{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T01:27:24Z","timestamp":1789608444873,"version":"build-2803163510"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2008,2,22]],"date-time":"2008-02-22T00:00:00Z","timestamp":1203638400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eye"],"published-print":{"date-parts":[[2008,10]]},"DOI":"10.1038\/eye.2008.20","type":"journal-article","created":{"date-parts":[[2008,2,22]],"date-time":"2008-02-22T11:17:29Z","timestamp":1203679049000},"page":"1263-1266","source":"Crossref","is-referenced-by-count":44,"title":["25-, 23-, or 20-gauge instrumentation for vitreous surgery?"],"prefix":"10.1038","volume":"22","author":[{"given":"G A","family":"Williams","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2008,2,22]]},"reference":[{"key":"BFeye200820_CR1","first-page":"462","volume":"76","author":"R Machemer","year":"1972","unstructured":"Machemer R, Parel JM, Norton EW . Vitrectomy: a pars plana approach: technical improvements and further results. Trans Am Acad Ophthalmol Otolaryngol 1972; 76: 462\u2013466.","journal-title":"Trans Am Acad Ophthalmol Otolaryngol"},{"key":"BFeye200820_CR2","first-page":"585","volume":"7","author":"C O'Malley","year":"1975","unstructured":"O'Malley C, Heintz Sr RM . Vitrectomy with an alternative instrument system. Ann Ophthalmol 1975; 7: 585\u2013588: 91\u201394.","journal-title":"Ann Ophthalmol"},{"key":"BFeye200820_CR3","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1016\/S0161-6420(02)01179-X","volume":"109","author":"GY Fujii","year":"2002","unstructured":"Fujii GY, de Juan Jr E, Humayun MS, Pieramici DJ, Chang TS, Awh C et al. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery. Ophthalmology 2002; 109: 1807\u20131812: Discussion 1813.","journal-title":"Ophthalmology"},{"key":"BFeye200820_CR4","doi-asserted-by":"publisher","first-page":"1814","DOI":"10.1016\/S0161-6420(02)01119-3","volume":"109","author":"GY Fujii","year":"2002","unstructured":"Fujii GY, de Juan Jr E, Humayun MS, Chang TS, Pieramici DJ, Barnes A et al. Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery. Ophthalmology 2002; 109: 1814\u20131820.","journal-title":"Ophthalmology"},{"key":"BFeye200820_CR5","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1097\/00006982-200502000-00015","volume":"25","author":"C Eckardt","year":"2005","unstructured":"Eckardt C . Transconjunctival sutureless 23-gauge vitrectomy. Retina 2005; 25: 208\u2013224.","journal-title":"Retina"},{"key":"BFeye200820_CR6","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1016\/S0002-9394(14)75990-2","volume":"109","author":"E de Juan Jr","year":"1990","unstructured":"de Juan Jr E, Hickingbotham D . Refinements in microinstrumentation for vitreous surgery. Am J Ophthalmol 1990; 109: 218\u2013220.","journal-title":"Am J Ophthalmol"},{"key":"BFeye200820_CR7","first-page":"24","volume":"3","author":"S Charles","year":"2006","unstructured":"Charles S . Debating the pros and cons of 23-g vs 25-g vitrectomy: the pros of 25-g vitrectomy. Retin Physician 2006; 3: 24\u201325.","journal-title":"Retin Physician"},{"key":"BFeye200820_CR8","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.ajo.2006.07.051","volume":"143","author":"Y Oshima","year":"2007","unstructured":"Oshima Y, Awh CC, Tano Y . Self-retaining 27 gauge transconjunctival chandelier endoilluminator for panoramic viewing during vitreous surgery. Am J Ophthalmol 2007; 143: 166\u2013167.","journal-title":"Am J Ophthalmol"},{"key":"BFeye200820_CR9","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1007\/s00417-006-0428-x","volume":"245","author":"Y Yanagi","year":"2007","unstructured":"Yanagi Y, Iriyama A, Jan WD, Kadonosono K . Evaluation of the safety of xenon\/bandpass light in vitrectomy using the A2E-laden RPE model. Graefe's Arch Clin Exp Ophthalmol 2007; 245: 677\u2013681.","journal-title":"Graefe's Arch Clin Exp Ophthalmol"},{"key":"BFeye200820_CR10","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1016\/j.ajo.2004.12.002","volume":"139","author":"MS Ibarra","year":"2005","unstructured":"Ibarra MS, Hermel M, Prenner JL, Hassan TS . Longer-term outcomes of transconjunctival sutureless 25-gauge vitrectomy. Am J Ophthalmol 2005; 139: 831\u2013836.","journal-title":"Am J Ophthalmol"},{"key":"BFeye200820_CR11","doi-asserted-by":"publisher","first-page":"817","DOI":"10.1016\/j.ophtha.2004.11.053","volume":"112","author":"RR Lakhanpal","year":"2005","unstructured":"Lakhanpal RR, Humayun MS, de Juan Jr E, Lim JI, Chang LP, Chang TS et al. Outcomes of 140 consecutive cases of 25-gauge transconjunctival surgery for posterior segment disease. Ophthalmology 2005; 112: 817\u2013824.","journal-title":"Ophthalmology"},{"key":"BFeye200820_CR12","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1007\/s00417-005-0173-6","volume":"244","author":"S Rizzo","year":"2006","unstructured":"Rizzo S, Genovesi-Ebert F, Murri S, Belting C, Vento A, Cresti F et al. 25-gauge, sutureless vitrectomy and standard 20-gauge pars plana vitrectomy in idiopathic epiretinal membrane surgery: a comparative pilot study. Graefes Arch Clin Exp Ophthalmol 2006; 244: 472\u2013479.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"BFeye200820_CR13","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.ajo.2006.03.060","volume":"142","author":"K Kadonosono","year":"2006","unstructured":"Kadonosono K, Yamakawa T, Uchio E, Yanagi Y, Tamaki Y, Araie M et al. Comparison of visual function after epiretinal membrane removal by 20-gauge and 25-gauge vitrectomy. Am J Ophthalmol 2006; 142: 513\u2013515.","journal-title":"Am J Ophthalmol"},{"key":"BFeye200820_CR14","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1177\/112067210601600123","volume":"16","author":"A Yanyali","year":"2006","unstructured":"Yanyali A, Celik E, Horozoglu F, Oner S, Nohutcu AF . 25-gauge transconjunctival sutureless pars plana vitrectomy. Eur J Ophthalmol 2006; 16: 141\u2013147.","journal-title":"Eur J Ophthalmol"},{"key":"BFeye200820_CR15","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1016\/j.ajo.2005.05.042","volume":"140","author":"A Yanyali","year":"2005","unstructured":"Yanyali A, Celik E, Horozoglu F, Nohutcu AF . Corneal topographic changes after transconjunctival (25-gauge) sutureless vitrectomy. Am J Ophthalmol 2005; 140: 939\u2013941.","journal-title":"Am J Ophthalmol"},{"key":"BFeye200820_CR16","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1016\/j.ajo.2006.05.057","volume":"142","author":"H Shimada","year":"2006","unstructured":"Shimada H, Nakashizuka H, Mori R, Mizutani Y, Hattori T . 25-gauge scleral tunnel transconjunctival vitrectomy. Am J Ophthalmol 2006; 142: 871\u2013873.","journal-title":"Am J Ophthalmol"},{"key":"BFeye200820_CR17","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1055\/s-2007-962957","volume":"224","author":"C Valmaggia","year":"2007","unstructured":"Valmaggia C . Pars plana vitrectomy with 25-gauge instruments in the treatment of idiopathic epiretinal membranes. Klin Monatsbl Augenheilkd 2007; 224: 292\u2013296.","journal-title":"Klin Monatsbl Augenheilkd"},{"key":"BFeye200820_CR18","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1136\/bjo.2006.106799","volume":"91","author":"L Kellner","year":"2007","unstructured":"Kellner L, Wimpissinger B, Stolba V, Brannath W, Binder S . 25-gauge vs 20-gauge system for pars plana vitrectomy: a prospective randomized clinical trial. Br J Ophthalmol 2007; 91: 945\u2013948.","journal-title":"Br J Ophthalmol"},{"key":"BFeye200820_CR19","doi-asserted-by":"crossref","first-page":"175","DOI":"10.47102\/annals-acadmedsg.V35N3p175","volume":"35","author":"Y Oshima","year":"2006","unstructured":"Oshima Y, Ohji M, Tano Y . Surgical outcomes of 25-gauge transconjunctival vitrectomy combined with cataract surgery for vitreoretinal diseases. Ann Acad Med Singapore 2006; 35: 175\u2013180.","journal-title":"Ann Acad Med Singapore"},{"key":"BFeye200820_CR20","first-page":"25","volume":"3","author":"R Spaide","year":"2006","unstructured":"Spaide R, Fine H . The pros of 25\u2009g vitrectomy. Retin Physician 2006; 3: 25\u201328.","journal-title":"Retin Physician"},{"key":"BFeye200820_CR21","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.ajo.2006.07.038","volume":"143","author":"R Scartozzi","year":"2007","unstructured":"Scartozzi R, Bessa AS, Gupta OP, Regillo CD . Intraoperative sclerotomy-related retinal breaks for macular surgery. 20 vs 25 gauge vitrectomy systems. Am J Ophthalmol 2007; 143: 155\u2013156.","journal-title":"Am J Ophthalmol"},{"key":"BFeye200820_CR22","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s00417-006-0354-y","volume":"245","author":"T Okuda","year":"2007","unstructured":"Okuda T, Nichimura A, Kobayashi A, Sugiyama K . Postoperative retinal break after 15 gauge transconjunctival sutureless vitrectomy: report of four cases. Graefes Arch Clin Exp Ophthalmol. 2007; 245: 155\u2013157.","journal-title":"Graefes Arch Clin Exp Ophthalmol."},{"key":"BFeye200820_CR23","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1097\/ICU.0b013e328133889a","volume":"18","author":"E Chen","year":"2007","unstructured":"Chen E . 25-gauge transconjunctival sutureless vitrectomy. Curr Opin Ophthalmol 2007; 18: 188\u2013193.","journal-title":"Curr Opin Ophthalmol"},{"key":"BFeye200820_CR24","doi-asserted-by":"publisher","first-page":"1228","DOI":"10.1038\/sj.eye.6701737","volume":"19","author":"SRJ Taylor","year":"2005","unstructured":"Taylor SRJ, Aylward GW . Endophthalmitis following 25 gauge vitrectomy. Eye 2005; 19: 1228\u20131229.","journal-title":"Eye"},{"key":"BFeye200820_CR25","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1097\/01.iae.0000244272.13890.cc","volume":"26","author":"M Taban","year":"2006","unstructured":"Taban M, Ufret-Vincenty RL, Sears JE . Endophthalmitis after 25 gauge transconjunctival sutureless vitrectomy. Retina 2006; 26: 830\u2013831.","journal-title":"Retina"},{"key":"BFeye200820_CR26","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1016\/j.ophtha.2007.02.020","volume":"114","author":"HF Fine","year":"2007","unstructured":"Fine HF, Iranmanesh R, Iturralde D, Spaide RF . Outcomes of 77 consecutive cases of 23-gauge transconjunctival vitrectomy surgery for posterior segment disease. Ophthalmology 2007; 114: 1197\u20131200.","journal-title":"Ophthalmology"}],"container-title":["Eye"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.nature.com\/articles\/eye200820.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/eye200820","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/eye200820.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,18]],"date-time":"2023-05-18T17:04:44Z","timestamp":1684429484000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/eye200820"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,2,22]]},"references-count":26,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2008,10]]}},"alternative-id":["BFeye200820"],"URL":"https:\/\/doi.org\/10.1038\/eye.2008.20","relation":{},"ISSN":["0950-222X","1476-5454"],"issn-type":[{"value":"0950-222X","type":"print"},{"value":"1476-5454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2008,2,22]]}}}