{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T09:48:22Z","timestamp":1695894502071},"reference-count":26,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2001,12,24]],"date-time":"2001-12-24T00:00:00Z","timestamp":1009152000000},"content-version":"vor","delay-in-days":663,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Anaesthesiol Scand"],"published-print":{"date-parts":[[2000,3]]},"abstract":"<jats:p><jats:bold>Background:<\/jats:bold> Several hydroxyethyl starch (HES) solutions are available clinically. We performed comparative studies of low and high molecular weight HES to evaluate the effects on lung lymph flow in sheep, to see the difference in the types of HES.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> We prepared awake sheep with vascular monitorings and lung lymph fistulas. We measured systemic artery pressure (Psa), pulmonary artery pressure (Ppa), and left atrial pressure (Pla) continuously. Cardiac output (CO) was measured every 30 min. Lung lymph flow (Qlym) was collected every 15 min. After baseline measurements, two HES solutions were infused over 2 h, respectively. Experiment 1 (n=6): low molecular weight HES (MW 70\u2003000, substitution ratio 0.5\u20130.55), Experiment 2 (n=5): high molecular weight HES (MW 450\u2003000, substitution ratio 0.7).<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Both low and high molecular HES behaved similarly as a volume expander, increasing Psa, CO, Pla and Ppa, and decreasing hematocrit. In addition, the actual oncotic pressure gradient (plasma \u2013 lymph) was widened after the start of either low or high molecular HES, but the value for high molecular HES was significantly higher than that for low molecular HES. Qlym of low molecular HES rose significantly from the baseline and the percent increase in Qlym for low molecular HES was significantly higher than that for high molecular HES.<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> These data suggest that low molecular HES is as useful a plasma substitute as high molecular HES, but may increase lung fluid filtration in the overinfused state.<\/jats:p>","DOI":"10.1034\/j.1399-6576.2000.440307.x","type":"journal-article","created":{"date-parts":[[2003,3,10]],"date-time":"2003-03-10T09:41:25Z","timestamp":1047289285000},"page":"255-260","source":"Crossref","is-referenced-by-count":1,"title":["Lung lymph response to overinfusion with hydroxyethyl starch in sheep"],"prefix":"10.1111","volume":"44","author":[{"given":"T.","family":"Koizumi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Kaneki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Yamamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"GE.","family":"Ri\u2010Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"Drome","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Kubo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Shibamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2001,12,24]]},"reference":[{"key":"e_1_2_5_2_2","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1983.01390070016004"},{"key":"e_1_2_5_3_2","first-page":"259","article-title":"Effect of an equal volume replacement with 500 ml 6% hydroxyethyl starch on the blood and plasma volume of healthy volunteers.","volume":"12","author":"Mortelmans Y","year":"1995","journal-title":"Eur J Anaesthesiol"},{"key":"e_1_2_5_4_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1995.tb04049.x"},{"key":"e_1_2_5_5_2","first-page":"3","article-title":"Human albumin and colloid fluid replacement: their use in general surgery.","volume":"46","author":"Ivens FCD","year":"1995","journal-title":"Acta Anaesth Belg"},{"key":"e_1_2_5_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0888-6296(88)80004-8"},{"key":"e_1_2_5_7_2","first-page":"494","article-title":"Pharmacokinetic parameters as criteria for the clinical use of hydroxyethyl starch preparations.","volume":"41","author":"Weidler B","year":"1991","journal-title":"Drug Res"},{"key":"e_1_2_5_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(77)91953-5"},{"key":"e_1_2_5_9_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1985.25485273815.x"},{"key":"e_1_2_5_10_2","doi-asserted-by":"publisher","DOI":"10.1046\/j.1537-2995.1988.28388219155.x"},{"key":"e_1_2_5_11_2","first-page":"H1536","article-title":"Effects of intravenous pentafraction on lung and soft tissue liquid exchange in hypoproteinemic sheep.","volume":"265","author":"Conhaim RL","year":"1993","journal-title":"Am J Physiol"},{"key":"e_1_2_5_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6060(05)80211-9"},{"key":"e_1_2_5_13_2","doi-asserted-by":"crossref","first-page":"1507","DOI":"10.1152\/jappl.1994.77.3.1507","article-title":"Compared with crystalloid, colloid therapy slows progression of extrapulmonary tissue injury in septic sheep.","volume":"77","author":"Morisaki H","year":"1994","journal-title":"J Appl Physiol"},{"key":"e_1_2_5_14_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm\/148.4_Pt_1.852"},{"key":"e_1_2_5_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-197903000-00007"},{"key":"e_1_2_5_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0034-5687(97)00025-X"},{"key":"e_1_2_5_17_2","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1152\/physrev.1974.54.3.678","article-title":"Pulmonary edema.","volume":"54","author":"Staub NC","year":"1974","journal-title":"Physiol Rev"},{"key":"e_1_2_5_18_2","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1152\/ajplegacy.1967.213.4.910","article-title":"Pulmonary capillary pressure and filtration coefficient in the isolated perfused lung.","volume":"213","author":"Gaar KA","year":"1967","journal-title":"Am J Physiol"},{"key":"e_1_2_5_19_2","first-page":"620","article-title":"The short\u2010term effects of increasing plasma colloid osmotic pressure in patients with noncardiac pulmonary edema.","volume":"93","author":"Sibbald WJ","year":"1982","journal-title":"Surgery"},{"key":"e_1_2_5_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-198311000-00001"},{"key":"e_1_2_5_21_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.82.4.433"},{"key":"e_1_2_5_22_2","unstructured":"KanekiT KoizumiT YamamotoH KuboK.Effects of resuscitation with hydroxyethyl starch (HES) on pulmonary hemodynamics and lung lymph balance in hemorrhagic sheep: comparative study of low and high molecular HES.Submitted."},{"key":"e_1_2_5_23_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.37.3.271"},{"key":"e_1_2_5_24_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.7.4.649"},{"key":"e_1_2_5_25_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.RES.67.4.852"},{"key":"e_1_2_5_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0034-5687(87)80009-9"},{"key":"e_1_2_5_27_2","first-page":"529","article-title":"Effect of dextran +70 on increased microvascular fluid and protein flux after thermal injury.","volume":"9","author":"Kramer GC","year":"1982","journal-title":"Circ Shock"}],"container-title":["Acta Anaesthesiologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1034%2Fj.1399-6576.2000.440307.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1034%2Fj.1399-6576.2000.440307.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1034\/j.1399-6576.2000.440307.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,28]],"date-time":"2023-09-28T00:09:50Z","timestamp":1695859790000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1034\/j.1399-6576.2000.440307.x"}},"subtitle":["Comparative studies of high and low molecular weight compounds"],"short-title":[],"issued":{"date-parts":[[2000,3]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2000,3]]}},"alternative-id":["10.1034\/j.1399-6576.2000.440307.x"],"URL":"https:\/\/doi.org\/10.1034\/j.1399-6576.2000.440307.x","archive":["Portico"],"relation":{},"ISSN":["0001-5172","1399-6576"],"issn-type":[{"value":"0001-5172","type":"print"},{"value":"1399-6576","type":"electronic"}],"subject":[],"published":{"date-parts":[[2000,3]]}}}