{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T15:10:39Z","timestamp":1791472239795,"version":"4.3.4"},"reference-count":19,"publisher":"American Chemical Society (ACS)","issue":"4","license":[{"start":{"date-parts":[[2019,3,26]],"date-time":"2019-03-26T00:00:00Z","timestamp":1553558400000},"content-version":"vor","delay-in-days":19,"URL":"https:\/\/pubs.acs.org\/page\/policy\/authorchoice_ccby_termsofuse.html"}],"funder":[{"DOI":"10.13039\/501100002341","name":"Suomen Akatemia","doi-asserted-by":"publisher","award":["317829"],"award-info":[{"award-number":["317829"]}],"id":[{"id":"10.13039\/501100002341","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008019","name":"\u00c5bo Akademi","doi-asserted-by":"publisher","award":["NA"],"award-info":[{"award-number":["NA"]}],"id":[{"id":"10.13039\/501100008019","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,4,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>A fundamental limitation of potentiometric ion sensors is their relatively low sensitivity due to the logarithmic dependence between potential and activity. Here we address this issue by exploring a recently developed coulometric transduction method for solid-contact ion-selective electrodes (SCISEs). Spin-coated thin-layer ion-selective membranes are used to lower the membrane resistance and shorten the response time of the SCISEs. When using coulometric transduction, an optimized design of the K+-SCISE is able to detect a concentration change of 5 \u03bcM at a concentration level of 5 mM, corresponding to a 0.1% change in K+ activity. This indicates that SCISEs can provide extremely high sensitivity when employing coulometric transduction. Impedance measurements show that the coulometric transduction process for the K+-SCISE is limited by diffusion even for very thin ion-selective membranes. On the other hand, the H+-SCISE shows a low impedance and a fast coulometric response that is related to the high mobility of H+ in the H+-selective polymeric membrane as well as in the solid contact layer. The coulometric transduction method was used to detect small changes of pH in seawater and found to improve the sensitivity compared to classical potentiometry. The coulometric method was briefly tested also for determining activity changes of K+ in a serum sample.<\/jats:p>","DOI":"10.1021\/acssensors.8b01649","type":"journal-article","created":{"date-parts":[[2019,3,7]],"date-time":"2019-03-07T16:56:26Z","timestamp":1551977786000},"page":"900-906","source":"Crossref","is-referenced-by-count":101,"title":["Improving the Sensitivity of Solid-Contact Ion-Selective\nElectrodes by Using Coulometric Signal Transduction"],"prefix":"10.1021","volume":"4","author":[{"given":"Tingting","family":"Han","sequence":"first","affiliation":[{"name":"\u00c5bo Akademi University , , Biskopsgatan 8 , , ,","place":["Turku\/\u00c5bo, Finland, FI-20500"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulriika","family":"Mattinen","sequence":"additional","affiliation":[{"name":"\u00c5bo Akademi University , , Biskopsgatan 8 , , ,","place":["Turku\/\u00c5bo, Finland, FI-20500"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2346-9947","authenticated-orcid":true,"given":"Johan","family":"Bobacka","sequence":"additional","affiliation":[{"name":"\u00c5bo Akademi University , , Biskopsgatan 8 , , ,","place":["Turku\/\u00c5bo, Finland, FI-20500"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2019,3,7]]},"reference":[{"key":"2026090310014066900_cit1","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-642-36886-8","volume-title":"Ion-selective electrodes","author":"Mikhelson","year":"2013"},{"key":"2026090310014066900_cit2","doi-asserted-by":"publisher","first-page":"3083","DOI":"10.1021\/cr940394a","article-title":"Carrier-based ion-selective\nelectrodes\nand bulk optodes. 1. General characteristics","volume":"97","author":"Bakker","year":"1997","journal-title":"Chem. Rev."},{"key":"2026090310014066900_cit3","doi-asserted-by":"publisher","first-page":"1593","DOI":"10.1021\/cr970113+","article-title":"Carrier-based ion-selective electrodes\nand bulk optodes. 2. Ionophores for potentiometric and optical sensors","volume":"98","author":"Bu\u0308hlmann","year":"1998","journal-title":"Chem. Rev."},{"key":"2026090310014066900_cit4","doi-asserted-by":"publisher","first-page":"11347","DOI":"10.1021\/ja972932h","article-title":"Large improvement of\nthe lower detection limit of ion-selective polymer membrane electrodes","volume":"119","author":"Sokalski","year":"1997","journal-title":"J. Am. Chem. Soc."},{"key":"2026090310014066900_cit5","first-page":"3","article-title":"Solid contact\nin membrane ion-selective electrodes","volume-title":"Ion-selective\nelectrode reviews","author":"Nikolskii","year":"1985"},{"key":"2026090310014066900_cit6","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1021\/cr068100w","article-title":"Potentiometric\nion sensors","volume":"108","author":"Bobacka","year":"2008","journal-title":"Chem. Rev."},{"key":"2026090310014066900_cit7","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1038\/nature16521","article-title":"Fully integrated\nwearable sensor arrays for multiplexed in situ perspiration\nanalysis","volume":"529","author":"Gao","year":"2016","journal-title":"Nature"},{"key":"2026090310014066900_cit8","first-page":"1354","article-title":"Electrolytes","volume-title":"Tietz Textbook\nof Clinical Chemistry","author":"Tietz","year":"1994"},{"key":"2026090310014066900_cit9","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.aca.2013.05.008","article-title":"Development\nof a colorimetric microfluidic pH sensor\nfor autonomous seawater measurements","volume":"786","author":"Re\u0301rolle","year":"2013","journal-title":"Anal.\nChim. Acta"},{"key":"2026090310014066900_cit10","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1002\/elan.201400596","article-title":"Novel ion to electron transduction\nprinciple for solid contact ISEs","volume":"27","author":"Hupa","year":"2015","journal-title":"Electroanalysis"},{"key":"2026090310014066900_cit11","doi-asserted-by":"publisher","first-page":"4369","DOI":"10.1021\/acs.analchem.5b04800","article-title":"New Signal\nReadout Principle for Solid-Contact Ion-Selective Electrodes","volume":"88","author":"Vanamo","year":"2016","journal-title":"Anal. Chem."},{"key":"2026090310014066900_cit12","doi-asserted-by":"publisher","first-page":"2071","DOI":"10.1002\/celc.201600575","article-title":"Influence of Electrode Geometry on\nthe Response of Solid Contact Ion Selective Electrodes when Utilizing\na New Coulometric Signal Readout Method","volume":"3","author":"Han","year":"2016","journal-title":"ChemElectroChem"},{"key":"2026090310014066900_cit13","doi-asserted-by":"publisher","first-page":"8700","DOI":"10.1021\/acs.analchem.8b02145","article-title":"Capacitive Model for\nCoulometric Readout of Ion-Selective Electrodes","volume":"90","author":"Jarolimova","year":"2018","journal-title":"Anal. Chem."},{"key":"2026090310014066900_cit14","doi-asserted-by":"publisher","first-page":"5260","DOI":"10.1039\/b907893b","article-title":"Thin layer\nelectrochemical extraction of non-redoxactive\ncations with an anion-exchanging conducting polymer overlaid with\na selective membrane","author":"Si","year":"2009","journal-title":"Chem. Commun."},{"key":"2026090310014066900_cit15","doi-asserted-by":"publisher","first-page":"4932","DOI":"10.1021\/ac990497z","article-title":"Potential\nstability of all-solid-state ion-selective electrodes using conducting\npolymers as ion-to-electron transducers","volume":"71","author":"Bobacka","year":"1999","journal-title":"Anal.\nChem."},{"key":"2026090310014066900_cit16","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1021\/acs.estlett.7b00388","article-title":"In Situ Detection of Species Relevant\nto the Carbon Cycle in Seawater with Submersible Potentiometric Probes","volume":"4","author":"Cuartero","year":"2017","journal-title":"Environ. Sci. Technol. Lett."},{"key":"2026090310014066900_cit17","doi-asserted-by":"publisher","first-page":"1176","DOI":"10.1021\/ac970952w","article-title":"Spectroscopic in situ\nimaging of acid coextraction\nprocesses in solvent polymeric ion-selective electrode and optode\nmembranes","volume":"70","author":"Lindner","year":"1998","journal-title":"Anal. Chem."},{"key":"2026090310014066900_cit18","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1016\/j.electacta.2015.11.050","article-title":"Optimization of capacitance of conducting\npolymer solid contact in ion-selective electrodes","volume":"187","author":"Plawinska","year":"2016","journal-title":"Electrochim. Acta"},{"key":"2026090310014066900_cit19","doi-asserted-by":"publisher","first-page":"8154","DOI":"10.1021\/ja0625780","article-title":"Potentiometry at trace\nlevels in confined samples: ion-selective electrodes with subfemtomole\ndetection limits","volume":"128","author":"Malon","year":"2006","journal-title":"J. Am. Chem. Soc."}],"container-title":["ACS Sensors"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/acssensors.8b01649","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/ascefj\/article-pdf\/4\/4\/900\/67259416\/acssensors.8b01649.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/ascefj\/article-pdf\/4\/4\/900\/67259416\/acssensors.8b01649.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T14:01:48Z","timestamp":1788444108000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/ascefj\/article\/4\/4\/900\/1386628\/Improving-the-Sensitivity-of-Solid-Contact-Ion"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,7]]},"references-count":19,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,3,7]]},"published-print":{"date-parts":[[2019,4,26]]}},"URL":"https:\/\/doi.org\/10.1021\/acssensors.8b01649","relation":{},"ISSN":["2379-3694"],"issn-type":[{"value":"2379-3694","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,7]]}}}