{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T00:33:20Z","timestamp":1792974800207,"version":"4.5.0"},"reference-count":56,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T00:00:00Z","timestamp":1783036800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T00:00:00Z","timestamp":1792972800000},"content-version":"vor","delay-in-days":115,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"National Natural Science Foundation of China","award":["No. 62102008"],"award-info":[{"award-number":["No. 62102008"]}],"id":[{"id":"https:\/\/ror.org\/01h0zpd94","id-type":"ROR","asserted-by":"crossref"}]},{"name":"Ministry of Science and Technology of China STI2030-Major Projects","award":["No. 2021ZD0201900, No. 2021ZD0201902"],"award-info":[{"award-number":["No. 2021ZD0201900, No. 2021ZD0201902"]}],"id":[{"id":"https:\/\/ror.org\/02kv4zf79","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["npj Digit. Med."],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Sleep profoundly impacts health, yet current gold-standard Polysomnography (PSG) is constrained by cost, discomfort, and limited scalability for longitudinal monitoring. Ballistocardiography (BCG) offers a non-invasive and user-friendly alternative but often lacks the precision needed for reliable real-world applications. To address this gap, we propose BCGNet, a two-stage transfer learning model that is first pre-trained on 580,865\u2009h of PSG and then fine-tuned and validated on 15,081\u2009h of BCG (total 595,946\u2009h of recordings). Across multiple validation cohorts, BCGNet achieves strong performance in 4-class sleep staging (F1: 0.710\u22120.817), Apnea-Hypopnea Index (AHI3%) estimation (Pearson\u2019s\n                    <jats:italic>r<\/jats:italic>\n                    \u2009&gt;\u20090.95), and robust quantification of sleep continuity and architecture (ICC and Pearson\u2019s\n                    <jats:italic>r<\/jats:italic>\n                    generally &gt;0.8). Notably, BCGNet maintains strong performance even on short daytime naps and demonstrates excellent generalizability across diverse external datasets. Deployed as a portable, contactless sleep tracking mat, BCGNet represents a major step towards scalable, user-friendly solutions for longitudinal home sleep monitoring, with important implications for population screening and personalized sleep medicine.\n                  <\/jats:p>","DOI":"10.1038\/s41746-026-02885-y","type":"journal-article","created":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T03:34:04Z","timestamp":1783049644000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["BCGNet: an AI model trained on 600 K hours of sleep data for a novel under-pillow contactless monitoring device"],"prefix":"10.1038","volume":"9","author":[{"given":"Shigeng","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuesong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weijun","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Lei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuxuan","family":"Shan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zengrui","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunhan","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yichen","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xing","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dongsheng","family":"Lv","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanru","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shirui","family":"Pan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ambrose","family":"Chiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. Brandon","family":"Westover","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shenda","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shankai","family":"Yin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun-feng","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongliang","family":"Yi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangdong","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue","family":"Leng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,3]]},"reference":[{"key":"2885_CR1","doi-asserted-by":"publisher","first-page":"e820","DOI":"10.1016\/S2468-2667(23)00182-2","volume":"8","author":"DC Lim","year":"2023","unstructured":"Lim, D. C. et al. The need to promote sleep health in public health agendas across the globe. Lancet Public Health 8, e820\u2013e826 (2023).","journal-title":"Lancet Public Health"},{"key":"2885_CR2","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1146\/annurev-psych-010213-115205","volume":"66","author":"MR Irwin","year":"2015","unstructured":"Irwin, M. R. Why sleep is important for health: a psychoneuroimmunology perspective. Annu. Rev. Psychol. 66, 143\u2013172 (2015).","journal-title":"Annu. Rev. Psychol."},{"key":"2885_CR3","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1164\/rccm.201504-0767ST","volume":"191","author":"S Mukherjee","year":"2015","unstructured":"Mukherjee, S. et al. An official American Thoracic Society statement: the importance of healthy sleep. recommendations and future priorities. Am. J. Respir. Crit. Care Med. 191, 1450\u20131458 (2015).","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2885_CR4","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S1474-4422(18)30461-7","volume":"18","author":"Y Leng","year":"2019","unstructured":"Leng, Y., Musiek, E. S., Hu, K., Cappuccio, F. P. & Yaffe, K. Association between circadian rhythms and neurodegenerative diseases. Lancet Neurol. 18, 307\u2013318 (2019).","journal-title":"Lancet Neurol."},{"key":"2885_CR5","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/B978-0-444-64032-1.00025-4","volume":"160","author":"JV Rundo","year":"2019","unstructured":"Rundo, J. V. & Downey, R. III Polysomnography. Handb. Clin. Neurol. 160, 381\u2013392 (2019).","journal-title":"Handb. Clin. Neurol."},{"key":"2885_CR6","doi-asserted-by":"publisher","first-page":"285","DOI":"10.3233\/THC-1997-5403","volume":"5","author":"KE Bloch","year":"1997","unstructured":"Bloch, K. E. Polysomnography: a systematic review. Technol. Health Care 5, 285\u2013305 (1997).","journal-title":"Technol. Health Care"},{"key":"2885_CR7","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1016\/S2213-2600(19)30057-8","volume":"7","author":"MI Boulos","year":"2019","unstructured":"Boulos, M. I. et al. Normal polysomnography parameters in healthy adults: a systematic review and meta-analysis. Lancet Respir. Med. 7, 533\u2013543 (2019).","journal-title":"Lancet Respir. Med."},{"key":"2885_CR8","doi-asserted-by":"publisher","first-page":"814","DOI":"10.1164\/ajrccm.162.3.9908002","volume":"162","author":"F Portier","year":"2000","unstructured":"Portier, F. et al. Evaluation of home versus laboratory polysomnography in the diagnosis of sleep apnea syndrome. Am. J. Respir. Crit. Care Med. 162, 814\u2013818 (2000).","journal-title":"Am. J. Respir. Crit. Care Med."},{"key":"2885_CR9","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.5664\/jcsm.7278","volume":"14","author":"T Miettinen","year":"2018","unstructured":"Miettinen, T. et al. Home polysomnography reveals a first-night effect in patients with low sleep bruxism activity. J. Clin. Sleep Med. 14, 1377\u20131386 (2018).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR10","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.5664\/jcsm.9300","volume":"17","author":"S Tschopp","year":"2021","unstructured":"Tschopp, S., Wimmer, W., Caversaccio, M., Borner, U. & Tschopp, K. Night-to-night variability in obstructive sleep apnea using peripheral arterial tonometry: a case for multiple night testing. J. Clin. Sleep Med. 17, 1751\u20131758 (2021).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR11","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.5664\/jcsm.9240","volume":"17","author":"SM Caples","year":"2021","unstructured":"Caples, S. M., Anderson, W. M., Calero, K., Howell, M. & Hashmi, S. D. Use of polysomnography and home sleep apnea tests for the longitudinal management of obstructive sleep apnea in adults: an American Academy of Sleep Medicine clinical guidance statement. J. Clin. Sleep Med. 17, 1287\u20131293 (2021).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR12","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1038\/s41746-024-01016-9","volume":"7","author":"V Birrer","year":"2024","unstructured":"Birrer, V., Elgendi, M., Lambercy, O. & Menon, C. Evaluating reliability in wearable devices for sleep staging. NPJ Digit. Med. 7, 74 (2024).","journal-title":"NPJ Digit. Med."},{"key":"2885_CR13","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s13755-019-0071-7","volume":"7","author":"I Sadek","year":"2019","unstructured":"Sadek, I., Biswas, J. & Abdulrazak, B. Ballistocardiogram signal processing: a review. Health Inf. Sci. Syst. 7, 10 (2019).","journal-title":"Health Inf. Sci. Syst."},{"key":"2885_CR14","doi-asserted-by":"publisher","DOI":"10.1038\/srep31297","volume":"6","author":"C-S Kim","year":"2016","unstructured":"Kim, C.-S. et al. Ballistocardiogram: mechanism and potential for unobtrusive cardiovascular health monitoring. Sci. Rep. 6, 31297 (2016).","journal-title":"Sci. Rep."},{"key":"2885_CR15","doi-asserted-by":"crossref","unstructured":"Yu, B., Chen, Y., Cai, D. & Zhang, H. A proof-of-concept study on noncontact BCG-based cardiac monitoring for in-patients with sleep apnea syndrome using piezoelectric ceramics. IEEE Trans. Instrum. Meas. 74, 4000810 (2025).","DOI":"10.1109\/TIM.2024.3522412"},{"key":"2885_CR16","doi-asserted-by":"crossref","unstructured":"Paalasmaa, J., Waris, M., Toivonen, H., Lepp\u00e4korpi, L. & Partinen, M. Unobtrusive Online Monitoring of Sleep at Home 3784\u20133788 (IEEE, 2012).","DOI":"10.1109\/EMBC.2012.6346791"},{"key":"2885_CR17","doi-asserted-by":"publisher","first-page":"e18297","DOI":"10.2196\/18297","volume":"22","author":"I Sadek","year":"2020","unstructured":"Sadek, I., Heng, T. T. S., Seet, E. & Abdulrazak, B. A new approach for detecting sleep apnea using a contactless bed sensor: comparison study. J. Med. Internet Res. 22, e18297 (2020).","journal-title":"J. Med. Internet Res."},{"key":"2885_CR18","doi-asserted-by":"crossref","unstructured":"Yi, R., Enayati, M., Keller, J. M., Popescu, M. & Skubic, M. Non-invasive In-home Sleep Stage Classification Using a Ballistocardiography Bed Sensor, 1\u20134 (IEEE, 2019).","DOI":"10.1109\/BHI.2019.8834535"},{"key":"2885_CR19","doi-asserted-by":"crossref","unstructured":"Migliorini, M. et al. Automatic Sleep Staging Based on Ballistocardiographic Signals Recorded Through Bed Sensors, 3273\u20133276 (IEEE, 2010).","DOI":"10.1109\/IEMBS.2010.5627217"},{"key":"2885_CR20","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1007\/s11517-010-0722-y","volume":"49","author":"RM Wiard","year":"2011","unstructured":"Wiard, R. M. et al. Automatic detection of motion artifacts in the ballistocardiogram measured on a modified bathroom scale. Med. Biol. Eng. Comput. 49, 213\u2013220 (2011).","journal-title":"Med. Biol. Eng. Comput."},{"key":"2885_CR21","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1016\/j.neuroimage.2010.01.010","volume":"50","author":"K Vanderperren","year":"2010","unstructured":"Vanderperren, K. et al. Removal of BCG artifacts from EEG recordings inside the MR scanner: a comparison of methodological and validation-related aspects. Neuroimage 50, 920\u2013934 (2010).","journal-title":"Neuroimage"},{"key":"2885_CR22","doi-asserted-by":"publisher","first-page":"5688","DOI":"10.3390\/s20195688","volume":"20","author":"Y Mitsukura","year":"2020","unstructured":"Mitsukura, Y., Sumali, B., Nagura, M., Fukunaga, K. & Yasui, M. Sleep stage estimation from bed leg ballistocardiogram sensors. Sensors 20, 5688 (2020).","journal-title":"Sensors"},{"key":"2885_CR23","doi-asserted-by":"publisher","first-page":"e0175351","DOI":"10.1371\/journal.pone.0175351","volume":"12","author":"Z Wang","year":"2017","unstructured":"Wang, Z. et al. Assessing the severity of sleep apnea syndrome based on ballistocardiogram. PLoS ONE 12, e0175351 (2017).","journal-title":"PLoS ONE"},{"key":"2885_CR24","doi-asserted-by":"crossref","unstructured":"Berry, R. B. et al. AASM scoring manual updates for 2017 (version 2.4) (2017).","DOI":"10.5664\/jcsm.6576"},{"key":"2885_CR25","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.5664\/jcsm.9168","volume":"17","author":"P Edouard","year":"2021","unstructured":"Edouard, P. et al. Validation of the Withings sleep analyzer, an under-the-mattress device for the detection of moderate-severe sleep apnea syndrome. J. Clin. Sleep Med. 17, 1217\u20131227 (2021).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR26","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1016\/j.sleep.2022.04.010","volume":"96","author":"F Ding","year":"2022","unstructured":"Ding, F. et al. Polysomnographic validation of an under-mattress monitoring device in estimating sleep architecture and obstructive sleep apnea in adults. Sleep Med. 96, 20\u201327 (2022).","journal-title":"Sleep Med."},{"key":"2885_CR27","doi-asserted-by":"crossref","unstructured":"He, K., Zhang, X., Ren, S. & Sun, J. Deep residual learning for image recognition. In Proc. IEEE Conference on Computer Vision and Pattern Recognition (CVPR) 770\u2013778 (2016).","DOI":"10.1109\/CVPR.2016.90"},{"key":"2885_CR28","doi-asserted-by":"publisher","first-page":"127063","DOI":"10.1016\/j.neucom.2023.127063","volume":"568","author":"J Su","year":"2024","unstructured":"Su, J. et al. Roformer: enhanced transformer with rotary position embedding. Neurocomputing 568, 127063 (2024).","journal-title":"Neurocomputing"},{"key":"2885_CR29","first-page":"1","volume":"8","author":"S Li","year":"2024","unstructured":"Li, S. et al. SleepNetZero: Zero-burden zero-shot reliable sleep staging with neural networks based on ballistocardiograms. Proc. ACM Interact. Mob. Wearable Ubiquitous Technol. 8, 1\u201325 (2024).","journal-title":"Proc. ACM Interact. Mob. Wearable Ubiquitous Technol."},{"key":"2885_CR30","doi-asserted-by":"crossref","unstructured":"Rao, S., Ali, A. E. & Cesar, P. Deepsleep: a ballistocardiographic deep learning approach for classifying sleep stages. In Proc. 2019 ACM International Joint Conference on Pervasive and Ubiquitous Computing and Proceedings of the 2019 ACM International Symposium on Wearable Computers 187\u2013190 (ACM, 2019).","DOI":"10.1145\/3341162.3343758"},{"key":"2885_CR31","doi-asserted-by":"publisher","first-page":"zsaa098","DOI":"10.1093\/sleep\/zsaa098","volume":"43","author":"H Korkalainen","year":"2020","unstructured":"Korkalainen, H. et al. Deep learning enables sleep staging from photoplethysmogram for patients with suspected sleep apnea. Sleep 43, zsaa098 (2020).","journal-title":"Sleep"},{"key":"2885_CR32","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1038\/s41746-021-00510-8","volume":"4","author":"M Radha","year":"2021","unstructured":"Radha, M. et al. A deep transfer learning approach for wearable sleep stage classification with photoplethysmography. npj Digit. Med. 4, 135 (2021).","journal-title":"npj Digit. Med."},{"key":"2885_CR33","doi-asserted-by":"publisher","first-page":"zsae187","DOI":"10.1093\/sleep\/zsae187","volume":"48","author":"H He","year":"2025","unstructured":"He, H. et al. What radio waves tell us about sleep!. Sleep 48, zsae187 (2025).","journal-title":"Sleep"},{"key":"2885_CR34","doi-asserted-by":"publisher","first-page":"zsz306","DOI":"10.1093\/sleep\/zsz306","volume":"43","author":"H Sun","year":"2020","unstructured":"Sun, H. et al. Sleep staging from electrocardiography and respiration with deep learning. Sleep 43, zsz306 (2020).","journal-title":"Sleep"},{"key":"2885_CR35","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1038\/s41746-020-0291-x","volume":"3","author":"N Sridhar","year":"2020","unstructured":"Sridhar, N. et al. Deep learning for automated sleep staging using instantaneous heart rate. npj Digit. Med. 3, 106 (2020).","journal-title":"npj Digit. Med."},{"key":"2885_CR36","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-024-01252-w","volume":"23","author":"M-H Liu","year":"2024","unstructured":"Liu, M.-H. et al. EfficientNet-based machine learning architecture for sleep apnea identification in clinical single-lead ECG signal data sets. BioMed. Eng. Online 23, 57 (2024).","journal-title":"BioMed. Eng. Online"},{"key":"2885_CR37","doi-asserted-by":"crossref","unstructured":"Zhang, Y. et al. Deep learning for obstructive sleep apnea detection and severity assessment: a multimodal signals fusion multiscale transformer model. Nat. Sci. Sleep 17, 1\u201315 (2025).","DOI":"10.2147\/NSS.S492806"},{"key":"2885_CR38","doi-asserted-by":"publisher","first-page":"1643","DOI":"10.5664\/jcsm.10644","volume":"19","author":"JR Raphelson","year":"2023","unstructured":"Raphelson, J. R. et al. Evaluation of a novel device to assess obstructive sleep apnea and body position. J. Clin. Sleep Med. 19, 1643\u20131649 (2023).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR39","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1038\/s41746-024-01127-3","volume":"7","author":"L Goetz","year":"2024","unstructured":"Goetz, L., Seedat, N., Vandersluis, R. & van der Schaar, M. Generalization\u2014a key challenge for responsible ai in patient-facing clinical applications. NPJ Digit. Med. 7, 126 (2024).","journal-title":"NPJ Digit. Med."},{"key":"2885_CR40","doi-asserted-by":"publisher","first-page":"E1391","DOI":"10.1503\/cmaj.202066","volume":"193","author":"JP Cohen","year":"2021","unstructured":"Cohen, J. P. et al. Problems in the deployment of machine-learned models in health care. Cmaj 193, E1391\u2013E1394 (2021).","journal-title":"Cmaj"},{"key":"2885_CR41","doi-asserted-by":"crossref","unstructured":"Chen, X. et al. Non-contact detection of sleep apnea using multi-timescale cardiopulmonary features. In Proc. 2024 International Conference on Sports Technology and Performance Analysis 439\u2013446 (ACM, 2024).","DOI":"10.1145\/3723936.3724005"},{"key":"2885_CR42","doi-asserted-by":"publisher","first-page":"571","DOI":"10.3390\/jcm13020571","volume":"13","author":"J Sanchez Gomez","year":"2024","unstructured":"Sanchez Gomez, J., Pramono, R. X. A., Imtiaz, S. A., Rodriguez-Villegas, E. & Valido Morales A. Validation of a wearable medical device for automatic diagnosis of OSA against standard PSG. J. Clin. Med. 13, 571 (2024).","journal-title":"J. Clin. Med."},{"key":"2885_CR43","doi-asserted-by":"publisher","first-page":"2703","DOI":"10.5664\/jcsm.10194","volume":"18","author":"C Davies","year":"2022","unstructured":"Davies, C. et al. A single-arm, open-label, multicenter, and comparative study of the ANNE sleep system vs polysomnography to diagnose obstructive sleep apnea. J. Clin. Sleep Med. 18, 2703\u20132712 (2022).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR44","doi-asserted-by":"crossref","unstructured":"Jaworski, D. & Park, E. J. Nonlinear heart rate variability analysis for sleep stage classification using integration of ballistocardiogram and apple watch. Nat. Sci. Sleep 16, 1075\u20131090 (2024).","DOI":"10.2147\/NSS.S464944"},{"key":"2885_CR45","doi-asserted-by":"publisher","first-page":"3844","DOI":"10.1109\/JBHI.2021.3072644","volume":"25","author":"HB Kwon","year":"2021","unstructured":"Kwon, H. B. et al. Attention-based LSTM for non-contact sleep stage classification using IR-UWB radar. IEEE J. Biomed. Health Inf. 25, 3844\u20133853 (2021).","journal-title":"IEEE J. Biomed. Health Inf."},{"key":"2885_CR46","doi-asserted-by":"publisher","first-page":"974192","DOI":"10.3389\/fnins.2022.974192","volume":"16","author":"N Pini","year":"2022","unstructured":"Pini, N. et al. An automated heart rate-based algorithm for sleep stage classification: validation using conventional polysomnography and an innovative wearable electrocardiogram device. Front. Neurosci. 16, 974192 (2022).","journal-title":"Front. Neurosci."},{"key":"2885_CR47","doi-asserted-by":"publisher","first-page":"e213403","DOI":"10.1212\/WNL.0000000000213403","volume":"104","author":"S Milton","year":"2025","unstructured":"Milton, S. et al. Five-year changes in 24-hour sleep-wake activity and dementia risk in oldest old women. Neurology 104, e213403 (2025).","journal-title":"Neurology"},{"key":"2885_CR48","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1002\/alz.12636","volume":"19","author":"P Li","year":"2023","unstructured":"Li, P. et al. Daytime napping and Alzheimer\u2019s dementia: a potential bidirectional relationship. Alzheimers Dement. 19, 158\u2013168 (2023).","journal-title":"Alzheimers Dement."},{"key":"2885_CR49","doi-asserted-by":"publisher","first-page":"81","DOI":"10.5664\/jcsm.2350","volume":"9","author":"RS Rosenberg","year":"2013","unstructured":"Rosenberg, R. S. & Van Hout, S. The American Academy of Sleep Medicine inter-scorer reliability program: sleep stage scoring. J. Clin. Sleep Med. 9, 81\u201387 (2013).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR50","doi-asserted-by":"publisher","first-page":"zsaa291","DOI":"10.1093\/sleep\/zsaa291","volume":"44","author":"ED Chinoy","year":"2021","unstructured":"Chinoy, E. D. et al. Performance of seven consumer sleep-tracking devices compared with polysomnography. Sleep 44, zsaa291 (2021).","journal-title":"Sleep"},{"key":"2885_CR51","doi-asserted-by":"publisher","first-page":"193","DOI":"10.5664\/jcsm.9538","volume":"18","author":"YJ Lee","year":"2022","unstructured":"Lee, Y. J., Lee, J. Y., Cho, J. H. & Choi, J. H. Interrater reliability of sleep stage scoring: a meta-analysis. J. Clin. Sleep Med. 18, 193\u2013202 (2022).","journal-title":"J. Clin. Sleep Med."},{"key":"2885_CR52","first-page":"487","volume":"96","author":"W Thomson","year":"1949","unstructured":"Thomson, W. Delay networks having maximally flat frequency characteristics. Proc. IEE-Part III: Radio Commun. Eng 96, 487\u2013490 (1949).","journal-title":"Proc. IEE-Part III: Radio Commun. Eng"},{"key":"2885_CR53","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1088\/0967-3334\/34\/2\/123","volume":"34","author":"C Bru\u00a8ser","year":"2013","unstructured":"Bru\u00a8ser, C., Winter, S. & Leonhardt, S. Robust inter-beat interval estimation in cardiac vibration signals. Physiol. Meas. 34, 123 (2013).","journal-title":"Physiol. Meas."},{"key":"2885_CR54","doi-asserted-by":"crossref","unstructured":"Makowski, D. et al. Neurokit2: a Python toolbox for neurophysiological signal processing. Behav. Res. Methods 53, 1689\u20131696 (2021).","DOI":"10.3758\/s13428-020-01516-y"},{"key":"2885_CR55","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1177\/1094428116681072","volume":"22","author":"S Massaro","year":"2019","unstructured":"Massaro, S. & Pecchia, L. Heart rate variability (HRV) analysis: a methodology for organizational neuroscience. Organ. Res. Methods 22, 354\u2013393 (2019).","journal-title":"Organ. Res. Methods"},{"key":"2885_CR56","doi-asserted-by":"crossref","unstructured":"Lin, T.-Y., Goyal, P., Girshick, R., He, K. & Dollar, P. Focal loss for dense object detection. In Proc. IEEE International Conference on Computer Vision (ICCV) (IEEE, 2017).","DOI":"10.1109\/ICCV.2017.324"}],"container-title":["npj Digital Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-02885-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-02885-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-02885-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T23:41:59Z","timestamp":1792971719000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41746-026-02885-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,3]]},"references-count":56,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2885"],"URL":"https:\/\/doi.org\/10.1038\/s41746-026-02885-y","relation":{},"ISSN":["2398-6352"],"issn-type":[{"value":"2398-6352","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,3]]},"assertion":[{"value":"18 September 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"S.C. and C.S. contributed to this work while serving as research interns. X.C. and Y.W. were employees of Five Seasons Medical at the time this work was conducted. Five Seasons Medical is a commercial company focused on digital health solutions. Patent disclosure: S.C., X.C., Y.W., R.Z., and Y.L. are listed as inventors on a patent application related to the specific aspect of the manuscript (the under-pillow BCG monitoring algorithm): \u2022 Patent Applicant: Five Seasons Medical. \u2022 Name of Inventors: Xuesong Chen, Yupeng Zhang, Yichen Wang, Shigeng Chen, Rui Zhao, and Yue Leng. \u2022 Application Number: CN202511270603.8. \u2022 Status of Application: Pending. M.B.W. is a co-founder, serves as a scientific advisor and consultant to, and has a personal equity interest in Beacon Biosignals. A.C. has received research grants from Belun Technology Company Limited and NightWare for conducting clinical validation trials, but has no other financial conflicts of interest. S.H. serves as a reviewer for the journal but was not involved in the peer review or editorial decision-making process for this manuscript. The remaining authors (W.H., F.L., Z.J., Y.S., X.X., D.L., Y.L., S.P., C.Z., S.Y., C.L., H.Y., X.T.) declare no competing interests.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}],"article-number":"813"}}