{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T18:55:48Z","timestamp":1783018548506,"version":"3.54.6"},"reference-count":75,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,6]],"date-time":"2024-07-06T00:00:00Z","timestamp":1720224000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,7,6]],"date-time":"2024-07-06T00:00:00Z","timestamp":1720224000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Computer-aided implant surgery has undergone continuous development in recent years. In this study, active and passive systems of dynamic navigation were divided into active dynamic navigation system group and passive dynamic navigation system group (ADG and PDG), respectively. Active, passive and semi-active implant robots were divided into active robot group, passive robot group and semi-active robot group (ARG, PRG and SRG), respectively. Each group placed two implants (FDI tooth positions 31 and 36) in a model 12 times. The accuracy of 216 implants in 108 models were analysed. The coronal deviations of ADG, PDG, ARG, PRG and SRG were 0.85\u2009\u00b1\u20090.17\u2009mm, 1.05\u2009\u00b1\u20090.42\u2009mm, 0.29\u2009\u00b1\u20090.15\u2009mm, 0.40\u2009\u00b1\u20090.16\u2009mm and 0.33\u2009\u00b1\u20090.14\u2009mm, respectively. The apical deviations of the five groups were 1.11\u2009\u00b1\u20090.23\u2009mm, 1.07\u2009\u00b1\u20090.38\u2009mm, 0.29\u2009\u00b1\u20090.15\u2009mm, 0.50\u2009\u00b1\u20090.19\u2009mm and 0.36\u2009\u00b1\u20090.16\u2009mm, respectively. The axial deviations of the five groups were 1.78\u2009\u00b1\u20090.73\u00b0, 1.99\u2009\u00b1\u20091.20\u00b0, 0.61\u2009\u00b1\u20090.25\u00b0, 1.04\u2009\u00b1\u20090.37\u00b0 and 0.42\u2009\u00b1\u20090.18\u00b0, respectively. The coronal, apical and axial deviations of ADG were higher than those of ARG, PRG and SRG (all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). Similarly, the coronal, apical and axial deviations of PDG were higher than those of ARG, PRG, and SRG (all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). Dynamic and robotic computer-aided implant surgery may show good implant accuracy in vitro. However, the accuracy and stability of implant robots are higher than those of dynamic navigation systems.<\/jats:p>","DOI":"10.1038\/s41746-024-01178-6","type":"journal-article","created":{"date-parts":[[2024,7,6]],"date-time":"2024-07-06T13:01:29Z","timestamp":1720270889000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["Accuracy of dental implant placement using different dynamic navigation and robotic systems: an in vitro study"],"prefix":"10.1038","volume":"7","author":[{"given":"Zonghe","family":"Xu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lin","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuang","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanjun","family":"Xiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sihui","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiang","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0009-1304-5703","authenticated-orcid":false,"given":"Jianbin","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9469-831X","authenticated-orcid":false,"given":"Dong","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,6]]},"reference":[{"key":"1178_CR1","doi-asserted-by":"publisher","first-page":"3281","DOI":"10.1007\/s00784-020-03205-8","volume":"24","author":"H Ga\u00eata-Araujo","year":"2020","unstructured":"Ga\u00eata-Araujo, H., Oliveira-Santos, N., Mancini, A. X. M., Oliveira, M. L. & Oliveira-Santos, C. Retrospective assessment of dental implant-related perforations of relevant anatomical structures and inadequate spacing between implants\/teeth using cone-beam computed tomography. Clin. Oral. Investig. 24, 3281\u20133288 (2020).","journal-title":"Clin. Oral. Investig."},{"key":"1178_CR2","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1016\/j.prosdent.2022.03.029","volume":"127","author":"S Rawal","year":"2022","unstructured":"Rawal, S. Guided innovations: robot-assisted dental implant surgery. J. Prosthet. Dent. 127, 673\u2013674 (2022).","journal-title":"J. Prosthet. Dent."},{"key":"1178_CR3","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1016\/j.coms.2019.08.001","volume":"31","author":"N Panchal","year":"2019","unstructured":"Panchal, N., Mahmood, L., Retana, A. & Emery, R. 3rd Dynamic navigation for dental implant surgery. Oral. Maxillofac. Surg. Clin. North Am. 31, 539\u2013547 (2019).","journal-title":"Oral. Maxillofac. Surg. Clin. North Am."},{"key":"1178_CR4","doi-asserted-by":"publisher","first-page":"S291","DOI":"10.1002\/JPER.16-0810","volume":"89","author":"CHF H\u00e4mmerle","year":"2018","unstructured":"H\u00e4mmerle, C. H. F. & Tarnow, D. The etiology of hard- and soft-tissue deficiencies at dental implants: A narrative review. J. Periodontol. 89, S291\u2013s303 (2018).","journal-title":"J. Periodontol."},{"key":"1178_CR5","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.cxom.2020.05.001","volume":"28","author":"GR Deeb","year":"2020","unstructured":"Deeb, G. R., Tran, D. Q. & Deeb, J. G. Computer-aided planning and placement in implant surgery. Atlas Oral. Maxillofac. Surg. Clin. North Am. 28, 53\u201358 (2020).","journal-title":"Atlas Oral. Maxillofac. Surg. Clin. North Am."},{"key":"1178_CR6","doi-asserted-by":"publisher","first-page":"104265","DOI":"10.1016\/j.jdent.2022.104265","volume":"125","author":"MWH B\u00f6se","year":"2022","unstructured":"B\u00f6se, M. W. H., Beuer, F., Schwitalla, A., Bruhnke, M. & Herklotz, I. Dynamic navigation for dental implant placement in single-tooth gaps: a preclinical pilot investigation. J. Dent. 125, 104265 (2022).","journal-title":"J. Dent."},{"key":"1178_CR7","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1111\/clr.13309","volume":"29","author":"D Wismeijer","year":"2018","unstructured":"Wismeijer, D. et al. Group 5 ITI consensus report: Digital technologies. Clin. Oral. Implants Res. 29, 436\u2013442 (2018).","journal-title":"Clin. Oral. Implants Res."},{"key":"1178_CR8","first-page":"9","volume":"34","author":"F Cecchetti","year":"2020","unstructured":"Cecchetti, F., Di Girolamo, M., Ippolito, D. G. & Baggi, L. Computer-guided implant surgery: Analysis of dynamic navigation systems and digital accuracy. J. Biol. Regul. Homeost. Agents 34, 9\u201317 (2020). Dental supplement.","journal-title":"J. Biol. Regul. Homeost. Agents"},{"key":"1178_CR9","doi-asserted-by":"publisher","unstructured":"Bathija, A. et al. Accuracy of static computer-aided implant surgery (S-CAIS) using CAD-CAM surgical templates fabricated from different additive manufacturing technologies. J. Prosthet. Dent. https:\/\/doi.org\/10.1016\/j.prosdent.2023.03.025 (2023).","DOI":"10.1016\/j.prosdent.2023.03.025"},{"key":"1178_CR10","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1016\/j.joms.2023.04.009","volume":"81","author":"L Fish","year":"2023","unstructured":"Fish, L. Utilizing robotic technology to place dental implants. J. Oral. Maxillofac. Surg. 81, 802\u2013803 (2023).","journal-title":"J. Oral. Maxillofac. Surg."},{"key":"1178_CR11","doi-asserted-by":"publisher","first-page":"104240","DOI":"10.1016\/j.jdent.2022.104240","volume":"124","author":"XY Wang","year":"2022","unstructured":"Wang, X. Y. et al. The accuracy and learning curve of active and passive dynamic navigation-guided dental implant surgery: an in vitro study. J. Dent. 124, 104240 (2022).","journal-title":"J. Dent."},{"key":"1178_CR12","doi-asserted-by":"publisher","first-page":"65005","DOI":"10.1117\/1.JBO.22.6.065005","volume":"22","author":"Z Zhou","year":"2017","unstructured":"Zhou, Z. et al. Optical surgical instrument tracking system based on the principle of stereo vision. J. Biomed. Opt. 22, 65005 (2017).","journal-title":"J. Biomed. Opt."},{"key":"1178_CR13","doi-asserted-by":"publisher","first-page":"15827","DOI":"10.1364\/OE.27.015827","volume":"27","author":"M Zhang","year":"2019","unstructured":"Zhang, M. et al. Multiple instruments motion trajectory tracking in optical surgical navigation. Opt. Express 27, 15827\u201315845 (2019).","journal-title":"Opt. Express"},{"key":"1178_CR14","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.coms.2019.03.013","volume":"31","author":"Y Wu","year":"2019","unstructured":"Wu, Y., Wang, F., Fan, S. & Chow, J. K. Robotics in dental implantology. Oral. Maxillofac. Surg. Clin. North Am. 31, 513\u2013518 (2019).","journal-title":"Oral. Maxillofac. Surg. Clin. North Am."},{"key":"1178_CR15","doi-asserted-by":"crossref","unstructured":"Yan, Y. & Jia, Y. A review on human comfort factors, measurements, and improvements in human-robot collaboration. Sensors (Basel) 22 (2022).","DOI":"10.3390\/s22197431"},{"key":"1178_CR16","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1146\/annurev-bioeng-060418-052502","volume":"21","author":"J Troccaz","year":"2019","unstructured":"Troccaz, J., Dagnino, G. & Yang, G. Z. Frontiers of medical robotics: From concept to systems to clinical translation. Annu Rev. Biomed. Eng. 21, 193\u2013218 (2019).","journal-title":"Annu Rev. Biomed. Eng."},{"key":"1178_CR17","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1016\/j.prosdent.2020.12.048","volume":"128","author":"SL Bolding","year":"2022","unstructured":"Bolding, S. L. & Reebye, U. N. Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches. J. Prosthet. Dent. 128, 639\u2013647 (2022).","journal-title":"J. Prosthet. Dent."},{"key":"1178_CR18","doi-asserted-by":"publisher","first-page":"6594","DOI":"10.3390\/jcm11216594","volume":"11","author":"S Yang","year":"2022","unstructured":"Yang, S., Chen, J., Li, A., Li, P. & Xu, S. Autonomous robotic surgery for immediately loaded implant-supported maxillary full-arch prosthesis: A case report. J. Clin. Med. 11, 6594 (2022).","journal-title":"J. Clin. Med."},{"key":"1178_CR19","doi-asserted-by":"publisher","unstructured":"Jia, S., Wang, G., Zhao, Y. & Wang, X. Accuracy of an autonomous dental implant robotic system versus static guide-assisted implant surgery: A retrospective clinical study. J. Prosthet. Dent. https:\/\/doi.org\/10.1016\/j.prosdent.2023.04.027 (2023).","DOI":"10.1016\/j.prosdent.2023.04.027"},{"key":"1178_CR20","doi-asserted-by":"publisher","first-page":"2479","DOI":"10.1007\/s00784-021-03833-8","volume":"25","author":"A Jorba-Garc\u00eda","year":"2021","unstructured":"Jorba-Garc\u00eda, A., Gonz\u00e1lez-Barnadas, A., Camps-Font, O., Figueiredo, R. & Valmaseda-Castell\u00f3n, E. Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis. Clin. Oral. Investig. 25, 2479\u20132494 (2021).","journal-title":"Clin. Oral. Investig."},{"key":"1178_CR21","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1111\/clr.14083","volume":"34","author":"W Chen","year":"2023","unstructured":"Chen, W. et al. Accuracy of dental implant placement with a robotic system in partially edentulous patients: A prospective, single-arm clinical trial. Clin. Oral. Implants Res. 34, 707\u2013718 (2023).","journal-title":"Clin. Oral. Implants Res."},{"key":"1178_CR22","doi-asserted-by":"publisher","first-page":"104567","DOI":"10.1016\/j.jdent.2023.104567","volume":"135","author":"X Yu","year":"2023","unstructured":"Yu, X., Tao, B., Wang, F. & Wu, Y. Accuracy assessment of dynamic navigation during implant placement: A systematic review and meta-analysis of clinical studies in the last 10 years. J. Dent. 135, 104567 (2023).","journal-title":"J. Dent."},{"key":"1178_CR23","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1111\/jerd.12710","volume":"33","author":"A Pozzi","year":"2021","unstructured":"Pozzi, A., Hansson, L., Carosi, P. & Arcuri, L. Dynamic navigation guided surgery and prosthetics for immediate loading of complete-arch restoration. J. Esthet. Restor. Dent. 33, 224\u2013236 (2021).","journal-title":"J. Esthet. Restor. Dent."},{"key":"1178_CR24","doi-asserted-by":"publisher","first-page":"104436","DOI":"10.1016\/j.jdent.2023.104436","volume":"130","author":"A Bhalerao","year":"2023","unstructured":"Bhalerao, A., Marimuthu, M., Wahab, A. & Ayoub, A. Dynamic navigation for zygomatic implant placement: A randomized clinical study comparing the flapless versus the conventional approach. J. Dent. 130, 104436 (2023).","journal-title":"J. Dent."},{"key":"1178_CR25","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1111\/clr.13961","volume":"33","author":"SM Wei","year":"2022","unstructured":"Wei, S. M. et al. Does machine-vision-assisted dynamic navigation improve the accuracy of digitally planned prosthetically guided immediate implant placement? a randomized controlled trial. Clin. Oral. Implants Res. 33, 804\u2013815 (2022).","journal-title":"Clin. Oral. Implants Res."},{"key":"1178_CR26","doi-asserted-by":"publisher","first-page":"451","DOI":"10.4103\/jisp.jisp_581_20","volume":"25","author":"S Jain","year":"2021","unstructured":"Jain, S. & Solanki, A. A dynamic surgical navigational approach for immediate implantation and transcrestal sinus augmentation. J. Indian Soc. Periodontol. 25, 451\u2013456 (2021).","journal-title":"J. Indian Soc. Periodontol."},{"key":"1178_CR27","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1563\/aaid-joi-D-22-00053","volume":"49","author":"O Bishbish","year":"2023","unstructured":"Bishbish, O., Kan, J. & Kim, Y. J. Guided lateral window osteotomy using dynamic navigation for maxillary sinus augmentation: a novel technique. J. Oral. Implantol. 49, 316\u2013321 (2023).","journal-title":"J. Oral. Implantol."},{"key":"1178_CR28","doi-asserted-by":"publisher","unstructured":"Yang, S. et al. Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series. J. Dent. https:\/\/doi.org\/10.1016\/j.jdent.2023.104451 (2023).","DOI":"10.1016\/j.jdent.2023.104451"},{"key":"1178_CR29","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-023-00474-2","volume":"9","author":"C Li","year":"2023","unstructured":"Li, C. et al. Autonomous robotic surgery for zygomatic implant placement and immediately loaded implant-supported full-arch prosthesis: a preliminary research. Int J. Implant Dent. 9, 12 (2023).","journal-title":"Int J. Implant Dent."},{"key":"1178_CR30","doi-asserted-by":"publisher","first-page":"980","DOI":"10.3390\/jcm9040980","volume":"9","author":"CC Lin","year":"2020","unstructured":"Lin, C. C. et al. Fully digital workflow for planning static guided implant surgery: A prospective accuracy study. J. Clin. Med. 9, 980 (2020).","journal-title":"J. Clin. Med."},{"key":"1178_CR31","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1111\/prd.12411","volume":"88","author":"T Chackartchi","year":"2022","unstructured":"Chackartchi, T., Romanos, G. E., Parkanyi, L., Schwarz, F. & Sculean, A. Reducing errors in guided implant surgery to optimize treatment outcomes. Periodontol 2000 88, 64\u201372 (2022).","journal-title":"Periodontol 2000"},{"key":"1178_CR32","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1111\/cid.12901","volume":"22","author":"EN Naeini","year":"2020","unstructured":"Naeini, E. N., Atashkadeh, M., De Bruyn, H. & D\u2019Haese, J. Narrative review regarding the applicability, accuracy, and clinical outcome of flapless implant surgery with or without computer guidance. Clin. Implant Dent. Relat. Res. 22, 454\u2013467 (2020).","journal-title":"Clin. Implant Dent. Relat. Res."},{"key":"1178_CR33","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1016\/j.dental.2021.06.001","volume":"37","author":"TCT van Riet","year":"2021","unstructured":"van Riet, T. C. T. et al. Robot technology in dentistry, part one of a systematic review: Literature characteristics. Dent. Mater. 37, 1217\u20131226 (2021).","journal-title":"Dent. Mater."},{"key":"1178_CR34","doi-asserted-by":"publisher","first-page":"1227","DOI":"10.1016\/j.dental.2021.06.002","volume":"37","author":"TCT van Riet","year":"2021","unstructured":"van Riet, T. C. T. et al. Robot technology in dentistry, part two of a systematic review: An overview of initiatives. Dent. Mater. 37, 1227\u20131236 (2021).","journal-title":"Dent. Mater."},{"key":"1178_CR35","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1080\/17434440.2021.1886075","volume":"18","author":"YW Chen","year":"2021","unstructured":"Chen, Y. W. et al. Computer-assisted surgery in medical and dental applications. Expert Rev. Med. Devices 18, 669\u2013696 (2021).","journal-title":"Expert Rev. Med. Devices"},{"key":"1178_CR36","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1111\/clr.13346","volume":"29","author":"A Tahmaseb","year":"2018","unstructured":"Tahmaseb, A., Wu, V., Wismeijer, D., Coucke, W. & Evans, C. The accuracy of static computer-aided implant surgery: a systematic review and meta-analysis. Clin. Oral. Implants Res. 29, 416\u2013435 (2018).","journal-title":"Clin. Oral. Implants Res."},{"key":"1178_CR37","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1902\/jop.2005.76.4.503","volume":"76","author":"GA Di Giacomo","year":"2005","unstructured":"Di Giacomo, G. A., Cury, P. R., de Araujo, N. S., Sendyk, W. R. & Sendyk, C. L. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J. Periodontol. 76, 503\u2013507 (2005).","journal-title":"J. Periodontol."},{"key":"1178_CR38","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1111\/prd.12175","volume":"73","author":"J D\u2019Haese","year":"2017","unstructured":"D\u2019Haese, J., Ackhurst, J., Wismeijer, D., De Bruyn, H. & Tahmaseb, A. Current state of the art of computer-guided implant surgery. Periodontol 2000 73, 121\u2013133 (2017).","journal-title":"Periodontol 2000"},{"key":"1178_CR39","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.joms.2015.09.022","volume":"74","author":"MS Block","year":"2016","unstructured":"Block, M. S. & Emery, R. W. Static or dynamic navigation for implant placement-choosing the method of guidance. J. Oral. Maxillofac. Surg. 74, 269\u2013277 (2016).","journal-title":"J. Oral. Maxillofac. Surg."},{"key":"1178_CR40","doi-asserted-by":"publisher","first-page":"54","DOI":"10.3390\/jcm8010054","volume":"8","author":"SW Pyo","year":"2019","unstructured":"Pyo, S. W., Lim, Y. J., Koo, K. T. & Lee, J. Methods used to assess the 3D accuracy of dental implant positions in computer-guided implant placement: A review. J. Clin. Med. 8, 54 (2019).","journal-title":"J. Clin. Med."},{"key":"1178_CR41","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1097\/ID.0000000000000853","volume":"28","author":"DA Sigcho L\u00f3pez","year":"2019","unstructured":"Sigcho L\u00f3pez, D. A., Garc\u00eda, I., Da Silva Salomao, G. & Cruz Lagan\u00e1, D. Potential deviation factors affecting stereolithographic surgical guides: a systematic review. Implant Dent. 28, 68\u201373 (2019).","journal-title":"Implant Dent."},{"key":"1178_CR42","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1111\/jopr.13356","volume":"30","author":"P Papaspyridakos","year":"2021","unstructured":"Papaspyridakos, P., De Souza, A., Bathija, A., Kang, K. & Chochlidakis, K. Complete digital workflow for mandibular full-arch implant rehabilitation in 3 appointments. J. Prosthodont 30, 548\u2013552 (2021).","journal-title":"J. Prosthodont"},{"key":"1178_CR43","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/s11701-019-00986-3","volume":"14","author":"Q He","year":"2020","unstructured":"He, Q. et al. Robotic lateral cervical lymph node dissection via bilateral axillo-breast approach for papillary thyroid carcinoma: a single-center experience of 260 cases. J. Robot Surg. 14, 317\u2013323 (2020).","journal-title":"J. Robot Surg."},{"key":"1178_CR44","doi-asserted-by":"publisher","first-page":"482","DOI":"10.1002\/rcs.1560","volume":"10","author":"D Wang","year":"2014","unstructured":"Wang, D. et al. Preliminary study on a miniature laser manipulation robotic device for tooth crown preparation. Int J. Med. Robot 10, 482\u2013494 (2014).","journal-title":"Int J. Med. Robot"},{"key":"1178_CR45","doi-asserted-by":"publisher","first-page":"3308","DOI":"10.3390\/s21103308","volume":"21","author":"P Ahmad","year":"2021","unstructured":"Ahmad, P. et al. Dental robotics: A disruptive technology. Sensors (Basel). 21, 3308 (2021).","journal-title":"Sensors (Basel)."},{"key":"1178_CR46","doi-asserted-by":"publisher","first-page":"e121","DOI":"10.11607\/jomi.8770","volume":"36","author":"G Pellegrino","year":"2021","unstructured":"Pellegrino, G. et al. Dynamic navigation in implant dentistry: a systematic review and meta-analysis. Int. J. Oral. Maxillofac. Implants 36, e121\u2013e140 (2021).","journal-title":"Int. J. Oral. Maxillofac. Implants"},{"key":"1178_CR47","doi-asserted-by":"publisher","first-page":"352","DOI":"10.1111\/cid.13090","volume":"24","author":"F Ma","year":"2022","unstructured":"Ma, F., Sun, F., Wei, T. & Ma, Y. Comparison of the accuracy of two different dynamic navigation system registration methods for dental implant placement: A retrospective study. Clin. Implant Dent. Relat. Res. 24, 352\u2013360 (2022).","journal-title":"Clin. Implant Dent. Relat. Res"},{"key":"1178_CR48","first-page":"170","volume":"56","author":"SZ Bai","year":"2021","unstructured":"Bai, S. Z. et al. Animal experiment on the accuracy of the autonomous dental implant robotic system. Zhonghua Kou Qiang Yi Xue Za Zhi 56, 170\u2013174 (2021).","journal-title":"Zhonghua Kou Qiang Yi Xue Za Zhi"},{"key":"1178_CR49","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1016\/j.ijom.2022.12.002","volume":"52","author":"M Olivetto","year":"2023","unstructured":"Olivetto, M., Bettoni, J., Testelin, S. & Lefranc, M. Zygomatic implant placement using a robot-assisted flapless protocol: proof of concept. Int J. Oral. Maxillofac. Surg. 52, 710\u2013715 (2023).","journal-title":"Int J. Oral. Maxillofac. Surg."},{"key":"1178_CR50","doi-asserted-by":"publisher","DOI":"10.1186\/s12903-023-02873-8","volume":"23","author":"J Chen","year":"2023","unstructured":"Chen, J. et al. Comparison the accuracy of a novel implant robot surgery and dynamic navigation system in dental implant surgery: An in vitro pilot study. BMC Oral. Health 23, 179 (2023).","journal-title":"BMC Oral. Health"},{"key":"1178_CR51","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2022.104170","volume":"123","author":"B Tao","year":"2022","unstructured":"Tao, B. et al. Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study. J. Dent. 123, 104170 (2022).","journal-title":"J. Dent."},{"key":"1178_CR52","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/s10033-022-00732-1","volume":"35","author":"B Yan","year":"2022","unstructured":"Yan, B. et al. Optics-guided robotic system for dental implant surgery. Chin. J. Mech. Eng. 35, 55 (2022).","journal-title":"Chin. J. Mech. Eng."},{"key":"1178_CR53","doi-asserted-by":"publisher","first-page":"2450","DOI":"10.3390\/s23052450","volume":"23","author":"M Sin","year":"2023","unstructured":"Sin, M. et al. Development of a real-time 6-DOF motion-tracking system for robotic computer-assisted implant surgery. Sensors (Basel). 23, 2450 (2023).","journal-title":"Sensors (Basel)."},{"key":"1178_CR54","doi-asserted-by":"publisher","first-page":"104153","DOI":"10.1016\/j.compbiomed.2020.104153","volume":"129","author":"KJ Cheng","year":"2021","unstructured":"Cheng, K. J. et al. Accuracy of dental implant surgery with robotic position feedback and registration algorithm: an in-vitro study. Comput. Biol. Med. 129, 104153 (2021).","journal-title":"Comput. Biol. Med."},{"key":"1178_CR55","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1111\/eje.12447","volume":"23","author":"J Golob Deeb","year":"2019","unstructured":"Golob Deeb, J. et al. Exploring training dental implant placement using computer-guided implant navigation system for predoctoral students: a pilot study. Eur. J. Dent. Educ. 23, 415\u2013423 (2019).","journal-title":"Eur. J. Dent. Educ."},{"key":"1178_CR56","doi-asserted-by":"publisher","first-page":"104443","DOI":"10.1016\/j.jdent.2023.104443","volume":"130","author":"C Pomares-Puig","year":"2023","unstructured":"Pomares-Puig, C., S\u00e1nchez-Garc\u00e9s, M. A. & Jorba-Garc\u00eda, A. Dynamic and static computer-assisted implant surgery for completely edentulous patients. a proof of a concept. J. Dent. 130, 104443 (2023).","journal-title":"J. Dent."},{"key":"1178_CR57","doi-asserted-by":"publisher","first-page":"398","DOI":"10.4103\/jisp.jisp_92_20","volume":"24","author":"G Kalaivani","year":"2020","unstructured":"Kalaivani, G., Balaji, V. R., Manikandan, D. & Rohini, G. Expectation and reality of guided implant surgery protocol using computer-assisted static and dynamic navigation system at present scenario: evidence-based literature review. J. Indian Soc. Periodontol. 24, 398\u2013408 (2020).","journal-title":"J. Indian Soc. Periodontol."},{"key":"1178_CR58","doi-asserted-by":"publisher","first-page":"e139","DOI":"10.1016\/j.wneu.2020.10.055","volume":"146","author":"LP Zhou","year":"2021","unstructured":"Zhou, L. P., Zhang, R. J., Sun, Y. W., Zhang, L. & Shen, C. L. Accuracy of pedicle screw placement and four other clinical outcomes of robotic guidance technique versus computer-assisted navigation in thoracolumbar surgery: a meta-analysis. World Neurosurg. 146, e139\u2013e150 (2021).","journal-title":"World Neurosurg."},{"key":"1178_CR59","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1111\/cid.12998","volume":"23","author":"J Abduo","year":"2021","unstructured":"Abduo, J. & Lau, D. Accuracy of static computer-assisted implant placement in long span edentulous area by novice implant clinicians: a cross-sectional in vitro study comparing fully-guided, pilot-guided, and freehand implant placement protocols. Clin. Implant Dent. Relat. Res 23, 361\u2013372 (2021).","journal-title":"Clin. Implant Dent. Relat. Res"},{"key":"1178_CR60","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1111\/jopr.13065","volume":"28","author":"T Tang","year":"2019","unstructured":"Tang, T. et al. Factors that influence direction deviation in freehand implant placement. J. Prosthodont. 28, 511\u2013518 (2019).","journal-title":"J. Prosthodont."},{"key":"1178_CR61","first-page":"709","volume":"19","author":"J Ruppin","year":"2008","unstructured":"Ruppin, J. et al. Evaluation of the accuracy of three different computer-aided surgery systems in dental implantology: optical tracking vs. stereolithographic splint systems. Clin. Oral. Implants Res. 19, 709\u2013716 (2008).","journal-title":"Clin. Oral. Implants Res."},{"key":"1178_CR62","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-16074-w","volume":"12","author":"Y Xiao","year":"2022","unstructured":"Xiao, Y. et al. Construction of a new automatic grading system for jaw bone mineral density level based on deep learning using cone beam computed tomography. Sci. Rep. 12, 12841 (2022).","journal-title":"Sci. Rep."},{"key":"1178_CR63","doi-asserted-by":"publisher","unstructured":"Chen, J. et al. Accuracy of immediate dental implant placement with task-autonomous robotic system and navigation system: an in vitro study. Clin. Oral Implants Res. https:\/\/doi.org\/10.1111\/clr.14104 (2023).","DOI":"10.1111\/clr.14104"},{"key":"1178_CR64","doi-asserted-by":"publisher","first-page":"92","DOI":"10.11607\/jomi.5004","volume":"32","author":"MS Block","year":"2017","unstructured":"Block, M. S., Emery, R. W., Lank, K. & Ryan, J. Implant placement accuracy using dynamic navigation. Int. J. Oral. Maxillofac. Implants 32, 92\u201399 (2017).","journal-title":"Int. J. Oral. Maxillofac. Implants"},{"key":"1178_CR65","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1016\/j.kjms.2017.08.011","volume":"34","author":"TM Sun","year":"2018","unstructured":"Sun, T. M., Lan, T. H., Pan, C. Y. & Lee, H. E. Dental implant navigation system guide the surgery future. Kaohsiung J. Med. Sci. 34, 56\u201364 (2018).","journal-title":"Kaohsiung J. Med. Sci."},{"key":"1178_CR66","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12903-019-0914-2","volume":"19","author":"TM Sun","year":"2019","unstructured":"Sun, T. M., Lee, H. E. & Lan, T. H. The influence of dental experience on a dental implant navigation system. BMC Oral. Health 19, 1\u201311 (2019).","journal-title":"BMC Oral. Health"},{"key":"1178_CR67","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1111\/clr.12414","volume":"26","author":"E Somogyi\u2010Ganss","year":"2015","unstructured":"Somogyi\u2010Ganss, E., Holmes, H. I. & Jokstad, A. Accuracy of a novel prototype dynamic computer\u2010assisted surgery system. Clin. Oral. Implants Res 26, 882\u2013890 (2015).","journal-title":"Clin. Oral. Implants Res"},{"key":"1178_CR68","unstructured":"Worthington, P. Injury to the inferior alveolar nerve during implant placement: A formula for protection of the patient and clinician. Int. J. Oral Maxillofac Implants. 19 (2004)."},{"key":"1178_CR69","doi-asserted-by":"publisher","first-page":"E7","DOI":"10.3171\/2017.2.FOCUS16579","volume":"42","author":"A De Benedictis","year":"2017","unstructured":"De Benedictis, A. et al. Robot-assisted procedures in pediatric neurosurgery. Neurosurg. Focus 42, E7 (2017).","journal-title":"Neurosurg. Focus"},{"key":"1178_CR70","first-page":"499","volume":"25","author":"SA Fatemitabar","year":"2010","unstructured":"Fatemitabar, S. A. & Nikgoo, A. Multichannel computed tomography versus cone-beam computed tomography: linear accuracy of in vitro measurements of the maxilla for implant placement. Int. J. Oral. Maxillofac. Implants 25, 499\u2013505 (2010).","journal-title":"Int. J. Oral. Maxillofac. Implants"},{"key":"1178_CR71","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1111\/clr.12379","volume":"26","author":"T Joda","year":"2015","unstructured":"Joda, T. & Gallucci, G. O. The virtual patient in dental medicine. Clin. Oral. Implants Res. 26, 725\u2013726 (2015).","journal-title":"Clin. Oral. Implants Res."},{"key":"1178_CR72","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/SIH.0000000000000059","volume":"10","author":"S Perry","year":"2015","unstructured":"Perry, S., Bridges, S. M. & Burrow, M. F. A review of the use of simulation in dental education. Simul. Health. 10, 31\u201337 (2015).","journal-title":"Simul. Health."},{"key":"1178_CR73","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1038\/sj.bdj.2015.914","volume":"219","author":"A Dawood","year":"2015","unstructured":"Dawood, A., Marti Marti, B., Sauret-Jackson, V. & Darwood, A. 3D printing in dentistry. Br. Dent. J. 219, 521\u2013529 (2015).","journal-title":"Br. Dent. J."},{"key":"1178_CR74","doi-asserted-by":"publisher","first-page":"103783","DOI":"10.1016\/j.medengphy.2022.103783","volume":"103","author":"K Lan","year":"2022","unstructured":"Lan, K., Tao, B., Wang, F. & Wu, Y. Accuracy evaluation of 3D-printed noninvasive adhesive marker for dynamic navigation implant surgery in a maxillary edentulous model: an in vitro study. Med. Eng. Phys. 103, 103783 (2022).","journal-title":"Med. Eng. Phys."},{"key":"1178_CR75","doi-asserted-by":"publisher","first-page":"104642","DOI":"10.1016\/j.jdent.2023.104642","volume":"137","author":"Z Xu","year":"2023","unstructured":"Xu, Z. et al. Accuracy and efficiency of robotic dental implant surgery with different human-robot interactions: An in vitro study. J. Dent. 137, 104642 (2023).","journal-title":"J. Dent."}],"updated-by":[{"DOI":"10.1038\/s41746-024-01186-6","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T00:00:00Z","timestamp":1721001600000}}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01178-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01178-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01178-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,16]],"date-time":"2024-07-16T07:02:30Z","timestamp":1721113350000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01178-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,6]]},"references-count":75,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["1178"],"URL":"https:\/\/doi.org\/10.1038\/s41746-024-01178-6","relation":{"correction":[{"id-type":"doi","id":"10.1038\/s41746-024-01186-6","asserted-by":"object"}]},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,6]]},"assertion":[{"value":"11 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2024","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1038\/s41746-024-01186-6","URL":"https:\/\/doi.org\/10.1038\/s41746-024-01186-6","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"182"}}