{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T12:53:36Z","timestamp":1791550416554,"version":"4.3.4"},"reference-count":33,"publisher":"American Chemical Society (ACS)","issue":"10","license":[{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000139","name":"U.S. Environmental Protection Agency","doi-asserted-by":"publisher","award":["5X-953114401"],"award-info":[{"award-number":["5X-953114401"]}],"id":[{"id":"10.13039\/100000139","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100007226","name":"Villanova University","doi-asserted-by":"publisher","award":["NA"],"award-info":[{"award-number":["NA"]}],"id":[{"id":"10.13039\/100007226","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,10,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Low-cost sensors (LCS), such as PurpleAir (PA), are widely used for measuring fine particulate matter (PM2.5) because they are inexpensive, easy to deploy, and provide publicly accessible data. However, PA sensors are known to overestimate PM2.5, and thus, several correction methods have been developed to improve their accuracy. In this study, we evaluated accuracy by comparing nationwide and locally derived correction methods during summer and spring seasons, examined PA output data types, assessed the influence of relative humidity using both PA and weather station data, and analyzed the performance after one year of field deployment. In the moderate climate of Philadelphia, the nationwide correction of Barkjohn et al. (2021) combined with using the mean value of two PAatm data outputs (RMSE = 1.640 \u03bcg\/m3, MBE = 0.103 \u03bcg\/m3, R2 = 0.683) for both 1 h and 24 h measurements provided the highest accuracy. Relative humidity measurements, whether obtained from a weather station or the PA sensor, had minimal effect on PM2.5 accuracy (difference in R2 = 0.04). PA sensor accuracy declined after one year of use (R2 = 0.567), showing requiring extra sensor calibration in long-term deployment. This methodology enhances the performance of PA sensors and establishes greater trust in the LCS.<\/jats:p>","DOI":"10.1021\/acsestair.5c00443","type":"journal-article","created":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T09:01:13Z","timestamp":1789722073000},"page":"2503-2512","source":"Crossref","is-referenced-by-count":0,"title":["Validation of\nPurpleAir PM2.5 Sensors in\nTemperate Urban Environments"],"prefix":"10.1021","volume":"3","author":[{"given":"Charles C.","family":"Sylvester","sequence":"first","affiliation":[{"name":"Villanova University , , 800 Lancaster Avenue , , ,","place":["Villanova, Pennsylvania, United States, 19085"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathaniel D.","family":"Hauenstein","sequence":"additional","affiliation":[{"name":"Villanova University , , 800 Lancaster Avenue , , ,","place":["Villanova, Pennsylvania, United States, 19085"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7035-7019","authenticated-orcid":true,"given":"Kabindra M.","family":"Shakya","sequence":"additional","affiliation":[{"name":"Villanova University , , 800 Lancaster Avenue , , ,","place":["Villanova, Pennsylvania, United States, 19085"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,9,18]]},"reference":[{"issue":"7","key":"2026100908071791700_cit1","doi-asserted-by":"publisher","first-page":"4615","DOI":"10.5194\/acp-22-4615-2022","article-title":"Advances in Air Quality Research \u2013 Current and\nEmerging Challenges","volume":"22","author":"Sokhi","year":"2022","journal-title":"Atmos. Chem. Phys."},{"issue":"9","key":"2026100908071791700_cit2","doi-asserted-by":"publisher","first-page":"506","DOI":"10.3390\/atmos10090506","article-title":"Review of\nthe Performance of Low-Cost Sensors for Air Quality Monitoring","volume":"10","author":"Karagulian","year":"2019","journal-title":"Atmosphere"},{"key":"2026100908071791700_cit3","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1016\/j.envint.2016.12.007","article-title":"Can Commercial\nLow-Cost Sensor Platforms Contribute to Air Quality Monitoring and\nExposure Estimates?","volume":"99","author":"Castell","year":"2017","journal-title":"Environ. Int."},{"issue":"5","key":"2026100908071791700_cit4","doi-asserted-by":"publisher","first-page":"2843","DOI":"10.1021\/acs.est.1c01739","article-title":"Selecting Data Analytic\nand Modeling\nMethods to Support Air Pollution and Environmental Justice Investigations:\nA Critical Review and Guidance Framework","volume":"56","author":"Gardner-Frolick","year":"2022","journal-title":"Environ.\nSci. Technol."},{"key":"2026100908071791700_cit5","unstructured":"PurpleAir.\n          \n          Real-time Air Quality Monitoring by PurpleAir. https:\/\/www2.purpleair.com\/. 2024. (accessed October 10, 2024)."},{"key":"2026100908071791700_cit6","unstructured":"PurpleAir Community.\n          \n          What is the Difference between CF\n= 1, ATM, and ALT? - Data\/API. 2023. https:\/\/community.purpleair.com\/t\/what-is-the-difference-between-cf-1-atm-and-alt\/6442 (accessed October 07, 2024)."},{"key":"2026100908071791700_cit7","doi-asserted-by":"publisher","first-page":"117067","DOI":"10.1016\/j.atmosenv.2019.117067","article-title":"Laboratory Evaluation\nof Low-Cost PurpleAir PM Monitors and in-Field Correction Using Co-Located\nPortable Filter Samplers","volume":"220","author":"Tryner","year":"2020","journal-title":"Atmos. Environ."},{"issue":"3","key":"2026100908071791700_cit8","doi-asserted-by":"publisher","first-page":"1934","DOI":"10.3390\/ijerph20031934","article-title":"Efficacy of Low-Cost\nSensor Networks at Detecting Fine-Scale Variations in Particulate\nMatter in Urban Environments","volume":"20","author":"Heintzelman","year":"2023","journal-title":"Int. J. Environ.\nRes. Public Health"},{"issue":"9","key":"2026100908071791700_cit9","doi-asserted-by":"publisher","first-page":"926","DOI":"10.3390\/atmos11090926","article-title":"Field Evaluation of Low-Cost PM Sensors\n(Purple Air PA-II) Under Variable Urban Air Quality Conditions, in\nGreece","volume":"11","author":"Stavroulas","year":"2020","journal-title":"Atmosphere"},{"key":"2026100908071791700_cit10","doi-asserted-by":"publisher","first-page":"118432","DOI":"10.1016\/j.atmosenv.2021.118432","article-title":"Calibration of Low-Cost\nPurpleAir Outdoor Monitors Using an Improved Method of Calculating\nPM2.5","volume":"256","author":"Wallace","year":"2021","journal-title":"Atmos. Environ."},{"issue":"12","key":"2026100908071791700_cit11","doi-asserted-by":"publisher","first-page":"3946","DOI":"10.3390\/s24123946","article-title":"Performance Assessment of Two Low-Cost PM2.5 and PM10 Monitoring\nNetworks in the Padana Plain (Italy)","volume":"24","author":"Gualtieri","year":"2024","journal-title":"Sensors"},{"issue":"3","key":"2026100908071791700_cit12","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1021\/acs.estlett.3c00030","article-title":"Size-Resolved Field Performance of\nLow-Cost Sensors for Particulate Matter Air Pollution","volume":"10","author":"Molina Rueda","year":"2023","journal-title":"Environ. Sci. Technol. Lett."},{"issue":"6","key":"2026100908071791700_cit13","doi-asserted-by":"publisher","first-page":"4617","DOI":"10.5194\/amt-14-4617-2021","article-title":"Development and\nApplication of a\nUnited States-Wide Correction for PM2.5 Data Collected\nwith the PurpleAir Sensor","volume":"14","author":"Barkjohn","year":"2021","journal-title":"Atmos. Meas. Tech."},{"issue":"2","key":"2026100908071791700_cit14","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1080\/02786826.2019.1623863","article-title":"Fine Particle\nMass Monitoring with\nLow-Cost Sensors: Corrections and Long-Term Performance Evaluation","volume":"54","author":"Malings","year":"2020","journal-title":"Aerosol Sci. Technol."},{"issue":"13","key":"2026100908071791700_cit15","doi-asserted-by":"publisher","first-page":"3135","DOI":"10.5194\/amt-18-3135-2025","article-title":"Retrieval of Bulk\nHygroscopicity\nfrom PurpleAir PM2.5 Sensor Measurements","volume":"18","author":"Psotka","year":"2025","journal-title":"Atmos. Meas. Tech."},{"key":"2026100908071791700_cit16","doi-asserted-by":"publisher","first-page":"119944","DOI":"10.1016\/j.atmosenv.2023.119944","article-title":"Evaluation\nof Calibration Approaches for Indoor Deployments of PurpleAir Monitors","volume":"310","author":"Koehler","year":"2023","journal-title":"Atmos. Environ."},{"issue":"10","key":"2026100908071791700_cit17","doi-asserted-by":"publisher","first-page":"5441","DOI":"10.5194\/amt-13-5441-2020","article-title":"Measurements of PM2.5 with PurpleAir under\nAtmospheric Conditions","volume":"13","author":"Ardon-Dryer","year":"2020","journal-title":"Atmos. Meas. Tech."},{"issue":"22","key":"2026100908071791700_cit18","doi-asserted-by":"publisher","first-page":"6735","DOI":"10.5194\/amt-17-6735-2024","article-title":"Calibration of PurpleAir Low-Cost\nParticulate Matter Sensors: Model Development for Air Quality under\nHigh Relative Humidity Conditions","volume":"17","author":"Mathieu-Campbell","year":"2024","journal-title":"Atmos. Meas.\nTech."},{"issue":"7","key":"2026100908071791700_cit19","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.1021\/acsestair.5c00018","article-title":"Unveiling\nthe Limits of Existing Correction Factors for a Low-Cost PM2.5 Sensor\nin Cold Environments and Development of a Tailored Solution","volume":"2","author":"Leenose","year":"2025","journal-title":"ACS ES&T Air"},{"key":"2026100908071791700_cit20","unstructured":"PurpleAir Community.\n          \n          PurpleAir Sensors Functional Overview\n- Sensors. 2021. https:\/\/community.purpleair.com\/t\/purpleair-sensors-functional-overview\/150 (accessed October 10, 2024)."},{"issue":"4","key":"2026100908071791700_cit21","doi-asserted-by":"publisher","first-page":"415","DOI":"10.3390\/atmos15040415","article-title":"Evaluation and Correction of PurpleAir\nTemperature and Relative Humidity Measurements","volume":"15","author":"Couzo","year":"2024","journal-title":"Atmosphere"},{"issue":"4","key":"2026100908071791700_cit22","doi-asserted-by":"publisher","first-page":"477","DOI":"10.3390\/pollutants3040033","article-title":"Long-Term\nAssessment of PurpleAir\nLow-Cost Sensor for PM2.5 in California, USA","volume":"3","author":"Farooqui","year":"2023","journal-title":"Pollutants"},{"key":"2026100908071791700_cit23","doi-asserted-by":"publisher","first-page":"128362","DOI":"10.1016\/j.envpol.2026.128362","article-title":"Characterization\nof Indoor and Outdoor Urban Particle and Gas Pollution at Neighborhood\nScale in Philadelphia, Pennsylvania","volume":"402","author":"Sylvester","year":"2026","journal-title":"Environ.\nPollut."},{"key":"2026100908071791700_cit24","unstructured":"City of Philadelphia Air Management Services.\n          . 2023-2024 Air Monitoring\nNetwork Plan, 2023. https:\/\/www.phila.gov\/documents\/air-management-reports-and-documents\/ (accessed July 10, 2025)."},{"key":"2026100908071791700_cit25","unstructured":"National Oceanic and Atmospheric Administration.\n          . Geographical\nReference Maps | U.S. Climate Regions | National Centers for Environmental\nInformation (NCEI). https:\/\/www.ncei.noaa.gov\/access\/monitoring\/reference-maps\/us-climate-regions. 2025. (accessed September 22, 2025)."},{"issue":"20","key":"2026100908071791700_cit26","doi-asserted-by":"publisher","first-page":"3329","DOI":"10.1016\/j.atmosenv.2004.03.007","article-title":"Performance Evaluation\nof the Active-Flow Personal DataRAM PM2.5 Mass Monitor (Thermo Anderson\npDR-1200) Designed for Continuous Personal Exposure Measurements","volume":"38","author":"Chakrabarti","year":"2004","journal-title":"Atmos. Environ."},{"issue":"24","key":"2026100908071791700_cit27","doi-asserted-by":"publisher","first-page":"9669","DOI":"10.3390\/s22249669","article-title":"Correction and Accuracy\nof PurpleAir PM2.5 Measurements for Extreme Wildfire Smoke","volume":"22","author":"Barkjohn","year":"2022","journal-title":"Sensors"},{"key":"2026100908071791700_cit28","doi-asserted-by":"publisher","first-page":"105872","DOI":"10.1016\/j.jaerosci.2021.105872","article-title":"Tutorial:\nGuidelines for Implementing Low-Cost Sensor Networks for Aerosol Monitoring","volume":"159","author":"Zimmerman","year":"2022","journal-title":"J. Aerosol Sci."},{"issue":"10","key":"2026100908071791700_cit29","doi-asserted-by":"publisher","first-page":"1915","DOI":"10.1029\/2019EA000717","article-title":"Distinct Impacts\nof\nLight and Heavy Precipitation on PM2.5 Mass Concentration in Beijing","volume":"6","author":"Sun","year":"2019","journal-title":"Earth Space Sci."},{"key":"2026100908071791700_cit30","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1038\/s41370-024-00677-8","article-title":"Practical Considerations for Using\nLow-Cost Sensors to Assess Wildfire Smoke Exposure in School and Childcare\nSettings","volume":"35","author":"Stampfer","year":"2024","journal-title":"J. Exposure Sci. Environ. Epidemiol."},{"issue":"4","key":"2026100908071791700_cit31","doi-asserted-by":"publisher","first-page":"2152","DOI":"10.1021\/acs.est.9b06046","article-title":"Incorporating Low-Cost\nSensor Measurements into High-Resolution PM2.5 Modeling\nat a Large Spatial Scale","volume":"54","author":"Bi","year":"2020","journal-title":"Environ. Sci. Technol."},{"issue":"29","key":"2026100908071791700_cit32","doi-asserted-by":"publisher","first-page":"10708","DOI":"10.1021\/acs.est.2c09264","article-title":"Low-Cost\nSensor Performance Intercomparison,\nCorrection Factor Development, and 2+ Years of Ambient PM2.5 Monitoring\nin Accra, Ghana","volume":"57","author":"Raheja","year":"2023","journal-title":"Environ. Sci. Technol."},{"key":"2026100908071791700_cit33","doi-asserted-by":"publisher","first-page":"121118","DOI":"10.1016\/j.atmosenv.2025.121118","article-title":"Deep Learning\nCalibration Model for\nPurpleAir PM2.5 Measurements: Comprehensive Investigation of the PurpleAir\nNetwork","volume":"348","author":"Ghahremanloo","year":"2025","journal-title":"Atmos. Environ."}],"container-title":["ACS ES&amp;T Air"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acsestair.5c00443","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/aeacd5\/article-pdf\/3\/10\/2503\/68552396\/acsestair.5c00443.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/aeacd5\/article-pdf\/3\/10\/2503\/68552396\/acsestair.5c00443.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T12:13:55Z","timestamp":1791548035000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/aeacd5\/article\/3\/10\/2503\/5432506\/Validation-of-PurpleAir-PM2-5-Sensors-in-Temperate"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,18]]},"references-count":33,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,9,18]]},"published-print":{"date-parts":[[2026,10,9]]}},"URL":"https:\/\/doi.org\/10.1021\/acsestair.5c00443","relation":{},"ISSN":["2837-1402"],"issn-type":[{"value":"2837-1402","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,18]]}}}