{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T03:22:36Z","timestamp":1772767356341,"version":"3.50.1"},"reference-count":17,"publisher":"Wiley","issue":"5","license":[{"start":{"date-parts":[[2008,7,7]],"date-time":"2008-07-07T00:00:00Z","timestamp":1215388800000},"content-version":"vor","delay-in-days":2471,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Oral Implants Res"],"published-print":{"date-parts":[[2001,10]]},"abstract":"<jats:p><jats:bold>Abstract:<\/jats:bold> For several radiological examinations, a clinician can select between conventional and spiral computed tomography. Using both techniques, this study aimed at evaluating the difference in absorbed doses when examining a single lateral jaw segment in a human cadaver head and Rando phantom. The present study involved the placement of thermoluminescent dosimeter (TLD) chips (GR\u2010200) in the thyroid gland, and bilaterally, in the parotid and submandibular glands and the lenses of the eyes in both a human cadaver and a Rando phantom at corresponding locations. Consecutive conventional spiral tomographic examinations were carried out in both the left upper and lower premolar area, using a Cranex TOME<jats:sup>\u00ae<\/jats:sup> multifunctional unit. Each examination consisted of 4 slices with a 2 mm slice thickness and exposure parameters of 57 kV, 56 seconds and 1.6\u20132.0 mA. Regarding spiral computed tomography (CT), a Somatom Plus S<jats:sup>\u00ae<\/jats:sup> scanner (Siemens, Erlangen, Germany), with a slice thickness of 1 mm with settings at 120 kV and 165 mA, was used on both phantoms and separately in the upper and lower jaw. With conventional tomography, the findings of the present study showed that the parotid and submandibular glands on the side near the X\u2010ray tube received the highest dose, both for the cadaver head (doses ranging from 0.5 to 1.3 mGy) and the phantom (doses ranging from 0.6 to 2.6 mGy). For CT of the upper jaw, the highest doses were delivered to the parotid glands with an average absorbed dose of 9.2 and 10.6 mGy for the cadaver head and phantom, respectively. The submandibular glands received the highest doses during CT examination of the lower jaw with an average of 7.8 and 12.9 mGy for the cadaver head and phantom, respectively. It appears from the present investigation that if small edentulous regions are examined, radiation doses during conventional tomography remain much lower than during CT imaging. However, when multiple tomographic cuts are required, a spiral CT examination can replace a series of conventional examinations, especially in cases such as the rehabilitation of an edentulous upper jaw or a more complex surgery.<\/jats:p>","DOI":"10.1034\/j.1600-0501.2001.120507.x","type":"journal-article","created":{"date-parts":[[2003,3,11]],"date-time":"2003-03-11T12:38:05Z","timestamp":1047386285000},"page":"473-478","source":"Crossref","is-referenced-by-count":20,"title":["Absorbed doses from spiral CT and conventional spiral tomography: a phantom vs. cadaver study"],"prefix":"10.1111","volume":"12","author":[{"given":"C.","family":"Bou Serhal","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Jacobs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"F.","family":"Gijbels","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Quirynen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Van Steenberghe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Bosmans","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Hermans","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2008,7,7]]},"reference":[{"key":"e_1_2_7_2_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2000.011003242.x"},{"key":"e_1_2_7_3_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.2001.012001085.x"},{"key":"e_1_2_7_4_1","article-title":"Localisation of the mandibular canal using conventional spiral tomography: a human cadaver study","author":"Bou Serhal C.","year":"2001","journal-title":"Clinical Oral Implants Research"},{"key":"e_1_2_7_5_1","first-page":"156","article-title":"Radiation absorbed from dental implant radiography: a comparison of linear tomography, CT scan, and panoramic and intraoral techniques","volume":"16","author":"Clark D.E.","year":"1990","journal-title":"Journal of Oral Implantology"},{"key":"e_1_2_7_6_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0722.1996.tb00133.x"},{"key":"e_1_2_7_7_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0722.1997.tb00190.x"},{"key":"e_1_2_7_8_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.22.1.8508935"},{"key":"e_1_2_7_9_1","doi-asserted-by":"publisher","DOI":"10.1259\/dmfr.24.1.8593910"},{"key":"e_1_2_7_10_1","first-page":"436","article-title":"A multimodal unit for comprehensive dento\u2010maxillofacial radiography","volume":"20","author":"Gr\u00f6ndahl K.","year":"1993","journal-title":"Dental Update"},{"key":"e_1_2_7_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-80424-3"},{"key":"e_1_2_7_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/0030-4220(92)90334-M"},{"key":"e_1_2_7_13_1","first-page":"119","volume-title":"Advances in Maxillofacial Imaging","author":"Kim K.D.","year":"1997"},{"key":"e_1_2_7_14_1","first-page":"327","article-title":"Location of the mandibular canal: comparison of macroscopic findings, conventional radiography, and computed tomography","volume":"4","author":"Klinge B.","year":"1989","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_7_15_1","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0501.1992.030207.x"},{"key":"e_1_2_7_16_1","first-page":"384","article-title":"The CT scan standard reconstruction technique for reliable jaw bone volume determination","volume":"5","author":"Quirynen M.","year":"1990","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_7_17_1","first-page":"455","article-title":"A comparison of the accuracy of periapical, and computerised tomographic radiographs in locating the mandibular canal","volume":"9","author":"Sonick M.","year":"1994","journal-title":"International Journal of Oral and Maxillofacial Implants"},{"key":"e_1_2_7_18_1","first-page":"407","volume-title":"Advances in Maxillofacial Imaging","author":"Velders X.L.","year":"1997"}],"container-title":["Clinical Oral Implants Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1034%2Fj.1600-0501.2001.120507.x","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1034%2Fj.1600-0501.2001.120507.x","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1034\/j.1600-0501.2001.120507.x","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T22:15:43Z","timestamp":1697580943000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1034\/j.1600-0501.2001.120507.x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,10]]},"references-count":17,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2001,10]]}},"alternative-id":["10.1034\/j.1600-0501.2001.120507.x"],"URL":"https:\/\/doi.org\/10.1034\/j.1600-0501.2001.120507.x","archive":["Portico"],"relation":{},"ISSN":["0905-7161","1600-0501"],"issn-type":[{"value":"0905-7161","type":"print"},{"value":"1600-0501","type":"electronic"}],"subject":[],"published":{"date-parts":[[2001,10]]}}}