{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,24]],"date-time":"2026-03-24T21:35:17Z","timestamp":1774388117085,"version":"3.50.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T00:00:00Z","timestamp":1734566400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T00:00:00Z","timestamp":1734566400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Seoul National University Medical Big Data Research Center"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This study evaluated the impact of differing false positive (FP) rates in two computer-aided detection (CADe) systems on the clinical effectiveness of artificial intelligence (AI)-assisted colonoscopy. The primary outcomes were adenoma detection rate (ADR) and adenomas per colonoscopy (APC). The ADR in the control, system A (3.2% FP rate), and system B (0.6% FP rate) groups were 44.3%, 43.4%, and 50.4%, respectively, with system B showing a significantly higher ADR than the control group. The APC for the control, A, and B groups were 0.75, 0.83, and 0.90, respectively, with system B also showing a higher APC than the control. The non-true lesion resection rates were 23.8%, 29.2%, and 21.3%, with system B having the lowest. The system with lower FP rates demonstrated improved ADR and APC without increasing the resection of non-neoplastic lesions. These findings suggest that higher FP rates negatively affect the clinical performance of AI-assisted colonoscopy.<\/jats:p>","DOI":"10.1038\/s41746-024-01334-y","type":"journal-article","created":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T06:58:39Z","timestamp":1734591519000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["A prospective comparison of two computer aided detection systems with different false positive rates in colonoscopy"],"prefix":"10.1038","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8344-7737","authenticated-orcid":false,"given":"Goh Eun","family":"Chung","sequence":"first","affiliation":[]},{"given":"Jooyoung","family":"Lee","sequence":"additional","affiliation":[]},{"given":"Seon Hee","family":"Lim","sequence":"additional","affiliation":[]},{"given":"Hae Yeon","family":"Kang","sequence":"additional","affiliation":[]},{"given":"Jung","family":"Kim","sequence":"additional","affiliation":[]},{"given":"Ji Hyun","family":"Song","sequence":"additional","affiliation":[]},{"given":"Sun Young","family":"Yang","sequence":"additional","affiliation":[]},{"given":"Ji Min","family":"Choi","sequence":"additional","affiliation":[]},{"given":"Ji Yeon","family":"Seo","sequence":"additional","affiliation":[]},{"given":"Jung Ho","family":"Bae","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2024,12,19]]},"reference":[{"key":"1334_CR1","doi-asserted-by":"publisher","first-page":"209","DOI":"10.3322\/caac.21660","volume":"71","author":"S Hyuna","year":"2021","unstructured":"Hyuna, S. et al. Global Cancer Statistics 2020: GLOBOCAN Estimates of Incidence and Mortality Worldwide for 36 Cancers in 185 Countries. Ca. Cancer J. Clin. 71, 209\u2013249 (2021).","journal-title":"Ca. Cancer J. Clin."},{"key":"1334_CR2","doi-asserted-by":"publisher","first-page":"1637","DOI":"10.1136\/gutjnl-2014-309086","volume":"64","author":"EH Schreuders","year":"2015","unstructured":"Schreuders, E. H. et al. Colorectal cancer screening: a global overview of existing programmes. Gut 64, 1637\u20131649 (2015).","journal-title":"Gut"},{"key":"1334_CR3","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1053\/j.gastro.2019.01.260","volume":"156","author":"Z Shengbing","year":"2019","unstructured":"Shengbing, Z. et al. Magnitude, risk factors, and factors associated with adenoma miss rate of tandem colonoscopy: a systematic review and meta-analysis. Gastroenterology 156, 1661\u20131674 (2019).","journal-title":"Gastroenterology"},{"key":"1334_CR4","doi-asserted-by":"publisher","first-page":"1016","DOI":"10.1038\/ajg.2017.174","volume":"112","author":"DK Rex","year":"2017","unstructured":"Rex, D. K. et al. Colorectal cancer screening: recommendations for physicians and patients from the U.S. multi-society task force on colorectal cancer. Am. J. Gastroenterol. 112, 1016\u20131030 (2017).","journal-title":"Am. J. Gastroenterol."},{"key":"1334_CR5","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1111\/jgh.16059","volume":"38","author":"S Sagar","year":"2023","unstructured":"Sagar, S. et al. Effect of computer-aided colonoscopy on adenoma miss rates and polyp detection: a systematic review and meta-analysis. J. Gastroenterol. Hepatol. 38, 162\u2013176 (2023).","journal-title":"J. Gastroenterol. Hepatol."},{"key":"1334_CR6","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/j.gie.2022.09.029","volume":"97","author":"AZ Gimeno-Garc\u00eda","year":"2023","unstructured":"Gimeno-Garc\u00eda, A. Z. et al. Usefulness of a novel computer-aided detection system for colorectal neoplasia: a randomized controlled trial. Gastrointest. Endosc. 97, 528\u2013536 (2023).","journal-title":"Gastrointest. Endosc."},{"key":"1334_CR7","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/S2468-1253(21)00215-6","volume":"6","author":"S Marco","year":"2021","unstructured":"Marco, S. et al. Computer-aided detection versus advanced imaging for detection of colorectal neoplasia: a systematic review and network meta-analysis. Lancet Gastroenterol. Hepatol. 6, 793\u2013802 (2021).","journal-title":"Lancet Gastroenterol. Hepatol."},{"key":"1334_CR8","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/j.gie.2020.06.059","volume":"93","author":"H Cesare","year":"2021","unstructured":"Cesare, H. et al. Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis. Gastrointest. Endosc. 93, 77\u201385 (2021).","journal-title":"Gastrointest. Endosc."},{"key":"1334_CR9","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1053\/j.gastro.2020.04.062","volume":"159","author":"R Alessandro","year":"2020","unstructured":"Alessandro, R. et al. Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial. Gastroenterology 159, 512\u2013520 (2020).","journal-title":"Gastroenterology"},{"key":"1334_CR10","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/j.igie.2023.05.001","volume":"2","author":"MG Shiha","year":"2023","unstructured":"Shiha, M. G. et al. Artificial intelligence\u2013assisted colonoscopy for adenoma and polyp detection: an updated systematic review and meta-analysis. iGIE 2, 333\u2013343 (2023).","journal-title":"iGIE"},{"key":"1334_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.eclinm.2023.102341","volume":"66","author":"L Shenghan","year":"2023","unstructured":"Shenghan, L. et al. Artificial intelligence for colorectal neoplasia detection during colonoscopy: a systematic review and meta-analysis of randomized clinical trials. eClinicalMedicine 66, 102341 (2023).","journal-title":"eClinicalMedicine"},{"key":"1334_CR12","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1016\/j.cgh.2023.11.029","volume":"22","author":"HK Patel","year":"2024","unstructured":"Patel, H. K. et al. Lack of effectiveness of computer aided detection for colorectal neoplasia: a systematic review and meta-analysis of nonrandomized studies. Clin. Gastroenterol. Hepatol. 22, 971\u2013980 (2024).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"1334_CR13","doi-asserted-by":"publisher","first-page":"900","DOI":"10.1016\/j.gie.2020.06.021","volume":"92","author":"H Cesare","year":"2020","unstructured":"Cesare, H. et al. Computer-aided detection-assisted colonoscopy: classification and relevance of false positives. Gastrointest. Endosc. 92, 900\u2013904 (2020).","journal-title":"Gastrointest. Endosc."},{"key":"1334_CR14","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.gie.2023.02.016","volume":"98","author":"N Fredy","year":"2023","unstructured":"Fredy, N. et al. Performance and attitudes toward real-time computer-aided polyp detection during colonoscopy in a large tertiary referral center in the United States. Gastrointest. Endosc. 98, 100\u2013109 (2023).","journal-title":"Gastrointest. Endosc."},{"key":"1334_CR15","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1055\/a-1306-7590","volume":"53","author":"OF Ahmad","year":"2021","unstructured":"Ahmad, O. F. et al. Establishing key research questions for the implementation of artificial intelligence in colonoscopy: a modified Delphi method. Endoscopy 53, 893\u2013901 (2021).","journal-title":"Endoscopy"},{"key":"1334_CR16","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-022-10597-y","volume":"12","author":"SY Quan","year":"2022","unstructured":"Quan, S. Y. et al. Clinical evaluation of a real-time artificial intelligence-based polyp detection system: a US multi-center pilot study. Sci. Rep. 12, 6598 (2022).","journal-title":"Sci. Rep."},{"key":"1334_CR17","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.3390\/diagnostics11061113","volume":"11","author":"H Yu-His","year":"2021","unstructured":"Yu-His, H. et al. Computer-aided detection false positives in colonoscopy. Diagnostics (Basel) 11, 1113 (2021).","journal-title":"Diagnostics (Basel)"},{"key":"1334_CR18","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1055\/a-1302-2942","volume":"53","author":"EA Holzwanger","year":"2021","unstructured":"Holzwanger, E. A. et al. Benchmarking definitions of false-positive alerts during computer-aided polyp detection in colonoscopy. Endoscopy 53, 937\u2013940 (2021).","journal-title":"Endoscopy"},{"key":"1334_CR19","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1055\/a-2147-0571","volume":"56","author":"T Joel","year":"2024","unstructured":"Joel, T. et al. Direct comparison of multiple computer-aided polyp detection systems. Endoscopy 56, 63\u201369 (2024).","journal-title":"Endoscopy"},{"key":"1334_CR20","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1016\/j.gie.2021.12.031","volume":"95","author":"S Marco","year":"2022","unstructured":"Marco, S. et al. Comparing the number and relevance of false activations between 2 artificial intelligence computer-aided detection systems: the NOISE study. Gastrointest. Endosc. 95, 975\u2013981 (2022).","journal-title":"Gastrointest. Endosc."},{"key":"1334_CR21","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/j.gie.2022.10.016","volume":"97","author":"P Sravanthi","year":"2023","unstructured":"Sravanthi, P. et al. Framework and metrics for the clinical use and implementation of artificial intelligence algorithms into endoscopy practice: recommendations from the American Society for Gastrointestinal Endoscopy Artificial Intelligence Task Force. Gastrointest. Endosc. 97, 815\u2013824 (2023).","journal-title":"Gastrointest. Endosc."},{"key":"1334_CR22","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1038\/381520a0","volume":"381","author":"T Simon","year":"1996","unstructured":"Simon, T., Denis, F. & Catherine, M. Speed of processing in the human visual system. Nature 381, 520\u2013522 (1996).","journal-title":"Nature"},{"key":"1334_CR23","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1213\/ANE.0b013e3181fcc504","volume":"112","author":"S Felix","year":"2011","unstructured":"Felix, S. et al. The wolf is crying in the operating room: patient monitor and anesthesia workstation alarming patterns during cardiac surgery. Anesth. Analg. 112, 78\u201383 (2011).","journal-title":"Anesth. Analg."},{"key":"1334_CR24","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1111\/risa.12262","volume":"35","author":"JT Ripberger","year":"2015","unstructured":"Ripberger, J. T. et al. False alarms and missed events: the impact and origins of perceived inaccuracy in tornado warning systems. Risk Anal. 35, 44\u201356 (2015).","journal-title":"Risk Anal."},{"key":"1334_CR25","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1097\/00003246-199406000-00017","volume":"22","author":"L Stephen","year":"1994","unstructured":"Stephen, L. Crying wolf: false alarms in a pediatric intensive care unit. Crit. Care Med. 22, 981\u2013985 (1994).","journal-title":"Crit. Care Med."},{"key":"1334_CR26","doi-asserted-by":"publisher","first-page":"793","DOI":"10.3233\/WOR-220466","volume":"76","author":"K Azize","year":"2023","unstructured":"Azize, K. et al. Alarm fatigue among nurses working in intensive care and other inpatient clinics. Work 76, 793\u2013801 (2023).","journal-title":"Work"},{"key":"1334_CR27","doi-asserted-by":"publisher","first-page":"268","DOI":"10.2345\/0899-8205-46.4.268","volume":"46","author":"C Maria","year":"2012","unstructured":"Maria, C. Monitor alarm fatigue: an integrative review. Biomed. Instrum. Technol. 46, 268\u2013277 (2012).","journal-title":"Biomed. Instrum. Technol."},{"key":"1334_CR28","doi-asserted-by":"publisher","first-page":"1546","DOI":"10.1213\/ane.0b013e31819bdfbb","volume":"108","author":"M G\u00f6rges","year":"2009","unstructured":"G\u00f6rges, M., Markewitz, B. A. & Westenskow, D. R. Improving alarm performance in the medical intensive care unit using delays and clinical context. Anesth. Analg. 108, 1546\u20131552 (2009).","journal-title":"Anesth. Analg."},{"key":"1334_CR29","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1002\/jhm.2331","volume":"10","author":"CP Bonafide","year":"2015","unstructured":"Bonafide, C. P. et al. Association between exposure to nonactionable physiologic monitor alarms and response time in a children\u2019s hospital. J. Hosp. Med. 10, 345\u2013351 (2015).","journal-title":"J. Hosp. Med."},{"key":"1334_CR30","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1097\/ACO.0000000000000260","volume":"28","author":"KJ Ruskin","year":"2015","unstructured":"Ruskin, K. J. & Hueske-Kraus, D. Alarm fatigue: impacts on patient safety. Curr. Opin. Anaesthesiol. 28, 685\u2013690 (2015).","journal-title":"Curr. Opin. Anaesthesiol."},{"key":"1334_CR31","doi-asserted-by":"publisher","first-page":"1871","DOI":"10.14309\/ajg.0000000000001970","volume":"117","author":"L Idan","year":"2022","unstructured":"Idan, L., Liora, B., Eyal, K., Shomron, B.-H. & Uri, K. Artificial intelligence-aided colonoscopy does not increase adenoma detection rate in routine clinical practice. Am. J. Gastroenterol. 117, 1871\u20131873 (2022).","journal-title":"Am. J. Gastroenterol."},{"key":"1334_CR32","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1053\/j.gastro.2022.05.028","volume":"163","author":"S Aasma","year":"2022","unstructured":"Aasma, S. et al. Computer-aided detection improves adenomas per colonoscopy for screening and surveillance colonoscopy: a randomized trial. Gastroenterology 163, 732\u2013741 (2022).","journal-title":"Gastroenterology"},{"key":"1334_CR33","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1053\/j.gastro.2022.12.004","volume":"164","author":"L Uri","year":"2023","unstructured":"Uri, L. et al. Computer-aided detection of polyps does not improve colonoscopist performance in a pragmatic implementation trial. Gastroenterology 164, 481\u2013483 (2023).","journal-title":"Gastroenterology"},{"key":"1334_CR34","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-04247-y","volume":"12","author":"Y Dan","year":"2022","unstructured":"Dan, Y. et al. Colonoscopic image synthesis with generative adversarial network for enhanced detection of sessile serrated lesions using convolutional neural network. Sci. Rep. 12, 261 (2022).","journal-title":"Sci. Rep."},{"key":"1334_CR35","doi-asserted-by":"publisher","first-page":"857","DOI":"10.5009\/gnl240068","volume":"18","author":"L Jooyoung","year":"2024","unstructured":"Jooyoung, L. et al. Impact of user\u2019s background knowledge and polyp characteristics in colonoscopy with computer-aided detection. Gut Liver 18, 857\u2013866 (2024).","journal-title":"Gut Liver"},{"key":"1334_CR36","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1016\/j.gie.2008.05.057","volume":"69","author":"EJ Lai","year":"2009","unstructured":"Lai, E. J. et al. The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research. Gastrointest. Endosc. 69, 620\u2013625 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"1334_CR37","doi-asserted-by":"publisher","first-page":"2479","DOI":"10.1016\/j.cgh.2019.02.019","volume":"17","author":"JH Bae","year":"2019","unstructured":"Bae, J. H. et al. Improved real-time optical diagnosis of colorectal polyps following a comprehensive training program. Clin. Gastroenterol. Hepatol. 17, 2479\u20132488 (2019).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"1334_CR38","doi-asserted-by":"publisher","first-page":"2169","DOI":"10.1053\/j.gastro.2020.02.036","volume":"158","author":"EH Jin","year":"2020","unstructured":"Jin, E. H. et al. Improved accuracy in optical diagnosis of colorectal polyps using convolutional neural networks with visual explanations. Gastroenterology 158, 2169\u20132179 (2020).","journal-title":"Gastroenterology"},{"key":"1334_CR39","doi-asserted-by":"crossref","unstructured":"The Paris endoscopic classification of superficial neoplastic lesions: esophagus, stomach, and colon: November 30 to December 1, 2002. Gastrointest. Endosc. 58:S3-S43 (2003).","DOI":"10.1016\/S0016-5107(03)02159-X"}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01334-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01334-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01334-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,19]],"date-time":"2024-12-19T07:03:00Z","timestamp":1734591780000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-024-01334-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,19]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["1334"],"URL":"https:\/\/doi.org\/10.1038\/s41746-024-01334-y","relation":{},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,19]]},"assertion":[{"value":"15 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 December 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"J.H.B. holds equity in AINEX Corporation. The remining authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"366"}}