{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T08:59:03Z","timestamp":1790758743559,"version":"4.1.0"},"reference-count":161,"publisher":"American Chemical Society (ACS)","issue":"9","license":[{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-029"},{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-037"},{"start":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T00:00:00Z","timestamp":1788912000000},"content-version":"stm-asf","delay-in-days":0,"URL":"https:\/\/doi.org\/10.15223\/policy-045"}],"funder":[{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["2025YFA1212700"],"award-info":[{"award-number":["2025YFA1212700"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012166","name":"National Key Research and Development Program of China","doi-asserted-by":"publisher","award":["2025YFA1212701"],"award-info":[{"award-number":["2025YFA1212701"]}],"id":[{"id":"10.13039\/501100012166","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,9,25]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Intraocular pressure (IOP) is amenable to direct regulation and a critical indicator for numerous ocular disorders. Continuous, long-term IOP monitoring provides indispensable clinical data, supporting early diagnosis, risk stratification, and personalized treatment. This review comprehensively summarizes the working principles, key performance metrics, and clinical progress of wearable and implantable IOP sensors. The text elucidates the structural integration of wireless power supplies, signal transmission, and artificial intelligence within wireless IOP monitoring systems. Furthermore, manufacturing and optimization strategies are highlighted, and the considerable advantages of nanomaterials and micro\/nanostructures are comprehensively summarized, emphasizing their crucial role in current IOP monitoring devices. Additionally, the diverse applications of IOP sensors in disease diagnosis and therapeutic management are discussed, underscoring their potential for personalized and precision medicine, alongside the challenges remaining in their clinical translation. Finally, current bottlenecks and limitations are addressed, outlining potential solutions, future trends, and potential breakthroughs in next-generation IOP monitoring.<\/jats:p>","DOI":"10.1021\/acssensors.6c02609","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T20:02:11Z","timestamp":1788984131000},"page":"7870-7897","source":"Crossref","is-referenced-by-count":0,"title":["Review on Intraocular Pressure-Sensing Systems from Fabrication to Applications"],"prefix":"10.1021","volume":"11","author":[{"given":"Yun","family":"Zheng","sequence":"first","affiliation":[{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"RuiYang","family":"Wang","sequence":"additional","affiliation":[{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JunXuan","family":"Li","sequence":"additional","affiliation":[{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Zhou","sequence":"additional","affiliation":[{"name":"Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences , ,","place":["Shanghai, China, 200050"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9907-0188","authenticated-orcid":true,"given":"Tie","family":"Li","sequence":"additional","affiliation":[{"name":"Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences , ,","place":["Shanghai, China, 200050"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1443-2667","authenticated-orcid":true,"given":"Yong","family":"Tao","sequence":"additional","affiliation":[{"name":"Capital Medical University , , ,","place":["Beijing, P.R. China, 100020"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8239-2703","authenticated-orcid":true,"given":"Zhishan","family":"Yuan","sequence":"additional","affiliation":[{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]},{"name":"Guangdong University of Technology , , ,","place":["Guangzhou, China, 510006"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,9,9]]},"reference":[{"issue":"24","key":"2026092919102162300_cit1","doi-asserted-by":"publisher","DOI":"10.1002\/adma.202108389","article-title":"Lab-on-a-Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics","volume":"34","author":"Zhu","year":"2022","journal-title":"Adv. Mater."},{"key":"2026092919102162300_cit2","doi-asserted-by":"crossref","DOI":"10.1007\/s44174-025-00616-7","article-title":"Smart Contact Lenses for Non-invasive Medical Diagnostics: Materials, Mechanisms, and Future Clinical Integration","author":"Patel","year":"2025","journal-title":"Biomed. Mater. Devices"},{"issue":"4","key":"2026092919102162300_cit3","doi-asserted-by":"publisher","DOI":"10.1002\/smll.202506036","article-title":"Advances in Intraocular Pressure Biosensors: Sensing Mechanisms, System Integration, and Clinical Translation Challenges","volume":"22","author":"Yang","year":"2025","journal-title":"Small"},{"key":"2026092919102162300_cit4","doi-asserted-by":"publisher","first-page":"52","DOI":"10.2174\/1874364101004010052","article-title":"Aqueous Humor Dynamics: A Review","volume":"4","author":"Goel","year":"2010","journal-title":"Open Ophthalmol. J."},{"issue":"17","key":"2026092919102162300_cit5","doi-asserted-by":"publisher","first-page":"3860","DOI":"10.3390\/jcm10173860","article-title":"How to Measure Intraocular Pressure: An Updated Review of Various Tonometers","volume":"10","author":"Brusini","year":"2021","journal-title":"J. Clin. Med."},{"issue":"18","key":"2026092919102162300_cit6","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1001\/jama.2014.3192","article-title":"The Pathophysiology and Treatment of Glaucoma: A Review","volume":"311","author":"Weinreb","year":"2014","journal-title":"JAMA"},{"issue":"10414","key":"2026092919102162300_cit7","doi-asserted-by":"publisher","first-page":"1788","DOI":"10.1016\/S0140-6736(23)01289-8","article-title":"Glaucoma: Now and Beyond","volume":"402","author":"Jayaram","year":"2023","journal-title":"Lancet"},{"issue":"1","key":"2026092919102162300_cit8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.jaapos.2016.09.026","article-title":"Steroid-Induced Glaucoma in the Pediatric Population","volume":"21","author":"Nuyen","year":"2017","journal-title":"J. AAPOS"},{"issue":"4","key":"2026092919102162300_cit9","doi-asserted-by":"publisher","first-page":"235","DOI":"10.3109\/08820539409060021","article-title":"Increased Intraocular Pressure After Cataract Surgery","volume":"9","author":"Fang","year":"1994","journal-title":"Semin. Ophthalmol."},{"issue":"3","key":"2026092919102162300_cit10","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.ophtha.2025.10.008","article-title":"Intraocular Pressure after Phacoemulsification with Retained Lens Fragments in the IRIS\u00ae Registry (Intelligent Research in Sight)","volume":"133","author":"Rothman","year":"2026","journal-title":"Ophthalmology"},{"issue":"1","key":"2026092919102162300_cit11","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1007\/s00417-025-06978-4","article-title":"Smart Contact Lenses: Recent Advances and Future Challenges in Eye Disease Diagnosis and Treatment","volume":"264","author":"Li","year":"2026","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"issue":"2","key":"2026092919102162300_cit12","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1007\/s10544-025-00740-7","article-title":"Enhancing Glaucoma Care with Smart Contact Lenses: An Overview of Recent Developments","volume":"27","author":"Fardoost","year":"2025","journal-title":"Biomed. Microdevices"},{"key":"2026092919102162300_cit13","volume-title":"The History of Ophthalmology","author":"Albert","year":"1996"},{"issue":"1","key":"2026092919102162300_cit14","doi-asserted-by":"publisher","first-page":"E16","DOI":"10.1097\/opx.0b013e318205a4e7","article-title":"A History of Intraocular Pressure and Its Measurement","volume":"88","author":"Stamper","year":"2011","journal-title":"Optom. Vis. Sci."},{"issue":"6","key":"2026092919102162300_cit15","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.ogla.2020.04.015","article-title":"The Pressure: Before and after Schi\u00f8tz","volume":"3","author":"Albert","year":"2020","journal-title":"Ophthalmol. Glaucoma"},{"issue":"11","key":"2026092919102162300_cit16","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1001\/archopht.123.11.1532","article-title":"Clinical Comparison of Contour and Applanation Tonometry and Their Relationship to Pachymetry","volume":"123","author":"Kniestedt","year":"2005","journal-title":"Arch. Ophthalmol."},{"key":"2026092919102162300_cit17","first-page":"72700O","volume-title":"Development of a Wireless Intra-Ocular Pressure Monitoring System for Incorporation into a Therapeutic Glaucoma Drainage Implant In Biomedical Applications of Micro- and Nanoengineering IV and Complex Systems","author":"Kakaday","year":"2008"},{"issue":"10","key":"2026092919102162300_cit18","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1007\/s00347-010-2198-4","article-title":"Continuous 24 h Monitoring of Changes in Intraocular Pressure with the Wireless Contact Lens Sensor Triggerfish\u2122. First Results in Patients","volume":"107","author":"Faschinger","year":"2010","journal-title":"Ophthalmologe"},{"key":"2026092919102162300_cit19","doi-asserted-by":"publisher","first-page":"875","DOI":"10.2147\/OPTH.S109708","article-title":"The Sensimed Triggerfish Contact Lens Sensor: Efficacy, Safety, and Patient Perspectives","volume":"11","author":"Dunbar","year":"2017","journal-title":"Clin. Ophthalmol."},{"key":"2026092919102162300_cit20","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2024.101303","article-title":"The Relationship between Intraocular Pressure and Glaucoma: An Evolving Concept","volume":"103","author":"Asrani","year":"2024","journal-title":"Prog. Retin. Eye Res."},{"issue":"5","key":"2026092919102162300_cit21","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1016\/j.survophthal.2022.03.001","article-title":"Intraocular Pressure Measurement: A Review","volume":"67","author":"Da Silva","year":"2022","journal-title":"Surv. Ophthalmol."},{"key":"2026092919102162300_cit22","doi-asserted-by":"publisher","DOI":"10.1016\/j.cej.2024.154823","article-title":"Smart Contact Lenses: From Rational Design Strategies to Wearable Health Monitoring","volume":"497","author":"Han","year":"2024","journal-title":"Chem. Eng. J."},{"key":"2026092919102162300_cit23","doi-asserted-by":"publisher","DOI":"10.1002\/admt.202501191","article-title":"Recent Advances in Wearable and Implantable Intraocular Pressure Sensors for Glaucoma Prevention and Therapeutic Management","volume":"10","author":"Tai","year":"2025","journal-title":"Adv. Mater. Technol."},{"issue":"6","key":"2026092919102162300_cit24","doi-asserted-by":"publisher","DOI":"10.1002\/advs.202002971","article-title":"Wearable and Implantable Intraocular Pressure Biosensors: Recent Progress and Future Prospects","volume":"8","author":"Yang","year":"2021","journal-title":"Adv. Sci."},{"issue":"5","key":"2026092919102162300_cit25","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1016\/j.survophthal.2019.02.011","article-title":"Intraocular Pressure Measurement after Corneal Transplantation","volume":"64","author":"Padua Soares Bezerra","year":"2019","journal-title":"Surv. Ophthalmol."},{"issue":"2","key":"2026092919102162300_cit26","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.202302460","article-title":"Implantable Flexible Sensors for Health Monitoring","volume":"13","author":"Yu","year":"2024","journal-title":"Adv. Healthc. Mater."},{"issue":"40","key":"2026092919102162300_cit27","doi-asserted-by":"publisher","first-page":"55781","DOI":"10.1021\/acsami.5c14400","article-title":"Nanocomposite-Based Smart Ocular Sensors: Opportunities, Challenges, and Future Directions","volume":"17","author":"Ji","year":"2025","journal-title":"ACS Appl. Mater. Interfaces"},{"key":"2026092919102162300_cit28","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1109\/ICHST59286.2023.10565324","article-title":"Ocular Pressure Sensing for Smart Health: Recent Developments, Challenges, and Future Directions","volume-title":"2023 1st International Conference on Health Science and Technology (ICHST)","author":"Gabby","year":"2023"},{"key":"2026092919102162300_cit29","doi-asserted-by":"publisher","DOI":"10.2174\/0118743641430437251130165439","article-title":"Recent Advances and Future Directions of Artificial Intelligence in Glaucoma Management","volume":"20","author":"Tang","year":"2026","journal-title":"Open Ophthalmol. J."},{"issue":"19","key":"2026092919102162300_cit30","doi-asserted-by":"publisher","first-page":"11488","DOI":"10.1021\/acs.chemrev.3c00290","article-title":"Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management","volume":"123","author":"Seo","year":"2023","journal-title":"Chem. Rev."},{"issue":"9","key":"2026092919102162300_cit31","doi-asserted-by":"publisher","first-page":"6817","DOI":"10.1021\/acsnano.3c12072","article-title":"Smart Contact Lenses for Healthcare Monitoring and Therapy","volume":"18","author":"Liu","year":"2024","journal-title":"ACS Nano"},{"issue":"7","key":"2026092919102162300_cit32","doi-asserted-by":"publisher","first-page":"856","DOI":"10.3390\/mi15070856","article-title":"Smart Contact Lenses in Ophthalmology: Innovations, Applications, and Future Prospects","volume":"15","author":"Wu","year":"2024","journal-title":"Micromachines"},{"key":"2026092919102162300_cit33","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1016\/j.jconrel.2025.01.082","article-title":"Smart Theranostic Contact Lenses","volume":"379","author":"Kim","year":"2025","journal-title":"J. Control. Release"},{"issue":"12","key":"2026092919102162300_cit34","doi-asserted-by":"publisher","first-page":"1507","DOI":"10.1001\/jamaophthalmol.2013.5297","article-title":"24-Hour Intraocular Pressure Rhythm in Young Healthy Subjects Evaluated With Continuous Monitoring Using a Contact Lens Sensor","volume":"131","author":"Mottet","year":"2013","journal-title":"JAMA Ophthalmol."},{"issue":"5","key":"2026092919102162300_cit35","doi-asserted-by":"publisher","first-page":"866","DOI":"10.1111\/vop.70071","article-title":"Validation of the EYEMATE-SC Suprachoroidal Pressure Transducer for Telemetric Measurement of Intraocular Pressure in Normal Ex Vivo Canine and Equine Globes\u2014Preliminary Results","volume":"28","author":"Buckman","year":"2025","journal-title":"Vet. Ophthalmol."},{"issue":"1","key":"2026092919102162300_cit36","doi-asserted-by":"publisher","DOI":"10.1155\/2019\/3632197","article-title":"Role of 24-Hour Intraocular Pressure Monitoring in Glaucoma Management","volume":"2019","author":"Ho","year":"2019","journal-title":"J. Ophthalmol."},{"issue":"19","key":"2026092919102162300_cit37","doi-asserted-by":"publisher","first-page":"18586","DOI":"10.1021\/acsnano.5c02762","article-title":"Reproducible Transpalpebral Intraocular Pressure Sensing Enabled by Low-Energy-Barrier Ion Pumping","volume":"19","author":"Ren","year":"2025","journal-title":"ACS Nano"},{"key":"2026092919102162300_cit38","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1109\/ISAEECE66033.2025.11159916","article-title":"Non-Invasive Intraocular Pressure Monitoring System Based on Amplitude and Phase Detection Technology","volume-title":"2025 10th International Symposium on Advances in Electrical, Electronics and Computer Engineering (ISAEECE)","author":"Zhang","year":"2025"},{"issue":"24","key":"2026092919102162300_cit39","doi-asserted-by":"publisher","DOI":"10.1002\/smll.202309785","article-title":"An Ultrasensitive Ti3C2Tx MXene-based Soft Contact Lens for Continuous and Nondestructive Intraocular Pressure Monitoring","volume":"20","author":"Duan","year":"2024","journal-title":"Small"},{"issue":"2","key":"2026092919102162300_cit40","doi-asserted-by":"publisher","first-page":"108","DOI":"10.3390\/mi12020108","article-title":"Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure","volume":"12","author":"Dou","year":"2021","journal-title":"Micromachines"},{"issue":"1","key":"2026092919102162300_cit41","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1038\/s41528-025-00507-3","article-title":"Ultra-Sensitive Real-Time Monitoring of Intraocular Pressure with an Integrated Smart Contact Lens Using Parity-Time Symmetry Wireless Technology","volume":"10","author":"Xiao","year":"2026","journal-title":"NPJ Flex. Electron."},{"key":"2026092919102162300_cit42","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2022.113708","article-title":"A Portable Applanation Tonometer for Accurate Intraocular Pressure Measurements","volume":"344","author":"Feng","year":"2022","journal-title":"Sens. Actuators A Phys."},{"issue":"1","key":"2026092919102162300_cit43","doi-asserted-by":"publisher","DOI":"10.1088\/0960-1317\/26\/1\/015001","article-title":"A Capacitor-Based Sensor and a Contact Lens Sensing System for Intraocular Pressure Monitoring","volume":"26","author":"Chiou","year":"2016","journal-title":"J. Micromech. Microeng."},{"issue":"17","key":"2026092919102162300_cit44","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.202520580","article-title":"Flexible Transparent Capacitive Pressure Sensors for Multimodal Ophthalmic Monitoring: Intraocular Pressure Assessment, Movement Disorder Diagnosis, and Eye-Tracking Human\u2013Computer Interaction System","volume":"36","author":"Li","year":"2026","journal-title":"Adv. Funct. Mater."},{"issue":"34","key":"2026092919102162300_cit45","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.202400722","article-title":"Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability","volume":"34","author":"Yang","year":"2024","journal-title":"Adv. Funct. Mater."},{"key":"2026092919102162300_cit46","doi-asserted-by":"publisher","first-page":"95235","DOI":"10.1109\/access.2023.3309300","article-title":"Measurement Techniques and Challenges of Wireless LC Resonant Sensors: A Review","volume":"11","author":"Masud","year":"2023","journal-title":"IEEE Access"},{"issue":"3","key":"2026092919102162300_cit47","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6439\/abd8e0","article-title":"High-Sensitivity Liquid-Metal-Based Contact Lens Sensor for Continuous Intraocular Pressure Monitoring","volume":"31","author":"An","year":"2021","journal-title":"J. Micromech. Microeng."},{"issue":"1","key":"2026092919102162300_cit48","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1038\/s41528-024-00341-z","article-title":"LC Contact Lens Sensor for Ultrasensitive Intraocular Pressure Monitoring","volume":"8","author":"An","year":"2024","journal-title":"NPJ Flex. Electron."},{"issue":"1","key":"2026092919102162300_cit49","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6501\/ad89eb","article-title":"LC Dynamic Signal Modeling and Analysis of Resonant Frequency Measurement Error under Rapid Eye Movements Interference","volume":"36","author":"An","year":"2025","journal-title":"Meas. Sci. Technol."},{"issue":"17","key":"2026092919102162300_cit50","doi-asserted-by":"publisher","first-page":"22522","DOI":"10.1021\/acsami.4c02289","article-title":"Temperature Self-Compensating Intelligent Wireless Measuring Contact Lens for Quantitative Intraocular Pressure Monitoring","volume":"16","author":"Li","year":"2024","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"1","key":"2026092919102162300_cit51","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1038\/s41378-025-00946-y","article-title":"Closed-Eye Intraocular Pressure and Eye Movement Monitoring via a Stretchable Bimodal Contact Lens","volume":"11","author":"Gan","year":"2025","journal-title":"Microsyst. Nanoeng."},{"key":"2026092919102162300_cit52","doi-asserted-by":"publisher","DOI":"10.1016\/j.cej.2024.155357","article-title":"Magneto-Elastic for Wireless Intraocular Pressure Monitoring","volume":"498","author":"Lin","year":"2024","journal-title":"Chem. Eng. J."},{"issue":"1","key":"2026092919102162300_cit53","doi-asserted-by":"publisher","first-page":"2556","DOI":"10.1038\/s41467-022-29860-x","article-title":"Intelligent Wireless Theranostic Contact Lens for Electrical Sensing and Regulation of Intraocular Pressure","volume":"13","author":"Yang","year":"2022","journal-title":"Nat. Commun."},{"issue":"10","key":"2026092919102162300_cit54","doi-asserted-by":"publisher","first-page":"1740","DOI":"10.1039\/c9lc01268k","article-title":"Photonic Crystal-Based Smart Contact Lens for Continuous Intraocular Pressure Monitoring","volume":"20","author":"Maeng","year":"2020","journal-title":"Lab Chip"},{"issue":"16","key":"2026092919102162300_cit55","doi-asserted-by":"publisher","first-page":"3519","DOI":"10.1039\/c9tb02389e","article-title":"Structurally Coloured Contact Lens Sensor for Point-of-Care Ophthalmic Health Monitoring","volume":"8","author":"Wang","year":"2020","journal-title":"J. Mater. Chem. B"},{"key":"2026092919102162300_cit56","doi-asserted-by":"publisher","DOI":"10.1016\/j.yofte.2024.103777","article-title":"Non-Invasive FBG-Based Contact Lens for Continuous Intraocular Pressure Monitoring","volume":"84","author":"Kumuda","year":"2024","journal-title":"Opt. Fiber Technol."},{"issue":"6","key":"2026092919102162300_cit57","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1109\/jmems.2022.3206712","article-title":"Soft Contact Lens With Embedded Moir\u00e9 Patterns-Based Intraocular Pressure Sensors","volume":"31","author":"Ding","year":"2022","journal-title":"J. Microelectromech. Syst."},{"issue":"7","key":"2026092919102162300_cit58","doi-asserted-by":"publisher","first-page":"4996","DOI":"10.1021\/acssensors.5c00883","article-title":"Smart Contact Lens with High Sensitivity and Biocompatibility for Continuous Non-Invasive Intraocular Pressure Monitoring","volume":"10","author":"Tai","year":"2025","journal-title":"ACS Sens."},{"key":"2026092919102162300_cit59","doi-asserted-by":"publisher","first-page":"193701","DOI":"10.1063\/5.0075446","article-title":"Notched-Ring Structured Microfluidic Contact Lens for Intraocular Pressure Monitoring","volume":"119","author":"Yang","year":"2021","journal-title":"Appl. Phys. Lett."},{"issue":"22","key":"2026092919102162300_cit60","doi-asserted-by":"publisher","first-page":"3471","DOI":"10.1039\/c8lc00758f","article-title":"Ultra-Sensitive Microfluidic Wearable Strain Sensor for Intraocular Pressure Monitoring","volume":"18","author":"Agaoglu","year":"2018","journal-title":"Lab Chip"},{"issue":"22","key":"2026092919102162300_cit61","doi-asserted-by":"publisher","first-page":"3899","DOI":"10.1039\/c9lc00842j","article-title":"Flow Stabilization in Wearable Microfluidic Sensors Enables Noise Suppression","volume":"19","author":"Araci","year":"2019","journal-title":"Lab Chip"},{"key":"2026092919102162300_cit62","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.sna.2019.04.050","article-title":"Microfluidic Contact Lenses for Unpowered, Continuous and Non-Invasive Intraocular Pressure Monitoring","volume":"295","author":"An","year":"2019","journal-title":"Sens. Actuators A Phys."},{"issue":"3","key":"2026092919102162300_cit63","doi-asserted-by":"publisher","DOI":"10.1002\/mds3.10086","article-title":"A Novel Non-Invasive Wearable Sensor for Intraocular Pressure Measurement","volume":"3","author":"Campigotto","year":"2020","journal-title":"Med. Devices Sens."},{"issue":"1","key":"2026092919102162300_cit64","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1038\/s41378-025-00909-3","article-title":"Microfluidic Contact Lens: Fabrication Approaches and Applications","volume":"11","author":"Aravind","year":"2025","journal-title":"Microsyst. Nanoeng."},{"issue":"10","key":"2026092919102162300_cit65","doi-asserted-by":"publisher","first-page":"2745","DOI":"10.1109\/JSSC.2023.3286796","article-title":"An RC Delay-Based Pressure-Sensing System With Energy-Efficient Bit-Level Oversampling Techniques for Implantable IOP Monitoring Systems","volume":"58","author":"Seo","year":"2023","journal-title":"IEEE J. Solid-State Circuits"},{"issue":"8","key":"2026092919102162300_cit66","doi-asserted-by":"publisher","first-page":"3958","DOI":"10.1021\/acssensors.4c00705","article-title":"A Novel Implantable Piezoresistive Microsensor for Intraocular Pressure Measurement","volume":"9","author":"Li","year":"2024","journal-title":"ACS Sens."},{"key":"2026092919102162300_cit67","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2023.114480","article-title":"Novel Planar Sensor Using Stretchable Vapor Phased Polymerized PEDOT\/PDMS Film","volume":"359","author":"Xu","year":"2023","journal-title":"Sens. Actuators A Phys."},{"issue":"9","key":"2026092919102162300_cit68","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1038\/nm.3621","article-title":"An Implantable Microfluidic Device for Self-Monitoring of Intraocular Pressure","volume":"20","author":"Araci","year":"2014","journal-title":"Nat. Med."},{"key":"2026092919102162300_cit69","doi-asserted-by":"publisher","first-page":"353","DOI":"10.3390\/mi14020353","article-title":"High-Accuracy Film-Integrated Optical Sensor for Real-Time Intraocular Pressure Monitoring","volume":"14","author":"Xu","year":"2023","journal-title":"Micromachines"},{"key":"2026092919102162300_cit70","doi-asserted-by":"publisher","first-page":"1915","DOI":"10.3390\/mi14101915","article-title":"Advancements in Wearable and Implantable Intraocular Pressure Biosensors for Ophthalmology: A Comprehensive Review","volume":"14","author":"Wu","year":"2023","journal-title":"Micromachines"},{"issue":"1","key":"2026092919102162300_cit71","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1186\/s11671-026-04734-z","article-title":"Carbon Based Functional Materials Enable Multifunctional Flexible Strain Sensors for Wearable and Implantable Applications","volume":"21","author":"Wang","year":"2026","journal-title":"Discov. Nano"},{"issue":"4","key":"2026092919102162300_cit72","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.201601356","article-title":"Biocompatible Multifunctional Black-Silicon for Implantable Intraocular Sensor","volume":"6","author":"Lee","year":"2017","journal-title":"Adv. Healthcare Mater."},{"issue":"4","key":"2026092919102162300_cit73","doi-asserted-by":"publisher","DOI":"10.1002\/admt.202200853","article-title":"Materials and Biomedical Applications of Implantable Electronic Devices","volume":"8","author":"Liu","year":"2023","journal-title":"Adv. Mater. Technol."},{"issue":"1","key":"2026092919102162300_cit74","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1007\/s40820-023-01272-6","article-title":"Advances in Wireless, Batteryless, Implantable Electronics for Real-Time, Continuous Physiological Monitoring","volume":"16","author":"Kim","year":"2023","journal-title":"Nano-Micro Lett."},{"issue":"16","key":"2026092919102162300_cit75","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1109\/LPT.2023.3276078","article-title":"MEMS Sensor-Glasses Pair for Real-Time Monitoring of Intraocular Pressure","volume":"35","author":"Zolfaghari","year":"2023","journal-title":"IEEE Photon. Technol. Lett."},{"issue":"6","key":"2026092919102162300_cit76","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.adk7805","article-title":"Real-Time In Vivo Monitoring of Intraocular Pressure Distribution in the Anterior Chamber and Vitreous Chamber for Diagnosis of Glaucoma","volume":"10","author":"Seo","year":"2024","journal-title":"Sci. Adv."},{"key":"2026092919102162300_cit77","doi-asserted-by":"publisher","DOI":"10.1016\/j.iot.2022.100547","article-title":"An IoT-Based Interoperable Architecture for Wireless Biomonitoring of Patients with Sensor Patches","volume":"19","author":"Fam\u00e1","year":"2022","journal-title":"Internet Things"},{"issue":"2","key":"2026092919102162300_cit78","doi-asserted-by":"publisher","first-page":"1687","DOI":"10.1007\/s11277-020-07446-4","article-title":"Internet of Things (IoT), Applications and Challenges: A Comprehensive Review","volume":"114","author":"Khanna","year":"2020","journal-title":"Wireless Personal Commun."},{"issue":"5","key":"2026092919102162300_cit79","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1109\/JBHI.2016.2594058","article-title":"Toward a Wirelessly Powered On-Lens Intraocular Pressure Monitoring System","volume":"20","author":"Chiou","year":"2016","journal-title":"IEEE J. Biomed. Health Inform."},{"issue":"10","key":"2026092919102162300_cit80","doi-asserted-by":"publisher","first-page":"3014","DOI":"10.1021\/acssensors.2c01299","article-title":"Hydrogel-Based Smart Contact Lens for Highly Sensitive Wireless Intraocular Pressure Monitoring","volume":"7","author":"Zhu","year":"2022","journal-title":"ACS Sens."},{"issue":"7","key":"2026092919102162300_cit81","doi-asserted-by":"publisher","first-page":"772","DOI":"10.1038\/s41551-021-00719-8","article-title":"A Soft and Transparent Contact Lens for the Wireless Quantitative Monitoring of Intraocular Pressure","volume":"5","author":"Kim","year":"2021","journal-title":"Nat. Biomed. Eng."},{"issue":"27","key":"2026092919102162300_cit82","doi-asserted-by":"publisher","first-page":"16457","DOI":"10.1039\/D4TA02127D","article-title":"Eye-Wearable Ti3C2Tx MXene-Based Micro-Supercapacitor as a Power Unit for Intraocular Pressure Applications","volume":"12","author":"Liu","year":"2024","journal-title":"J. Mater. Chem. A"},{"issue":"5","key":"2026092919102162300_cit83","doi-asserted-by":"publisher","DOI":"10.1002\/aisy.202000263","article-title":"Smart Contact Lenses for Biosensing Applications","volume":"3","author":"Ma","year":"2021","journal-title":"Adv. Intell. Syst."},{"key":"2026092919102162300_cit84","doi-asserted-by":"publisher","DOI":"10.1016\/j.nanoen.2024.109496","article-title":"Recent Advances in Wireless Energy Transfer Technologies for Body-Interfaced Electronics","volume":"124","author":"Park","year":"2024","journal-title":"Nano Energy"},{"issue":"18","key":"2026092919102162300_cit85","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.202402148","article-title":"Kirigami-Inspired Breathable Smart Contact Lens for Wireless Monitoring of Corneal Hypoxia and Microenvironment","volume":"14","author":"Zhu","year":"2025","journal-title":"Adv. Healthc. Mater."},{"issue":"4","key":"2026092919102162300_cit86","doi-asserted-by":"publisher","first-page":"1082","DOI":"10.3390\/s24041082","article-title":"Blink-Related Oscillations Provide Naturalistic Assessments of Brain Function and Cognitive Workload within Complex Real-World Multitasking Environments","volume":"24","author":"Page","year":"2024","journal-title":"Sensors"},{"key":"2026092919102162300_cit87","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2022.112387","article-title":"A Comprehensive Compensation Method for Piezoresistive Pressure Sensor Based on Surface Fitting and Improved Grey Wolf Algorithm","volume":"207","author":"Zhao","year":"2023","journal-title":"Measurement"},{"issue":"1","key":"2026092919102162300_cit88","doi-asserted-by":"publisher","DOI":"10.1061\/JCEMD4.COENG-13263","article-title":"Evaluation of Data Processing and Artifact Removal Approaches Used for Physiological Signals Captured Using Wearable Sensing Devices during Construction Tasks","volume":"150","author":"Anwer","year":"2024","journal-title":"J. Constr. Eng. Manag."},{"issue":"3","key":"2026092919102162300_cit89","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1167\/iovs.64.3.3","article-title":"24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression","volume":"64","author":"Gaboriau","year":"2023","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"issue":"21","key":"2026092919102162300_cit90","doi-asserted-by":"publisher","first-page":"8309","DOI":"10.3390\/s22218309","article-title":"Machine Learning and Swarm Optimization Algorithm in Temperature Compensation of Pressure Sensors","volume":"22","author":"Wang","year":"2022","journal-title":"Sensors"},{"issue":"7","key":"2026092919102162300_cit91","doi-asserted-by":"publisher","DOI":"10.1002\/adsr.202500028","article-title":"Machine Learning Enhanced Multimodal Bioelectronics: Advancement Toward Intelligent Healthcare Systems","volume":"4","author":"Oh","year":"2025","journal-title":"Adv. Sensor Res."},{"key":"2026092919102162300_cit92","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2022.114825","article-title":"Wearable Artificial Intelligence Biosensor Networks","volume":"219","author":"Zhang","year":"2023","journal-title":"Biosens. Bioelectron."},{"issue":"1","key":"2026092919102162300_cit93","doi-asserted-by":"publisher","first-page":"179","DOI":"10.3390\/engproc2023059179","article-title":"Intraocular Pressure Monitoring System for Glaucoma Patients Using IoT and Machine Learning","volume":"59","author":"Chinnaswamy","year":"2023","journal-title":"Eng. Proc."},{"issue":"1","key":"2026092919102162300_cit94","doi-asserted-by":"publisher","first-page":"7940","DOI":"10.1038\/s41598-025-89893-2","article-title":"Application of Machine Learning Techniques in GlaucomAI System for Glaucoma Diagnosis and Collaborative Research Support","volume":"15","author":"\u015awierczy\u0144ski","year":"2025","journal-title":"Sci. Rep."},{"key":"2026092919102162300_cit95","first-page":"473","article-title":"Smart Contact Lenses for Integrating IoT and Cloud-Based Neural Networks for Early Detection of Ocular Diseases","volume-title":"10th International Conference on Smart Computing and Communication (ICSCC)","author":"Theoderaj","year":"2024"},{"key":"2026092919102162300_cit96","first-page":"1","article-title":"IoT & AI-ML Based Portable Non-Contact Retinal Imaging for Glaucoma and Eye Disease Monitoring at Home","volume-title":"2025 12th International Conference on Emerging Trends in Engineering & Technology-Signal and Information Processing (ICETET-SIP)","author":"Wankhede","year":"2025"},{"issue":"3","key":"2026092919102162300_cit97","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.29.3.037003","article-title":"Remote-and-Low-Cost Intraocular Pressure Monitoring by Deep Learning of Speckle Patterns","volume":"29","author":"Kalyuzhner","year":"2024","journal-title":"J. Biomed. Opt."},{"issue":"1","key":"2026092919102162300_cit98","doi-asserted-by":"publisher","first-page":"5635","DOI":"10.1038\/s41467-024-49907-5","article-title":"Neuroprosthetic-Contact-Lens-Enabled Sensorimotor System for Point-of-Care Monitoring and Feedback of Intraocular Pressure","volume":"15","author":"Liu","year":"2024","journal-title":"Nat. Commun."},{"key":"2026092919102162300_cit99","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2024.115392","article-title":"Liquid-Alloy-Based Dual Sensing Elements Contact Lens Sensor for Continuous Intraocular Pressure Monitoring","volume":"240","author":"Wang","year":"2025","journal-title":"Measurement"},{"issue":"5","key":"2026092919102162300_cit100","doi-asserted-by":"publisher","DOI":"10.1016\/j.xops.2025.100826","article-title":"A Novel Contact Lens Sensor System for Continuous Intraocular Pressure Monitoring: Evaluation of Accuracy in Human Eyes","volume":"5","author":"Wei","year":"2025","journal-title":"Ophthalmol. Sci."},{"key":"2026092919102162300_cit101","doi-asserted-by":"publisher","DOI":"10.1002\/adma.202516945","article-title":"Recent Advances in Wireless Smart Contact Lenses for Ophthalmic Health Management and Eye-Function Enhancement","volume":"38","author":"Liu","year":"2026","journal-title":"Adv. Mater."},{"key":"2026092919102162300_cit102","doi-asserted-by":"publisher","DOI":"10.1016\/j.bios.2024.116786","article-title":"Multi-Functional, Conformal Systems with Ultrathin Crystalline-Silicon-Based Bioelectronics for Characterization of Intraocular Pressure and Ocular Surface Temperature","volume":"267","author":"Shao","year":"2025","journal-title":"Biosens. Bioelectron."},{"issue":"31","key":"2026092919102162300_cit103","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.202308173","article-title":"Liquid-Metal-Based Biosensors: Fundamentals and Applications","volume":"34","author":"Jamalzadegan","year":"2024","journal-title":"Adv. Funct. Mater."},{"key":"2026092919102162300_cit104","first-page":"384","article-title":"Spiral Resonator-Based Corneal Contact Lens for Intraocular Pressure Monitoring","volume-title":"28th International Conference on Mechatronics and Machine Vision in Practice (M2VIP)","author":"Lu","year":"2022"},{"issue":"31","key":"2026092919102162300_cit105","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.202309614","article-title":"Controllable Flow and Manipulation of Liquid Metals","volume":"34","author":"He","year":"2023","journal-title":"Adv. Funct. Mater."},{"issue":"7","key":"2026092919102162300_cit106","doi-asserted-by":"publisher","first-page":"2691","DOI":"10.1021\/acssensors.3c00542","article-title":"Contact Lens Sensor with Anti-Jamming Capability and High Sensitivity for Intraocular Pressure Monitoring","volume":"8","author":"Ren","year":"2023","journal-title":"ACS Sens."},{"issue":"9","key":"2026092919102162300_cit107","doi-asserted-by":"publisher","first-page":"6656","DOI":"10.1021\/acssensors.5c01147","article-title":"Piezoresistive MOF for Intraocular Pressure Monitoring","volume":"10","author":"Zha","year":"2025","journal-title":"ACS Sens."},{"key":"2026092919102162300_cit108","doi-asserted-by":"publisher","DOI":"10.1002\/admt.202502146","article-title":"Multifunctional Graphene-Enhanced Smart Contact Lenses: A New Frontier in Ocular Diagnostics and Protection","volume":"11","author":"Hu","year":"2026","journal-title":"Adv. Mater. Technol."},{"issue":"38","key":"2026092919102162300_cit109","doi-asserted-by":"publisher","first-page":"8794","DOI":"10.1039\/d0tb01687j","article-title":"Application of Graphene Nanowalls in an Intraocular Pressure Sensor","volume":"8","author":"Liu","year":"2020","journal-title":"J. Mater. Chem. B"},{"issue":"16","key":"2026092919102162300_cit110","doi-asserted-by":"publisher","first-page":"18375","DOI":"10.1021\/acsami.0c02991","article-title":"Highly Transparent and Sensitive Graphene Sensors for Continuous and Non-Invasive Intraocular Pressure Monitoring","volume":"12","author":"Xu","year":"2020","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"29","key":"2026092919102162300_cit111","doi-asserted-by":"publisher","DOI":"10.1002\/adfm.202010991","article-title":"An Ultrasensitive Contact Lens Sensor Based on Self-Assembly Graphene for Continuous Intraocular Pressure Monitoring","volume":"31","author":"Liu","year":"2021","journal-title":"Adv. Mater."},{"issue":"18","key":"2026092919102162300_cit112","doi-asserted-by":"publisher","first-page":"1527","DOI":"10.3390\/nano14181527","article-title":"Silver Nanoparticles: A Comprehensive Review of Synthesis Methods and Chemical and Physical Properties","volume":"14","author":"Duman","year":"2024","journal-title":"Nanomaterials"},{"issue":"2","key":"2026092919102162300_cit113","doi-asserted-by":"publisher","DOI":"10.1088\/2058-8585\/adddc7","article-title":"Silver Nanowire Infused Hydrogel Contact Lenses for Non-Invasive Intraocular Pressure Monitoring","volume":"10","author":"Alaei","year":"2025","journal-title":"Flex. Print. Electron."},{"issue":"5","key":"2026092919102162300_cit114","doi-asserted-by":"publisher","first-page":"4532","DOI":"10.1021\/acsabm.1c00267","article-title":"Smart Contact Lenses with a Transparent Silver Nanowire Strain Sensor for Continuous Intraocular Pressure Monitoring","volume":"4","author":"Kim","year":"2021","journal-title":"ACS Appl. Bio Mater."},{"issue":"1","key":"2026092919102162300_cit115","doi-asserted-by":"publisher","first-page":"6801","DOI":"10.1038\/s41467-022-34597-8","article-title":"Wireless Theranostic Smart Contact Lens for Monitoring and Control of Intraocular Pressure in Glaucoma","volume":"13","author":"Kim","year":"2022","journal-title":"Nat. Commun."},{"issue":"1","key":"2026092919102162300_cit116","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1186\/s12951-022-01415-8","article-title":"Multifunctional Flexible Contact Lens for Eye Health Monitoring Using Inorganic Magnetic Oxide Nanosheets","volume":"20","author":"Xie","year":"2022","journal-title":"J. Nanobiotechnol."},{"key":"2026092919102162300_cit117","doi-asserted-by":"publisher","DOI":"10.1016\/j.mtnano.2025.100627","article-title":"A Review on Application of Nanomaterials in Flexible Pressure Sensors","volume":"30","author":"Mohamadzadegan","year":"2025","journal-title":"Mater. Today Nano"},{"issue":"2","key":"2026092919102162300_cit118","doi-asserted-by":"publisher","DOI":"10.1016\/j.xcrp.2023.101286","article-title":"Smart Contact Lens with Transparent MXene Decoration for Ocular Photothermal Therapy and Eye Protection","volume":"4","author":"Jin","year":"2023","journal-title":"Cell Rep. Phys. Sci."},{"issue":"7","key":"2026092919102162300_cit119","doi-asserted-by":"publisher","DOI":"10.1002\/smsc.202400628","article-title":"MXene-Integrated Contact Lens: A Breakthrough in Wearable Eye Protection and Healthcare","volume":"5","author":"Hu","year":"2025","journal-title":"Small Sci."},{"issue":"13","key":"2026092919102162300_cit120","doi-asserted-by":"publisher","first-page":"13128","DOI":"10.1021\/acsnano.4c18484","article-title":"Crack-Enhanced MXene-Carbon Nanotube Soft Contact Lens for Body-Induced Intracranial Pressure Application","volume":"19","author":"Wu","year":"2025","journal-title":"ACS Nano"},{"issue":"9","key":"2026092919102162300_cit121","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6528\/abca5f","article-title":"A Wearable Contact Lens Sensor for Noninvasive In-Situ Monitoring of Intraocular Pressure","volume":"32","author":"Fan","year":"2021","journal-title":"Nanotechnology"},{"issue":"1","key":"2026092919102162300_cit122","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1007\/s40820-023-01073-x","article-title":"Nanocellulose-Assisted Construction of Multifunctional MXene-Based Aerogels with Engineering Biomimetic Texture for Pressure Sensor and Compressible Electrode","volume":"15","author":"Xu","year":"2023","journal-title":"Nano-Micro Lett."},{"issue":"19","key":"2026092919102162300_cit123","doi-asserted-by":"publisher","DOI":"10.1002\/admt.202501316","article-title":"Ultra-Sensitive Wireless Capacitive Nanocomposite-Based Pressure Sensors for Health Monitoring","volume":"10","author":"Hashemi","year":"2025","journal-title":"Adv. Mater. Technol."},{"issue":"September","key":"2026092919102162300_cit124","first-page":"18","article-title":"An Update on 24-Hour Glaucoma Monitoring: Current Approaches Reveal Remaining Challenges","volume":"24","author":"Mansouri","year":"2020","journal-title":"Ophthalmol. Manage."},{"issue":"3","key":"2026092919102162300_cit125","doi-asserted-by":"publisher","first-page":"347","DOI":"10.3390\/mi17030347","article-title":"Recent Advances in MEMS Actuators for Microfluidic Applications: Emerging Designs, Multiphysics Modeling, and Performance Optimization","volume":"17","author":"Rahman","year":"2026","journal-title":"Micromachines"},{"issue":"1","key":"2026092919102162300_cit126","doi-asserted-by":"publisher","DOI":"10.1016\/j.bmi.2025.100003","article-title":"Hydrogel-Based Smart Contact Lens for Enhanced Functional Applications","volume":"1","author":"Yao","year":"2025","journal-title":"Biomed. Instrum."},{"key":"2026092919102162300_cit127","first-page":"1","article-title":"Spiral Resonator-Based Corneal Contact Lens for Intraocular Pressure Monitoring","volume-title":"28th International Conference on Mechatronics and Machine Vision in Practice (M2VIP)","author":"Lu","year":"2022"},{"key":"2026092919102162300_cit128","doi-asserted-by":"publisher","first-page":"105","DOI":"10.2217\/3dp-2022-0010","article-title":"3D-Printed Contact Lenses: Challenges Towards Translation and Commercialization","volume":"6","author":"\u00d6zdalgic","year":"2022","journal-title":"J. 3D Print. Med."},{"issue":"2","key":"2026092919102162300_cit129","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1021\/acsbiomaterials.0c01470","article-title":"3D Printed Contact Lenses","volume":"7","author":"Alam","year":"2021","journal-title":"ACS Biomater. Sci. Eng."},{"issue":"1","key":"2026092919102162300_cit130","doi-asserted-by":"publisher","first-page":"30908","DOI":"10.1038\/s41598-025-15904-x","article-title":"Ink-Based Graphene Integration into Commercial Contact Lenses","volume":"15","author":"Shebeeb","year":"2025","journal-title":"Sci. Rep."},{"issue":"20","key":"2026092919102162300_cit131","doi-asserted-by":"publisher","DOI":"10.1002\/advs.202415272","article-title":"Laser-Enabled Fabrication of Flexible Printed Electronics with Integrated Functional Devices","volume":"12","author":"Babatain","year":"2025","journal-title":"Adv. Sci."},{"key":"2026092919102162300_cit132","first-page":"1","article-title":"Laser-Induced Graphene (LIG) Smart Contact Lens (SCL) for the Wireless Monitoring of Intra-Ocular Health","volume-title":"IEEE International Conference on RFID Technology and Applications (RFID-TA)","author":"Nanni","year":"2025"},{"issue":"10","key":"2026092919102162300_cit133","doi-asserted-by":"publisher","first-page":"7231","DOI":"10.1021\/acssensors.5c01222","article-title":"Optical Contact Lenses Biosensors","volume":"10","author":"Xia","year":"2025","journal-title":"ACS Sens."},{"issue":"9","key":"2026092919102162300_cit134","doi-asserted-by":"publisher","first-page":"2751","DOI":"10.1007\/s00417-024-06400-5","article-title":"Contact Lens Fitting and Changes in the Tear Film Dynamics: Mathematical and Computational Models Review","volume":"262","author":"Ramasubramanian","year":"2024","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"key":"2026092919102162300_cit135","doi-asserted-by":"publisher","first-page":"966","DOI":"10.3390\/bioengineering11100966","article-title":"Influence of Contact Lens Parameters on Cornea: Biomechanical Analysis","volume":"11","author":"Ramasubramanian","year":"2024","journal-title":"Bioengineering"},{"issue":"1","key":"2026092919102162300_cit136","doi-asserted-by":"publisher","DOI":"10.1126\/sciadv.aap9841","article-title":"Soft, Smart Contact Lenses with Integrations of Wireless Circuits, Glucose Sensors, and Displays","volume":"4","author":"Park","year":"2018","journal-title":"Sci. Adv."},{"key":"2026092919102162300_cit137","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2023.114250","article-title":"High-Sensitive Microfluidic Contact Lens Sensor for Intraocular Pressure Visualized Monitoring","volume":"354","author":"Yuan","year":"2023","journal-title":"Sens. Actuators, A"},{"key":"2026092919102162300_cit138","doi-asserted-by":"publisher","first-page":"4085","DOI":"10.1109\/JSSC.2026.3656705","article-title":"A 433-MHz Wireless Power and Data Transfer System for Smart Contact Lens with Integrating Receiver Achieving 0.02% Modulation Index","volume":"61","author":"Roh","year":"2026","journal-title":"IEEE J. Solid-State Circuits"},{"issue":"1","key":"2026092919102162300_cit139","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1021\/acsaelm.5c02079","article-title":"Highly Efficient Wireless Power Transfer for an Organic Light-Emitting Diode on a Smart Contact Lens Using a Flexible Helically Stacked Antenna Fabricated with a Blocker-Assisted Deposition Method","volume":"8","author":"Jang","year":"2026","journal-title":"ACS Appl. Electron. Mater."},{"issue":"6","key":"2026092919102162300_cit140","doi-asserted-by":"publisher","first-page":"2046","DOI":"10.1021\/acssensors.1c00370","article-title":"Ophthalmic Sensors and Drug Delivery","volume":"6","author":"Savariraj","year":"2021","journal-title":"ACS Sens."},{"issue":"1","key":"2026092919102162300_cit141","doi-asserted-by":"publisher","first-page":"17057","DOI":"10.1038\/micronano.2017.57","article-title":"A Microscale Optical Implant for Continuous in Vivo Monitoring of Intraocular Pressure","volume":"3","author":"Lee","year":"2017","journal-title":"Microsyst. Nanoeng."},{"issue":"8","key":"2026092919102162300_cit142","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1038\/s41433-022-02218-9","article-title":"Detection Ability of Corneal Biomechanical Parameters for Early Diagnosis of Ectasia","volume":"37","author":"Sedaghat","year":"2023","journal-title":"Eye"},{"issue":"2","key":"2026092919102162300_cit143","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1021\/acssensors.4c02361","article-title":"Kirigami-Design Smart Contact Lens for Highly Sensitive Eyelid Pressure Measurement","volume":"10","author":"Chen","year":"2025","journal-title":"ACS Sens."},{"key":"2026092919102162300_cit144","doi-asserted-by":"publisher","DOI":"10.1177\/25158414241287431","article-title":"Early Diagnostics and Interventional Glaucoma","volume":"16","author":"Francesco","year":"2024","journal-title":"Ther. Adv. Ophthalmol."},{"issue":"1","key":"2026092919102162300_cit145","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41433-019-0577-x","article-title":"The Impact of Artificial Intelligence in the Diagnosis and Management of Glaucoma","volume":"34","author":"Mayro","year":"2020","journal-title":"Eye"},{"key":"2026092919102162300_cit146","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.neucom.2020.07.146","article-title":"Automatic Method for Glaucoma Diagnosis Using a Three-Dimensional Convoluted Neural Network","volume":"438","author":"de Sales Carvalho","year":"2021","journal-title":"Neurocomputing"},{"issue":"5","key":"2026092919102162300_cit147","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1007\/s00138-020-01085-2","article-title":"DC-Gnet for Detection of Glaucoma in Retinal Fundus Imaging","volume":"31","author":"Juneja","year":"2020","journal-title":"Mach. Vis. Appl."},{"issue":"5","key":"2026092919102162300_cit148","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1007\/s00417-022-05912-2","article-title":"Psychological Interventions to Reduce Intraocular Pressure (IOP) in Glaucoma Patients: A Review","volume":"261","author":"Wu","year":"2023","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"issue":"1","key":"2026092919102162300_cit149","doi-asserted-by":"publisher","first-page":"92","DOI":"10.4103\/1673-5374.375319","article-title":"The Concept of Gene Therapy for Glaucoma: The Dream That Has Not Come True Yet","volume":"19","author":"Sulak","year":"2024","journal-title":"Neural Regen. Res."},{"key":"2026092919102162300_cit150","doi-asserted-by":"publisher","DOI":"10.1177\/20406223221140392","article-title":"Current Situation and Progress of Drugs for Reducing Intraocular Pressure","volume":"13","author":"Liu","year":"2022","journal-title":"Ther. Adv. Chronic Dis."},{"key":"2026092919102162300_cit151","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.3390\/jpm13111571","article-title":"Advances in Therapeutic Contact Lenses for the Management of Different Ocular Conditions","volume":"13","author":"Ioni\u021b\u0103","year":"2023","journal-title":"J. Pers. Med."},{"key":"2026092919102162300_cit152","doi-asserted-by":"publisher","DOI":"10.1016\/j.preteyeres.2020.100901","article-title":"Extraocular, Periocular, and Intraocular Routes for Sustained Drug Delivery for Glaucoma","volume":"82","author":"Kompella","year":"2021","journal-title":"Prog. Retin. Eye Res."},{"issue":"10","key":"2026092919102162300_cit153","doi-asserted-by":"publisher","first-page":"7290","DOI":"10.1021\/acsapm.2c01118","article-title":"Pressure-Triggered Microfluidic Contact Lens for Ocular Drug Delivery","volume":"4","author":"Du","year":"2022","journal-title":"ACS Appl. Polym. Mater."},{"issue":"2","key":"2026092919102162300_cit154","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajps.2026.101146","article-title":"MMP-9-Responsive Contact Lens Facilitating Disease-Adaptive and Safer Dexamethasone Delivery for Corneal Neovascularization Therapy","volume":"21","author":"Chu","year":"2026","journal-title":"Asian J. Pharm. Sci."},{"issue":"1","key":"2026092919102162300_cit155","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1016\/j.biomaterials.2013.09.032","article-title":"In Vivo Performance of a Drug-Eluting Contact Lens to Treat Glaucoma for a Month","volume":"35","author":"Ciolino","year":"2014","journal-title":"Biomaterials"},{"issue":"10","key":"2026092919102162300_cit156","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1016\/j.ophtha.2016.06.038","article-title":"Latanoprost-Eluting Contact Lenses in Glaucomatous Monkeys","volume":"123","author":"Ciolino","year":"2016","journal-title":"Ophthalmology"},{"key":"2026092919102162300_cit157","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1016\/j.jconrel.2012.06.017","article-title":"Extended Drug Delivery by Contact Lenses for Glaucoma Therapy","volume":"162","author":"Peng","year":"2012","journal-title":"J. Controlled Release"},{"issue":"3","key":"2026092919102162300_cit158","doi-asserted-by":"publisher","DOI":"10.1002\/adhm.201600775","article-title":"Zero-Order Antibiotic Release from Multilayer Contact Lenses: Nonuniform Drug and Diffusivity Distributions Produce Constant-Rate Drug Delivery","volume":"6","author":"Guzman","year":"2017","journal-title":"Adv. Healthcare Mater."},{"key":"2026092919102162300_cit159","doi-asserted-by":"publisher","DOI":"10.1016\/j.msec.2020.110885","article-title":"Multiple Drug Delivery from the Drug-Implants-Laden Silicone Contact Lens: Addressing the Issue of Burst Drug Release","volume":"112","author":"Desai","year":"2020","journal-title":"Mater. Sci. Eng., C"},{"issue":"6","key":"2026092919102162300_cit160","doi-asserted-by":"publisher","DOI":"10.1002\/advs.202412630","article-title":"Fish-Fin-Derived Non-Invasive Flexible Bioinspired Contact Lens for Continuous Ophthalmic Drug Delivery","volume":"12","author":"Li","year":"2025","journal-title":"Adv. Sci."},{"issue":"844","key":"2026092919102162300_cit161","doi-asserted-by":"publisher","DOI":"10.1126\/scitranslmed.ads9541","article-title":"Real-Time Intraocular Pressure Monitoring and Responsive Drug Release in Preclinical Models by an All-Polymer Smart Contact Lens","volume":"18","author":"Cai","year":"2026","journal-title":"Sci. Transl. Med."}],"container-title":["ACS Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acssensors.6c02609","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/ascefj\/article-pdf\/11\/9\/7870\/68464732\/se-2026-02609d.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/ascefj\/article-pdf\/11\/9\/7870\/68464732\/se-2026-02609d.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T08:11:51Z","timestamp":1790755911000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/ascefj\/article\/11\/9\/7870\/5427282\/Review-on-Intraocular-Pressure-Sensing-Systems"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,9]]},"references-count":161,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,9,9]]},"published-print":{"date-parts":[[2026,9,25]]}},"URL":"https:\/\/doi.org\/10.1021\/acssensors.6c02609","relation":{},"ISSN":["2379-3694"],"issn-type":[{"value":"2379-3694","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,9]]}}}