{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,13]],"date-time":"2023-09-13T17:21:10Z","timestamp":1694625670794},"reference-count":0,"publisher":"Hogrefe Publishing Group","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vasa"],"published-print":{"date-parts":[[1999,5,1]]},"abstract":"<jats:p> Background: Despite the continuing high incidence of deep vein thrombosis after total hip arthroplasty, currently available mechanical thromboprophylactic systems are not sufficiently utilised in Germany. Patients and methods: Duplex-sonographic measurements of the maximum venous flow velocity (V. femoralis) in 10 healthy individuals performed with a leg orientation synonymous to that during total hip arthroplasty were compared to figures obtained during an out-stretched leg position. Additionally, duplex-sonography was conducted on 9 patients intra-operatively during total hip replacement to complete the study. All investigations were executed both with and without application of the A-V Impulse System (AVIS), a mechanical thromboprophylactic procedure. Results: In contrast to the out-stretched leg position, a decreased venous peak flow velocity during surgery as well as in the operation-identical leg orientation was demonstrated in the absence of AVIS. However, by means of AVIS, a significant increase in the venous peak flow velocity (p &lt; 0.01) was achieved for both situations. Additionally, an increased vessel diameter of the V. femoralis communis was observed in 75% of patients due to the leg orientation stipulated for hip replacement surgery. Conclusion: The data suggest that the A-V Impulse System can effectively accelerate the venous reflux-flow during operations involving hip replacements and thus provide an early preventative therapy for deep vein thrombosis after a surgical procedure. <\/jats:p>","DOI":"10.1024\/0301-1526.28.2.112","type":"journal-article","created":{"date-parts":[[2006,1,31]],"date-time":"2006-01-31T12:25:05Z","timestamp":1138710305000},"page":"112-116","source":"Crossref","is-referenced-by-count":0,"title":["Das arterioven\u00f6se Impuls-System bei totaler H\u00fcftalloarthroplastik"],"prefix":"10.1024","volume":"28","author":[{"family":"Eidner","sequence":"first","affiliation":[{"name":"Departments of Internal Medicine, Friedrich-Schiller University Jena, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"family":"P\u00f6hlmann","sequence":"additional","affiliation":[{"name":"Departments of Internal Medicine, Friedrich-Schiller University Jena, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"family":"Anders","sequence":"additional","affiliation":[{"name":"Departments of Orthopaedy, Friedrich-Schiller University Jena, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"family":"Grohmann","sequence":"additional","affiliation":[{"name":"Departments of Internal Medicine, Friedrich-Schiller University Jena, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"101","container-title":["Vasa"],"original-title":[],"language":"de","link":[{"URL":"https:\/\/econtent.hogrefe.com\/doi\/pdf\/10.1024\/0301-1526.28.2.112","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,5,8]],"date-time":"2022-05-08T10:49:53Z","timestamp":1652006993000},"score":1,"resource":{"primary":{"URL":"https:\/\/econtent.hogrefe.com\/doi\/10.1024\/0301-1526.28.2.112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,5,1]]},"references-count":0,"journal-issue":{"issue":"2","published-print":{"date-parts":[[1999,5,1]]}},"alternative-id":["10.1024\/0301-1526.28.2.112"],"URL":"https:\/\/doi.org\/10.1024\/0301-1526.28.2.112","relation":{},"ISSN":["0301-1526","1664-2872"],"issn-type":[{"value":"0301-1526","type":"print"},{"value":"1664-2872","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,5,1]]}}}