{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T04:44:49Z","timestamp":1789879489764,"version":"4.0.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2016,4,21]],"date-time":"2016-04-21T00:00:00Z","timestamp":1461196800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2016,4,21]],"date-time":"2016-04-21T00:00:00Z","timestamp":1461196800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Perinatol"],"published-print":{"date-parts":[[2016,9]]},"DOI":"10.1038\/jp.2016.65","type":"journal-article","created":{"date-parts":[[2016,4,21]],"date-time":"2016-04-21T09:02:51Z","timestamp":1461229371000},"page":"748-752","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":54,"title":["Stroke volume and cardiac output evaluation by electrical cardiometry: accuracy and reference nomograms in hemodynamically stable preterm neonates"],"prefix":"10.1038","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1510-3347","authenticated-orcid":false,"given":"A","family":"Boet","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G","family":"Jourdain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S","family":"Demontoux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D","family":"De Luca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,4,21]]},"reference":[{"key":"BFjp201665_CR1","first-page":"1208","volume":"37","author":"WG Kubicek","year":"1966","unstructured":"Kubicek WG, Karnegis JN, Patterson RP, Witsoe DA, Mattson RH . Development and evaluation of an impedance cardiac output system. Aerosp Med 1966; 37: 1208\u20131212.","journal-title":"Aerosp Med"},{"key":"BFjp201665_CR2","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1097\/00044067-199908000-00008","volume":"10","author":"MJ Osypka","year":"1999","unstructured":"Osypka MJ, Bernstein DP . Electrophysiologic principles and theory of stroke volume determination by thoracic electrical bioimpedance. AACN Clin Issues 1999; 10: 385\u2013399.","journal-title":"AACN Clin Issues"},{"key":"BFjp201665_CR3","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1007\/BF02344724","volume":"43","author":"DP Bernstein","year":"2005","unstructured":"Bernstein DP, Lemmens HJ . Stroke volume equation for impedance cardiography. Med Biol Eng Comput 2005; 43: 443\u2013450.","journal-title":"Med Biol Eng Comput"},{"key":"BFjp201665_CR4","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1111\/j.1460-9592.2007.02210.x","volume":"17","author":"WA Osthaus","year":"2007","unstructured":"Osthaus WA, Huber D, Beck C, Winterhalter M, Boethig D, Wessel A et al. Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets. Paediatr Anaesth 2007; 17: 749\u2013755.","journal-title":"Paediatr Anaesth"},{"key":"BFjp201665_CR5","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1093\/bja\/aem320","volume":"100","author":"K Norozi","year":"2008","unstructured":"Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H . Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth 2008; 100: 88\u201394.","journal-title":"Br J Anaesth"},{"key":"BFjp201665_CR6","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1007\/s10877-008-9133-0","volume":"22","author":"S Schubert","year":"2008","unstructured":"Schubert S, Schmitz T, Weiss M, Nagdyman N, Huebler M, Alexi-Meskishvili V et al. Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry. J Clin Monit Comput 2008; 22: 299\u2013307.","journal-title":"J Clin Monit Comput"},{"key":"BFjp201665_CR7","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1097\/EJA.0b013e3283240438","volume":"26","author":"M Tomaske","year":"2009","unstructured":"Tomaske M, Knirsch W, Kretschmar O, Balmer C, Woitzek K, Schmitz A et al. Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defects. Eur J Anaesthesiol 2009; 26: 412\u2013415.","journal-title":"Eur J Anaesthesiol"},{"key":"BFjp201665_CR8","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1017\/S0265021507002669","volume":"25","author":"D Mekis","year":"2008","unstructured":"Mekis D, Kamenik M, Starc V, Jeretin S . Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery: a comparison with intermittent thermodilution. Eur J Anaesthesiol 2008; 25: 237\u2013242.","journal-title":"Eur J Anaesthesiol"},{"key":"BFjp201665_CR9","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1093\/bja\/aei224","volume":"95","author":"C Schmidt","year":"2005","unstructured":"Schmidt C, Theilmeier G, Van Aken H, Korsmeier P, Wirtz SP, Berendes E et al. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br J Anaesth 2005; 95: 603\u2013610.","journal-title":"Br J Anaesth"},{"key":"BFjp201665_CR10","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1007\/s00134-012-2530-3","volume":"38","author":"O Grollmuss","year":"2012","unstructured":"Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E . Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med 2012; 38: 1032\u20131039.","journal-title":"Intensive Care Med"},{"key":"BFjp201665_CR11","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1111\/j.1399-6576.2007.01445.x","volume":"51","author":"N Zoremba","year":"2007","unstructured":"Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Sch\u00e4lte G . Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand 2007; 51: 1314\u20131319.","journal-title":"Acta Anaesthesiol Scand"},{"key":"BFjp201665_CR12","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.jclinane.2011.02.014","volume":"24","author":"TL Archer","year":"2012","unstructured":"Archer TL, Conrad BE, Suresh P, Tarsa M . Electrical velocimetry demonstrates the increase in cardiac output and decrease in systemic vascular resistance accompanying cesarean delivery and oxytocin administration. J Clin Anesth 2012; 24: 79\u201382.","journal-title":"J Clin Anesth"},{"key":"BFjp201665_CR13","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1007\/s10877-012-9412-7","volume":"27","author":"R Rauch","year":"2013","unstructured":"Rauch R, Welisch E, Lansdell N, Burrill E, Jones J, Robinson T et al. Non-invasive measurement of cardiac output in obese children and adolescents: comparison of electrical cardiometry and transthoracic Doppler echocardiography. J Clin Monit Comput 2013; 27: 187\u2013193.","journal-title":"J Clin Monit Comput"},{"issue":"6","key":"BFjp201665_CR14","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1186\/s13054-014-0603-0","volume":"18","author":"M Blohm","year":"2014","unstructured":"Blohm M, Obrecht D, Hartwich J, Mueller G, Kersten J, Weil J et al. Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study. Crit Care 2014; 18 (6): 603.","journal-title":"Crit Care"},{"issue":"5","key":"BFjp201665_CR15","doi-asserted-by":"publisher","first-page":"F340","DOI":"10.1136\/fetalneonatal-2011-301090","volume":"97","author":"Shahab Noori","year":"2012","unstructured":"Noori S, Drabu B, Soleymani S, Seri I. Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography. Arch Dis Child Fetal Neonatal Ed 2012; 97: F340\u2013F343.","journal-title":"Archives of Disease in Childhood - Fetal and Neonatal Edition"},{"key":"BFjp201665_CR16","doi-asserted-by":"publisher","first-page":"16","DOI":"10.3389\/fped.2014.00016","volume":"2","author":"O Grollmuss","year":"2014","unstructured":"Grollmuss O, Gonzalez P . Non-invasive cardiac output measurement in low and very low birth weight infants: a method comparison. Front Pediatr 2014; 2: 16.","journal-title":"Front Pediatr"},{"issue":"4","key":"BFjp201665_CR17","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1007\/s00431-014-2437-9","volume":"174","author":"R Lien","year":"2014","unstructured":"Lien R, Hsu KH, Chu JJ, Chang YS . Hemodynamic alterations recorded by electrical cardiometry during ligation of ductus arteriosus in preterm infants. Eur J Pediatr 2014; 174 (4): 543\u2013550.","journal-title":"Eur J Pediatr"},{"key":"BFjp201665_CR18","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1097\/01.PCC.0000149131.72248.E6","volume":"6","author":"B Goldstein","year":"2005","unstructured":"Goldstein B, Giroir B, Randolph A, International Consensus Conference on Pediatric Sepsis. International pediatric sepsis consensus conference: definitions for sepsis and organ dysfunction in paediatrics. Pediatr Crit Care Med 2005; 6: 2\u20138.","journal-title":"Pediatr Crit Care Med"},{"key":"BFjp201665_CR19","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307\u2013310.","journal-title":"Lancet"},{"key":"BFjp201665_CR20","volume-title":"SPSS 13.0 Advanced Statistical Procedures Companion","author":"M Norusis","year":"2004","unstructured":"Norusis M . SPSS 13.0 Advanced Statistical Procedures Companion. Prentice Hall Inc.: Upper Saddle River, NJ, USA, 2004."},{"key":"BFjp201665_CR21","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1080\/01621459.1979.10481038","volume":"74","author":"WS Cleveland","year":"1979","unstructured":"Cleveland WS . Robust locally weighted regression and smoothing scatterplots. J Am Stat Assoc 1979; 74: 829\u2013836.","journal-title":"J Am Stat Assoc"},{"key":"BFjp201665_CR22","doi-asserted-by":"publisher","first-page":"F135","DOI":"10.1136\/adc.2007.121053","volume":"93","author":"D De Luca","year":"2008","unstructured":"De Luca D, Zecca E, Corsello M, Tiberi E, Semeraro C, Romagnoli C . Attempt to improve transcutaneous bilirubinometry: a double-blind study of Medick BiliMed versus Respironics BiliCheck. Arch Dis Child Fetal Neonatal Ed 2008; 93: F135\u2013F139.","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"BFjp201665_CR23","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1016\/S0304-4076(96)01818-0","volume":"77","author":"AC Cameron","year":"1997","unstructured":"Cameron AC, Windmeijer FAG . An R-squared measure of goodness of fit for some common nonlinear regression models. J Econom 1997; 77: 329\u2013342.","journal-title":"J Econom"},{"issue":"12","key":"BFjp201665_CR24","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1055\/s-0034-1371707","volume":"31","author":"R Song","year":"2014","unstructured":"Song R, Rich W, Kim JH, Finer NN, Katheria AC . The use of electrical cardiometry for continuous cardiac output monitoring in preterm neonates: a validation study. Am J Perinatol 2014; 31 (12): 1105\u20131110.","journal-title":"Am J Perinatol"},{"issue":"1","key":"BFjp201665_CR25","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1186\/cc7129","volume":"13","author":"M Cecconi","year":"2009","unstructured":"Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM . Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies\u2014with specific reference to the measurement of cardiac output. Crit Care 2009; 13 (1): 201.","journal-title":"Crit Care"}],"container-title":["Journal of Perinatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/jp201665.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/jp201665","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/jp201665.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,18]],"date-time":"2022-03-18T11:08:16Z","timestamp":1647601696000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/jp201665"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4,21]]},"references-count":25,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2016,9]]}},"alternative-id":["BFjp201665"],"URL":"https:\/\/doi.org\/10.1038\/jp.2016.65","relation":{},"ISSN":["0743-8346","1476-5543"],"issn-type":[{"value":"0743-8346","type":"print"},{"value":"1476-5543","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,4,21]]},"assertion":[{"value":"27 November 2015","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 March 2016","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2016","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}