{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T20:22:41Z","timestamp":1790194961869,"version":"4.1.0"},"reference-count":33,"publisher":"American Chemical Society (ACS)","issue":"7","license":[{"start":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T00:00:00Z","timestamp":1773619200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004359","name":"Vetenskapsr\u00e5det","doi-asserted-by":"publisher","award":["2023-04808"],"award-info":[{"award-number":["2023-04808"]}],"id":[{"id":"10.13039\/501100004359","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100014440","name":"Ministerio de Ciencia, Innovaci\u00f3n y Universidades","doi-asserted-by":"publisher","award":["PID2023-147560OA-I00"],"award-info":[{"award-number":["PID2023-147560OA-I00"]}],"id":[{"id":"10.13039\/100014440","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100011033","name":"Agencia Estatal de Investigaci\u00f3n","doi-asserted-by":"publisher","award":["PID2022-140418NA-I00"],"award-info":[{"award-number":["PID2022-140418NA-I00"]}],"id":[{"id":"10.13039\/501100011033","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008530","name":"European Regional Development Fund","doi-asserted-by":"publisher","award":["PID2022-140418NA-I00"],"award-info":[{"award-number":["PID2022-140418NA-I00"]}],"id":[{"id":"10.13039\/501100008530","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,7,24]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Herein, we have developed a microneedle-based oxygen sensor wearable patch (O2 MN) designed for real-time, minimally invasive detection of dermal ISF oxygen levels. This work pioneers the use of platinum nanoparticles as the sensing element for oxygen detection within a microneedle platform, enabling high electrochemical sensitivity at a mild applied potential. The wearable patch integrates the nanoparticle-based microneedle as the working electrode and a Ag\/AgCl ink-modified microneedle as the counter\/reference electrode, operating at an applied potential of \u22120.3 V to detect a wide range of oxygen (10\u2013254 \u03bcM) with high sensitivity (\u22120.51 nA \u03bcM\u22121) and a rapid response time (9 s). The analytical assessment revealed excellent performance, including high reversibility (RSD = 3.4%), repeatability (RSD = 5.2%), medium-term stability (1.9% deviation over 90 min), acceptable reproducibility (6.6%), and mechanical reliability during skin insertion. Notably, to the best of our knowledge, this study represents the first comprehensive evaluation of the performance of an oxygen microneedle sensor, including systematic in vitro, on-body, and in vivo experiments. The sensor\u2019s accuracy was validated with a Pearson correlation coefficient of 0.99 for in vitro tests, and on-body oxygen measurements in euthanized rats highlighted the reliability of the O2 MN patch for dermal ISF oxygen detection. In vivo studies further revealed a strong positive correlation (Pearson correlation coefficient = 0.83) between dermal ISF and blood oxygen levels, underscoring the O2 MN patch\u2019s potential for biomedical applications through real-time, minimally invasive monitoring.<\/jats:p>","DOI":"10.1021\/acssensors.5c04533","type":"journal-article","created":{"date-parts":[[2026,3,16]],"date-time":"2026-03-16T10:10:45Z","timestamp":1773655845000},"page":"5525-5534","source":"Crossref","is-referenced-by-count":1,"title":["Oxygen Detection in Dermal Interstitial Fluid with Microneedles Based on Platinum Nanoparticles"],"prefix":"10.1021","volume":"11","author":[{"given":"Qikun","family":"Wei","sequence":"first","affiliation":[{"name":"KTH Royal Institute of Technology , , Teknikringen 30 , ,","place":["Stockholm, Sweden, SE-114 28"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qianyu","family":"Wang","sequence":"additional","affiliation":[{"name":"KTH Royal Institute of Technology , , Teknikringen 30 , ,","place":["Stockholm, Sweden, SE-114 28"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c1gueda","family":"Molinero-Fern\u00e1ndez","sequence":"additional","affiliation":[{"name":"UCAM-SENS, Universidad Cat\u00f3lica San Antonio de Murcia, UCAM HiTech , Avda. Andres Hernandez Ros 1 , ,","place":["Murcia, Spain, 30107"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4404-4668","authenticated-orcid":true,"given":"Daniel","family":"Rojas","sequence":"additional","affiliation":[{"name":"UCAM-SENS, Universidad Cat\u00f3lica San Antonio de Murcia, UCAM HiTech , Avda. Andres Hernandez Ros 1 , ,","place":["Murcia, Spain, 30107"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rub\u00e9n","family":"Zapata-P\u00e9rez","sequence":"additional","affiliation":[{"name":"Universidad Cat\u00f3lica San Antonio de Murcia, UCAM HiTech , , Avda. Andres Hernandez Ros 1 , ,","place":["Murcia, Spain, 30107"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c5sa","family":"Konradsson-Geuken","sequence":"additional","affiliation":[{"name":"Uppsala University , , ,","place":["Uppsala, Sweden, SE-751 05"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1221-3906","authenticated-orcid":true,"given":"Gast\u00f3n A.","family":"Crespo","sequence":"additional","affiliation":[{"name":"KTH Royal Institute of Technology , , Teknikringen 30 , ,","place":["Stockholm, Sweden, SE-114 28"]},{"name":"UCAM-SENS, Universidad Cat\u00f3lica San Antonio de Murcia, UCAM HiTech , Avda. Andres Hernandez Ros 1 , ,","place":["Murcia, Spain, 30107"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3858-8466","authenticated-orcid":true,"given":"Mar\u00eda","family":"Cuartero","sequence":"additional","affiliation":[{"name":"KTH Royal Institute of Technology , , Teknikringen 30 , ,","place":["Stockholm, Sweden, SE-114 28"]},{"name":"UCAM-SENS, Universidad Cat\u00f3lica San Antonio de Murcia, UCAM HiTech , Avda. Andres Hernandez Ros 1 , ,","place":["Murcia, Spain, 30107"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,3,16]]},"reference":[{"issue":"1","key":"2026081216072645300_cit1","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1590\/S1980-57642010DN40100003","article-title":"Cognition and Chronic Hypoxia in Pulmonary Diseases","volume":"4","author":"Areza-Fegyveres","year":"2010","journal-title":"Dement. Neuropsychol."},{"issue":"1","key":"2026081216072645300_cit2","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1021\/acssensors.2c01907","article-title":"In Vivo Transdermal Multi-Ion Monitoring with a Potentiometric Microneedle-Based Sensor Patch","volume":"8","author":"Molinero-Fern\u00e1ndez","year":"2022","journal-title":"ACS Sens."},{"issue":"8","key":"2026081216072645300_cit3","doi-asserted-by":"publisher","first-page":"785","DOI":"10.3390\/diagnostics14080785","article-title":"Recent Technologies for Transcutaneous Oxygen and Carbon Dioxide Monitoring","volume":"14","author":"Bernasconi","year":"2024","journal-title":"Diagnostics"},{"issue":"6","key":"2026081216072645300_cit4","doi-asserted-by":"publisher","first-page":"3418","DOI":"10.1021\/acs.analchem.4c05606","article-title":"Tailoring the Electrocatalytic Properties of Porphyrin Covalent Organic Frameworks for Highly Selective Oxygen Sensing In Vivo","volume":"97","author":"Lai","year":"2025","journal-title":"Anal. Chem."},{"issue":"7","key":"2026081216072645300_cit5","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.abe0579","article-title":"Wireless, Implantable Catheter-Type Oximeter Designed for Cardiac Oxygen Saturation","volume":"7","author":"Lu","year":"2021","journal-title":"Sci. Adv."},{"issue":"10","key":"2026081216072645300_cit6","doi-asserted-by":"publisher","first-page":"1293","DOI":"10.4187\/respcare.07044","article-title":"Oxygen Use in Critical Illness","volume":"64","author":"O\u2019Driscoll","year":"2019","journal-title":"Respir. Care"},{"issue":"571","key":"2026081216072645300_cit7","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.aaw0285","article-title":"Sampling Interstitial Fluid from Human Skin Using a Microneedle Patch","volume":"12","author":"Samant","year":"2020","journal-title":"Sci. Transl. Med."},{"issue":"12","key":"2026081216072645300_cit8","doi-asserted-by":"publisher","first-page":"1541","DOI":"10.1038\/s41551-022-00998-9","article-title":"Opportunities and Challenges in the Diagnostic Utility of Dermal Interstitial Fluid","volume":"7","author":"Friedel","year":"2023","journal-title":"Nat. Biomed. Eng."},{"issue":"11","key":"2026081216072645300_cit9","doi-asserted-by":"publisher","first-page":"3440","DOI":"10.1021\/acssensors.2c01775","article-title":"Phosphorescent Microneedle Array for the Measurement of Oxygen Partial Pressure in Tissue","volume":"7","author":"M\u00fcller","year":"2022","journal-title":"ACS Sens."},{"key":"2026081216072645300_cit10","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.202502540","article-title":"Pain-Free and Wireless Luminescent Microneedle Sensor Array for In Situ Monitoring Tissue Oxygenation Status in Diabetic Foot Ulcers","author":"Jiang","year":"2026","journal-title":"Adv. Healthc. Mater."},{"issue":"1","key":"2026081216072645300_cit11","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1021\/acs.analchem.4c04345","article-title":"Microneedle-Based Electrochemical Array Patch for Ultra-Antifouling and Ultra-Anti-Interference Monitoring of Subcutaneous Oxygen","volume":"97","author":"Liu","year":"2025","journal-title":"Anal. Chem."},{"issue":"8","key":"2026081216072645300_cit12","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1002\/bies.201500002","article-title":"Luminescent sensing and imaging of oxygen: Fierce competition to the Clark electrode","volume":"37","author":"Wolfbeis","year":"2015","journal-title":"Bioessays"},{"issue":"2","key":"2026081216072645300_cit13","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.jelechem.2004.08.013","article-title":"Temperature-Dependence of Oxygen Reduction Activity at a Platinum Electrode in an Acidic Electrolyte Solution Investigated with a Channel Flow Double Electrode","volume":"574","author":"Wakabayashi","year":"2005","journal-title":"J. Electroanal. Chem."},{"key":"2026081216072645300_cit14","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1016\/j.electacta.2017.04.162","article-title":"Effect of pH and Water Structure on the Oxygen Reduction Reaction on platinum electrodes","volume":"241","author":"Briega-Martos","year":"2017","journal-title":"Electrochim. Acta"},{"issue":"1","key":"2026081216072645300_cit15","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/0022-0728(93)80514-I","article-title":"A study of cathodic oxygen reduction at platinum using microelectrodes","volume":"356","author":"Pletcher","year":"1993","journal-title":"J. Electroanal. Chem."},{"issue":"5","key":"2026081216072645300_cit16","doi-asserted-by":"publisher","DOI":"10.1002\/anie.202112679","article-title":"Unexpectedly High Capacitance of the Metal Nanoparticle\/Water Interface: Molecular-Level Insights into the Electrical Double Layer","volume":"61","author":"Azimzadeh Sani","year":"2022","journal-title":"Angew. Chem., Int. Ed."},{"issue":"2","key":"2026081216072645300_cit17","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/0003-2670(93)85124-3","article-title":"Solubility of Oxygen in Glucose Solutions","volume":"280","author":"van Stroe-Biezen","year":"1993","journal-title":"Anal. Chim. Acta."},{"key":"2026081216072645300_cit18","doi-asserted-by":"publisher","DOI":"10.1016\/j.trac.2020.116148","article-title":"Microneedle Based Electrochemical (Bio)Sensing: Towards Decentralized and Continuous Health Status Monitoring","volume":"135","author":"Garc\u00eda-Guzm\u00e1n","year":"2021","journal-title":"TrAC Trends Anal. Chem."},{"issue":"9","key":"2026081216072645300_cit19","doi-asserted-by":"publisher","first-page":"3714","DOI":"10.1021\/nl2017459","article-title":"Electrocatalysis on Platinum Nanoparticles: Particle Size Effect on Oxygen Reduction Reaction Activity","volume":"11","author":"Shao","year":"2011","journal-title":"Nano Lett."},{"issue":"6","key":"2026081216072645300_cit20","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1111\/j.1582-4934.2011.01258.x","article-title":"Why Is the Partial Oxygen Pressure of Human Tissues a Crucial Parameter? Small Molecules and Hypoxia","volume":"15","author":"Carreau","year":"2011","journal-title":"J. Cell Mol. Med."},{"issue":"5","key":"2026081216072645300_cit21","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1295\/polymj.PJ2008266","article-title":"Temperature Dependence on Gas Permeability and Permselectivity of Poly(Lactic Acid) Blend Membranes","volume":"41","author":"Komatsuka","year":"2009","journal-title":"Polym. J."},{"issue":"4","key":"2026081216072645300_cit22","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/0039-9140(93)80002-9","article-title":"Amperometric Gas Sensors","volume":"40","author":"Chang","year":"1993","journal-title":"Talanta"},{"issue":"2","key":"2026081216072645300_cit23","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.jneumeth.2010.11.013","article-title":"Characterisation of Carbon Paste Electrodes for Real-Time Amperometric Monitoring of Brain Tissue Oxygen","volume":"195","author":"Bolger","year":"2011","journal-title":"J. Neurosci. Methods"},{"key":"2026081216072645300_cit24","doi-asserted-by":"publisher","DOI":"10.1021\/acssensors.5c04039","article-title":"Implementation of Sterilization and Disinfection Protocols for Potentiometric Microneedle Sensors. A Requirement for a Safety Assertion","author":"Hui","year":"2026","journal-title":"ACS Sens."},{"issue":"14","key":"2026081216072645300_cit25","doi-asserted-by":"publisher","DOI":"10.1002\/smll.202206301","article-title":"Conductive Polymer-Coated 3D Printed Microneedles: Biocompatible Platforms for Minimally Invasive Biosensing Interfaces","volume":"19","author":"Keirouz","year":"2023","journal-title":"Small"},{"issue":"9","key":"2026081216072645300_cit26","doi-asserted-by":"publisher","first-page":"2524","DOI":"10.1021\/acssensors.9b01322","article-title":"Cytotoxicity Study of Ionophore-Based Membranes: Toward On-Body and in Vivo Ion Sensing","volume":"4","author":"C\u00e1novas","year":"2019","journal-title":"ACS Sens."},{"issue":"6","key":"2026081216072645300_cit27","first-page":"579","article-title":"A Comparison of Euthanasia Methods in Rats, Using Carbon Dioxide in Prefilled and Fixed Flow Rate Filled Chambers","volume":"43","author":"Hewett","year":"1993","journal-title":"Lab. Anim. Sci."},{"issue":"4","key":"2026081216072645300_cit28","doi-asserted-by":"publisher","DOI":"10.1088\/2050-6120\/1\/4\/045002","article-title":"Ratiometric Luminescence 2D in Vivo Imaging and Monitoring of Mouse Skin Oxygenation","volume":"1","author":"Hofmann","year":"2013","journal-title":"Methods Appl. Fluoresc."},{"issue":"7","key":"2026081216072645300_cit29","doi-asserted-by":"publisher","first-page":"1837","DOI":"10.1088\/0031-9155\/43\/7\/003","article-title":"In Vivo Measurement of Arterial and Venous Oxygenation in the Rat Using 3D Spectral-Spatial Electron Paramagnetic Resonance Imaging","volume":"43","author":"Kuppusamy","year":"1998","journal-title":"Phys. Med. Biol."},{"issue":"1","key":"2026081216072645300_cit30","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1016\/0034-5687(82)90049-4","article-title":"Arterial Blood Gases and Acid-Base Status in Awake Rats","volume":"48","author":"Brun-Pascaud","year":"1982","journal-title":"Respir. Physiol."},{"issue":"3","key":"2026081216072645300_cit31","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/0034-5687(74)90025-5","article-title":"A theoretical analysis of the relationship between venous blood and mean tissue oxygen pressures","volume":"20","author":"Tenney","year":"1974","journal-title":"Respir. Physiol."},{"issue":"6","key":"2026081216072645300_cit32","doi-asserted-by":"publisher","first-page":"1722","DOI":"10.1002\/mrm.22968","article-title":"Quantitative Tissue Oxygen Measurement in Multiple Organs Using 19F MRI in a Rat Model","volume":"66","author":"Liu","year":"2011","journal-title":"Magn. Reson. Med."},{"issue":"6","key":"2026081216072645300_cit33","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.1152\/japplphysiol.00394.2006","article-title":"Oxygen Pressures in the Interstitial Space and Their Relationship to Those in the Blood Plasma in Resting Skeletal Muscle","volume":"101","author":"Wilson","year":"2006","journal-title":"J. Appl. Physiol."}],"container-title":["ACS Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acssensors.5c04533","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/ascefj\/article-pdf\/11\/7\/5525\/64868739\/se-2025-045339.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/ascefj\/article-pdf\/11\/7\/5525\/64868739\/se-2025-045339.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T20:26:28Z","timestamp":1786566388000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/ascefj\/article\/11\/7\/5525\/5142980\/Oxygen-Detection-in-Dermal-Interstitial-Fluid-with"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,16]]},"references-count":33,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,3,16]]},"published-print":{"date-parts":[[2026,7,24]]}},"URL":"https:\/\/doi.org\/10.1021\/acssensors.5c04533","relation":{},"ISSN":["2379-3694"],"issn-type":[{"value":"2379-3694","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,16]]}}}