{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T18:30:42Z","timestamp":1777487442588,"version":"3.51.4"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2019,6,10]],"date-time":"2019-06-10T00:00:00Z","timestamp":1560124800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2019,6,10]],"date-time":"2019-06-10T00:00:00Z","timestamp":1560124800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nat Mach Intell"],"DOI":"10.1038\/s42256-019-0057-9","type":"journal-article","created":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T16:04:21Z","timestamp":1560269061000},"page":"269-276","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":373,"title":["Competitive performance of a modularized deep neural network compared to commercial algorithms for low-dose CT image reconstruction"],"prefix":"10.1038","volume":"1","author":[{"given":"Hongming","family":"Shan","sequence":"first","affiliation":[]},{"given":"Atul","family":"Padole","sequence":"additional","affiliation":[]},{"given":"Fatemeh","family":"Homayounieh","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5664-9499","authenticated-orcid":false,"given":"Uwe","family":"Kruger","sequence":"additional","affiliation":[]},{"given":"Ruhani Doda","family":"Khera","sequence":"additional","affiliation":[]},{"given":"Chayanin","family":"Nitiwarangkul","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9938-7476","authenticated-orcid":false,"given":"Mannudeep K.","family":"Kalra","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2656-7705","authenticated-orcid":false,"given":"Ge","family":"Wang","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,6,10]]},"reference":[{"key":"57_CR1","doi-asserted-by":"publisher","first-page":"8914","DOI":"10.1109\/ACCESS.2016.2624938","volume":"4","author":"G Wang","year":"2016","unstructured":"Wang, G. A perspective on deep imaging. IEEE Access 4, 8914\u20138924 (2016).","journal-title":"IEEE Access"},{"key":"57_CR2","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1109\/TMI.2018.2833635","volume":"37","author":"G Wang","year":"2018","unstructured":"Wang, G., Ye, J. C., Mueller, K. & Fessler, J. A. Image reconstruction is a new frontier of machine learning. IEEE Trans. Med. Imaging 37, 1289\u20131296 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR3","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1038\/nature25988","volume":"555","author":"B Zhu","year":"2018","unstructured":"Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R. & Rosen, M. S. Image reconstruction by domain-transform manifold learning. Nature 555, 487\u2013492 (2018).","journal-title":"Nature"},{"key":"57_CR4","doi-asserted-by":"publisher","first-page":"2277","DOI":"10.1056\/NEJMra072149","volume":"357","author":"DJ Brenner","year":"2007","unstructured":"Brenner, D. J. & Hall, E. J. Computed tomography\u2014an increasing source of radiation exposure. New Engl. J. Med. 357, 2277\u20132284 (2007).","journal-title":"New Engl. J. Med."},{"key":"57_CR5","doi-asserted-by":"publisher","first-page":"2071","DOI":"10.1001\/archinternmed.2009.440","volume":"169","author":"AB de Gonz\u00e1lez","year":"2009","unstructured":"de Gonz\u00e1lez, A. B. et al. Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch. Intern. Med. 169, 2071\u20132077 (2009).","journal-title":"Arch. Intern. Med."},{"key":"57_CR6","doi-asserted-by":"publisher","first-page":"2078","DOI":"10.1001\/archinternmed.2009.427","volume":"169","author":"R Smith-Bindman","year":"2009","unstructured":"Smith-Bindman, R. et al. Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch. Intern. Med. 169, 2078\u20132086 (2009).","journal-title":"Arch. Intern. Med."},{"key":"57_CR7","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1056\/NEJMoa1102873","volume":"2011","author":"National Lung Screening Trial Research Team","year":"2011","unstructured":"National Lung Screening Trial Research Team Reduced lung-cancer mortality with low-dose computed tomographic screening. New Engl. J. Med. 2011, 395\u2013409 (2011).","journal-title":"New Engl. J. Med."},{"key":"57_CR8","first-page":"2059","volume":"5747","author":"J Wang","year":"2005","unstructured":"Wang, J., Lu, H., Li, T. & Liang, Z. Sinogram noise reduction for low-dose CT by statistics-based nonlinear filters. Proc. SPIE 5747, 2059 (2005).","journal-title":"Proc. SPIE"},{"key":"57_CR9","doi-asserted-by":"publisher","first-page":"4911","DOI":"10.1118\/1.3232004","volume":"36","author":"A Manduca","year":"2009","unstructured":"Manduca, A. et al. Projection space denoising with bilateral filtering and CT noise modeling for dose reduction in CT. Med. Phys. 36, 4911\u20134919 (2009).","journal-title":"Med. Phys."},{"key":"57_CR10","doi-asserted-by":"publisher","first-page":"1272","DOI":"10.1109\/TMI.2006.882141","volume":"25","author":"J Wang","year":"2006","unstructured":"Wang, J., Li, T., Lu, H. & Liang, Z. Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography. IEEE Trans. Med. Imaging 25, 1272\u20131283 (2006).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR11","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1148\/radiol.2015132766","volume":"276","author":"LL Geyer","year":"2015","unstructured":"Geyer, L. L. et al. State of the art: iterative CT reconstruction techniques. Radiology 276, 339\u2013357 (2015).","journal-title":"Radiology"},{"key":"57_CR12","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.1007\/s00330-012-2764-z","volume":"23","author":"MJ Willemink","year":"2013","unstructured":"Willemink, M. J. et al. Iterative reconstruction techniques for computed tomography. Part 2: Initial results in dose reduction and image quality. Eur. Radiol. 23, 1632\u20131642 (2013).","journal-title":"Eur. Radiol."},{"key":"57_CR13","doi-asserted-by":"publisher","first-page":"1498","DOI":"10.1109\/TMI.2018.2832007","volume":"37","author":"X Zheng","year":"2018","unstructured":"Zheng, X., Ravishankar, S., Long, Y. & Fessler, J. A. PWLS-ULTRA: an efficient clustering and learning-based approach for low-dose 3D CT image reconstruction. IEEE Trans. Med. Imaging 37, 1498\u20131510 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR14","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1364\/BOE.8.000679","volume":"8","author":"H Chen","year":"2017","unstructured":"Chen, H. et al. Low-dose CT via convolutional neural network. Biomed. Opt. Express 8, 679\u2013694 (2017).","journal-title":"Biomed. Opt. Express"},{"key":"57_CR15","doi-asserted-by":"publisher","first-page":"2524","DOI":"10.1109\/TMI.2017.2715284","volume":"36","author":"H Chen","year":"2017","unstructured":"Chen, H. et al. Low-dose CT with a residual encoder\u2013decoder convolutional neural network. IEEE Trans. Med. Imaging 36, 2524\u20132535 (2017).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR16","doi-asserted-by":"publisher","first-page":"2536","DOI":"10.1109\/TMI.2017.2708987","volume":"36","author":"JM Wolterink","year":"2017","unstructured":"Wolterink, J. M., Leiner, T., Viergever, M. A. & I\u0161gum, I. Generative adversarial networks for noise reduction in low-dose CT. IEEE Trans. Med. Imaging 36, 2536\u20132545 (2017).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR17","doi-asserted-by":"publisher","first-page":"1348","DOI":"10.1109\/TMI.2018.2827462","volume":"37","author":"Q Yang","year":"2018","unstructured":"Yang, Q. et al. Low-dose CT image denoising using a generative adversarial network with Wasserstein distance and perceptual loss. IEEE Trans. Med. Imaging 37, 1348\u20131357 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR18","doi-asserted-by":"publisher","first-page":"1358","DOI":"10.1109\/TMI.2018.2823756","volume":"37","author":"E Kang","year":"2018","unstructured":"Kang, E., Chang, W., Yoo, J. & Ye, J. C. Deep convolutional framelet denosing for low-dose CT via wavelet residual network. IEEE Trans. Med. Imaging 37, 1358\u20131369 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR19","doi-asserted-by":"publisher","first-page":"1522","DOI":"10.1109\/TMI.2018.2832217","volume":"37","author":"H Shan","year":"2018","unstructured":"Shan, H. et al. 3D convolutional encoder\u2013decoder network for low-dose CT via transfer learning from a 2D trained network. IEEE Trans. Med. Imaging 37, 1522\u20131534 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"57_CR20","doi-asserted-by":"crossref","unstructured":"Choi, K., Kim, S. W. & Lim, J. S. Real-time image reconstruction for low-dose CT using deep convolutional generative adversarial networks (GANs). In Medical Imaging 2018: Physics of Medical Imaging Vol. 10573, 1057332 (International Society for Optics and Photonics, 2018).","DOI":"10.1117\/12.2293420"},{"key":"57_CR21","doi-asserted-by":"crossref","unstructured":"Kim, B., Han, M., Shim, H. & Baek, J. Performance comparison of convolutional neural network based denoising in low dose CT images for various loss functions. In Medical Imaging 2019: Physics of Medical Imaging Vol. 10948, 1094849 (International Society for Optics and Photonics, 2019).","DOI":"10.1117\/12.2512183"},{"key":"57_CR22","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.neucom.2018.01.015","volume":"284","author":"Y Liu","year":"2018","unstructured":"Liu, Y. & Zhang, Y. Low-dose CT restoration via stacked sparse denoising autoencoders. Neurocomputing 284, 80\u201389 (2018).","journal-title":"Neurocomputing"},{"key":"57_CR23","doi-asserted-by":"publisher","first-page":"41839","DOI":"10.1109\/ACCESS.2018.2858196","volume":"6","author":"C You","year":"2018","unstructured":"You, C. et al. Structurally-sensitive multi-scale deep neural network for low-dose CT denoising. IEEE Access 6, 41839\u201341855 (2018).","journal-title":"IEEE Access"},{"key":"57_CR24","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1002\/mp.13415","volume":"46","author":"Z Hu","year":"2019","unstructured":"Hu, Z. et al. Artifact correction in low-dose dental CT imaging using Wasserstein generative adversarial networks. Med. Phys. 46, 1686\u20131696 (2019).","journal-title":"Med. Phys."},{"key":"57_CR25","doi-asserted-by":"crossref","unstructured":"Gholizadeh-Ansari, M., Alirezaie, J. & Babyn, P. Deep learning for low-dose CT denoising using perceptual loss and edge detection layer. Preprint at https:\/\/arxiv.org\/abs\/1902.10127 (2019).","DOI":"10.1109\/EMBC.2019.8857940"},{"key":"57_CR26","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1007\/s10278-018-0056-0","volume":"31","author":"X Yi","year":"2018","unstructured":"Yi, X. & Babyn, P. Sharpness-aware low-dose CT denoising using conditional generative adversarial network. J. Digit. Imaging 31, 655\u2013669 (2018).","journal-title":"J. Digit. Imaging"},{"key":"57_CR27","doi-asserted-by":"crossref","unstructured":"Ronneberger, O., Fischer, P. & Brox, T. U-Net: convolutional networks for biomedical image segmentation. In Proceedings of Medical Image Computing and Computer Assisted Intervention (MICCAI) 234\u2013241 (Springer, 2015).","DOI":"10.1007\/978-3-319-24574-4_28"},{"key":"57_CR28","unstructured":"Pascanu, R., Mikolov, T. & Bengio, Y. On the difficulty of training recurrent neural networks. In Proceedings of the International Conference on Machine Learning 1310\u20131318 (JMLR, 2013)."},{"key":"57_CR29","doi-asserted-by":"crossref","unstructured":"Tai, Y., Yang, J. & Liu, X. Image super-resolution via deep recursive residual network. In Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR) 2790\u20132798 (IEEE, 2017).","DOI":"10.1109\/CVPR.2017.298"},{"key":"57_CR30","unstructured":"Gulrajani, I., Ahmed, F., Arjovsky, M., Dumoulin, V. & Courville, A. C. Improved training of Wasserstein GANs. In Advances in Neural Information Processing Systems (NIPS), 5769\u20135779 (Curran Associates, 2017)."},{"key":"57_CR31","unstructured":"Goodfellow, I. et al. Generative adversarial nets. In Advances in Neural Information Processing Systems (NIPS) 2672\u20132680 (Curran Associates, 2014)."},{"key":"57_CR32","unstructured":"Arjovsky, M., Chintala, S. & Bottou, L. Wasserstein generative adversarial networks. In Proceedings of the International Conference on Machine Learning (ICML) 214\u2013223 (JMLR, 2017)."},{"key":"57_CR33","unstructured":"Kingma, D. & Ba, J. Adam: a method for stochastic optimization. Preprint at https:\/\/arxiv.org\/abs\/1412.6980 (2014)."},{"key":"57_CR34","unstructured":"Abadi, M. et al. Tensorflow: large-scale machine learning on heterogeneous distributed systems. Preprint at https:\/\/arxiv.org\/abs\/1603.04467 (2016)."},{"key":"57_CR35","unstructured":"Conover, W. J. & Conover, W. J. Practical Nonparametric Statistics Ch. 3 (Wiley, 1980)."}],"container-title":["Nature Machine Intelligence"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s42256-019-0057-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s42256-019-0057-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s42256-019-0057-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,17]],"date-time":"2022-12-17T19:39:35Z","timestamp":1671305975000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s42256-019-0057-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,10]]},"references-count":35,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2019,6]]}},"alternative-id":["57"],"URL":"https:\/\/doi.org\/10.1038\/s42256-019-0057-9","relation":{},"ISSN":["2522-5839"],"issn-type":[{"value":"2522-5839","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,10]]},"assertion":[{"value":"16 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"G.W. and H.S. have received unrelated industrial research grants from General Electric and Hologic Inc. M.K.K. has received unrelated industrial research grants from Siemens Healthineers and Riverain Inc.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}