry"},{"issue":"4","key":"2026100608080438700_cit34","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1002\/jms.1340","article-title":"Liquid microjunction surface sampling\nprobe electrospray mass spectrometry for detection of drugs and metabolites\nin thin tissue sections","volume":"43","author":"Van Berkel","year":"2008","journal-title":"Journal of mass spectrometry"},{"issue":"7","key":"2026100608080438700_cit35","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1021\/ac026338o","article-title":"A C60 primary\nion beam system for\ntime of flight secondary ion mass spectrometry: its development and\nsecondary ion yield characteristics","volume":"75","author":"Weibel","year":"2003","journal-title":"Anal. Chem."},{"issue":"13","key":"2026100608080438700_cit36","doi-asserted-by":"publisher","first-page":"1851","DOI":"10.1002\/rcm.1995","article-title":"The Aun cluster\nprobe in secondary ion mass spectrometry:\nInfluence of the projectile size and energy on the desorption\/ionization\nrate from biomolecular solids","volume":"19","author":"Novikov","year":"2005","journal-title":"Rapid Communications\nin Mass Spectrometry: An International Journal Devoted to the Rapid\nDissemination of Up-to-the-Minute Research in Mass Spectrometry"},{"issue":"1\u20133","key":"2026100608080438700_cit37","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/S1387-3806(00)00245-1","article-title":"Ion detection efficiency\nin SIMS:: Dependencies on energy, mass and\ncomposition for microchannel plates used in mass spectrometry","volume":"202","author":"Gilmore","year":"2000","journal-title":"Int. J. Mass Spectrom."},{"issue":"10","key":"2026100608080438700_cit38","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1007\/s13361-011-0188-7","article-title":"Evidence of\nMolecular Fragmentation\ninside the Charged Droplets Produced by Electrospray Process","volume":"22","author":"Banerjee","year":"2011","journal-title":"J. Am. Soc. Mass Spectrom."},{"issue":"1","key":"2026100608080438700_cit39","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1021\/ac302789c","article-title":"Unraveling the Mechanism\nof Electrospray Ionization","volume":"85","author":"Konermann","year":"2013","journal-title":"Anal. Chem."},{"issue":"1","key":"2026100608080438700_cit40","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/0146-5724(82)90056-5","article-title":"The role of excited electronic states\nin ion fragmentation: C6H6+","volume":"20","author":"Rosenstock","year":"1982","journal-title":"Radiation Physics\nand Chemistry (1977)"},{"issue":"5","key":"2026100608080438700_cit41","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1002\/(SICI)1096-9888(199605)31:5&lt;445::AID-JMS354&gt;3.0.CO;2-G","article-title":"Internal energy\neffects in mass spectrometry","volume":"31","author":"Ve\u0301key","year":"1996","journal-title":"Journal of mass\nspectrometry"},{"issue":"8","key":"2026100608080438700_cit42","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1002\/1096-9888(200008)35:8&lt;1035::AID-JMS34&gt;3.0.CO;2-V","article-title":"Internal energies\nof analyte ions\ngenerated from different matrix-assisted laser desorption\/ionization\nmatrices","volume":"35","author":"Stevenson","year":"2000","journal-title":"Journal of Mass Spectrometry"},{"key":"2026100608080438700_cit43","doi-asserted-by":"crossref","unstructured":"Fedorov, A.; Sentmanat, J.; Choe, K.\n          BeamMap: Beam Enabled Accurate\nMapping and Molecular\nAnalyte Profiling for topography and biochemistry spatial correlation.  Research Square Preprint, 2026. 10.21203\/rs.3.rs-8832802\/v1.","DOI":"10.21203\/rs.3.rs-8832802\/v1"}],"container-title":["Analytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acs.analchem.6c03821","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/39\/28617\/68538442\/acs.analchem.6c03821.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/ancham\/article-pdf\/98\/39\/28617\/68538442\/acs.analchem.6c03821.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T13:09:40Z","timestamp":1791292180000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/ancham\/article\/98\/39\/28617\/5431698\/Predicting-Outcomes-of-Impingement-Based-Mass"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,16]]},"references-count":43,"journal-issue":{"issue":"39","published-online":{"date-parts":[[2026,9,16]]},"published-print":{"date-parts":[[2026,10,6]]}},"URL":"https:\/\/doi.org\/10.1021\/acs.analchem.6c03821","relation":{},"ISSN":["0003-2700","1520-6882"],"issn-type":[{"value":"0003-2700","type":"print"},{"value":"1520-6882","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,16]]}}}