{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T23:10:31Z","timestamp":1785885031142,"version":"3.56.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2015,11,19]],"date-time":"2015-11-19T00:00:00Z","timestamp":1447891200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2015,11,19]],"date-time":"2015-11-19T00:00:00Z","timestamp":1447891200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Perinatol"],"published-print":{"date-parts":[[2016,2]]},"DOI":"10.1038\/jp.2015.173","type":"journal-article","created":{"date-parts":[[2015,11,19]],"date-time":"2015-11-19T14:03:33Z","timestamp":1447941813000},"page":"116-120","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Monitoring the respiratory rate by miniature motion sensors in premature infants: a comparative study"],"prefix":"10.1038","volume":"36","author":[{"given":"S","family":"Kohn","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D","family":"Waisman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J","family":"Pesin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A","family":"Faingersh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"I C","family":"Klotzman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G","family":"Hirshberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A","family":"Rotschild","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A","family":"Landesberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,11,19]]},"reference":[{"key":"BFjp2015173_CR1","first-page":"522","volume-title":"Fanaroff and Martin's Neonatal-Perinatal Medicine","author":"JM Di Fiore","year":"2015","unstructured":"Di Fiore JM . Biomedical engineering aspects of neonatal cardiorespiratory monitoring. In: Martin RJ, Fanaroff AA, Walsh MC (eds). Fanaroff and Martin's Neonatal-Perinatal Medicine. Saunders, Elsevier: Philadelphia, PA, USA, 2015, pp 522\u2013535."},{"key":"BFjp2015173_CR2","doi-asserted-by":"publisher","first-page":"2199","DOI":"10.1001\/jama.285.17.2199","volume":"285","author":"R Ramanathan","year":"2001","unstructured":"Ramanathan R, Corwin MJ, Hunt CE, Lister G, Tinsley LR, Baird T et al. Cardiorespiratory events recorded on home monitors: comparison of healthy infants with those at increased risk for SIDS. JAMA 2001; 285: 2199\u20132207.","journal-title":"JAMA"},{"key":"BFjp2015173_CR3","doi-asserted-by":"publisher","first-page":"1304","DOI":"10.1542\/peds.108.6.1304","volume":"108","author":"JM Di Fiore","year":"2001","unstructured":"Di Fiore JM, Arko MK, Miller MJ, Krauss A, Betkerur A, Zadell A et al. Cardiorespiratory events in preterm infants referred for apnea monitoring studies. Pediatrics 2001; 108: 1304\u20131308.","journal-title":"Pediatrics"},{"key":"BFjp2015173_CR4","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.1001\/jama.1980.03310100041029","volume":"244","author":"TR Gravelyn","year":"1980","unstructured":"Gravelyn TR, Weg JG . Respiratory rate as an indicator of acute respiratory dysfunction. JAMA 1980; 244: 1123\u20131125.","journal-title":"JAMA"},{"key":"BFjp2015173_CR5","doi-asserted-by":"crossref","first-page":"657","DOI":"10.5694\/j.1326-5377.2008.tb01825.x","volume":"188","author":"MA Cretikos","year":"2008","unstructured":"Cretikos MA, Bellomo R, Hillman K, Chen J, Finfer S, Flabouris A . Respiratory rate: the neglected vital sign. Med J Aust 2008; 188: 657\u2013659.","journal-title":"Med J Aust"},{"key":"BFjp2015173_CR6","doi-asserted-by":"publisher","first-page":"88","DOI":"10.4103\/0974-2700.43189","volume":"1","author":"JR Meredith","year":"2008","unstructured":"Meredith JR, O'Keefe KP, Galwankar S . Pediatric procedural sedation and analgesia. J Emerg Trauma Shock 2008; 1: 88\u201396.","journal-title":"J Emerg Trauma Shock"},{"key":"BFjp2015173_CR7","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/j.resuscitation.2009.12.008","volume":"81","author":"MA DeVita","year":"2010","unstructured":"DeVita MA, Smith GB, Adam SK, Adams-Pizarro I, Buist M, Bellomo R et al. 'Identifying the hospitalized patient in crisis'\u2014a consensus conference on the afferent limb of rapid response systems. Resuscitation 2010; 81: 375\u2013382.","journal-title":"Resuscitation"},{"key":"BFjp2015173_CR8","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.annemergmed.2004.06.016","volume":"45","author":"PB Lovett","year":"2005","unstructured":"Lovett PB, Buchwald JM, Stumann K, Bijur P . The vexatious vital: neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triage. Ann Emerg Med 2005; 45: 68\u201376.","journal-title":"Ann Emerg Med"},{"key":"BFjp2015173_CR9","first-page":"161","volume":"65","author":"JJ Freundlich","year":"1972","unstructured":"Freundlich JJ, Erickson JC . Electrical impedance pneumography for simple nonrestrictive continuous monitoring of respiratory rate, rhythm and tidal volume for surgical patients. Chest 1972; 65: 161\u2013165.","journal-title":"Chest"},{"key":"BFjp2015173_CR10","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1136\/emj.9.4.377","volume":"9","author":"D Haborne","year":"1992","unstructured":"Haborne D . Measuring respiratory rate. Arch Emerg Med 1992; 9: 377\u2013378.","journal-title":"Arch Emerg Med"},{"key":"BFjp2015173_CR11","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1007\/BF02348078","volume":"41","author":"M Folke","year":"2003","unstructured":"Folke M, Cernerud L, Ekstrom M, Hok B . Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput 2003; 41: 377\u2013383.","journal-title":"Med Biol Eng Comput"},{"key":"BFjp2015173_CR12","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.siny.2003.11.009","volume":"9","author":"JM Di Fiore","year":"2004","unstructured":"Di Fiore JM . Neonatal cardiorespiratory monitoring techniques. Semin Neonatol 2004; 9: 195\u2013203.","journal-title":"Semin Neonatol"},{"key":"BFjp2015173_CR13","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1002\/ppul.21416","volume":"46","author":"FQ Al-Khalidi","year":"2011","unstructured":"Al-Khalidi FQ, Saatchi R, Burke D, Elphick H, Tan S . Respiration rate monitoring methods: a review. Pediatr Pulmonol 2011; 46: 523\u2013529.","journal-title":"Pediatr Pulmonol"},{"key":"BFjp2015173_CR14","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1007\/s00134-011-2398-7","volume":"38","author":"D Waisman","year":"2012","unstructured":"Waisman D, Faingersh A, Levy C, Konyukhov E, Klotzman FI, Rotschild A et al. Early detection of deteriorating ventilation by monitoring bilateral chest wall dynamics in the rabbit. Intens Care Med 2012; 38: 120\u2013127.","journal-title":"Intens Care Med"},{"key":"BFjp2015173_CR15","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1007\/s00134-011-2228-y","volume":"37","author":"D Waisman","year":"2011","unstructured":"Waisman D, Levy C, Faingersh A, Klotzman FIC, Konyukhov E, Kessel I et al. A new method for continuous monitoring of the chest wall movement to characterize hypoxemic episodes during HFOV. Intens Care Med 2011; 37: 1174\u20131181.","journal-title":"Intens Care Med"},{"key":"BFjp2015173_CR16","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1007\/s00134-012-2749-z","volume":"39","author":"D Waisman","year":"2013","unstructured":"Waisman D, Faingersh A, Levy C, Colman-Klotzman I, Rotschild A, Lichtenstein O et al. Transient decrease in PaCO2 and asymmetric chest wall dynamics in early progressing pneumothorax. Intens Care Med 2013; 39: 137\u2013145.","journal-title":"Intens Care Med"},{"key":"BFjp2015173_CR17","doi-asserted-by":"publisher","first-page":"1632","DOI":"10.1152\/japplphysiol.00966.2013","volume":"116","author":"J Pesin","year":"2014","unstructured":"Pesin J, Faingersh A, Waisman D, Landesberg A . Highly sensitive monitoring of chest wall dynamics provides diverse and clinically valuable information for evaluating ventilation and diagnosing pneumothorax. J Appl Physiol 2014; 116: 1632\u20131640.","journal-title":"J Appl Physiol"},{"key":"BFjp2015173_CR18","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"327","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327: 307\u2013310.","journal-title":"Lancet"},{"key":"BFjp2015173_CR19","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/BF01132363","volume":"11","author":"M Vegfors","year":"1994","unstructured":"Vegfors M, Lindberg LG, Pettersson H, Oberg PA . Presentation and evaluation of a new optical sensor for respiratory rate monitoring. Int J Clin Monit Comput 1994; 11: 151\u2013156.","journal-title":"Int J Clin Monit Comput"},{"key":"BFjp2015173_CR20","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1542\/peds.99.5.681","volume":"99","author":"WR Mower","year":"1997","unstructured":"Mower WR, Sachs C, Nicklin EL, Baraff LJ . Pulse oximetry as a fifth pediatric vital sign. Pediatrics 1997; 99: 681\u2013686.","journal-title":"Pediatrics"},{"key":"BFjp2015173_CR21","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1378\/chest.94.2.227a","volume":"94","author":"TA Neff","year":"1988","unstructured":"Neff TA . Routine oximetry: a fifth vital sign? Chest 1988; 94: 227.","journal-title":"Chest"},{"key":"BFjp2015173_CR22","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1002\/ppul.22623","volume":"48","author":"S Chawla","year":"2013","unstructured":"Chawla S, Natarajan G, Gelmini M, Kazzi SN . Role of spontaneous breathing trial in predicting successful extubation in premature infants. Pediatr Pulmonol 2013; 48: 443\u2013448.","journal-title":"Pediatr Pulmonol"},{"key":"BFjp2015173_CR23","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/B978-1-4160-5624-9.00009-3","volume-title":"Assisted Ventilation of the Neonate","author":"AR Spitzer","year":"2011","unstructured":"Spitzer AR, Clark RH . Positive-pressure ventilation in the treatment of neonatal lung disease. In: Goldsmith JP, Karotkin EH (eds). Assisted Ventilation of the Neonate, 5th edn. Saunders: Philadelphia, PA, USA, 2011, pp 163\u2013185."},{"key":"BFjp2015173_CR24","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/B978-1-4160-5624-9.00013-5","volume-title":"Assisted Ventilation of the Neonate","author":"AR Spitzer","year":"2011","unstructured":"Spitzer AR, Clark RH . Special ventilation techniques II: lung protective strategies. In: Goldsmith JP, Karotkin EH (eds). Assisted Ventilation of the Neonate, 5th edn. Saunders: Philadelphia, PA, USA, 2011, pp 235\u2013248."},{"key":"BFjp2015173_CR25","doi-asserted-by":"publisher","first-page":"F70","DOI":"10.1136\/fetalneonatal-2011-301340","volume":"98","author":"J Kaczmarek","year":"2013","unstructured":"Kaczmarek J, Kamlin CO, Morley CJ, Davis PG, Sant'anna GM . Variability of respiratory parameters and extubation readiness in ventilated neonates. Arch Dis Child Fetal Neonatal Ed 2013; 98: F70\u2013F73.","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"BFjp2015173_CR26","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1186\/cc4993","volume":"10","author":"PC Rimensberger","year":"2006","unstructured":"Rimensberger PC . Allowing for spontaneous breathing during high-frequency oscillation: the key for final success? Crit Care 2006; 10: 155.","journal-title":"Crit Care"},{"key":"BFjp2015173_CR27","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1111\/j.1365-2044.2009.05908.x","volume":"64","author":"JN Wilkinson","year":"2009","unstructured":"Wilkinson JN, Thanawala VU . Thoracic impedance monitoring of respiratory rate during sedation\u2014is it safe? Anesthesia 2009; 64: 455\u2013456.","journal-title":"Anesthesia"}],"container-title":["Journal of Perinatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/jp2015173.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/jp2015173","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/jp2015173.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,9]],"date-time":"2025-04-09T01:57:15Z","timestamp":1744163835000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/jp2015173"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,19]]},"references-count":27,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,2]]}},"alternative-id":["BFjp2015173"],"URL":"https:\/\/doi.org\/10.1038\/jp.2015.173","relation":{},"ISSN":["0743-8346","1476-5543"],"issn-type":[{"value":"0743-8346","type":"print"},{"value":"1476-5543","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,19]]},"assertion":[{"value":"29 September 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2015","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2015","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"SK, DW, JP, GH, AF, ICK, CL and AL are involved in the development of a respiratory function monitor in a collaborative effort between the Technion \u2013 Israel Institute of Technology, Clalit Health Services and Pneumedicare. AR does not have a conflict of interest to declare.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}