{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,9]],"date-time":"2025-11-09T03:45:11Z","timestamp":1762659911822,"version":"3.37.3"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T00:00:00Z","timestamp":1590105600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T00:00:00Z","timestamp":1590105600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000038","name":"Gouvernement du Canada | Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["EGP 537690-2018"],"award-info":[{"award-number":["EGP 537690-2018"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>According to medical guidelines, the distinction between \u201chealthy\u201d and \u201cunhealthy\u201d patients is commonly based on single, discrete values taken at an isolated point in time (e.g., blood pressure or core temperature). Perhaps a more robust and insightful diagnosis can be obtained by studying the functional interdependence of such indicators and the homeostasis that controls them. This requires quasi-continuous measurements and a procedure to map the data onto a parsimonious control model with a degree of universality. The current research illustrates this approach using glucose homeostasis as a target. Data were obtained from 41 healthy subjects wearing over-the-counter glucose monitors, and projected onto a simple proportional\u2013integral (PI) controller, widely used in engineering applications. The indicators quantifying the control function are clustered for the great majority of subjects, while a few outliers exhibit less responsive homeostasis. Practical implications for healthcare and education are further discussed.<\/jats:p>","DOI":"10.1038\/s41746-020-0283-x","type":"journal-article","created":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T10:04:00Z","timestamp":1590141840000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Homeostasis as a proportional\u2013integral control system"],"prefix":"10.1038","volume":"3","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4611-3118","authenticated-orcid":false,"given":"Lennaert van","family":"Veen","sequence":"first","affiliation":[]},{"given":"Jacob","family":"Morra","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0035-7128","authenticated-orcid":false,"given":"Adam","family":"Palanica","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1271-2633","authenticated-orcid":false,"given":"Yan","family":"Fossat","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,5,22]]},"reference":[{"key":"283_CR1","doi-asserted-by":"publisher","first-page":"279","DOI":"10.2147\/PPA.S14399","volume":"5","author":"S Cano","year":"2011","unstructured":"Cano, S. & Hobart, J. The problem with health measurement. Patient Prefer. Adher. 5, 279\u2013290 (2011).","journal-title":"Patient Prefer. Adher."},{"key":"283_CR2","first-page":"341","volume":"6","author":"H Br\u00fcssow","year":"2013","unstructured":"Br\u00fcssow, H. What is health? Microb. Biotechnology 6, 341\u2013348 (2013).","journal-title":"Biotechnology"},{"key":"283_CR3","doi-asserted-by":"publisher","first-page":"816","DOI":"10.1016\/j.cell.2015.02.010","volume":"160","author":"ME Kotas","year":"2015","unstructured":"Kotas, M. E. & Medzhitov, R. Homeostasis, inflammation, and disease susceptibility. Cell 160, 816\u2013827 (2015).","journal-title":"Cell"},{"key":"283_CR4","unstructured":"World Health Organization. Global Report on Diabetes. Geneva, Switzerland. https:\/\/www.who.int\/diabetes\/global-report\/en\/ (2016)."},{"key":"283_CR5","unstructured":"International Diabetes Federation. IDF Diabetes Atlas\u20148th Edition. https:\/\/www.idf.org\/e-library\/epidemiology-research\/diabetes-atlas\/134-idf-diabetes-atlas-8th-edition.html (2017). Accessed 24 Mar 2020."},{"key":"283_CR6","unstructured":"American Diabetes Association. Diagnosis. https:\/\/www.diabetes.org\/a1c\/diagnosis (2020). Accessed 24 Mar 2020."},{"key":"283_CR7","doi-asserted-by":"crossref","unstructured":"Masroor, S. van Dongen, M. G. J. Alvarez-Jimenez, R. Burggraaf, K. & Peletier, L.A. Mathematical modeling of the glucagon challenge test. J. Pharmacokinet. Pharm. 46, 553\u2013564 (2019).","DOI":"10.1007\/s10928-019-09655-2"},{"key":"283_CR8","first-page":"1","volume":"33","author":"S Bennett","year":"2000","unstructured":"Bennett, S. The past of PID controllers. Ann. Rev. Control 33, 1\u201311 (2000).","journal-title":"Ann. Rev. Control"},{"key":"283_CR9","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1007\/s10846-013-9947-y","volume":"73","author":"M Alaimo","year":"2014","unstructured":"Alaimo, M., Artale, V., Milazzo, C. L. R. & Ricciardello, A. PID controller applied to hexacopter flight. J. Intel. Robot. Syst. 73, 261\u2013270 (2014).","journal-title":"J. Intel. Robot. Syst."},{"key":"283_CR10","first-page":"E667","volume":"236","author":"RN Bergman","year":"1979","unstructured":"Bergman, R. N., Ider, Y. Z., Bowden, C. R. & Cobelli, C. Quantitative estimation of insulin sensitivity. Am. J. Physiol. 236, E667\u2013E677 (1979).","journal-title":"Am. J. Physiol."},{"key":"283_CR11","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1089\/152091503322640999","volume":"5","author":"GM Steil","year":"2003","unstructured":"Steil, G. M., Rebrin, K., Janowski, Darwin, C. & Saad, M. F. M. F. modeling \u03b2 -cell insulin secretion - implications for closed-loop glucose homeostasis. Diabetes Technol. 5, 953\u2013964 (2003).","journal-title":"Diabetes Technol."},{"key":"283_CR12","doi-asserted-by":"publisher","first-page":"4396","DOI":"10.1210\/jcem.85.11.6982","volume":"85","author":"A Caumo","year":"2000","unstructured":"Caumo, A., Bergman, R. N. & Cobelli, C. Insulin sensitivity from meal tolerance tests in normal subjects: A minimal model index. J. Clin. Endocr. Metab. 85, 4396\u20134402 (2000).","journal-title":"J. Clin. Endocr. Metab."},{"key":"283_CR13","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/j.mbs.2013.05.006","volume":"244","author":"P Palumbo","year":"2013","unstructured":"Palumbo, P., Ditlevsen, S., Bertuzzi, A. & De Gaetano, A. Mathematical modeling of the glucose-insulin system: A review. Math. Biosci. 244, 69\u201381 (2013).","journal-title":"Math. Biosci."},{"key":"283_CR14","doi-asserted-by":"publisher","unstructured":"Jeon, J. et al. Predicting glycaemia in type 1 diabetes patients: experiments in feature engineering and data imputation. J. Healthcare Inform. Res. https:\/\/doi.org\/10.1007\/s41666-019-00063-2 (2019).","DOI":"10.1007\/s41666-019-00063-2"},{"key":"283_CR15","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1089\/dia.2012.0283","volume":"15","author":"K Turksoy","year":"2013","unstructured":"Turksoy, K., Bayrak, E. S., Quinn, L., Littlejohn, E. & Cinar, A. Multivariable adaptive closed-loop control of an artificial pancreas without meal and activity announcement. Diabetes Technol. Ther. 15, 386\u2013400 (2013).","journal-title":"Diabetes Technol. Ther."},{"key":"283_CR16","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.2337\/dc13-2108","volume":"37","author":"FJ Doyle III","year":"2014","unstructured":"Doyle III, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C. & Dassau, E. Closed-loop artificial pancreas systems: engineering the algorithms. Diabetes Care 37, 1191\u20131197 (2014).","journal-title":"Diabetes Care"},{"key":"283_CR17","doi-asserted-by":"publisher","first-page":"1407","DOI":"10.1001\/jama.2016.11708","volume":"316","author":"RM Bergenstal","year":"2016","unstructured":"Bergenstal, R. M. et al. Safety of a hybrid closed-loop insulin delivery system in patients with type-1 diabetes. JAMA 316, 1407\u20131408 (2016).","journal-title":"JAMA"},{"key":"283_CR18","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1109\/MCS.2016.2584318","volume":"36","author":"A Haidar","year":"2016","unstructured":"Haidar, A. The Artificial Pancreas: how closed-loop control is revolutionizing diabetes. IEEE Contr. Sys. Mag. 36, 28\u201347 (2016).","journal-title":"IEEE Contr. Sys. Mag."},{"key":"283_CR19","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1016\/S0169-409X(01)00114-4","volume":"48","author":"RS Parker","year":"2001","unstructured":"Parker, R. S. & Doyle III, F. J. Control-relevant modeling in drug delivery. Adv. Drug Deliv. Rev. 48, 211\u2013228 (2001).","journal-title":"Adv. Drug Deliv. Rev."},{"key":"283_CR20","doi-asserted-by":"publisher","first-page":"066004","DOI":"10.1088\/1741-2560\/7\/6\/066004","volume":"7","author":"O Miranda-Dominguez","year":"2010","unstructured":"Miranda-Dominguez, O., Gonia, J. & Netoff, T. I. Firing rate control of a neuron using a linear proportional-integral controller. J. Neural Eng. 7, 066004 (2010).","journal-title":"J. Neural Eng."},{"key":"283_CR21","doi-asserted-by":"publisher","first-page":"2371","DOI":"10.1016\/j.camwa.2012.05.007","volume":"64","author":"LS Coelho","year":"2012","unstructured":"Coelho, L. S. & Mariani, V. C. Firefly algorithm approach based on chaotic Tinkerbell map applied to multivariable PID controller tuning. Comput. Math. Appl. 64, 2371\u20132382 (2012).","journal-title":"Comput. Math. Appl."},{"key":"283_CR22","doi-asserted-by":"publisher","first-page":"851","DOI":"10.1103\/RevModPhys.65.851","volume":"65","author":"MC Cross","year":"1993","unstructured":"Cross, M. C. & Hohenberg, P. C. Pattern formation outside of equilibrium. Rev. Mod. Phys. 65, 851\u20131112 (1993).","journal-title":"Rev. Mod. Phys."},{"key":"283_CR23","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1017\/S0007114509991632","volume":"103","author":"JA Monro","year":"2010","unstructured":"Monro, J. A., Mishra, S. & Venn, B. Baselines representing blood glucose clearance improve in vitro prediction of the glycaemic impact of customarily consumed food quantities. Brit. J. Nutr. 103, 295\u2013305 (2010).","journal-title":"Brit. J. Nutr."},{"key":"283_CR24","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1177\/193229681000400507","volume":"4","author":"K Rebrin","year":"2010","unstructured":"Rebrin, K., Sheppard, N. F. & Steil, G. M. Use of subcutaneous interstitial fluid glucose to estimate blood glucose: Revisiting Delay and Sensor offset. J. Diabetes Sci. Technol. 4, 1087\u20131098 (2010).","journal-title":"J. Diabetes Sci. Technol."},{"key":"283_CR25","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1177\/193229681300700511","volume":"7","author":"U Hoss","year":"2013","unstructured":"Hoss, U., Budiman, E. S., Liu, H. & Christiansen, M. P. Continuous glucose monitoring in the subcutaneous tissue over a 14-day sensor wear period. J. Diabetes Sci. Technol. 7, 1210\u20131219 (2013).","journal-title":"J. Diabetes Sci. Technol."},{"key":"283_CR26","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1089\/dia.2014.0378","volume":"11","author":"T Bailey","year":"2015","unstructured":"Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J. & Alva, S. The performance and usability of a factory-calibrated flash glucose monitoring system. Diabetes Technol. Ther. 11, 787\u2013794 (2015).","journal-title":"Diabetes Technol. Ther."},{"key":"283_CR27","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1136\/archdischild-2016-311530","volume":"102","author":"J Edge","year":"2017","unstructured":"Edge, J. et al. An alternative sensor-based method for glucose monitoring in children and young people with diabetes. Arch. Dis. Child. 102, 543\u2013549 (2017).","journal-title":"Arch. Dis. Child."},{"key":"283_CR28","unstructured":"All of this software is open source. See https:\/\/pandas.pydata.org\/ for Pandas, https:\/\/numpy.org\/ for NumPy, https:\/\/www.scipy.org\/ for SciPy and https:\/\/matplotlib.org\/ for Matplotlib. Accessed 24 Mar 2020."}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0283-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0283-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0283-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,7]],"date-time":"2022-12-07T02:16:00Z","timestamp":1670379360000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-020-0283-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,22]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["283"],"URL":"https:\/\/doi.org\/10.1038\/s41746-020-0283-x","relation":{},"ISSN":["2398-6352"],"issn-type":[{"type":"electronic","value":"2398-6352"}],"subject":[],"published":{"date-parts":[[2020,5,22]]},"assertion":[{"value":"23 December 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Klick Inc. has filed a provisional patent for the research and algorithm: System and method for evaluating glucose homeostasis. United States Provisional Application Number 62\/930,127 (filed 04 Nov 2019).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"77"}}