{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T15:49:30Z","timestamp":1791388170172,"version":"4.3.3"},"reference-count":79,"publisher":"American Chemical Society (ACS)","issue":"10","license":[{"start":{"date-parts":[[2026,8,21]],"date-time":"2026-08-21T00:00:00Z","timestamp":1787270400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,10,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Flow-rate-minimized electrospray ionization, commonly referred to as nanoelectrospray or, more simply, nanospray, has evolved into an essential foundational technology in the development and proliferation of mass spectrometric-based proteomic analysis. Historically, nanospray was an offline technique, termed herein as static nanospray. Static nanospray paired well with the leading protein purification method of the day: two-dimensional polyacrylamide gel electrophoresis (PAGE). The demands of analyzing ever more complex samples have evolved rapidly with the introduction of LC-based methodologies. The introduction of shotgun proteomics technology, taking inspiration from the development of shotgun-based genomic sequencing, enabled the analysis of whole-cell protein digests in a single LC-MS run. As mass spectrometry continued to improve in both sensitivity and speed over the decades, concomitant advances in nanobore LC column technology and emitter performance have occurred. Over the past 30 years, we have been fortunate to see sensitivity gains progress from isolated PAGE gel bands to single-cell proteomics. Here, I offer a personal perspective on the evolution of nanospray and nanobore LC-MS technology and on the journey of bringing these tools from the bench to the global scientific community through commercialization.<\/jats:p>","DOI":"10.1021\/jasms.6c00124","type":"journal-article","created":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T18:21:45Z","timestamp":1787509305000},"page":"2261-2272","source":"Crossref","is-referenced-by-count":0,"title":["A Personal Perspective\non the Technological and Commercial\nDevelopment of Nanospray and Nanobore LC-MS"],"prefix":"10.1021","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-6977-7346","authenticated-orcid":true,"given":"Gary A.","family":"Valaskovic","sequence":"first","affiliation":[{"name":"New Objective Inc. , 295 Foster St. Suite 110 , , ,","place":["Littleton, Massachusetts, United States, 01460-2022"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"316","published-online":{"date-parts":[[2026,8,21]]},"reference":[{"issue":"8","key":"2026100710070457500_cit1","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1021\/ac00008a010","article-title":"High Mass Resolution Secondary Ion\nMass Spectrometry via Simultaneous Detection with a Charge-Coupled\nDevice","volume":"63","author":"Mantus","year":"1991","journal-title":"Anal. Chem"},{"issue":"3\/4","key":"2026100710070457500_cit2","first-page":"269","article-title":"Polarized\nLight in Multiple Birefringent Domains: A Study of the Herzog Effect\nMicroscope","volume":"39","author":"Valaskovic","year":"1991","journal-title":"Microscope"},{"issue":"1","key":"2026100710070457500_cit3","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1111\/j.1365-2818.1995.tb03611.x","article-title":"Image Contrast of\nDielectric Specimens\nin Transmission Mode Near-Field Scanning Optical Microscopy: Imaging\nProperties and Tip Artefacts","volume":"179","author":"Valaskovic","year":"1995","journal-title":"J. Microsc"},{"issue":"2","key":"2026100710070457500_cit4","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/0168-1176(94)04024-9","article-title":"Electrospray and Taylor-Cone Theory, Dole\u2019s Beam of Macromolecules\nat Last?","volume":"136","author":"Wilm","year":"1994","journal-title":"Int. J. Mass Spectrom. Ion Processes"},{"issue":"7","key":"2026100710070457500_cit5","doi-asserted-by":"publisher","first-page":"1215","DOI":"10.1364\/AO.34.001215","article-title":"Parameter Control, Characterization,\nand Optimization in the Fabrication of Optical Fiber near-Field Probes","volume":"34","author":"Valaskovic","year":"1995","journal-title":"Appl. Opt"},{"issue":"1","key":"2026100710070457500_cit6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1021\/ac9509519","article-title":"Analytical Properties\nof the Nanoelectrospray Ion Source","volume":"68","author":"Wilm","year":"1996","journal-title":"Anal. Chem"},{"issue":"1","key":"2026100710070457500_cit7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1103\/PhysRev.10.1","article-title":"Instability\nof Electrified Liquid Surfaces","volume":"10","author":"Zeleny","year":"1917","journal-title":"Phys. Rev"},{"issue":"20","key":"2026100710070457500_cit8","doi-asserted-by":"publisher","first-page":"3802","DOI":"10.1021\/ac00116a030","article-title":"Attomole-Sensitivity\nElectrospray Source for Large-Molecule Mass Spectrometry","volume":"67","author":"Valaskovic","year":"1995","journal-title":"Anal. Chem"},{"key":"2026100710070457500_cit9","unstructured":"Valaskovic, G. A.; McLafferty, F. W.\n          Electrospray\nIonization Source and Method of Using the Same. US 5,788,166 A, 1998."},{"issue":"21","key":"2026100710070457500_cit10","doi-asserted-by":"publisher","first-page":"5739","DOI":"10.1021\/ac0301402","article-title":"Shifts in Peptide\nand Protein Charge State Distributions\nwith Varying Spray Tip Orifice Diameter in Nanoelectrospray Fourier\nTransform Ion Cycltron Resonance Mass Spectrometry","volume":"75","author":"Li","year":"2003","journal-title":"Anal. Chem"},{"issue":"18","key":"2026100710070457500_cit11","doi-asserted-by":"publisher","first-page":"8498","DOI":"10.1021\/ac402214g","article-title":"Electrospray Ionization\nfrom Nanopipette Emitters with Tip Diameters of Less than 100 Nm","volume":"85","author":"Yuill","year":"2013","journal-title":"Anal. Chem"},{"issue":"22","key":"2026100710070457500_cit12","doi-asserted-by":"publisher","first-page":"13541","DOI":"10.1021\/acs.analchem.8b03632","article-title":"Submicrometer Nanospray Emitters\nProvide New Insights into the Mechanism of Cation Adduction to Anionic\nOligonucleotides","volume":"90","author":"Kenderdine","year":"2018","journal-title":"Anal. Chem"},{"issue":"51","key":"2026100710070457500_cit13","doi-asserted-by":"publisher","first-page":"17972","DOI":"10.1021\/acs.analchem.2c04099","article-title":"Nanopore Liberates G-Quadruplexes\nfrom Biochemical Buffers for Accurate Mass Spectrometric Examination","volume":"94","author":"Lei","year":"2022","journal-title":"Anal. Chem"},{"issue":"3","key":"2026100710070457500_cit14","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1021\/jasms.1c00372","article-title":"Tips on\nMaking Tiny Tips: Secrets to Submicron Nanoelectrospray\nEmitters","volume":"33","author":"Jordan","year":"2022","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"3","key":"2026100710070457500_cit15","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1021\/jasms.1c00322","article-title":"Generation of Ions\nfrom Aqueous Taylor Cones near the\nMinimum Flow Rate: \u201cTrue Nanoelectrospray\u201d without Narrow\nCapillary","volume":"33","author":"Han","year":"2022","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"2","key":"2026100710070457500_cit16","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1006\/jcis.1996.4654","article-title":"Charge and Size Distributions of\nElectrospray Drops","volume":"186","author":"de Juan","year":"1997","journal-title":"J. Colloid Interface Sci"},{"issue":"7","key":"2026100710070457500_cit17","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1016\/1044-0305(93)85017-R","article-title":"Fourier-Transform\nElectrospray Instrumentation for Tandem High-Resolution Mass Spectrometry\nof Large Molecules","volume":"4","author":"Beu","year":"1993","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"12","key":"2026100710070457500_cit18","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1016\/S1044-0305(96)00152-3","article-title":"Long-Lived Metallized Tips for Nanoliter Electrospray\nMass Spectrometry","volume":"7","author":"Valaskovic","year":"1996","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"7","key":"2026100710070457500_cit19","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1002\/(SICI)1097-0231(199605)10:7&lt;825::AID-RCM569&gt;3.0.CO;2-Q","article-title":"Sampling Error in Small-Bore Sheathless Capillary Electrophoresis\/Electrospray-Ionization\nMass Spectrometry","volume":"10","author":"Valaskovic","year":"1996","journal-title":"Rapid Commun. Mass Spectrom"},{"issue":"5279","key":"2026100710070457500_cit20","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1126\/science.273.5279.1199","article-title":"Attomole\nProtein Characterization\nby Capillary Electrophoresis-Mass Spectrometry","volume":"273","author":"Valaskovic","year":"1996","journal-title":"Science"},{"key":"2026100710070457500_cit21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.cbpa.2020.04.018","article-title":"Single-Cell\nProtein Analysis by Mass Spectrometry","volume":"60","author":"Slavov","year":"2021","journal-title":"Curr.\nOpin. Chem. Biol"},{"issue":"3","key":"2026100710070457500_cit22","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1039\/C8AN01190G","article-title":"Recent Advances\nin Single-Cell Analysis by Mass Spectrometry","volume":"144","author":"Yin","year":"2019","journal-title":"Analyst"},{"issue":"11","key":"2026100710070457500_cit23","doi-asserted-by":"publisher","first-page":"1374","DOI":"10.1016\/j.tibtech.2022.04.004","article-title":"Single-Cell Mass Spectrometry","volume":"40","author":"Tajik","year":"2022","journal-title":"Trends Biotechnol"},{"issue":"17","key":"2026100710070457500_cit24","doi-asserted-by":"publisher","first-page":"4058","DOI":"10.1021\/ac000325y","article-title":"A Fully Integrated\nMonolithic Microchip Electrospray Device for Mass Spectrometry","volume":"72","author":"Schultz","year":"2000","journal-title":"Anal. Chem"},{"key":"2026100710070457500_cit25","doi-asserted-by":"publisher","DOI":"10.1002\/mas.70021","article-title":"The TriVersa\nNanoMate: Automation\nof Nano Electrospray Analyses","author":"Prosser","year":"2026","journal-title":"Mass Spectrom.\nRev"},{"issue":"1","key":"2026100710070457500_cit26","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1021\/ac302789c","article-title":"Unraveling the Mechanism\nof Electrospray Ionization","volume":"85","author":"Konermann","year":"2013","journal-title":"Anal. Chem"},{"issue":"15","key":"2026100710070457500_cit27","doi-asserted-by":"publisher","first-page":"10807","DOI":"10.1021\/acs.analchem.0c02290","article-title":"Formation\nof Gaseous Proteins via the Ion Evaporation\nModel (IEM) in Electrospray Mass Spectrometry","volume":"92","author":"Aliyari","year":"2020","journal-title":"Anal. Chem"},{"issue":"21","key":"2026100710070457500_cit28","doi-asserted-by":"publisher","first-page":"7713","DOI":"10.1021\/acs.analchem.2c01355","article-title":"Formation of Gaseous Peptide Ions\nfrom Electrospray\nDroplets: Competition between the Ion Evaporation Mechanism and Charged\nResidue Mechanism","volume":"94","author":"Aliyari","year":"2022","journal-title":"Anal. Chem"},{"issue":"4","key":"2026100710070457500_cit29","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1016\/S1044-0305(98)00157-3","article-title":"Nanoelectrospray\u2013More than\nJust a Minimized-Flow Electrospray Ionization Source","volume":"10","author":"Juraschek","year":"1999","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"5","key":"2026100710070457500_cit30","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1016\/S1044-0305(03)00128-4","article-title":"Effect of\nDifferent Solution Flow\nRates on Analyte Ion Signals in Nano-ESI MS, or: When Does ESI Turn\ninto Nano-ESI?","volume":"14","author":"Schmidt","year":"2003","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"7","key":"2026100710070457500_cit31","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1002\/rcm.2414","article-title":"Ultra-low Flow Nanospray\nfor the Normalization of Conventional Liquid Chromatography\/Mass Spectrometry\nthrough Equimolar Response: Standard-free Quantitative Estimation\nof Metabolite Levels in Drug Discovery","volume":"20","author":"Valaskovic","year":"2006","journal-title":"Rapid\nCommun. Mass Spectrom"},{"issue":"14","key":"2026100710070457500_cit32","doi-asserted-by":"publisher","first-page":"2295","DOI":"10.1002\/rcm.3093","article-title":"Evaluation\nof High-Field Asymmetric\nWaveform Ion Mobility Spectrometry Coupled to Nanoelectrospray Ionization\nfor Bioanalysis in Drug Discovery","volume":"21","author":"Hatsis","year":"2007","journal-title":"Rapid Commun.\nMass Spectrom"},{"issue":"23","key":"2026100710070457500_cit33","doi-asserted-by":"publisher","first-page":"3736","DOI":"10.1002\/rcm.4311","article-title":"Online Nanoelectrospray\/High-Field\nAsymmetric Waveform Ion Mobility Spectrometry as a Potential Tool\nfor Discovery Pharmaceutical Bioanalysis","volume":"23","author":"Hatsis","year":"2009","journal-title":"Rapid\nCommun. Mass Spectrom"},{"issue":"11","key":"2026100710070457500_cit34","first-page":"954","article-title":"Revival of Capillary Electrophoretic Techniques in\nthe Pharmaceutical Industry | LCGC International","volume":"30","author":"Sa\u0308nger-van de Griend","year":"2012","journal-title":"LCGC North Am."},{"issue":"7","key":"2026100710070457500_cit35","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1016\/1044-0305(94)85001-1","article-title":"Micro-Electrospray Mass Spectrometry: Ultra-High-Sensitivity\nAnalysis of Peptides and Proteins","volume":"5","author":"Emmett","year":"1994","journal-title":"J. Am. Soc.\nMass Spectrom"},{"key":"2026100710070457500_cit36","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/978-3-0348-5678-2_26","article-title":"Protein and\nPeptide Sequence Analysis by Tandem Mass Spectrometry in Combination\nwith Either Capillary Electrophoresis or Micro-Capillary HPLC","volume-title":"Methods in Protein Sequence Analysis","author":"Hunt","year":"1991"},{"issue":"10","key":"2026100710070457500_cit37","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1016\/S0167-7799(97)01110-4","article-title":"Emerging\nTandem-Mass-Spectrometry\nTechniques for the Rapid Identification of Proteins","volume":"15","author":"Dongre\u0301","year":"1997","journal-title":"Trends Biotechnol"},{"issue":"2","key":"2026100710070457500_cit38","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1155\/2002\/505397","article-title":"Shotgun Proteomics and Biomarker\nDiscovery","volume":"18","author":"McDonald","year":"2002","journal-title":"Dis. Markers"},{"issue":"8","key":"2026100710070457500_cit39","doi-asserted-by":"publisher","first-page":"446","DOI":"10.1002\/jhrc.1240100805","article-title":"Porous Ceramic Bed\nSupports for Fused Silica Packed Capillary Columns Used in Liquid\nChromatography","volume":"10","author":"Cortes","year":"1987","journal-title":"J. High Resolut. Chromatogr"},{"issue":"5\u20136","key":"2026100710070457500_cit40","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1002\/mas.1280130504","article-title":"Capillary Liquid\nChromatography\/Mass Spectrometry","volume":"13","author":"Tomer","year":"1994","journal-title":"Mass Spectrom.\nRev"},{"key":"2026100710070457500_cit41","unstructured":"Valaskovic, G. A.\n          \n          Evaporative\nPacking of Capillary Columns. US 5,997,746 A, 1999."},{"key":"2026100710070457500_cit42","unstructured":"Valaskovic, G. A.; Ehrenfeld, E. E.\n          Method\nfor Packing Capillary Columns with Particulate Materials. EP 1,361,912 B1, 2009."},{"issue":"12","key":"2026100710070457500_cit43","doi-asserted-by":"publisher","first-page":"1262","DOI":"10.1016\/S1044-0305(01)00312-9","article-title":"Effects of\nthe Position of Internal Histidine Residues\non the Collision-Induced Fragmentation of Triply Protonated Tryptic\nPeptides","volume":"12","author":"Willard","year":"2001","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"15","key":"2026100710070457500_cit44","doi-asserted-by":"publisher","first-page":"3864","DOI":"10.1002\/pmic.200401259","article-title":"Simple and Effective\nTechnical Procedures for the Packing and Application of Nanospray\nPicoFrit HPLC Columns for Proteomic Analyses","volume":"5","author":"Howells","year":"2005","journal-title":"Proteomics"},{"issue":"23","key":"2026100710070457500_cit45","doi-asserted-by":"publisher","first-page":"3425","DOI":"10.1002\/rcm.4787","article-title":"Folded Emitters\nfor Nanoelectrospray Ionization Mass Spectrometry","volume":"24","author":"Kirby","year":"2010","journal-title":"Rapid Commun. Mass Spectrom"},{"issue":"17","key":"2026100710070457500_cit46","doi-asserted-by":"publisher","first-page":"7256","DOI":"10.1021\/ac9015038","article-title":"Spray Performance of\nMicrofluidic Glass Devices with Integrated Pulled Nanoelectrospray\nEmitters","volume":"81","author":"Hoffmann","year":"2009","journal-title":"Anal. Chem"},{"issue":"21","key":"2026100710070457500_cit47","doi-asserted-by":"publisher","first-page":"8973","DOI":"10.1021\/ac301602b","article-title":"Integration\nof Fully Microfabricated,\nThree-Dimensionally Sharp Electrospray Ionization Tips with Microfluidic\nGlass Chips","volume":"84","author":"Sainiemi","year":"2012","journal-title":"Anal. Chem"},{"issue":"6","key":"2026100710070457500_cit48","doi-asserted-by":"publisher","first-page":"1631","DOI":"10.1021\/ac048506d","article-title":"Integrated Microfluidic\nDevice for Mass Spectrometry-Based Proteomics and Its Application\nto Biomarker Discovery Programs","volume":"77","author":"Fortier","year":"2005","journal-title":"Anal. Chem"},{"issue":"5","key":"2026100710070457500_cit49","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1016\/S1044-0305(00)00111-2","article-title":"Generation\nof Electrospray from a\nSolution Predeposited on Optical Fibers Coiled with a Platinum Wire","volume":"11","author":"Kuo","year":"2000","journal-title":"J. Am. Soc. Mass Spectrom"},{"issue":"2","key":"2026100710070457500_cit50","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1021\/ac990967p","article-title":"A Micromachined\nChip-Based Electrospray Source for Mass Spectrometry","volume":"72","author":"Licklider","year":"2000","journal-title":"Anal. Chem"},{"issue":"15","key":"2026100710070457500_cit51","doi-asserted-by":"publisher","first-page":"7712","DOI":"10.1021\/ac5016408","article-title":"Paper Spray and Extraction Spray\nMass Spectrometry for the Direct and Simultaneous Quantification of\nEight Drugs of Abuse in Whole Blood","volume":"86","author":"Espy","year":"2014","journal-title":"Anal. Chem"},{"issue":"1","key":"2026100710070457500_cit52","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1021\/ac010748f","article-title":"A Conductive\nPolymeric Material Used for Nanospray Needle and Low-Flow Sheathless\nElectrospray Ionization Applications","volume":"74","author":"Wetterhall","year":"2002","journal-title":"Anal.\nChem"},{"issue":"21","key":"2026100710070457500_cit53","doi-asserted-by":"publisher","first-page":"6456","DOI":"10.1021\/ac049438y","article-title":"Porous Polymer Monolith\nAssisted Electrospray","volume":"76","author":"Koerner","year":"2004","journal-title":"Anal. Chem"},{"issue":"3","key":"2026100710070457500_cit54","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1021\/ac9607119","article-title":"Multichannel Microchip\nElectrospray Mass Spectrometry","volume":"69","author":"Xue","year":"1997","journal-title":"Anal. Chem"},{"issue":"50","key":"2026100710070457500_cit55","doi-asserted-by":"publisher","first-page":"20107","DOI":"10.1021\/acs.analchem.4c05171","article-title":"Novel Pinhole Emitter Chip for Micro\nSupercritical Fluid Chromatography\u2013Mass Spectrometry with Integrated\nDilution-Free Fluidic Back-Pressure Regulation","volume":"96","author":"Schwieger","year":"2024","journal-title":"Anal. Chem"},{"issue":"13","key":"2026100710070457500_cit56","doi-asserted-by":"publisher","first-page":"3599","DOI":"10.1021\/ac030419i","article-title":"Electrospray Ionization\nwith a Pointed Carbon Fiber Emitter","volume":"76","author":"Liu","year":"2004","journal-title":"Anal. Chem"},{"issue":"22","key":"2026100710070457500_cit57","doi-asserted-by":"publisher","first-page":"5897","DOI":"10.1021\/ac020396s","article-title":"An Electrospray\nIonization Source\nfor Integration with Microfluidics","volume":"74","author":"Kameoka","year":"2002","journal-title":"Anal. Chem"},{"issue":"10","key":"2026100710070457500_cit58","doi-asserted-by":"publisher","first-page":"5072","DOI":"10.1021\/acs.analchem.5b03990","article-title":"Generating\nElectrospray Ionization on Ballpoint Tips","volume":"88","author":"Ji","year":"2016","journal-title":"Anal.\nChem"},{"issue":"3","key":"2026100710070457500_cit59","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.jasms.2003.11.001","article-title":"A Novel Nib-like\nDesign for Microfabricated Nanospray Tips","volume":"15","author":"Le Gac","year":"2004","journal-title":"J.\nAm. Soc. Mass Spectrom"},{"issue":"8","key":"2026100710070457500_cit60","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1021\/ac001191r","article-title":"Generation of Multiple\nElectrosprays Using Microfabricated Emitter Arrays for Improved Mass\nSpectrometric Sensitivity","volume":"73","author":"Tang","year":"2001","journal-title":"Anal. Chem"},{"issue":"17","key":"2026100710070457500_cit61","doi-asserted-by":"publisher","first-page":"7281","DOI":"10.1021\/ac901026t","article-title":"Microstructured\nPhotonic Fibers as Multichannel Electrospray Emitters","volume":"81","author":"Su","year":"2009","journal-title":"Anal. Chem"},{"issue":"10","key":"2026100710070457500_cit62","doi-asserted-by":"publisher","first-page":"3703","DOI":"10.1021\/ac070010j","article-title":"Microfabricated Monolithic Multinozzle\nEmitters for Nanoelectrospray Mass Spectrometry","volume":"79","author":"Kim","year":"2007","journal-title":"Anal. Chem"},{"issue":"19","key":"2026100710070457500_cit63","doi-asserted-by":"publisher","first-page":"7204","DOI":"10.1021\/acs.analchem.1c00200","article-title":"Coupling Miniaturized\nFree-Flow Electrophoresis to Mass Spectrometry via a Multi-Emitter\nESI Interface","volume":"93","author":"Jender","year":"2021","journal-title":"Anal. Chem"},{"issue":"8","key":"2026100710070457500_cit64","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1016\/j.jasms.2004.04.033","article-title":"Automated\nOrthogonal Control System\nfor Electrospray Ionization","volume":"15","author":"Valaskovic","year":"2004","journal-title":"J. Am. Soc. Mass\nSpectrom"},{"issue":"2","key":"2026100710070457500_cit65","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1021\/ac049068d","article-title":"Microfluidic Chip for Peptide Analysis with an Integrated\nHPLC Column, Sample Enrichment Column, and Nanoelectrospray Tip","volume":"77","author":"Yin","year":"2005","journal-title":"Anal. Chem"},{"key":"2026100710070457500_cit66","volume-title":"Easy-to-Use, Plug-and-Spray\nIon Source for Robust and Reproducible Ultra High Pressure Nanoflow\nLC\/MS, 2112","author":"Kiyonami","year":"2012"},{"issue":"10","key":"2026100710070457500_cit67","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1021\/cen-09510-bus1","article-title":"Top instrument\nfirms","volume":"95","author":"Thayer","year":"2017","journal-title":"CEN Glob. Enterp"},{"key":"2026100710070457500_cit68","unstructured":"Valaskovic, G.; Ngo, B.; Devlin, J. P.; Maw, K. M.; Schon, I.\n          Integrated\nNanospray\nSystem. US 9,646,815 B2, 2017."},{"issue":"7","key":"2026100710070457500_cit69","doi-asserted-by":"publisher","first-page":"2732","DOI":"10.1021\/acs.jproteome.9b00671","article-title":"Accelerated\nProtein Biomarker Discovery from FFPE Tissue Samples Using Single-Shot,\nShort Gradient Microflow SWATH MS","volume":"19","author":"Sun","year":"2020","journal-title":"J. Proteome\nRes"},{"issue":"1","key":"2026100710070457500_cit70","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.cels.2020.05.012","article-title":"Ultra-High-Throughput\nClinical Proteomics Reveals Classifiers of COVID-19 Infection","volume":"11","author":"Messner","year":"2020","journal-title":"Cell Syst"},{"issue":"7\u20138","key":"2026100710070457500_cit71","doi-asserted-by":"publisher","first-page":"2200013","DOI":"10.1002\/pmic.202200013","article-title":"Mass Spectrometry-Based\nHigh-Throughput\nProteomics and Its Role in Biomedical Studies and Systems Biology","volume":"23","author":"Messner","year":"2023","journal-title":"Proteomics"},{"issue":"10","key":"2026100710070457500_cit72","doi-asserted-by":"publisher","first-page":"4988","DOI":"10.1021\/acs.jproteome.5c00327","article-title":"High-Performance Proteomics Using\nNano-, Capillary-, and Microflow Chromatographic Separations","volume":"24","author":"Tsiklauri","year":"2025","journal-title":"J. Proteome Res"},{"issue":"3","key":"2026100710070457500_cit73","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1080\/14789450.2022.2134780","article-title":"On the Potential\nof Micro-Flow LC-MS\/MS in Proteomics","volume":"19","author":"Bian","year":"2022","journal-title":"Expert\nRev. Proteomics"},{"key":"2026100710070457500_cit74","doi-asserted-by":"publisher","DOI":"10.1101\/2023.06.05.543682","article-title":"One\nThousand Samples per Day Capillary-Flow LC\/MS\/MS for High-Speed, High-Sensitivity\nand in-Depth Proteomics","author":"Tomioka","year":"2023","journal-title":"bioRxiv"},{"issue":"3","key":"2026100710070457500_cit75","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1002\/mas.10026","article-title":"Naturally and Externally\nPulsed Electrospray","volume":"21","author":"Wei","year":"2002","journal-title":"Mass Spectrom. Rev"},{"issue":"1","key":"2026100710070457500_cit76","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S1387-3806(98)14025-3","article-title":"Pulsation\nPhenomena during Electrospray Ionization","volume":"177","author":"Juraschek","year":"1998","journal-title":"Int.\nJ. Mass Spectrom"},{"issue":"42","key":"2026100710070457500_cit77","doi-asserted-by":"publisher","first-page":"43211","DOI":"10.1021\/acsomega.4c07653","article-title":"Does the Formation of a Taylor Cone\nin a Pulsating\nElectrospray Directly Impact Mass Spectrometry Signals?","volume":"9","author":"Chang","year":"2024","journal-title":"ACS Omega"},{"key":"2026100710070457500_cit78","unstructured":"Valaskovic, G. A.\n          \n          Method\nand Device for Improved Performance with Micro-Electrospray Ionization. US\n12,211,684 B2, 2025."},{"issue":"1","key":"2026100710070457500_cit79","doi-asserted-by":"publisher","first-page":"32357","DOI":"10.1038\/srep32357","article-title":"The Onset of Electrospray: The Universal Scaling Laws\nof the First Ejection","volume":"6","author":"Gan\u0303a\u0301n-Calvo","year":"2016","journal-title":"Sci. Rep"}],"container-title":["Journal of the American\nSociety for Mass Spectrometry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.acs.org\/doi\/pdf\/10.1021\/jasms.6c00124","content-type":"application\/pdf","content-version":"vor","intended-application":"unspecified"},{"URL":"https:\/\/pubs.acs.org\/jamsef\/article-pdf\/37\/10\/2261\/67061764\/jasms.6c00124.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.acs.org\/jamsef\/article-pdf\/37\/10\/2261\/67061764\/jasms.6c00124.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T14:49:24Z","timestamp":1791384564000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.acs.org\/jamsef\/article\/37\/10\/2261\/5293283\/A-Personal-Perspective-on-the-Technological-and"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,21]]},"references-count":79,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,8,21]]},"published-print":{"date-parts":[[2026,10,7]]}},"URL":"https:\/\/doi.org\/10.1021\/jasms.6c00124","relation":{},"ISSN":["1044-0305","1879-1123"],"issn-type":[{"value":"1044-0305","type":"print"},{"value":"1879-1123","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,21]]}}}