{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T04:23:26Z","timestamp":1781238206447,"version":"3.54.1"},"reference-count":14,"publisher":"Wiley","issue":"3","license":[{"start":{"date-parts":[[2002,1,15]],"date-time":"2002-01-15T00:00:00Z","timestamp":1011052800000},"content-version":"vor","delay-in-days":228,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Ophthalmologica Scandinavica"],"published-print":{"date-parts":[[2001,6]]},"abstract":"<jats:p><jats:bold>ABSTRACT.<\/jats:bold><jats:bold> Purpose:<\/jats:bold> To compare 24\u2010hour diurnal intraocular pressure (IOP) measurements obtained using the Ocuton\u2010S applanation self tonometer and the Goldmann tonometer.<\/jats:p><jats:p><jats:bold>Methods:<\/jats:bold> 24\u2010hour diurnal IOP curves were obtained on 14 eyes of 7 trained patients suffering from medically controlled primary open angle glaucoma. IOP was measured every third hour starting at 9 a.m. with a calibrated Goldmann tonometer; one week later, a similar set of measurements was obtained with Ocuton\u2010S self tonometry by the patients. One week later still, ultrasound corneal pachymetry was performed at the same hours.<\/jats:p><jats:p><jats:bold>Results:<\/jats:bold> Overall IOP (24\u2010hour mean) did not differ significantly between the different measuring techniques (ANOVA, p=0.74), but the IOP differed in a statistically significant manner around the clock (ANOVA, p=0.00006). The mean Goldmann tonometric readings were up to 2.8 mmHg lower than the Ocuton\u2010S values during the daytime (9 a.m. to 9 p.m.), however, during the night (12 midnight to 6 a.m.) mean IOP measured with Goldmann tonometry was 2.2 to 3.3 mmHg higher than the corresponding average of the self tonometry readings. There was a statistically significant interaction between the type of tonometry and the time of the measurement (p=0.0007). Central corneal thickness (CCT) showed a significant change during the 24\u2010hour period (p=0.000001).<\/jats:p><jats:p><jats:bold>Conclusion:<\/jats:bold> IOP shows a different diurnal curve when measured with the Goldmann tonometer and with the Ocuton\u2010S applanation self tonometer. The instruments\u2019 readings might be influenced in different ways by the diurnal changes of the corneal thickness. Since Ocuton\u2010S self tonometry underestimates the IOP in the early morning period, a careful evaluation is necessary when nocturnal and early morning IOP elevation is investigated with this technique.<\/jats:p>","DOI":"10.1034\/j.1600-0420.2001.790317.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T03:17:52Z","timestamp":1047352672000},"page":"294-297","source":"Crossref","is-referenced-by-count":22,"title":["Ocuton\u2010S self tonometry vs. Goldmann tonometry; a diurnal comparison study"],"prefix":"10.1111","volume":"79","author":[{"given":"P\u00e9ter","family":"K\u00f3thy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P\u00e9ter","family":"Vargha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00e1bor","family":"Holl\u00f3","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2002,1,15]]},"reference":[{"key":"e_1_2_6_2_1","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-200004000-00002"},{"key":"e_1_2_6_3_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0420.1998.tb00868.x"},{"key":"e_1_2_6_4_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.76.5.280"},{"key":"e_1_2_6_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(98)91029-6"},{"key":"e_1_2_6_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6257(00)00110-7"},{"key":"e_1_2_6_7_1","first-page":"304","article-title":"Klinische und experimentelle Ergebnisse mit einem neuen vollautomatischen Selbsttonometer.","volume":"88","author":"Draeger J","year":"1999","journal-title":"Fortsch Ophthalmol"},{"key":"e_1_2_6_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/BF03164403"},{"key":"e_1_2_6_9_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.1975.tb01784.x"},{"key":"e_1_2_6_10_1","first-page":"299","article-title":"Self\u2010tonometry: technical aspects and clinical application. Internat","volume":"16","author":"Groenhoff S","year":"1992","journal-title":"Ophthalmol"},{"key":"e_1_2_6_11_1","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.80.12.1068"},{"key":"e_1_2_6_12_1","first-page":"2707","article-title":"Nocturnal elevation of intraocular pressure in young adults.","volume":"39","author":"Liu JHK","year":"1998","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_13_1","first-page":"2912","article-title":"Twenty\u2010four\u2010hour pattern of intraocular pressure in the ageing population.","volume":"40","author":"Liu JHK","year":"1999","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_2_6_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s004170050302"},{"key":"e_1_2_6_15_1","doi-asserted-by":"publisher","DOI":"10.1097\/00061198-199300220-00010"}],"container-title":["Acta Ophthalmologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1034%2Fj.1600-0420.2001.790317.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1034%2Fj.1600-0420.2001.790317.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1034\/j.1600-0420.2001.790317.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,15]],"date-time":"2023-10-15T14:47:39Z","timestamp":1697381259000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1034\/j.1600-0420.2001.790317.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,6]]},"references-count":14,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2001,6]]}},"alternative-id":["10.1034\/j.1600-0420.2001.790317.x"],"URL":"https:\/\/doi.org\/10.1034\/j.1600-0420.2001.790317.x","archive":["Portico"],"relation":{},"ISSN":["1395-3907","1600-0420"],"issn-type":[{"value":"1395-3907","type":"print"},{"value":"1600-0420","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,6]]}}}