{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T03:31:28Z","timestamp":1787801488116,"version":"build-2784847793"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2015,1,29]],"date-time":"2015-01-29T00:00:00Z","timestamp":1422489600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2015,1,29]],"date-time":"2015-01-29T00:00:00Z","timestamp":1422489600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Perinatol"],"published-print":{"date-parts":[[2015,7]]},"DOI":"10.1038\/jp.2014.245","type":"journal-article","created":{"date-parts":[[2015,1,29]],"date-time":"2015-01-29T09:32:05Z","timestamp":1422523925000},"page":"485-489","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Influence of patent ductus arteriosus and ventilators on electrical velocimetry for measuring cardiac output in very-low\/low birth weight infants"],"prefix":"10.1038","volume":"35","author":[{"given":"T","family":"Torigoe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Y","family":"Nagayama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T","family":"Sato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,1,29]]},"reference":[{"issue":"3","key":"BFjp2014245_CR1","doi-asserted-by":"publisher","first-page":"R72","DOI":"10.1186\/cc4913","volume":"10","author":"SM Lobo","year":"2006","unstructured":"Lobo SM, Lobo FR, Polachini CA, Patini DS, Yamamoto AE, de Oliveira NE et al. Prospective, randomized trial comparing fluids and dobutamine optimization of oxygen delivery in high-risk surgical patients [ISRCTN42445141]. Crit Care 2006; 10 (3): R72.","journal-title":"Crit Care"},{"issue":"19","key":"BFjp2014245_CR2","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.1056\/NEJMoa010307","volume":"345","author":"E Rivers","year":"2001","unstructured":"Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B et al. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med 2001; 345 (19): 1368\u20131377.","journal-title":"N Engl J Med"},{"issue":"6","key":"BFjp2014245_CR3","doi-asserted-by":"publisher","first-page":"R687","DOI":"10.1186\/cc3887","volume":"9","author":"R Pearse","year":"2005","unstructured":"Pearse R, Dawson D, Fawcett J, Rhodes A, Grounds RM, Bennett ED . Early goal-directed therapy after major surgery reduces complications and duration of hospital stay. A randomised, controlled trial [ISRCTN38797445]. Crit Care 2005; 9 (6): R687\u2013R693.","journal-title":"Crit Care"},{"issue":"1","key":"BFjp2014245_CR4","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1016\/j.jtcvs.2006.07.038","volume":"133","author":"U Fakler","year":"2007","unstructured":"Fakler U, Ch Pauli, Balling G, Lorenz HP, Eicken A, Hennig M et al. Cardiac index monitoring by pulse contour analysis and thermodilution after pediatric cardiac surgery. J Thorac Cardiovasc Surg 2007; 133 (1): 224\u2013228.","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"12","key":"BFjp2014245_CR5","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1097\/EJA.0b013e32832bfd94","volume":"26","author":"W Raue","year":"2009","unstructured":"Raue W, Swierzy M, Koplin G, Schwenk W . Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients. Eur J Anaesthesiol 2009; 26 (12): 1067\u20131071.","journal-title":"Eur J Anaesthesiol"},{"issue":"8","key":"BFjp2014245_CR6","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1111\/j.1460-9592.2007.02210.x","volume":"17","author":"WA Osthaus","year":"2007","unstructured":"Osthaus WA, Huber D, Beck C, Winterhalter M, Boethig D, Wessel A et al. Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets. Paediatr Anaesth 2007; 17 (8): 749\u2013755.","journal-title":"Paediatr Anaesth"},{"issue":"10","key":"BFjp2014245_CR7","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1111\/j.1399-6576.2007.01445.x","volume":"51","author":"N Zoremba","year":"2007","unstructured":"Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Sch\u00e4lte G . Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand 2007; 51 (10): 1314\u20131319.","journal-title":"Acta Anaesthesiol Scand"},{"issue":"1","key":"BFjp2014245_CR8","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1093\/bja\/aem320","volume":"100","author":"K Norozi","year":"2008","unstructured":"Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H . Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth 2008; 100 (1): 88\u201394.","journal-title":"Br J Anaesth"},{"issue":"5","key":"BFjp2014245_CR9","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1093\/bja\/aei224","volume":"95","author":"C Schmidt","year":"2005","unstructured":"Schmidt C, Theilmeier G, Van Aken H, Korsmeier P, Wirtz SP, Berendes E et al. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br J Anaesth 2005; 95 (5): 603\u2013610.","journal-title":"Br J Anaesth"},{"issue":"10","key":"BFjp2014245_CR10","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1016\/j.echo.2011.07.014","volume":"24","author":"L Mertens","year":"2011","unstructured":"Mertens L, Seri I, Marek J, Arlettaz R, Barker P, McNamara P et al. Targeted Neonatal Echocardiography in the Neonatal Intensive Care Unit: practice guidelines and recommendations for training. Writing Group of the American Society of Echocardiography (ASE) in collaboration with the European Association of Echocardiography (EAE) and the Association for European Pediatric Cardiologists (AEPC). J Am Soc Echocardiogr 2011; 24 (10): 1057\u20131078.","journal-title":"J Am Soc Echocardiogr"},{"issue":"6","key":"BFjp2014245_CR11","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1097\/00003246-199906000-00053","volume":"27","author":"E Raaijmakers","year":"1999","unstructured":"Raaijmakers E, Faes TJ, Scholten RJ, Goovaerts HG, Heethaar RM . A meta-analysis of three decades of validating thoracic impedance cardiography. Crit Care Med 1999; 27 (6): 1203\u20131213.","journal-title":"Crit Care Med"},{"issue":"2","key":"BFjp2014245_CR12","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1023\/A:1009982611386","volume":"15","author":"LA Critchley","year":"1999","unstructured":"Critchley LA, Critchley JA . A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15 (2): 85\u201391.","journal-title":"J Clin Monit Comput"},{"issue":"8476","key":"BFjp2014245_CR13","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1 (8476): 307\u2013310.","journal-title":"Lancet"},{"issue":"1","key":"BFjp2014245_CR14","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1186\/cc7129","volume":"13","author":"M Cecconi","year":"2009","unstructured":"Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM . Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies -with specific reference to the measurement of cardiac output. Crit Care 2009; 13 (1): 201.","journal-title":"Crit Care"},{"issue":"3","key":"BFjp2014245_CR15","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1017\/S0265021507002669","volume":"25","author":"D Mekis","year":"2008","unstructured":"Mekis D, Kamenik M, Starc V, Jeretin S . Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery: a comparison with intermittent thermodilution. Eur J Anaesthesiol 2008; 25 (3): 237\u2013242.","journal-title":"Eur J Anaesthesiol"},{"issue":"6","key":"BFjp2014245_CR16","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1007\/s00134-012-2530-3","volume":"38","author":"O Grollmuss","year":"2012","unstructured":"Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E . Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med 2012; 38 (6): 1032\u20131039.","journal-title":"Intensive Care Med"},{"issue":"5","key":"BFjp2014245_CR17","doi-asserted-by":"publisher","first-page":"F340","DOI":"10.1136\/fetalneonatal-2011-301090","volume":"97","author":"S Noori","year":"2012","unstructured":"Noori S, Drabu B, Soleymani S, Seri I . Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography. Arch Dis Child Fetal Neonatal Ed 2012; 97 (5): F340\u2013F343.","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"4","key":"BFjp2014245_CR18","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1093\/bja\/aen024","volume":"100","author":"M Tomaske","year":"2008","unstructured":"Tomaske M, Knirsch W, Kretschmar O, Woitzek K, Balmer C, Schmitz A et al. Cardiac output measurement in children: comparison of Aesculon cardiac output monitor and thermodilution. Br J Anaesth 2008; 100 (4): 517\u2013520.","journal-title":"Br J Anaesth"},{"issue":"5","key":"BFjp2014245_CR19","doi-asserted-by":"publisher","first-page":"R193","DOI":"10.1186\/cc9310","volume":"14","author":"E Futier","year":"2010","unstructured":"Futier E, Robin E, Jabaudon M, Guerin R, Petit A, Bazin JE et al. Central venous O2 saturation and venous-to-arterial CO2 difference as complementary tools for goal-directed therapy during high-risk surgery. Crit Care 2010; 14 (5): R193.","journal-title":"Crit Care"},{"issue":"4","key":"BFjp2014245_CR20","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1159\/000339117","volume":"102","author":"DC Vijlbrief","year":"2012","unstructured":"Vijlbrief DC, Benders MJ, Kemperman H, van Bel F, de Vries WB . Cardiac biomarkers as indicators of hemodynamic adaptation during postasphyxial hypothermia treatment. Neonatology 2012; 102 (4): 243\u2013248.","journal-title":"Neonatology"},{"issue":"2 Pt 1","key":"BFjp2014245_CR21","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1542\/peds.104.2.280","volume":"104","author":"RA Ehrenkranz","year":"1999","unstructured":"Ehrenkranz RA, Younes N, Lemons JA, Fanaroff AA, Donovan EF, Wright LL et al. Longitudinal growth of hospitalized very low birth weight infants. Pediatrics 1999; 104 (2 Pt 1): 280\u2013289.","journal-title":"Pediatrics"},{"issue":"5","key":"BFjp2014245_CR22","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1542\/peds.79.5.702","volume":"79","author":"SG Shaffer","year":"1987","unstructured":"Shaffer SG, Quimiro CL, Anderson JV, Hall RT . Postnatal weight changes in low birth weight infants. Pediatrics 1987; 79 (5): 702\u2013705.","journal-title":"Pediatrics"}],"container-title":["Journal of Perinatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/jp2014245.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/jp2014245","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/jp2014245.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,18]],"date-time":"2022-03-18T09:15:47Z","timestamp":1647594947000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/jp2014245"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,1,29]]},"references-count":22,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2015,7]]}},"alternative-id":["BFjp2014245"],"URL":"https:\/\/doi.org\/10.1038\/jp.2014.245","relation":{},"ISSN":["0743-8346","1476-5543"],"issn-type":[{"value":"0743-8346","type":"print"},{"value":"1476-5543","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,1,29]]},"assertion":[{"value":"14 October 2014","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 December 2014","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 January 2015","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}