{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T08:13:54Z","timestamp":1770884034345,"version":"3.50.1"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,3,27]],"date-time":"2020-03-27T00:00:00Z","timestamp":1585267200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,3,27]],"date-time":"2020-03-27T00:00:00Z","timestamp":1585267200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Wearable sensors have the potential to enable measurement of sweat chloride outside the clinic. Here we assess the feasibility of mild exercise as an alternative to pilocarpine iontophoresis for sweat generation. The results from this proof-of-concept study suggest that mild exercise could be a feasible approach to obtain reliable measurements of sweat chloride concentration within 20\u201330\u2009min using a wearable sensor.<\/jats:p>","DOI":"10.1038\/s41746-020-0257-z","type":"journal-article","created":{"date-parts":[[2020,3,27]],"date-time":"2020-03-27T11:03:21Z","timestamp":1585307001000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":21,"title":["Out-of-clinic measurement of sweat chloride using a wearable sensor during low-intensity exercise"],"prefix":"10.1038","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8378-8187","authenticated-orcid":false,"given":"Dong-Hoon","family":"Choi","sequence":"first","affiliation":[]},{"given":"Grant B.","family":"Kitchen","sequence":"additional","affiliation":[]},{"given":"Mark T.","family":"Jennings","sequence":"additional","affiliation":[]},{"given":"Garry R.","family":"Cutting","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5417-0828","authenticated-orcid":false,"given":"Peter C.","family":"Searson","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,3,27]]},"reference":[{"key":"257_CR1","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.jpeds.2007.03.002","volume":"151","author":"VA LeGrys","year":"2007","unstructured":"LeGrys, V. A. et al. Diagnostic sweat testing: the Cystic Fibrosis Foundation guidelines. J. Pediatr. 151, 85\u201389 (2007).","journal-title":"J. Pediatr."},{"key":"257_CR2","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1016\/j.snb.2017.04.129","volume":"250","author":"DH Choi","year":"2017","unstructured":"Choi, D. H., Li, Y., Cutting, G. R. & Searson, P. C. A wearable potentiometric sensor with integrated salt bridge for sweat chloride measurement. Sens. Actuat. B 250, 673\u2013678 (2017).","journal-title":"Sens. Actuat. B"},{"key":"257_CR3","doi-asserted-by":"publisher","first-page":"e35","DOI":"10.1016\/j.jcf.2018.03.005","volume":"17","author":"DH Choi","year":"2018","unstructured":"Choi, D. H. et al. Sweat test for cystic fibrosis: wearable sweat sensor vs. standard laboratory test. J. Cyst. Fibros. 17, e35\u2013e38 (2018).","journal-title":"J. Cyst. Fibros."},{"key":"257_CR4","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.jcf.2011.08.003","volume":"11","author":"SM Paranjape","year":"2012","unstructured":"Paranjape, S. M. et al. Exercise improves lung function and habitual activity in children with cystic fibrosis. J. Cyst. Fibros. 11, 18\u201323 (2012).","journal-title":"J. Cyst. Fibros."},{"key":"257_CR5","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1378\/chest.10-1158","volume":"139","author":"TJ Dwyer","year":"2011","unstructured":"Dwyer, T. J., Alison, J. A., McKeough, Z. J., Daviskas, E. & Bye, P. T. P. Effects of exercise on respiratory flow and sputum properties in patients with cystic fibrosis. Chest 139, 870\u2013877 (2011).","journal-title":"Chest"},{"key":"257_CR6","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.physio.2010.12.004","volume":"97","author":"RW Bohannon","year":"2011","unstructured":"Bohannon, R. W. & Williams Andrews, A. Normal walking speed: a descriptive meta-analysis. Physiotherapy 97, 182\u2013189 (2011).","journal-title":"Physiotherapy"},{"key":"257_CR7","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1016\/S0190-9622(89)70063-3","volume":"20","author":"K Sato","year":"1989","unstructured":"Sato, K., Kang, W. H., Saga, K. & Sato, K. T. Biology of sweat glands and their disorders. 1. Normal sweat gland-function. J. Am. Acad. Dermatol. 20, 537\u2013563 (1989).","journal-title":"J. Am. Acad. Dermatol."},{"key":"257_CR8","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.jcf.2016.02.015","volume":"16","author":"F Vermeulen","year":"2017","unstructured":"Vermeulen, F. et al. Variability of sweat chloride concentration in subjects with cystic fibrosis and G551D mutations. J. Cyst. Fibros. 16, 36\u201340 (2017).","journal-title":"J. Cyst. Fibros."},{"key":"257_CR9","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.jcf.2017.07.008","volume":"17","author":"VA LeGrys","year":"2018","unstructured":"LeGrys, V. A., Moon, T. C., Laux, J., Rock, M. J. & Accurso, F. Analytical and biological variation in repeated sweat chloride concentrations in clinical trials for CFTR modulator therapy. J. Cyst. Fibros. 17, 43\u201349 (2018).","journal-title":"J. Cyst. Fibros."},{"key":"257_CR10","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1007\/s00408-017-9984-6","volume":"195","author":"P Willems","year":"2017","unstructured":"Willems, P., Weekx, S., Meskal, A. & Schouwers, S. Biological variation of chloride and sodium in sweat obtained by pilocarpine iontophoresis in adults: how sure are you about sweat test results? Lung 195, 241\u2013246 (2017).","journal-title":"Lung"},{"key":"257_CR11","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-54202-1","volume":"9","author":"DH Choi","year":"2019","unstructured":"Choi, D. H. et al. Two distinct types of sweat profile in healthy subjects while exercising at constant power output measured by a wearable sweat sensor. Sci. Rep. 9, 17877 (2019).","journal-title":"Sci. Rep."}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0257-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0257-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0257-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T02:07:23Z","timestamp":1670378843000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0257-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,27]]},"references-count":11,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["257"],"URL":"https:\/\/doi.org\/10.1038\/s41746-020-0257-z","relation":{},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,27]]},"assertion":[{"value":"20 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 March 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"49"}}