{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T19:18:44Z","timestamp":1777058324383,"version":"3.51.4"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,12,20]],"date-time":"2019-12-20T00:00:00Z","timestamp":1576800000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,12,20]],"date-time":"2019-12-20T00:00:00Z","timestamp":1576800000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000002","name":"U.S. Department of Health & Human Services | National Institutes of Health","doi-asserted-by":"publisher","award":["T32GM008152"],"award-info":[{"award-number":["T32GM008152"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Polysomnography (PSG) is the current gold standard in high-resolution sleep monitoring; however, this method is obtrusive, expensive, and time-consuming. Conversely, commercially available wrist monitors such as ActiWatch can monitor sleep for multiple days and at low cost, but often overestimate sleep and cannot differentiate between sleep stages, such as rapid eye movement (REM) and non-REM. Wireless wearable sensors are a promising alternative for their portability and access to high-resolution data for customizable analytics. We present a multimodal sensor system measuring hand acceleration, electrocardiography, and distal skin temperature that outperforms the ActiWatch, detecting wake and sleep with a recall of 74.4% and 90.0%, respectively, as well as wake, non-REM, and REM with recall of 73.3%, 59.0%, and 56.0%, respectively. This approach will enable clinicians and researchers to more easily, accurately, and inexpensively assess long-term sleep patterns, diagnose sleep disorders, and monitor risk factors for disease in both laboratory and home settings.<\/jats:p>","DOI":"10.1038\/s41746-019-0210-1","type":"journal-article","created":{"date-parts":[[2019,12,20]],"date-time":"2019-12-20T11:03:50Z","timestamp":1576839830000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":86,"title":["Automating sleep stage classification using wireless, wearable sensors"],"prefix":"10.1038","volume":"2","author":[{"given":"Alexander J.","family":"Boe","sequence":"first","affiliation":[]},{"given":"Lori L.","family":"McGee Koch","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8069-365X","authenticated-orcid":false,"given":"Megan K.","family":"O\u2019Brien","sequence":"additional","affiliation":[]},{"given":"Nicholas","family":"Shawen","sequence":"additional","affiliation":[]},{"given":"John A.","family":"Rogers","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7203-4520","authenticated-orcid":false,"given":"Richard L.","family":"Lieber","sequence":"additional","affiliation":[]},{"given":"Kathryn J.","family":"Reid","sequence":"additional","affiliation":[]},{"given":"Phyllis C.","family":"Zee","sequence":"additional","affiliation":[]},{"given":"Arun","family":"Jayaraman","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,12,20]]},"reference":[{"key":"210_CR1","doi-asserted-by":"publisher","first-page":"5","DOI":"10.2337\/diaspect.29.1.5","volume":"29","author":"DW Carley","year":"2016","unstructured":"Carley, D. W. & Farabi, S. S. Physiology of sleep. Diabetes Spectr. 29, 5\u20139 (2016).","journal-title":"Diabetes Spectr."},{"key":"210_CR2","doi-asserted-by":"publisher","first-page":"e106","DOI":"10.1371\/journal.pbio.0060106","volume":"6","author":"E Mignot","year":"2008","unstructured":"Mignot, E. Why we sleep: the temporal organization of recovery. PLoS Biol. 6, e106 (2008).","journal-title":"PLoS Biol."},{"key":"210_CR3","doi-asserted-by":"publisher","first-page":"711","DOI":"10.3345\/kjp.2007.50.8.711","volume":"50","author":"KY Chae","year":"2007","unstructured":"Chae, K. Y. Physiology of sleep. Korean J. Pediatrics 50, 711\u2013717 (2007).","journal-title":"Korean J. Pediatrics"},{"key":"210_CR4","doi-asserted-by":"publisher","first-page":"151","DOI":"10.2147\/NSS.S134864","volume":"9","author":"G Medic","year":"2017","unstructured":"Medic, G., Wille, M. & Hemels, M. E. Short-and long-term health consequences of sleep disruption. Nat. Sci. Sleep. 9, 151 (2017).","journal-title":"Nat. Sci. Sleep."},{"key":"210_CR5","doi-asserted-by":"publisher","first-page":"1027","DOI":"10.1016\/j.socscimed.2010.05.041","volume":"71","author":"OM Buxton","year":"2010","unstructured":"Buxton, O. M. & Marcelli, E. Short and long sleep are positively associated with obesity, diabetes, hypertension, and cardiovascular disease among adults in the United States. MSoc. Sci. Med. 71, 1027\u20131036 (2010).","journal-title":"MSoc. Sci. Med."},{"key":"210_CR6","unstructured":"Iber, C., Ancoli-Israel, S., Chesson, A. L. Jr. & Quan, S. F. The AASM Manual for the Scoring of Sleep and Associated Events: Rules Terminology and Technical Specifications, 1st edn. (American Academy of Sleep Medicine, Westchester, 2007)."},{"key":"210_CR7","doi-asserted-by":"publisher","first-page":"496","DOI":"10.7326\/0003-4819-130-6-199903160-00006","volume":"130","author":"RD Chervin","year":"1999","unstructured":"Chervin, R. D., Murman, D. L., Malow, B. A. & Totten, V. Cost-utility of three approaches to the diagnosis of sleep apnea: polysomnography, home testing, and empirical therapy. Ann. Intern. Med. 130, 496\u2013505 (1999).","journal-title":"Ann. Intern. Med."},{"key":"210_CR8","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1093\/sleep\/26.1.81","volume":"26","author":"L De Souza","year":"2003","unstructured":"De Souza, L. et al. Further validation of actigraphy for sleep studies. Sleep 26, 81\u201385 (2003).","journal-title":"Sleep"},{"key":"210_CR9","unstructured":"Oakley, N. Validation with polysomnography of the Sleepwatch sleep\/wake scoring algorithm used by the Actiwatch activity monitoring system. Technical Report to Mini Mitter Co., Inc. (1997)."},{"key":"210_CR10","doi-asserted-by":"crossref","first-page":"336","DOI":"10.5664\/jcsm.27874","volume":"6","author":"AR Weiss","year":"2010","unstructured":"Weiss, A. R., Johnson, N. L., Berger, N. A. & Redline, S. Validity of activity-based devices to estimate sleep. J. Clin. Sleep. Med. 6, 336\u2013342 (2010).","journal-title":"J. Clin. Sleep. Med."},{"key":"210_CR11","doi-asserted-by":"publisher","first-page":"1747","DOI":"10.5665\/sleep.3142","volume":"36","author":"M Marino","year":"2013","unstructured":"Marino, M. et al. Measuring sleep: accuracy, sensitivity, and specificity of wrist actigraphy compared to polysomnography. Sleep 36, 1747\u20131755 (2013).","journal-title":"Sleep"},{"key":"210_CR12","doi-asserted-by":"publisher","first-page":"13","DOI":"10.2147\/NSS.S151085","volume":"10","author":"M Quante","year":"2018","unstructured":"Quante, M. et al. Actigraphy-based sleep estimation in adolescents and adults: a comparison with polysomnography using two scoring algorithms. Nat. Sci. Sleep 10, 13 (2018).","journal-title":"Nat. Sci. Sleep"},{"key":"210_CR13","doi-asserted-by":"crossref","first-page":"217","DOI":"10.5664\/jcsm.2482","volume":"9","author":"DM Taibi","year":"2013","unstructured":"Taibi, D. M., Landis, C. A. & Vitiello, M. V. Concordance of polysomnographic and actigraphic measurement of sleep and wake in older women with insomnia. J. Clin. Sleep Med. 9, 217\u2013225 (2013).","journal-title":"J. Clin. Sleep Med."},{"key":"210_CR14","doi-asserted-by":"publisher","first-page":"1209","DOI":"10.5664\/jcsm.7228","volume":"14","author":"MT Smith","year":"2018","unstructured":"Smith, M. T. et al. Use of actigraphy for the evaluation of sleep disorders and circadian rhythm sleep- wake disorders: an American Academy of Sleep Medicine systematic review, meta-analysis, and GRADE assessment. J. Clin. Sleep Med. 14, 1209\u20131230 (2018).","journal-title":"J. Clin. Sleep Med."},{"key":"210_CR15","doi-asserted-by":"crossref","unstructured":"Cortelli, P. and Lombardi, C. Sleep and autonomic nervous system dysfunction. In: Handbook of Clinical Neurophysiology: Clinical neurophysiology of sleep disorders, 6th edn, 343\u2013353 (Elsevier, 2005).","DOI":"10.1016\/S1567-4231(09)70054-1"},{"key":"210_CR16","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1046\/j.1365-2869.2001.00263.x","volume":"10","author":"J Trinder","year":"2001","unstructured":"Trinder, J. et al. Autonomic activity during human sleep as a function of time and sleep stage. J. Sleep Res. 10, 253\u2013264 (2001).","journal-title":"J. Sleep Res."},{"key":"210_CR17","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1056\/NEJM199302043280502","volume":"328","author":"VK Somers","year":"1993","unstructured":"Somers, V. K., Dyken, M. E., Mark, A. L. & Abboud, F. M. Sympathetic-nerve activity during sleep in normal subjects. N. Engl. J. Med. 328, 303\u2013307 (1993).","journal-title":"N. Engl. J. Med."},{"key":"210_CR18","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1056\/NEJM199302043280511","volume":"328","author":"G Mancia","year":"1993","unstructured":"Mancia, G. Autonomic modulation of the cardiovascular system during sleep. N. Engl. J. Med. 328, 347\u2013349 (1993).","journal-title":"N. Engl. J. Med."},{"key":"210_CR19","doi-asserted-by":"publisher","first-page":"624","DOI":"10.3389\/fphys.2017.00624","volume":"8","author":"M Cerri","year":"2017","unstructured":"Cerri, M., Luppi, M., Tupone, D., Zamboni, G. & Amici, R. REM sleep and endothermy: potential sites and mechanism of a reciprocal interference. Front. Physiol. 8, 624 (2017).","journal-title":"Front. Physiol."},{"key":"210_CR20","doi-asserted-by":"publisher","first-page":"s557","DOI":"10.2741\/1054","volume":"8","author":"PL Parmeggiani","year":"2003","unstructured":"Parmeggiani, P. L. Thermoregulation and sleep. Front. Biosci. 8, s557\u2013s567 (2003).","journal-title":"Front. Biosci."},{"key":"210_CR21","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1053\/smrv.2001.0177","volume":"6","author":"V Bach","year":"2002","unstructured":"Bach, V., Telliez, F. & Libert, J.-P. The interaction between sleep and thermoregulation in adults and neonates. Sleep Med. Rev. 6, 481\u2013492 (2002).","journal-title":"Sleep Med. Rev."},{"key":"210_CR22","doi-asserted-by":"publisher","first-page":"130","DOI":"10.3390\/s17010130","volume":"17","author":"S Majumder","year":"2017","unstructured":"Majumder, S., Mondal, T. & Deen, M. J. Wearable sensors for remote health monitoring. Sensors 17, 130 (2017).","journal-title":"Sensors"},{"key":"210_CR23","doi-asserted-by":"publisher","first-page":"4373","DOI":"10.1002\/adma.201504366","volume":"28","author":"Y Khan","year":"2016","unstructured":"Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A. & Arias, A. C. Monitoring of vital signs with flexible and wearable medical devices. Adv. Mater. 28, 4373\u20134395 (2016).","journal-title":"Adv. Mater."},{"key":"210_CR24","doi-asserted-by":"crossref","unstructured":"Lonini, L. et al. Wearable sensors for Parkinson\u2019s disease: which data are worth collecting for training symptom detection models. NPJ Digit. Med. 1, 64 (2018).","DOI":"10.1038\/s41746-018-0071-z"},{"key":"210_CR25","doi-asserted-by":"publisher","first-page":"e151","DOI":"10.2196\/mhealth.8201","volume":"5","author":"N Shawen","year":"2017","unstructured":"Shawen, N. et al. Fall detection in individuals with lower limb amputations using mobile phones: machine learning enhances robustness for real-world applications. JMIR mHealth uHealth 5, e151 (2017).","journal-title":"JMIR mHealth uHealth"},{"key":"210_CR26","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1159\/000085205","volume":"51","author":"P Anderer","year":"2005","unstructured":"Anderer, P. et al. An E-health solution for automatic sleep classification according to Rechtschaffen and Kales: validation study of the Somnolyzer 24\u00d7 7 utilizing the Siesta database. Neuropsychobiology 51, 115\u2013133 (2005).","journal-title":"Neuropsychobiology"},{"key":"210_CR27","doi-asserted-by":"crossref","unstructured":"Ebrahimi, F., Mikaeili, M., Estrada, E. & Nazeran, H. Automatic sleep stage classification based on EEG signals by using neural networks and wavelet packet coefficients. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2008, 1151\u20131154 (2008).","DOI":"10.1109\/IEMBS.2008.4649365"},{"key":"210_CR28","doi-asserted-by":"crossref","unstructured":"De Vicq, N., Robert, F., Penders, J., Gyselinckx, B. & Torfs, T. Wireless body area network for sleep staging in 2007 IEEE Biomedical Circuits and Systems Conference, 163\u2013166 (2007).","DOI":"10.1109\/BIOCAS.2007.4463334"},{"key":"210_CR29","doi-asserted-by":"publisher","first-page":"2027","DOI":"10.1088\/0967-3334\/36\/10\/2027","volume":"36","author":"P Fonseca","year":"2015","unstructured":"Fonseca, P. et al. Sleep stage classification with ECG and respiratory effort. Physiol. Meas. 36, 2027\u20132040 (2015).","journal-title":"Physiol. Meas."},{"key":"210_CR30","doi-asserted-by":"publisher","first-page":"1711","DOI":"10.1109\/TBME.2014.2301462","volume":"61","author":"A Domingues","year":"2014","unstructured":"Domingues, A., Paiva, T. & Sanches, J. M. Hypnogram and sleep parameter computation from activity and cardiovascular data. IEEE Trans. Biomed. Eng. 61, 1711\u20131719 (2014).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"210_CR31","doi-asserted-by":"publisher","first-page":"1968","DOI":"10.1088\/1361-6579\/aa9047","volume":"38","author":"Z Beattie","year":"2017","unstructured":"Beattie, Z. et al. Estimation of sleep stages in a healthy adult population from optical plethysmography and accelerometer signals. Physiol. Meas. 38, 1968 (2017).","journal-title":"Physiol. Meas."},{"key":"210_CR32","doi-asserted-by":"publisher","first-page":"336","DOI":"10.3389\/fnins.2019.00336","volume":"13","author":"EC Harding","year":"2019","unstructured":"Harding, E. C., Franks, N. P. & Wisden, W. The temperature dependence of sleep. Front. Neurosci. 13, 336 (2019).","journal-title":"Front. Neurosci."},{"key":"210_CR33","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1038\/43366","volume":"401","author":"K Krauchi","year":"1999","unstructured":"Krauchi, K., Cajochen, C., Weth, E. & Wirz-Justice, A. Warm feet promote the rapid onset of sleep. Nature 401, 36 (1999).","journal-title":"Nature"},{"key":"210_CR34","doi-asserted-by":"publisher","first-page":"R819","DOI":"10.1152\/ajpregu.1994.267.3.R819","volume":"267","author":"K Krauchi","year":"1994","unstructured":"Krauchi, K. & Wirz-Justice, A. Circadian rhythm of heat production, heart rate, and skin and core temperature under unmasking conditions in men. Am. J. Physiol. Regul. Integr. Comp. Physiol. 267, R819\u2013R829 (1994).","journal-title":"Am. J. Physiol. Regul. Integr. Comp. Physiol."},{"key":"210_CR35","doi-asserted-by":"publisher","first-page":"R741","DOI":"10.1152\/ajpregu.2000.278.3.R741","volume":"278","author":"K Krauchi","year":"2000","unstructured":"Krauchi, K., Cajochen, C., Werth, E. & Wirz-Justice, A. Functional link between distal vasodilation and sleep-onset latency? Am. J. Physiol. Regul, Integr. Comp. Physiol. 278, R741\u2013R748 (2000).","journal-title":"Am. J. Physiol. Regul, Integr. Comp. Physiol."},{"key":"210_CR36","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1152\/ajplegacy.1976.230.2.449","volume":"230","author":"MA Baker","year":"1976","unstructured":"Baker, M. A., Cronin, M. J. & Mountjoy, D. G. Variability of skin temperature in the waking monkey. Am. J. Physiol. 230, 449\u2013455 (1976).","journal-title":"Am. J. Physiol."},{"key":"210_CR37","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/S0305-0548(97)00074-9","volume":"25","author":"IS Markham","year":"1998","unstructured":"Markham, I. S. & Rakes, T. R. The effect of sample size and variability of data on the comparative performance of artificial neural networks and regression. Computers Oper. Res. 25, 251\u2013263 (1998).","journal-title":"Computers Oper. Res."},{"key":"210_CR38","doi-asserted-by":"crossref","first-page":"81","DOI":"10.5664\/jcsm.2350","volume":"9","author":"RS Rosenberg","year":"2013","unstructured":"Rosenberg, R. S. & Van Hout, S. The American Academy of sleep medicine inter-scorer reliability program: sleep stage scoring. J. Clin. Sleep. Med. 9, 81\u201387 (2013).","journal-title":"J. Clin. Sleep. Med."},{"key":"210_CR39","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.nbscr.2016.11.003","volume":"2","author":"SB Duss","year":"2017","unstructured":"Duss, S. B. et al. The role of sleep in recovery following ischemic stroke: a review of human and animal data. Neurobiol. Sleep. Circadian Rhythms 2, 94\u2013105 (2017).","journal-title":"Neurobiol. Sleep. Circadian Rhythms"},{"key":"210_CR40","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1001\/jamainternmed.2018.2669","volume":"178","author":"HM Wesselius","year":"2018","unstructured":"Wesselius, H. M. et al. Quality and quantity of sleep and factors associated with sleep disturbance in hospitalized patients. JAMA Intern. Med. 178, 1201\u20131208 (2018).","journal-title":"JAMA Intern. Med."},{"key":"210_CR41","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/0165-1781(89)90047-4","volume":"28","author":"DJ Buysse","year":"1989","unstructured":"Buysse, D. J., Reynolds, C. F. III, Monk, T. H., Berman, S. R. & Kupfer, D. J. The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res. 28, 193\u2013213 (1989).","journal-title":"Psychiatry Res."},{"key":"210_CR42","doi-asserted-by":"publisher","first-page":"781","DOI":"10.5665\/sleep.2648","volume":"36","author":"BH Te Lindert","year":"2013","unstructured":"Te Lindert, B. H. & Van Someren, E. J. Sleep estimates using microelectromechanical systems (MEMS). Sleep 36, 781\u2013789 (2013).","journal-title":"Sleep"},{"key":"210_CR43","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/j.compbiomed.2017.08.006","volume":"89","author":"M Aktaruzzaman","year":"2017","unstructured":"Aktaruzzaman, M. et al. Performance comparison between wrist and chest actigraphy in combination with heart rate variability for sleep classification. Computers Biol. Med. 89, 212\u2013221 (2017).","journal-title":"Computers Biol. Med."},{"key":"210_CR44","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1080\/15402002.2017.1300587","volume":"17","author":"M De Zambotti","year":"2019","unstructured":"De Zambotti, M., Rosas, L., Colrain, I. M. & Baker, F. C. The sleep of the ring: comparison of the OURA sleep tracker against polysomnography. Behav. Sleep Med. 17, 124\u2013136 (2019).","journal-title":"Behav. Sleep Med."},{"key":"210_CR45","doi-asserted-by":"publisher","first-page":"zsx097","DOI":"10.1093\/sleep\/zsx097","volume":"40","author":"P Fonseca","year":"2017","unstructured":"Fonseca, P. et al. Validation of photoplethysmography-based sleep staging compared with polysomnography in healthy middle-aged adults. Sleep 40, zsx097 (2017).","journal-title":"Sleep"},{"key":"210_CR46","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.5664\/jcsm.6802","volume":"13","author":"J Razjouyan","year":"2017","unstructured":"Razjouyan, J. et al. Improving sleep quality assessment using wearable sensors by including information from postural\/sleep position changes and body acceleration: a comparison of chest-worn sensors, wrist actigraphy, and polysomnography. J. Clin. Sleep. Med. 13, 1301\u20131310 (2017).","journal-title":"J. Clin. Sleep. Med."}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0210-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0210-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0210-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T18:36:56Z","timestamp":1671302216000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-019-0210-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,20]]},"references-count":46,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2019,12]]}},"alternative-id":["210"],"URL":"https:\/\/doi.org\/10.1038\/s41746-019-0210-1","relation":{},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12,20]]},"assertion":[{"value":"5 August 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"J.A.R. holds equity in the company MC10, Inc. that makes wearable sensors for medical applications. The remaining authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"131"}}