{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T05:36:34Z","timestamp":1792733794495,"version":"4.5.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2004,10,24]],"date-time":"2004-10-24T00:00:00Z","timestamp":1098576000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2004,10,24]],"date-time":"2004-10-24T00:00:00Z","timestamp":1098576000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Nature Mater"],"published-print":{"date-parts":[[2004,11,1]]},"DOI":"10.1038\/nmat1233","type":"journal-article","created":{"date-parts":[[2004,10,24]],"date-time":"2004-10-24T17:29:35Z","timestamp":1098638975000},"page":"829-836","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":552,"title":["Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis"],"prefix":"10.1038","volume":"3","author":[{"given":"Toru","family":"Moro","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshio","family":"Takatori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuhiko","family":"Ishihara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomohiro","family":"Konno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yorinobu","family":"Takigawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomiharu","family":"Matsushita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ung-il","family":"Chung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kozo","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Kawaguchi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2004,10,24]]},"reference":[{"key":"BFnmat1233_CR1","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1097\/00003086-200112000-00007","volume":"393","author":"WH Harris","year":"2001","unstructured":"Harris, W. H. Wear and periprosthetic osteolysis: the problem. Clin. Orthop. 393, 66\u201370 (2001).","journal-title":"Clin. Orthop."},{"key":"BFnmat1233_CR2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1097\/00003086-200112000-00008","volume":"393","author":"JJ Jacobs","year":"2001","unstructured":"Jacobs, J. J., Roebuck, K. A., Archibeck, M., Hallab, N. J. & Glant, T. T. Osteolysis: basic science. Clin. Orthop. 393, 71\u201377 (2001).","journal-title":"Clin. Orthop."},{"key":"BFnmat1233_CR3","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1002\/jor.1100020202","volume":"2","author":"GM Connelly","year":"1984","unstructured":"Connelly, G. M., Rimnac, C. M., Wright, T. M., Hertzberg, R. W. & Manson, J. A. Fatigue crack propagation behavior of ultrahigh molecular weight polyethylene. J. Orthop. Res. 2, 119\u2013125 (1984).","journal-title":"J. Orthop. Res."},{"key":"BFnmat1233_CR4","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1016\/j.orthres.2003.08.013","volume":"22","author":"M von Knoch","year":"2004","unstructured":"von Knoch, M. et al. The effectiveness of polyethylene versus titanium particles in inducing osteolysis in vivo. J. Orthop. Res. 22, 237\u2013243 (2004).","journal-title":"J. Orthop. Res."},{"key":"BFnmat1233_CR5","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.2106\/00004623-199509000-00002","volume":"77","author":"WJ Maloney","year":"1995","unstructured":"Maloney, W. J. et al. Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. J. Bone Joint Surg. Am. 77, 1301\u20131310 (1995).","journal-title":"J. Bone Joint Surg. Am."},{"key":"BFnmat1233_CR6","doi-asserted-by":"publisher","first-page":"1071","DOI":"10.1002\/jbmr.5650080907","volume":"8","author":"TT Glant","year":"1993","unstructured":"Glant, T. T. et al. Bone resorption activity of particulate-stimulated macrophages. J. Bone Miner. Res. 8, 1071\u20131079 (1993).","journal-title":"J. Bone Miner. Res."},{"key":"BFnmat1233_CR7","doi-asserted-by":"publisher","first-page":"192","DOI":"10.1359\/jbmr.2002.17.2.192","volume":"17","author":"LM Childs","year":"2002","unstructured":"Childs, L. M. et al. In vivo RANK signaling blockade using the receptor activator of NF-\u03baB:Fc effectively prevents and ameliorates wear debris-induced osteolysis via osteoclast depletion without inhibiting osteogenesis. J. Bone Miner. Res. 17, 192\u2013199 (2002).","journal-title":"J. Bone Miner. Res."},{"key":"BFnmat1233_CR8","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/S0736-0266(01)00083-3","volume":"20","author":"JJ Goater","year":"2002","unstructured":"Goater, J. J., O'Keefe, R. J., Rosier, R. N., Puzas, J. E. & Schwarz, E. M. Efficacy of ex vivo OPG gene therapy in preventing wear debris induced osteolysis. J. Orthop. Res. 20, 169\u2013173 (2002).","journal-title":"J. Orthop. Res."},{"key":"BFnmat1233_CR9","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1295\/polymj.22.355","volume":"22","author":"K Ishihara","year":"1990","unstructured":"Ishihara, K., Ueda, T. & Nakabayashi, N. Preparation of phospholipid polymers and their properties as polymer hydrogel membrane. Polym. J. 22, 355\u2013360 (1990).","journal-title":"Polym. J."},{"key":"BFnmat1233_CR10","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1163\/156856299X00342","volume":"10","author":"K Ishihara","year":"1999","unstructured":"Ishihara, K., Shinozuka, T., Hanazaki, Y., Iwasaki, Y. & Nakabayashi, N. Improvement of blood compatibility on cellulose hemodialysis membrane: IV. Phospholipid polymer bonded to the membrane surface. J. Biomater. Sci. Polym. Edn 10, 271\u2013282 (1999).","journal-title":"J. Biomater. Sci. Polym. Edn"},{"key":"BFnmat1233_CR11","doi-asserted-by":"publisher","first-page":"1455","DOI":"10.1016\/S0142-9612(01)00268-X","volume":"23","author":"T Yoneyama","year":"2002","unstructured":"Yoneyama, T., Sugihara, K., Ishihara, K., Iwasaki, Y. & Nakabayashi, N. The vascular prosthesis without pseudointima prepared by antithrombogenic phospholipid polymer. Biomaterials 23, 1455\u20131459 (2002).","journal-title":"Biomaterials"},{"key":"BFnmat1233_CR12","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1046\/j.1525-1594.2003.t01-2-06993.x","volume":"27","author":"S Kihara","year":"2003","unstructured":"Kihara, S. et al. In vivo evaluation of a MPC polymer coated continuous flow left ventricular assist system. Artif. Organs 27, 188\u2013192 (2003).","journal-title":"Artif. Organs"},{"key":"BFnmat1233_CR13","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/S0927-7765(99)00152-6","volume":"18","author":"AL Lewis","year":"2000","unstructured":"Lewis, A. L. Phosphorylcholine-based polymers and their use in the prevention of biofouling. Colloids Surf. B 18, 261\u2013275 (2000).","journal-title":"Colloids Surf. B"},{"key":"BFnmat1233_CR14","doi-asserted-by":"publisher","first-page":"1697","DOI":"10.1016\/S0142-9612(01)00297-6","volume":"23","author":"AL Lewis","year":"2002","unstructured":"Lewis, A. L., Tolhurst, L. A. & Stratford, P. W. Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation. Biomaterials 23, 1697\u20131706 (2002).","journal-title":"Biomaterials"},{"key":"BFnmat1233_CR15","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/S0927-7765(99)00158-7","volume":"18","author":"K Ishihara","year":"2000","unstructured":"Ishihara, K., Iwasaki, Y., Ebihara, S., Shindo, Y. & Nakabayashi, N. Photoinduced graft polymerization of 2-methacryloyloxyethyl phosphorylcholine on polyethylene membrane surface for obtaining blood cell adhesion resistance. Colloids Surf. B 18, 325\u2013335 (2000).","journal-title":"Colloids Surf. B"},{"key":"BFnmat1233_CR16","doi-asserted-by":"publisher","first-page":"823","DOI":"10.4028\/www.scientific.net\/KEM.240-242.823","volume":"240\u2013242","author":"T Nakamura","year":"2003","unstructured":"Nakamura, T. et al. Clinical and laboratory wear studies of zirconia-on-UHMWPE combination in cementless THA. Key Eng. Mater. 240\u2013242, 823\u2013826 (2003).","journal-title":"Key Eng. Mater."},{"key":"BFnmat1233_CR17","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1097\/00003086-199906000-00018","volume":"363","author":"DH Sochart","year":"1999","unstructured":"Sochart, D. H. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin. Orthop. 363, 135\u2013150 (1999).","journal-title":"Clin. Orthop."},{"key":"BFnmat1233_CR18","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1243\/PIME_PROC_1993_207_268_02","volume":"207","author":"PF Williams 3rd","year":"1993","unstructured":"Williams, P. F. 3rd, Powell, G. L. & LaBerge, M. Sliding friction analysis of phosphatidylcholine as a boundary lubricant for articular cartilage. Proc. Inst. Mech. Eng. H 207, 59\u201366 (1993).","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"BFnmat1233_CR19","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1243\/0954411001535264","volume":"214","author":"BA Hills","year":"2000","unstructured":"Hills, B. A. Boundary lubrication in vivo. Proc. Inst. Mech. Eng. H 214, 83\u201394 (2000).","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"BFnmat1233_CR20","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1243\/EMED_JOUR_1986_015_019_02","volume":"15","author":"D Dowson","year":"1986","unstructured":"Dowson, D. & Jin, Z. M. Micro-elastohydrodynamic lubrication of synovial joints. Eng. Med. 15, 63\u201365 (1986).","journal-title":"Eng. Med."},{"key":"BFnmat1233_CR21","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1002\/(SICI)1097-4636(199802)39:2<323::AID-JBM21>3.0.CO;2-C","volume":"39","author":"K Ishihara","year":"1998","unstructured":"Ishihara, K. et al. Why do phospholipid polymers reduce protein adsorption? J. Biomed. Mater. Res. 39, 323\u2013330 (1998).","journal-title":"J. Biomed. Mater. Res."},{"key":"BFnmat1233_CR22","doi-asserted-by":"publisher","first-page":"S244","DOI":"10.1097\/00003086-199608001-00021","volume":"329","author":"J Black","year":"1996","unstructured":"Black, J. Metal on metal bearings. A practical alternative to metal on polyethylene total joints? Clin. Orthop. 329, S244\u2013S255 (1996).","journal-title":"Clin. Orthop."},{"key":"BFnmat1233_CR23","doi-asserted-by":"publisher","first-page":"855","DOI":"10.1016\/S0883-5403(05)80087-7","volume":"10","author":"GH Callaway","year":"1995","unstructured":"Callaway, G. H., Flynn, W., Ranawat, C. S. & Sculco, T. P. Fracture of the femoral head after ceramic-on-polyethylene total hip arthroplasty. J. Arthroplasty 10, 855\u2013859 (1995).","journal-title":"J. Arthroplasty"},{"key":"BFnmat1233_CR24","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.2106\/00004623-198870090-00006","volume":"70","author":"TM Wright","year":"1988","unstructured":"Wright, T. M., Rimnac, C. M., Faris, P. M. & Bansal, M. Analysis of surface damage in retrieved carbon fiber-reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements. J. Bone Joint Surg. Am. 70, 1312\u20131319 (1988).","journal-title":"J. Bone Joint Surg. Am."},{"key":"BFnmat1233_CR25","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.2106\/00004623-199710000-00010","volume":"79","author":"BJ Livingston","year":"1997","unstructured":"Livingston, B. J., Chmell, M. J., Spector, M. & Poss, R. Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner. J. Bone Joint Surg. Am. 79, 1529\u20131538 (1997).","journal-title":"J. Bone Joint Surg. Am."},{"key":"BFnmat1233_CR26","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1016\/S0142-9612(99)00053-8","volume":"20","author":"SM Kurtz","year":"1999","unstructured":"Kurtz, S. M., Muratoglu, O. K., Evans, M. & Edidin, A. A. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 20, 1659\u20131688 (1999).","journal-title":"Biomaterials"},{"key":"BFnmat1233_CR27","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1097\/00003086-199912000-00008","volume":"369","author":"H McKellop","year":"1999","unstructured":"McKellop, H., Shen, F. W., DiMaio, W. & Lancaster, J. G. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clin. Orthop. 369, 73\u201382 (1999).","journal-title":"Clin. Orthop."},{"key":"BFnmat1233_CR28","doi-asserted-by":"publisher","first-page":"3511","DOI":"10.1016\/j.biomaterials.2003.10.054","volume":"25","author":"JH Ingram","year":"2004","unstructured":"Ingram, J. H., Stone, M., Fisher, J. & Ingham, E. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles. Biomaterials 25, 3511\u20133522 (2004).","journal-title":"Biomaterials"},{"key":"BFnmat1233_CR29","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1016\/S0142-9612(00)00373-2","volume":"22","author":"T Konno","year":"2001","unstructured":"Konno, T., Kurita, K., Iwasaki, Y., Nakabayashi, N. & Ishihara, K. Preparation of nanoparticles composed with bioinspired 2-methacryloyloxyethyl phosphorylcholine polymer. Biomaterials 22, 1883\u20131889 (2001).","journal-title":"Biomaterials"},{"key":"BFnmat1233_CR30","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1210\/endo-125-3-1142","volume":"125","author":"BF Boyce","year":"1989","unstructured":"Boyce, B. F., Aufdemorte, T. B., Garrett, I. R., Yates, A. J. & Mundy, G. R. Effects of interleukin-1 on bone turnover in normal mice. Endocrinology 125, 1142\u20131150 (1989).","journal-title":"Endocrinology"},{"key":"BFnmat1233_CR31","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1002\/jbm.820290118","volume":"29","author":"P Campbell","year":"1995","unstructured":"Campbell, P. et al. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues. J. Biomed. Mater. Res. 29, 127\u2013131 (1995).","journal-title":"J. Biomed. Mater. Res."},{"key":"BFnmat1233_CR32","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1002\/9780470294802.ch39","volume":"24","author":"K Jono","year":"2003","unstructured":"Jono, K., Takigawa, Y., Takadama, H., Mizuno, M. & Nakamura, T. A multi-station hip joint simulator study and wear characterization of commercial hip endoprostheses. Ceram. Eng. Sci. Proc. 24, 255\u2013260 (2003).","journal-title":"Ceram. Eng. Sci. Proc."},{"key":"BFnmat1233_CR33","doi-asserted-by":"publisher","first-page":"201","DOI":"10.2106\/00004623-200102000-00007","volume":"83","author":"C Vermes","year":"2001","unstructured":"Vermes, C. et al. The effects of particulate wear debris, cytokines, and growth factors on the functions of MG-63 osteoblasts. J. Bone Joint Surg. Am. A 83, 201\u2013211 (2001).","journal-title":"J. Bone Joint Surg. Am. A"},{"key":"BFnmat1233_CR34","doi-asserted-by":"publisher","first-page":"107","DOI":"10.2106\/00004623-199701000-00011","volume":"79","author":"J Yao","year":"1997","unstructured":"Yao, J., Cs-Szabo, G., Jacobs, J. J., Kuettner, K. E. & Glant, T. T. Suppression of osteoblast function by titanium particles. J. Bone Joint Surg. Am. 79, 107\u2013112 (1997).","journal-title":"J. Bone Joint Surg. Am."},{"key":"BFnmat1233_CR35","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1097\/00003086-200207000-00016","volume":"400","author":"K Inagaki","year":"2002","unstructured":"Inagaki, K. et al. Importance of a radial head component in Sorbie unlinked total elbow arthroplasty. Clin. Orthop. 400, 123\u2013131 (2002).","journal-title":"Clin. Orthop."},{"key":"BFnmat1233_CR36","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1002\/(SICI)1097-4636(2000)53:1<100::AID-JBM14>3.0.CO;2-4","volume":"53","author":"AS Shanbhag","year":"2000","unstructured":"Shanbhag, A. S. et al. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. J. Biomed. Mater. Res. 53, 100\u2013110 (2000).","journal-title":"J. Biomed. Mater. Res."},{"key":"BFnmat1233_CR37","first-page":"8","volume":"181","author":"JP Paul","year":"1967","unstructured":"Paul, J. P. Forces transmitted by joints in the human body. Proc. Inst. Mech. Eng. 181, 8\u201315 (1967).","journal-title":"Proc. Inst. Mech. Eng."},{"key":"BFnmat1233_CR38","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/0304-3959(83)90201-4","volume":"16","author":"M Zimmermann","year":"1983","unstructured":"Zimmermann, M. Ethical guidelines for investigations of experimental pain in conscious animals. Pain 16, 109\u2013110 (1983).","journal-title":"Pain"},{"key":"BFnmat1233_CR39","doi-asserted-by":"publisher","first-page":"935","DOI":"10.1172\/JCI9017","volume":"105","author":"N Ogata","year":"2000","unstructured":"Ogata, N. et al. Insulin receptor substrate-1 in osteoblast is indispensable for maintaining bone turnover. J. Clin. Invest. 105, 935\u2013943 (2000).","journal-title":"J. Clin. Invest."}],"container-title":["Nature Materials"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/nmat1233.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/nmat1233","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/nmat1233.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,6]],"date-time":"2022-07-06T20:27:31Z","timestamp":1657139251000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/nmat1233"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,10,24]]},"references-count":39,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2004,11,1]]}},"alternative-id":["BFnmat1233"],"URL":"https:\/\/doi.org\/10.1038\/nmat1233","relation":{},"ISSN":["1476-1122","1476-4660"],"issn-type":[{"value":"1476-1122","type":"print"},{"value":"1476-4660","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,10,24]]},"assertion":[{"value":"13 April 2004","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2004","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 October 2004","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing financial interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}