{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T23:58:43Z","timestamp":1774396723533,"version":"3.50.1"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,6,6]],"date-time":"2019-06-06T00:00:00Z","timestamp":1559779200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,6,6]],"date-time":"2019-06-06T00:00:00Z","timestamp":1559779200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Mobile technologies, such as smart phone applications, wearables, ingestibles, and implantables, are increasingly used in clinical research to capture study endpoints. On behalf of the Clinical Trials Transformation Initiative, we aimed to conduct a systematic scoping review and compile a database summarizing pilot studies addressing mobile technology sensor performance, algorithm development, software performance, and\/or operational feasibility, in order to provide a resource for guiding decisions about which technology is most suitable for a particular trial. Our systematic search identified 275 publications meeting inclusion criteria. From these papers, we extracted data including the medical condition, concept of interest captured by the mobile technology, outcomes captured by the digital measurement, and details regarding the sensors, algorithms, and study sample. Sixty-seven percent of the technologies identified were wearable sensors, with the remainder including tablets, smartphones, implanted sensors, and cameras. We noted substantial variability in terms of reporting completeness and terminology used. The data have been compiled into an online database maintained by the Clinical Trials Transformation Initiative that can be filtered and searched electronically, enabling a user to find information most relevant to their work. Our long-term goal is to maintain and update the online database, in order to promote standardization of methods and reporting, encourage collaboration, and avoid redundant studies, thereby contributing to the design and implementation of efficient, high-quality trials.<\/jats:p>","DOI":"10.1038\/s41746-019-0125-x","type":"journal-article","created":{"date-parts":[[2019,6,6]],"date-time":"2019-06-06T10:02:39Z","timestamp":1559815359000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":57,"title":["A systematic review of feasibility studies promoting the use of mobile technologies in clinical research"],"prefix":"10.1038","volume":"2","author":[{"given":"Jessie P.","family":"Bakker","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jennifer C.","family":"Goldsack","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Clarke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5379-3540","authenticated-orcid":false,"given":"Andrea","family":"Coravos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cynthia","family":"Geoghegan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4049-9291","authenticated-orcid":false,"given":"Alan","family":"Godfrey","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6520-8369","authenticated-orcid":false,"given":"Matthew G.","family":"Heasley","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel R.","family":"Karlin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christine","family":"Manta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Barry","family":"Peterson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3121-2837","authenticated-orcid":false,"given":"Ernesto","family":"Ramirez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nirav","family":"Sheth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonia","family":"Bruno","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emilia","family":"Bullis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kirsten","family":"Wareham","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3391-2623","authenticated-orcid":false,"given":"Noah","family":"Zimmerman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annemarie","family":"Forrest","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William A.","family":"Wood","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,6,6]]},"reference":[{"key":"125_CR1","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1159\/000486347","volume":"2","author":"B Perry","year":"2018","unstructured":"Perry, B. et al. Use of mobile devices to measure outcomes in clinical research, 2010\u20132016: a systematic literature review. Digit. Biomark. 2, 11\u201330 (2018).","journal-title":"Digit. Biomark."},{"key":"125_CR2","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1038\/nrd.2017.153","volume":"16","author":"SP Arneri\u0107","year":"2017","unstructured":"Arneri\u0107, S. P. et al. Biometric monitoring devices for assessing end points in clinical trials: developing an ecosystem. Nat. Rev. Drug Discov. 16, 736 (2017).","journal-title":"Nat. Rev. Drug Discov."},{"key":"125_CR3","doi-asserted-by":"publisher","first-page":"R358","DOI":"10.1152\/ajpregu.00349.2016","volume":"312","author":"SP Wright","year":"2017","unstructured":"Wright, S. P., Brown, T. S. H., Collier, S. R. & Sandberg, K. How consumer physical activity monitors could transform human physiology research. Am. J. Physiol.-Regul., Integr. Comp. Physiol. 312, R358\u2013R367 (2017).","journal-title":"Am. J. Physiol.-Regul., Integr. Comp. Physiol."},{"key":"125_CR4","doi-asserted-by":"publisher","first-page":"1020.1024","DOI":"10.1096\/fj.201700043R","volume":"31","author":"SP Wright","year":"2017","unstructured":"Wright, S. P., Collier, S. R., Brown, T. S. & Sandberg, K. An analysis of how consumer physical activity monitors are used in biomedical research. FASEB J. 31, 1020.1024\u20131020.1024 (2017).","journal-title":"FASEB J."},{"key":"125_CR5","doi-asserted-by":"publisher","first-page":"17472","DOI":"10.3390\/s131217472","volume":"13","author":"H Banaee","year":"2013","unstructured":"Banaee, H., Ahmed, M. U. & Loutfi, A. Data mining for wearable sensors in health monitoring systems: a review of recent trends and challenges. Sens. (Basel, Switz.) 13, 17472\u201317500 (2013).","journal-title":"Sens. (Basel, Switz.)"},{"key":"125_CR6","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1159\/000492396","volume":"2","author":"AB Cohen","year":"2018","unstructured":"Cohen, A. B. & Mathews, S. C. The digital outcome measure. Digit. Biomark. 2, 94\u2013105 (2018).","journal-title":"Digit. Biomark."},{"key":"125_CR7","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1002\/cpt.966","volume":"104","author":"ES Izmailova","year":"2018","unstructured":"Izmailova, E. S., Wagner, J. A. & Perakslis, E. D. Wearable devices in clinical trials: hype and hypothesis. Clin. Pharmacol. Ther. 104, 42\u201352 (2018).","journal-title":"Clin. Pharmacol. Ther."},{"key":"125_CR8","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0138095","volume":"10","author":"HH Dodge","year":"2015","unstructured":"Dodge, H. H. et al. Use of high-frequency in-home monitoring data may reduce sample sizes needed in clinical trials. PLoS ONE 10, e0138095 (2015).","journal-title":"PLoS ONE"},{"key":"125_CR9","doi-asserted-by":"publisher","DOI":"10.1186\/s13063-015-0776-0","volume":"16","author":"S Treweek","year":"2015","unstructured":"Treweek, S. et al. Making randomised trials more efficient: report of the first meeting to discuss the Trial Forge platform. Trials 16, 261 (2015).","journal-title":"Trials"},{"key":"125_CR10","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/S0140-6736(13)62227-8","volume":"383","author":"JP Ioannidis","year":"2014","unstructured":"Ioannidis, J. P. et al. Increasing value and reducing waste in research design, conduct, and analysis. Lancet (Lond., Engl.) 383, 166\u2013175 (2014).","journal-title":"Lancet (Lond., Engl.)"},{"key":"125_CR11","doi-asserted-by":"publisher","first-page":"161","DOI":"10.2217\/pme.11.7","volume":"8","author":"EO Lillie","year":"2011","unstructured":"Lillie, E. O. et al. The n-of-1 clinical trial: the ultimate strategy for individualizing medicine? Pers. Med. 8, 161\u2013173 (2011).","journal-title":"Pers. Med."},{"key":"125_CR12","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.1093\/jamia\/ocy067","volume":"25","author":"W Speier","year":"2018","unstructured":"Speier, W. et al. Evaluating utility and compliance in a patient-based eHealth study using continuous-time heart rate and activity trackers. J. Am. Med. Inform. Assoc. 25, 1386\u20131391 (2018).","journal-title":"J. Am. Med. Inform. Assoc."},{"key":"125_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/JTEHM.2018.2866162","volume":"6","author":"AP Dhawan","year":"2018","unstructured":"Dhawan, A. P. Editorial trends and challenges in translation of point-of-care technologies in healthcare. IEEE J. Transl. Eng. Health Med. 6, 1\u20138 (2018).","journal-title":"IEEE J. Transl. Eng. Health Med."},{"key":"125_CR14","doi-asserted-by":"publisher","first-page":"130","DOI":"10.3390\/s17010130","volume":"17","author":"S Majumder","year":"2017","unstructured":"Majumder, S., Mondal, T. & Deen, M. J. Wearable sensors for remote health monitoring. Sensors (Basel) 17, 130 (2017).","journal-title":"Sensors (Basel)"},{"key":"125_CR15","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1136\/bmj.328.7430.22","volume":"328","author":"HP Soares","year":"2004","unstructured":"Soares, H. P. et al. Bad reporting does not mean bad methods for randomised trials: observational study of randomised controlled trials performed by the Radiation Therapy Oncology Group. BMJ (Clin. Res.) 328, 22\u201324 (2004).","journal-title":"BMJ (Clin. Res.)"},{"key":"125_CR16","doi-asserted-by":"publisher","DOI":"10.1186\/1472-6947-7-16","volume":"7","author":"C Schardt","year":"2007","unstructured":"Schardt, C., Adams, M. B., Owens, T., Keitz, S. & Fontelo, P. Utilization of the PICO framework to improve searching PubMed for clinical questions. BMC Med. Inform. Decis. Mak. 7, 16 (2007).","journal-title":"BMC Med. Inform. Decis. Mak."}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0125-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0125-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0125-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T18:28:17Z","timestamp":1671301697000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0125-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,6]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["125"],"URL":"https:\/\/doi.org\/10.1038\/s41746-019-0125-x","relation":{},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,6]]},"assertion":[{"value":"5 February 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"J.B.: full time employee at Philips; J.G.: full time employee at monARC Bionetworks; M.C.: A.C.: full time employee and shareholder at Elektra Labs; M.H.: full time employee and shareholder at GlaxoSmithKline; D.K.: full time employee at HealthMode; E.R.: full time employee at Evidation Health; E.B.: full time employee at 23andMe, Inc.; N.Z.: scientific advisor for Picnic Health; W.W.: research funding from Genentech, Pfizer; Scientific advisor for Koneksa Health. M.C., A.F., C.G., A.G., C.M., B.P., N.S., A.B., and K.W. declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"47"}}