{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,5]],"date-time":"2025-07-05T04:09:30Z","timestamp":1751688570288,"version":"3.41.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2000,11,1]],"date-time":"2000-11-01T00:00:00Z","timestamp":973036800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2000,11,1]],"date-time":"2000-11-01T00:00:00Z","timestamp":973036800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Systems Integration"],"published-print":{"date-parts":[[2000,11]]},"DOI":"10.1023\/a:1026559301696","type":"journal-article","created":{"date-parts":[[2003,11,6]],"date-time":"2003-11-06T17:11:16Z","timestamp":1068138676000},"page":"55-66","source":"Crossref","is-referenced-by-count":0,"title":["Morphological and Biomechanical Studies of Pedicle Screw Fixation for the Lower Cervical Spine"],"prefix":"10.1007","volume":"10","author":[{"given":"Naiquan","family":"Zheng","sequence":"first","affiliation":[]},{"given":"Ken","family":"Yong-Hing","sequence":"additional","affiliation":[]},{"given":"L. Glen","family":"Watson","sequence":"additional","affiliation":[]}],"member":"297","reference":[{"issue":"11","key":"278957_CR1","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1097\/00007632-198911000-00019","volume":"14","author":"K. Abumi","year":"1989","unstructured":"K. Abumi, M. M. Panjabi, and J. Duraneau, \u201cBiomehanical evaluation of spinal fixation devices. Part III. Stability provided by six spinal fixation devices and interbody bone graft.\u201d Spine 14(11), pp. 1249\u20131255, 1989.","journal-title":"Spine"},{"issue":"12","key":"278957_CR2","doi-asserted-by":"crossref","first-page":"1398","DOI":"10.1097\/00007632-198912000-00019","volume":"14","author":"R. B. Ashman","year":"1989","unstructured":"R. B. Ashman, R. D. Galpin, and J. D. Corin et al., \u201cBiomehanical analysis of pedicle screw instrumentation systems in a corpectomy model.\u201d Spine 14(12), pp. 1398\u20131405, 1989.","journal-title":"Spine"},{"key":"278957_CR3","doi-asserted-by":"crossref","first-page":"939","DOI":"10.3928\/0147-7447-19890701-06","volume":"12","author":"C. J. Banta","year":"1989","unstructured":"C. J. Banta, A. G. King, and E. J. Dobezies et al., \u201cMeasurement of effective pedicle diameter in the human spine.\u201d Orthopaedics 12, pp. 939\u2013942, 1989.","journal-title":"Orthopaedics"},{"key":"278957_CR4","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1097\/00007632-198705000-00010","volume":"12","author":"J. L. Berry","year":"1987","unstructured":"J. L. Berry, J. M. Moran, and W. S. Berg et al., \u201cA morphometric study of human lumbar and selected thoracic vertebrae.\u201d Spine 12, pp. 362\u2013367, 1987.","journal-title":"Spine"},{"key":"278957_CR5","first-page":"10","volume":"227","author":"Y. Cottrel","year":"1988","unstructured":"Y. Cottrel, J. Dubousset, and M. Guillaumat, \u201cNewuniversal instrumentation in spinal surgery.\u201d Clin. Orthop. 227, pp. 10\u201323, 1988.","journal-title":"Clin. Orthop."},{"key":"278957_CR6","volume-title":"ANSYS Engineering Analysis System, User's Manual","author":"G. J. DeSalvo","year":"1989","unstructured":"G. J. DeSalvo and R.W. Gorman, ANSYS Engineering Analysis System, User's Manual. Swanson Analysis System, Inc.: Houston, Pa., May, 1989."},{"issue":"2","key":"278957_CR7","first-page":"181","volume":"16","author":"D. C. George","year":"1991","unstructured":"D. C. George, M. H. Krag, and C. C. Johnson et al., \u201cHole preparation techniques for transpedicle screw: Effects on pull-out strength from human cadaveric vertebrae.\u201d Spine 16(2), pp. 181\u2013184, 1991.","journal-title":"Spine"},{"issue":"9","key":"278957_CR8","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1097\/00007632-198809000-00007","volume":"13","author":"V. K. Goel","year":"1988","unstructured":"V. K. Goel, Y. E. Kim, and T. H. Lim et al., \u201cAn analysis investigation of the mechanics of spinal instrumentation.\u201d Spine 13(9), pp. 1003\u20131011, 1988.","journal-title":"Spine"},{"issue":"2","key":"278957_CR9","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1097\/00007632-199102000-00016","volume":"16","author":"R. Gunzburg","year":"1991","unstructured":"R. Gunzburg and R. D. Fraser, \u201cStress fracture of the lumbar pedicle, case reports of \u201cpediculolysis\u201d and review of the literature.\u201d Spine 16(2), pp. 185\u2013189, 1991.","journal-title":"Spine"},{"key":"278957_CR10","first-page":"75","volume":"203","author":"M. H. Krag","year":"1986","unstructured":"M. H. Krag, B. D. Beynnon, and M. H. Pope et al., \u201cShort segments of the thoracic, lumbar, or lumbosacral spine, design and testing.\u201d Clin. Orthop. 203, pp. 75\u201397, 1986.","journal-title":"Clin. Orthop."},{"issue":"1","key":"278957_CR11","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/00007632-198801000-00007","volume":"13","author":"M. H. Krag","year":"1988","unstructured":"M. H. Krag, D. L. Weaver, B. D. Beynnon, and L. D. Haugh, \u201cMorphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation.\u201d Spine 13(1), pp. 27\u201332, 1988.","journal-title":"Spine"},{"issue":"11","key":"278957_CR12","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1097\/00007632-199011010-00014","volume":"15","author":"H. Matsuzaki","year":"1990","unstructured":"H. Matsuzaki, Y. Tokuhashi, and F. Matsumoto et al., \u201cProblems and solutions of pedicle screw plate fixation of lumbar spine.\u201d Spine 15(11), pp. 1159\u20131165, 1990.","journal-title":"Spine"},{"issue":"4","key":"278957_CR13","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1097\/00007632-198904000-00004","volume":"14","author":"G. R. Misenhimer","year":"1989","unstructured":"G. R. Misenhimer, R. D. Peek, and L. L. Willtse et al., \u201cAnatomic analysis of pedicle cortical and cancellous diameter as related to screw size.\u201d Spine 14(4), pp. 368\u2013372, 1989.","journal-title":"Spine"},{"issue":"3suppl.","key":"278957_CR14","doi-asserted-by":"crossref","first-page":"s10","DOI":"10.1097\/00007632-199103001-00004","volume":"16","author":"P. X. Montesano","year":"1991","unstructured":"P. X. Montesano, E. C. Juach, and P. A. Anderson et al., \u201cBiomechanics of cervical spine internal fixation.\u201d Spine 16(3, suppl.), pp. s10\u2013s16, 1991.","journal-title":"Spine"},{"issue":"1","key":"278957_CR15","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1002\/jor.1100070115","volume":"7","author":"J. M. Moran","year":"1989","unstructured":"J. M. Moran, W. S. Berg, and J. L. Berry et al., \u201cTranspedicular screw fixation.\u201d J. Orthop. Res. 7(1), pp. 107\u2013114, 1989.","journal-title":"J. Orthop. Res."},{"key":"278957_CR16","doi-asserted-by":"crossref","first-page":"541","DOI":"10.2106\/00004623-199072040-00011","volume":"72A","author":"J. M. Olsewski","year":"1990","unstructured":"J. M. Olsewski, E. H. Simmons, and F. C. Kallen et al., \u201cMorphometry of the lumbar spine: Anatomical perspectives related to transpedicular fixation.\u201d J. Bone Joint Surg. 72A, pp. 541\u2013549, 1990.","journal-title":"J. Bone Joint Surg."},{"issue":"10","key":"278957_CR17","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1097\/00007632-198810000-00014","volume":"13","author":"M. M. Panjabi","year":"1988","unstructured":"M. M. Panjabi, K. Abumi, and J. Duranceau et al., \u201cBiomechanical evaluation of spinal fixation devices: II. Stability provided by eight internal fixation devices.\u201d Spine 13(10), pp. 1135\u20131140, 1988.","journal-title":"Spine"},{"issue":"10","key":"278957_CR18","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1097\/00007632-198810000-00014","volume":"13","author":"M. M. Panjabi","year":"1988","unstructured":"M. M. Panjabi, K. Abumi, and J. Duranceau et al., \u201cBiomechanical evaluation of spinal fixation devices: II. Stability provided by eight internal fixation devices.\u201d Spine 13(10), pp. 1135\u20131140, 1988.","journal-title":"Spine"},{"key":"278957_CR19","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/0021-9290(78)90012-X","volume":"111","author":"M. M. Panjabi","year":"1978","unstructured":"M. M. Panjabi, A. A. White, and D. Keller et al., \u201cStability of the cervical spine under tension.\u201d J. Biomech. 111, pp. 189, 1978.","journal-title":"J. Biomech."},{"key":"278957_CR20","first-page":"151","volume":"62","author":"G. Saillant","year":"1976","unstructured":"G. Saillant, \u201cEtude anatonique des pedicles vertebreau, application chirurgicales.\u201d Res Chir Orthop Traumatatol 62, pp. 151\u2013160, 1976.","journal-title":"Res Chir Orthop Traumatatol"},{"key":"278957_CR21","first-page":"200","volume":"109","author":"K. Ueno","year":"1987","unstructured":"K. Ueno and Y. K. Liu, \u201cA three-dimensional nonlinear finite element model for lumbar intervertebral joint in torsion.\u201d J. Biomed. Eng. 109, p. 200, Aug. 1987.","journal-title":"J. Biomed. Eng."},{"unstructured":"N. Zheng, \u201cAn investigation of pedicle screw fixation for the lower cervical spine.\u201d MSc thesis, University of Saskatchewan, 1991.","key":"278957_CR22"},{"key":"278957_CR23","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/00007632-198703000-00012","volume":"12","author":"M. R. Zindrick","year":"1987","unstructured":"M. R. Zindrick, L. L. Wiltse, and E. H. Widell et al., \u201cAnalysis of the morphometric characteristics of the thoracic and lumbar pedicles.\u201d Spine 12, pp. 160\u2013166, 1987.","journal-title":"Spine"}],"container-title":["Journal of Systems Integration"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1023\/A:1026559301696.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1023\/A:1026559301696\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1023\/A:1026559301696.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,4]],"date-time":"2025-07-04T12:51:17Z","timestamp":1751633477000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1023\/A:1026559301696"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2000,11]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2000,11]]}},"alternative-id":["278957"],"URL":"https:\/\/doi.org\/10.1023\/a:1026559301696","relation":{},"ISSN":["0925-4676","1573-8787"],"issn-type":[{"type":"print","value":"0925-4676"},{"type":"electronic","value":"1573-8787"}],"subject":[],"published":{"date-parts":[[2000,11]]}}}