{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,25]],"date-time":"2026-11-25T18:20:29Z","timestamp":1795630829595,"version":"4.11.3"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T00:00:00Z","timestamp":1715212800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T00:00:00Z","timestamp":1715212800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Distribution shifts remain a problem for the safe application of regulated medical AI systems, and may impact their real-world performance if undetected. Postmarket shifts can occur for example if algorithms developed on data from various acquisition settings and a heterogeneous population are predominantly applied in hospitals with lower quality data acquisition or other centre-specific acquisition factors, or where some ethnicities are over-represented. Therefore, distribution shift detection could be important for monitoring AI-based medical products during postmarket surveillance. We implemented and evaluated three deep-learning based shift detection techniques (classifier-based, deep kernel, and multiple univariate kolmogorov-smirnov tests) on simulated shifts in a dataset of 130\u2019486 retinal images. We trained a deep learning classifier for diabetic retinopathy grading. We then simulated population shifts by changing the prevalence of patients\u2019 sex, ethnicity, and co-morbidities, and example acquisition shifts by changes in image quality. We observed classification subgroup performance disparities w.r.t. image quality, patient sex, ethnicity and co-morbidity presence. The sensitivity at detecting referable diabetic retinopathy ranged from 0.50 to 0.79 for different ethnicities. This motivates the need for detecting shifts after deployment. Classifier-based tests performed best overall, with perfect detection rates for quality and co-morbidity subgroup shifts at a sample size of 1000. It was the only method to detect shifts in patient sex, but required large sample sizes (\n                    <jats:inline-formula>\n                      <jats:alternatives>\n                        <jats:tex-math>$$&gt; 30^{\\prime} 000$$<\/jats:tex-math>\n                        <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                          <mml:mrow>\n                            <mml:mo>&gt;<\/mml:mo>\n                            <mml:mn>3<\/mml:mn>\n                            <mml:msup>\n                              <mml:mrow>\n                                <mml:mn>0<\/mml:mn>\n                              <\/mml:mrow>\n                              <mml:mrow>\n                                <mml:mo>\u2032<\/mml:mo>\n                              <\/mml:mrow>\n                            <\/mml:msup>\n                            <mml:mn>000<\/mml:mn>\n                          <\/mml:mrow>\n                        <\/mml:math>\n                      <\/jats:alternatives>\n                    <\/jats:inline-formula>\n                    ). All methods identified easier-to-detect out-of-distribution shifts with small (\u2264300) sample sizes. We conclude that effective tools exist for detecting clinically relevant distribution shifts. In particular classifier-based tests can be easily implemented components in the post-market surveillance strategy of medical device manufacturers.\n                  <\/jats:p>","DOI":"10.1038\/s41746-024-01085-w","type":"journal-article","created":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T15:02:21Z","timestamp":1715266941000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":63,"title":["Distribution shift detection for the postmarket surveillance of medical AI algorithms: a retrospective simulation study"],"prefix":"10.1038","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4377-7074","authenticated-orcid":false,"given":"Lisa M.","family":"Koch","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3629-4384","authenticated-orcid":false,"given":"Christian F.","family":"Baumgartner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0199-4727","authenticated-orcid":false,"given":"Philipp","family":"Berens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,5,9]]},"reference":[{"key":"1085_CR1","doi-asserted-by":"publisher","first-page":"e271","DOI":"10.1016\/S2589-7500(19)30123-2","volume":"1","author":"X Liu","year":"2019","unstructured":"Liu, X. et al. A comparison of deep learning performance against health-care professionals in detecting diseases from medical imaging: a systematic review and meta-analysis. Lancet Digital Health 1, e271\u2013e297 (2019).","journal-title":"Lancet Digital Health"},{"key":"1085_CR2","unstructured":"European Parliament, Council of the European Union. Regulation (EU) 2017\/745 of the European Parliament and of the Council of 5 april 2017 on medical devices, amending Directive 2001\/83\/EC, Regulation (EC) No 178\/2002 and Regulation (EC) No 1223\/2009 and repealing Council Directives 90\/385\/EEC and 93\/42\/EEC. Official Journal of the European Union (2017)."},{"key":"1085_CR3","doi-asserted-by":"publisher","DOI":"10.1038\/s41746-020-00324-0","volume":"3","author":"S Benjamens","year":"2020","unstructured":"Benjamens, S., Dhunnoo, P. & Mesk\u00f3, B. The state of artificial intelligence-based fda-approved medical devices and algorithms: An online database. NPJ Digit. Med. 3, 118 (2020).","journal-title":"NPJ Digit. Med."},{"key":"1085_CR4","unstructured":"Food, U. & (FDA), D. A. Artificial Intelligence\/Machine learning (AI\/ML)-Based Software as a Medical Device (SaMD) Action Plan (2021). https:\/\/www.fda.gov\/media\/145022\/download."},{"key":"1085_CR5","unstructured":"U.S. Food and Drug Administration. Good machine learning practice for medical device development: Guiding principles. https:\/\/www.fda.gov\/medical-devices\/software-medical-device-samd\/good-machine-learning-practice-medical-device-development-guiding-principles (2021). Accessed: 20 December 2023."},{"key":"1085_CR6","unstructured":"U.S. Food and Drug Administration, Health Canada, and Medicines and Healthcare products Regulatory Agency. Predetermined change control plans for machine learning-enabled medical devices: Guiding principles. https:\/\/www.fda.gov\/medical-devices\/medical-devices-news-and-events\/cdrh-issues-guiding-principles-predetermined-change-control-plans-machine-learning-enabled-medical (2023)."},{"key":"1085_CR7","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1056\/NEJMc2104626","volume":"385","author":"SG Finlayson","year":"2021","unstructured":"Finlayson, S. G. et al. The clinician and dataset shift in artificial intelligence. N. Engl. J. Med. 385, 283\u2013286 (2021).","journal-title":"N. Engl. J. Med."},{"key":"1085_CR8","doi-asserted-by":"publisher","first-page":"e384","DOI":"10.1016\/S2589-7500(22)00003-6","volume":"4","author":"X Liu","year":"2022","unstructured":"Liu, X. et al. The medical algorithmic audit. Lancet Digit. Health 4, e384\u2013e397 (2022).","journal-title":"Lancet Digit. Health"},{"key":"1085_CR9","unstructured":"Koch, L. M., Sch\u00fcrch, C. M., Gretton, A. & Berens, P. Hidden in plain sight: Subgroup shifts escape OOD detection. In Proc. Medical Imaging with Deep Learning (MIDL) (2022)."},{"key":"1085_CR10","doi-asserted-by":"crossref","unstructured":"Oakden-Rayner, L., Dunnmon, J., Carneiro, G. & Re, C. Hidden stratification causes clinically meaningful failures in machine learning for medical imaging. In Proceedings of the ACM Conference on Health, Inference, and Learning (2020).","DOI":"10.1145\/3368555.3384468"},{"key":"1085_CR11","unstructured":"Eyuboglu, S. et al. Domino: Discovering systematic errors with cross-modal embeddings. In International Conference on Learning Representations (2022)."},{"key":"1085_CR12","unstructured":"Jain, S., Lawrence, H., Moitra, A. & Madry, A. Distilling model failures as directions in latent space. In Proc. International Conference on Learning Representations (ICLR) (2023)."},{"key":"1085_CR13","unstructured":"Hendrycks, D. & Gimpel, K. A Baseline for Detecting Misclassified and Out-of-Distribution Examples in Neural Networks. In Proc. International Conference on Learning Representations (ICLR) (2017)."},{"key":"1085_CR14","unstructured":"Liang, S., Li, Y. & Srikant, R. Enhancing The Reliability of Out-of-distribution Image Detection in Neural Networks. In Proc. International Conference on Learning Representations (ICLR) (2018)."},{"key":"1085_CR15","doi-asserted-by":"crossref","unstructured":"Hsu, Y.-C., Shen, Y., Jin, H. & Kira, Z. Generalized odin: Detecting out-of-distribution image without learning from out-of-distribution data. In Proc. Computer Vision and Pattern Recognition (CVPR) (2020).","DOI":"10.1109\/CVPR42600.2020.01096"},{"key":"1085_CR16","unstructured":"Hendrycks, D., Mazeika, M. & Dietterich, T. Deep anomaly detection with outlier exposure. In Proc. International Conference on Learning Representations (ICLR) (2019)."},{"key":"1085_CR17","doi-asserted-by":"crossref","unstructured":"Yu, Q. & Aizawa, K. Unsupervised out-of-distribution detection by maximum classifier discrepancy. In Proc. International Conference on Computer Vision (ICCV) (2019).","DOI":"10.1109\/ICCV.2019.00961"},{"key":"1085_CR18","unstructured":"Yang, J. et al. OpenOOD: Benchmarking generalized out-of-distribution detection. In Proc. Neural Information Processing Systems (NeurIPS) Datasets and Benchmarks Track (2022)."},{"key":"1085_CR19","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/S0378-3758(00)00115-4","volume":"90","author":"H Shimodaira","year":"2000","unstructured":"Shimodaira, H. Improving predictive inference under covariate shift by weighting the log-likelihood function. J. Stat. Planning Inference 90, 227\u2013244 (2000).","journal-title":"J. Stat. Planning Inference"},{"key":"1085_CR20","unstructured":"Sagawa, S., Koh, P. W., Hashimoto, T. B. & Liang, P. Distributionally robust neural networks. In International Conference on Learning Representations (2020)."},{"key":"1085_CR21","doi-asserted-by":"crossref","unstructured":"Cui, Y., Jia, M., Lin, T.-Y., Song, Y. & Belongie, S. Class-balanced loss based on effective number of samples. In Proceedings of the IEEE\/CVF Conference on Computer Vision and Pattern Recognition (CVPR) (2019).","DOI":"10.1109\/CVPR.2019.00949"},{"key":"1085_CR22","unstructured":"Koh, P. W. et al. WILDS: A benchmark of in-the-wild distribution shifts. In Proc. International Conference on Machine Learning (ICML) (2021)."},{"key":"1085_CR23","unstructured":"K\u00fcbler, J. M., Stimper, V., Buchholz, S., Muandet, K. & Sch\u00f6lkopf, B. Automl two-sample test. In Proc. Advances in Neural Information Processing Systems (NeurIPS) (2022)."},{"key":"1085_CR24","unstructured":"Rabanser, S., G\u00fcnnemann, S. & Lipton, Z. C. Failing Loudly: An Empirical Study of Methods for Detecting Dataset Shift. In Proc. Advances in Neural Information Processing Systems (NeurIPS) (2019)."},{"key":"1085_CR25","unstructured":"Liu, F. et al. Learning Deep Kernels for Non-Parametric Two-Sample Tests. In Proc. International Conference on Machine Learning (ICML) (2020)."},{"key":"1085_CR26","doi-asserted-by":"crossref","unstructured":"Cheng, X. & Cloninger, A. Classification logit two-sample testing by neural networks for differentiating near manifold densities. IEEE Transactions on Information Theory (2022).","DOI":"10.1109\/TIT.2022.3175691"},{"key":"1085_CR27","unstructured":"Lopez-Paz, D. & Oquab, M. Revisiting classifier two-sample tests. In International Conference on Learning Representations (ICLR) (2017)."},{"key":"1085_CR28","doi-asserted-by":"publisher","first-page":"101724","DOI":"10.1016\/j.media.2020.101724","volume":"64","author":"MS Ayhan","year":"2020","unstructured":"Ayhan, M. S. et al. Expert-validated estimation of diagnostic uncertainty for deep neural networks in diabetic retinopathy detection. Med. Image Anal. 64, 101724 (2020).","journal-title":"Med. Image Anal."},{"key":"1085_CR29","doi-asserted-by":"crossref","unstructured":"Huang, Y., Lin, L., Cheng, P., Lyu, J. & Tang, X. Identifying the key components in resnet-50 for diabetic retinopathy grading from fundus images: a systematic investigation. arXiv:2110.14160 (2021).","DOI":"10.2139\/ssrn.4098657"},{"key":"1085_CR30","unstructured":"Kaggle. Kaggle competition on diabetic retinopathy detection (2015). https:\/\/www.kaggle.com\/c\/diabetic-retinopathy-detection\/data. Accessed: 2024-01-08."},{"key":"1085_CR31","doi-asserted-by":"crossref","unstructured":"He, K., Zhang, X., Ren, S. & Sun, J. Deep residual learning for image recognition. In Proc. Conference on Computer Vision and Pattern Recognition (CVPR) (2016).","DOI":"10.1109\/CVPR.2016.90"},{"key":"1085_CR32","unstructured":"Casella, G. & Berger, R. Statistical Inference (Duxbury, 2002)."},{"key":"1085_CR33","first-page":"723","volume":"13","author":"A Gretton","year":"2012","unstructured":"Gretton, A., Borgwardt, K., Rasch, M. J., Schoelkopf, B. & Smola, A. J. Mach. Learn. Res. 13, 723\u2013773 (2012).","journal-title":"J. Mach. Learn. Res."},{"key":"1085_CR34","unstructured":"Sutherland, D. J. et al. Generative Models and Model Criticism via Optimized Maximum Mean Discrepancy. In Proc. International Conference on Learning Representations (ICLR) (2017)."}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01085-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01085-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01085-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,9]],"date-time":"2024-05-09T15:05:46Z","timestamp":1715267146000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01085-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,9]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["1085"],"URL":"https:\/\/doi.org\/10.1038\/s41746-024-01085-w","relation":{},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,9]]},"assertion":[{"value":"14 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"120"}}