{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T14:02:14Z","timestamp":1772805734985,"version":"3.50.1"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2015,10,23]],"date-time":"2015-10-23T00:00:00Z","timestamp":1445558400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye"],"published-print":{"date-parts":[[2016,1]]},"DOI":"10.1038\/eye.2015.202","type":"journal-article","created":{"date-parts":[[2015,10,23]],"date-time":"2015-10-23T09:34:04Z","timestamp":1445592844000},"page":"102-110","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Depth evaluation of intended vs actual intacs intrastromal ring segments using optical coherence tomography"],"prefix":"10.1038","volume":"30","author":[{"given":"R","family":"Barbara","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A","family":"Barbara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M","family":"Naftali","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,10,23]]},"reference":[{"issue":"1","key":"BFeye2015202_CR1","first-page":"16","volume":"1","author":"JM Salgado-Borges","year":"2012","unstructured":"Salgado-Borges JM, Costa-Ferreira C, Monteiro M, Guilherme-Monteiro J, Torquestti L, Ferrara P AR JR . Refractive, tomographic and biomechanical outcomes after implantation of Ferrara ICRS in keratoconus patients. Int J Kerat Ect Cor Dis 2012; 1 (1): 16\u201321.","journal-title":"Int J Kerat Ect Cor Dis"},{"issue":"2","key":"BFeye2015202_CR2","first-page":"109","volume":"1","author":"R Borbara","year":"2012","unstructured":"Borbara R, Garzozi H BA . Combined intacs SK and corneal collagen cross-linking for the treatment of keratoconus. Int J Kerat Ect Cor Dis 2012; 1 (2): 109\u2013116.","journal-title":"Int J Kerat Ect Cor Dis"},{"issue":"7","key":"BFeye2015202_CR3","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1016\/S0161-6420(97)30183-3","volume":"104","author":"DJ Schanzlin","year":"1997","unstructured":"Schanzlin DJ, Asbell PA, Burris TE, Durrie DS . The intrastromal corneal ring segments. Phase II results for the correction of myopia. Ophthalmology 1997; 104 (7): 1067.","journal-title":"Ophthalmology"},{"issue":"5","key":"BFeye2015202_CR4","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1016\/j.jcrs.2006.01.064","volume":"32","author":"J Colin","year":"2006","unstructured":"Colin J . European clinical evaluation: use of Intacs for the treatment of keratoconus. J Cataract Refract Surg 2006; 32 (5): 747\u2013755.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"BFeye2015202_CR5","doi-asserted-by":"publisher","first-page":"1568","DOI":"10.1016\/S0886-3350(01)01275-5","volume":"28","author":"J Alio","year":"2002","unstructured":"Alio J, Salem T, Artola A, Osman A . Intracorneal rings to correct corneal ectasia after laser in situ keratomileusis. J Cataract Refract Surg 2002; 28 (9): 1568.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"BFeye2015202_CR6","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.1016\/j.jcrs.2007.02.048","volume":"33","author":"A Ertan","year":"2007","unstructured":"Ertan A, Colin J . Intracorneal rings for keratoconus and keratectasia. J Cataract Refract Surg 2007; 33 (7): 1303\u20131314.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"BFeye2015202_CR7","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1001\/archopht.121.3.322","volume":"121","author":"GD Kymionis","year":"2003","unstructured":"Kymionis GD, Siganos CS, Kounis G, Astyrakakis N, Kalyvianaki MI, Pallikaris IG . Management of post-LASIK corneal ectasia with Intacs inserts: one-year results. Arch Ophthalmol 2003; 121 (3): 322.","journal-title":"Arch Ophthalmol"},{"issue":"2","key":"BFeye2015202_CR8","doi-asserted-by":"publisher","first-page":"171","DOI":"10.5301\/ejo.5000212","volume":"23","author":"M Naftali","year":"2013","unstructured":"Naftali M, Jabaly-Habib H . Depth of intrastromal corneal ring segments by OCT. Eur J Ophthalmol 2013; 23 (2): 171\u2013176.","journal-title":"Eur J Ophthalmol"},{"key":"BFeye2015202_CR9","unstructured":"Addition Technology. Intacs corneal ring segments for the treatment of keratoconus. International Surgeon Training Manual 2007; 3.1-1\u20133.1-8."},{"issue":"7","key":"BFeye2015202_CR10","doi-asserted-by":"publisher","first-page":"719","DOI":"10.1097\/ICO.0b013e318191b83d","volume":"28","author":"A Ertan","year":"2009","unstructured":"Ertan A, Karacal H, Kamburo\u011flu G . Refractive and topographic results of transepithelial cross-linking treatment in eyes with intacs. Cornea 2009; 28 (7): 719\u2013723.","journal-title":"Cornea"},{"key":"BFeye2015202_CR11","doi-asserted-by":"crossref","unstructured":"Barbara R, Barbara A . Textbook on Keratoconus - New Insights 2012; 126\u2013162.","DOI":"10.5005\/jp\/books\/11483_15"},{"issue":"1","key":"BFeye2015202_CR12","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1097\/01.ico.0000167883.63266.60","volume":"25","author":"AJ Kanellopoulos","year":"2006","unstructured":"Kanellopoulos AJ, Lawrence HP, Perry HD, Donnenfeld ED . Modified intracorneal ring segment implantations (INTACS) for the management of moderate to advanced keratoconus: efficacy and complications. Cornea 2006; 25 (1): 29\u201333.","journal-title":"Cornea"},{"issue":"11","key":"BFeye2015202_CR13","doi-asserted-by":"publisher","first-page":"1860","DOI":"10.1016\/j.jcrs.2006.05.030","volume":"32","author":"MM Lai","year":"2006","unstructured":"Lai MM, Tang M, Andrade EMM, Li Y, Khurana RN, Song JC et al. Optical coherence tomography to assess intrastromal corneal ring segment depth in keratoconic eyes. J Cataract Refract Surg 2006; 32 (11): 1860\u20131865.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"BFeye2015202_CR14","doi-asserted-by":"publisher","first-page":"377","DOI":"10.3928\/1081597X-20090401-05","volume":"25","author":"G Kamburoglu","year":"2009","unstructured":"Kamburoglu G, Ertan A, Sara\u00e7basi O . Measurement of depth of Intacs implanted via femtosecond laser using Pentacam. J Refract Surg 2009; 25 (4): 377\u2013382.","journal-title":"J Refract Surg"},{"issue":"2","key":"BFeye2015202_CR15","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.jfo.2011.03.014","volume":"35","author":"FX Kouassi","year":"2012","unstructured":"Kouassi FX, Buestel C, Raman B, Melinte D, Touboul D, Gallois A CJ . Comparison of the depth predictability of intra corneal ring segment implantation by mechanical versus femtosecond laser-assisted techniques using optical coherence tomography (OCT Visante). J Fr Ophtalmol 2012; 35 (2): 94\u201399.","journal-title":"J Fr Ophtalmol"},{"issue":"3","key":"BFeye2015202_CR16","doi-asserted-by":"publisher","first-page":"214","DOI":"10.3928\/15428877-20120301-01","volume":"43","author":"E Gorgun","year":"2012","unstructured":"Gorgun E, Kucumen RB, Yenerel NM, Ciftci F . Assessment of intrastromal corneal ring segment position with anterior segment optical coherence tomography. Ophthalmic Surg Lasers Imaging 2012; 43 (3): 214\u2013221.","journal-title":"Ophthalmic Surg Lasers Imaging"},{"issue":"6","key":"BFeye2015202_CR17","doi-asserted-by":"publisher","first-page":"970","DOI":"10.1016\/j.jcrs.2009.12.042","volume":"36","author":"C Ferrer","year":"2010","unstructured":"Ferrer C, Ali\u00f3 JL, Monta\u00f1\u00e9s AU, P\u00e9rez-Santonja JJ, del Rio MA, de Toledo JA et al. Causes of intrastromal corneal ring segment explantation: clinicopathologic correlation analysis. J Cataract Refract Surg 2010; 36 (6): 970\u2013977.","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"BFeye2015202_CR18","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1016\/j.jcrs.2008.03.008","volume":"34","author":"BU Tan","year":"2008","unstructured":"Tan BU, Purcell TL, Nalgirkar A, Ehrenhaus MP, Torres LF, Schanzlin DJ . Photorefractive keratectomy for the correction of residual refractive error with Intacs intrastromal corneal ring segments in place. J Cataract Refract Surg 2008; 34 (6): 909\u2013915.","journal-title":"J Cataract Refract Surg"}],"container-title":["Eye"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.nature.com\/articles\/eye2015202.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/eye2015202","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/eye2015202.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,18]],"date-time":"2023-05-18T17:25:53Z","timestamp":1684430753000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/eye2015202"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10,23]]},"references-count":18,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,1]]}},"alternative-id":["BFeye2015202"],"URL":"https:\/\/doi.org\/10.1038\/eye.2015.202","relation":{},"ISSN":["0950-222X","1476-5454"],"issn-type":[{"value":"0950-222X","type":"print"},{"value":"1476-5454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,10,23]]},"assertion":[{"value":"29 January 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 August 2015","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 October 2015","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}