{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T21:12:30Z","timestamp":1773436350918,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2015,12,4]],"date-time":"2015-12-04T00:00:00Z","timestamp":1449187200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye"],"published-print":{"date-parts":[[2016,3]]},"DOI":"10.1038\/eye.2015.248","type":"journal-article","created":{"date-parts":[[2015,12,4]],"date-time":"2015-12-04T10:32:33Z","timestamp":1449225153000},"page":"431-437","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Which tonometry in eyes with keratoconus?"],"prefix":"10.1038","volume":"30","author":[{"given":"H","family":"Altinkaynak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C","family":"Kocasarac","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H","family":"Dundar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N","family":"Sayin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N","family":"Kara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E","family":"Bozkurt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N","family":"Duru","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,12,4]]},"reference":[{"key":"BFeye2015248_CR1","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","volume":"42","author":"YS Rabinovitz","year":"1998","unstructured":"Rabinovitz YS . Keratoconus. Surv Ophthalmol 1998; 42: 297\u2013319.","journal-title":"Surv Ophthalmol"},{"key":"BFeye2015248_CR2","doi-asserted-by":"publisher","first-page":"3026","DOI":"10.1167\/iovs.04-0694","volume":"48","author":"S Shah","year":"2007","unstructured":"Shah S, Laiquzzaman M, Bhojwani R, Mantry S, Cunliffe I . Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest Ophthalmol Vis Sci 2007; 48: 3026\u20133031.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"BFeye2015248_CR3","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1016\/j.jcrs.2007.04.021","volume":"33","author":"D Ortiz","year":"2007","unstructured":"Ortiz D, Pinero D, Shabayek MH, Arnalich-Montiel F, Ali\u00f3 JL . Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes. J Cataract Refract Surg 2007; 33: 1371\u20131375.","journal-title":"J Cataract Refract Surg"},{"key":"BFeye2015248_CR4","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1136\/bjo.2007.136473","volume":"92","author":"SP Mollan","year":"2008","unstructured":"Mollan SP, Wolffsohn JS, Nessim M, Laiquzzaman M, Sivakumar S, Hartley S et al. Accuracy of Goldmann, ocular response analyser, pascal and tonoPen XL tonometry in keratoconic and normal eyes. Br J Ophthalmol 2008; 92: 1661\u20131665.","journal-title":"Br J Ophthalmol"},{"key":"BFeye2015248_CR5","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1111\/j.1442-9071.1984.tb01175.x","volume":"12","author":"AM Brooks","year":"1984","unstructured":"Brooks AM, Robertson IF, Mahoney AM . Ocular rigidity and intraocular pressure in keratoconus. Aust J Ophthalmol 1984; 12: 317\u2013324.","journal-title":"Aust J Ophthalmol"},{"key":"BFeye2015248_CR6","doi-asserted-by":"publisher","first-page":"771","DOI":"10.1007\/s003470050201","volume":"94","author":"A Bohm","year":"1997","unstructured":"Bohm A, Kohlhaas M, Lerche RC, Bischoff B, Richard G . Measuring intraocular pressure in keratoconus. Effect of the changed biomechanics. Ophthalmologe 1997; 94: 771\u2013774.","journal-title":"Ophthalmologe"},{"key":"BFeye2015248_CR7","doi-asserted-by":"publisher","first-page":"1137","DOI":"10.1001\/archopht.1997.01100160307007","volume":"115","author":"LW Herndon","year":"1997","unstructured":"Herndon LW, Choudhri SA, Cox T, Damji KF, Shields MB, Allingham RR . Central corneal thickness in normal, glaucomatous, and ocular hypertensive eyes. Arch Ophthalmol 1997; 115: 1137\u20131141.","journal-title":"Arch Ophthalmol"},{"key":"BFeye2015248_CR8","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1097\/01.icu.0000193093.05927.a1","volume":"17","author":"LW Herndon","year":"2006","unstructured":"Herndon LW . Measuring intraocular pressure-adjustments for corneal thickness and new technologies. Curr Opin Ophthalmol 2006; 17: 115\u2013119.","journal-title":"Curr Opin Ophthalmol"},{"key":"BFeye2015248_CR9","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1016\/S0002-9394(14)71455-2","volume":"115","author":"MM Whitacre","year":"1993","unstructured":"Whitacre MM, Stein RA, Hassanein K . The effect of corneal thickness on applanation tonometry. Am J Ophthalmol 1993; 115: 592\u2013596.","journal-title":"Am J Ophthalmol"},{"key":"BFeye2015248_CR10","doi-asserted-by":"publisher","first-page":"1617","DOI":"10.1007\/s00417-010-1471-1","volume":"248","author":"J Wasielica-Poslednik","year":"2010","unstructured":"Wasielica-Poslednik J, Berisha F, Aliyeva S, Pfeiffer N, Hoffmann EM . Reproducibility of ocular response analyzer measurements and their correlation with central corneal thickness. Graefes Arch Clin Exp Ophthalmol 2010; 248: 1617\u20131622.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"BFeye2015248_CR11","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","volume":"31","author":"DA Luce","year":"2005","unstructured":"Luce DA . Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg 2005; 31: 156\u2013162.","journal-title":"J Cataract Refract Surg"},{"key":"BFeye2015248_CR12","doi-asserted-by":"publisher","first-page":"1532","DOI":"10.1001\/archopht.123.11.1532","volume":"123","author":"C Kniestedt","year":"2005","unstructured":"Kniestedt C, Lin S, Choe J, Bostrom A, Nee M, Stamper RL . Clinical comparison of contour and applanation tonometry and their relationship to pachymetry. Arch Ophthalmol 2005; 123: 1532\u20131537.","journal-title":"Arch Ophthalmol"},{"key":"BFeye2015248_CR13","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1016\/j.jcrs.2003.12.033","volume":"30","author":"DS Siganos","year":"2004","unstructured":"Siganos DS, Papasterigiou GI, Moedas C . Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg 2004; 30: 746\u2013751.","journal-title":"J Cataract Refract Surg"},{"key":"BFeye2015248_CR14","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1097\/01.ijg.0000169393.40298.05","volume":"14","author":"A Doyle","year":"2005","unstructured":"Doyle A, Lachkar Y . Comparison of dynamic contour tonometry with Goldman applanation tonometry over a wide range of central corneal thickness. J Glaucoma 2005; 14: 288\u2013292.","journal-title":"J Glaucoma"},{"key":"BFeye2015248_CR15","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.optm.2009.01.013","volume":"80","author":"DH Erickson","year":"2009","unstructured":"Erickson DH, Goodwin D, Rollins M, Belaustegui A, Anderson C . Comparison of dynamic contour tonometry and Goldmann applanation tonometry and their relationship to corneal properties, refractive error, and ocular pulse amplitude. Optometry 2009; 80: 169\u2013174.","journal-title":"Optometry"},{"key":"BFeye2015248_CR16","unstructured":"Palmberg PF, Wiggs JL . Mechanisms of glaucoma. In: Janoff M, Duker JS (eds). Ophthalmology, 2nd ed. Mosby Co: St Louis, MO, USA, 2004 pp, 1423\u20131430."},{"key":"BFeye2015248_CR17","unstructured":"Shields MB, Ritch R, Krupin T . Intraocular pressure and tonometry. In Ritch R, Shields MB, Krupin T (eds) The Glaucomas, 2nd ed. 2nd vol. Mosby Times Mirror Company: St Louis, MO, USA, 1996 pp 1507\u20131520."},{"issue":"10","key":"BFeye2015248_CR18","doi-asserted-by":"publisher","first-page":"1078","DOI":"10.1097\/ICO.0b013e31820cd3d6","volume":"30","author":"JD Unterlauft","year":"2011","unstructured":"Unterlauft JD, Schadle N, Kasper K, Klink T, Geerling G . Comparison of dynamic contour tonometry and Goldmann applanation tonometry in keratoconus. Cornea 2011; 30 (10): 1078\u20131082.","journal-title":"Cornea"},{"key":"BFeye2015248_CR19","doi-asserted-by":"publisher","first-page":"540","DOI":"10.1097\/IJG.0b013e3181ca7aeb","volume":"19","author":"A Bayer","year":"2010","unstructured":"Bayer A, Sahin A, H\u00fcrmeri\u00e7 A, Ozge G . Intraocular pressure values obtained by ocular response analyzer, dynamic contour tonometry, and Goldmann tonometry in keratokonic corneas. J Glaucoma 2010; 19: 540\u2013545.","journal-title":"J Glaucoma"},{"key":"BFeye2015248_CR20","doi-asserted-by":"publisher","first-page":"1011","DOI":"10.1097\/ICO.0b013e3181cda034","volume":"29","author":"Y Goldich","year":"2010","unstructured":"Goldich Y, Barkana Y, Avni I, Zadok D . Goldmann applanation tonometry versus ocular response analyzer for intraocular pressure measurements in keratoconic eyes. Cornea 2010; 29: 1011\u20131015.","journal-title":"Cornea"},{"key":"BFeye2015248_CR21","doi-asserted-by":"publisher","first-page":"890","DOI":"10.1097\/01.ico.0000224649.12214.33","volume":"25","author":"Z Ozbek","year":"2006","unstructured":"Ozbek Z, Cohen EJ, Hammersmith KM, Rapuano CJ . Dynamic contur tonometry: a new way to asses intraocular pressure in ectatic corneas. Cornea 2006; 25: 890\u2013894.","journal-title":"Cornea"},{"key":"BFeye2015248_CR22","doi-asserted-by":"publisher","first-page":"539","DOI":"10.3928\/1081-597X-20060601-05","volume":"22","author":"JL Ali\u00f3","year":"2006","unstructured":"Ali\u00f3 JL, Shabayek MH . Corneal higher order aberrations: a method to grade keratoconus. J Refract Surg 2006; 22: 539\u2013545.","journal-title":"J Refract Surg"},{"key":"BFeye2015248_CR23","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/S0014-4835(80)80027-3","volume":"31","author":"TT Andreassen","year":"1980","unstructured":"Andreassen TT, Simonsen AH, Oxlund H . Biomechanical properties of keratoconus and normal corneas. Exp Eye Res 1980; 31: 435\u2013441.","journal-title":"Exp Eye Res"},{"key":"BFeye2015248_CR24","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/S1367-0484(03)00022-5","volume":"26","author":"MC Kenney","year":"2003","unstructured":"Kenney MC, Brown DJ . The cascade hypothesis of keratoconus. Contact Lens Anterior Eye 2003; 26: 139\u2013146.","journal-title":"Contact Lens Anterior Eye"},{"key":"BFeye2015248_CR25","doi-asserted-by":"publisher","first-page":"1395","DOI":"10.1136\/bjo.2003.037887","volume":"88","author":"AC Browning","year":"2004","unstructured":"Browning AC, Bhan A, Rotchford AP, Shah S, Dua HS . The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology. Br J Ophthalmol 2004; 88: 1395\u20131399.","journal-title":"Br J Ophthalmol"}],"container-title":["Eye"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.nature.com\/articles\/eye2015248.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/eye2015248","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/eye2015248.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,18]],"date-time":"2023-05-18T17:26:15Z","timestamp":1684430775000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/eye2015248"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12,4]]},"references-count":25,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016,3]]}},"alternative-id":["BFeye2015248"],"URL":"https:\/\/doi.org\/10.1038\/eye.2015.248","relation":{},"ISSN":["0950-222X","1476-5454"],"issn-type":[{"value":"0950-222X","type":"print"},{"value":"1476-5454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,12,4]]},"assertion":[{"value":"11 January 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 October 2015","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 December 2015","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}