{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T11:14:52Z","timestamp":1789989292750,"version":"4.0.1"},"reference-count":158,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2012,5,8]],"date-time":"2012-05-08T00:00:00Z","timestamp":1336435200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Nat Rev Gastroenterol Hepatol"],"published-print":{"date-parts":[[2012,7]]},"DOI":"10.1038\/nrgastro.2012.88","type":"journal-article","created":{"date-parts":[[2012,5,8]],"date-time":"2012-05-08T10:29:57Z","timestamp":1336472997000},"page":"392-405","source":"Crossref","is-referenced-by-count":55,"title":["New vision in video capsule endoscopy: current status and future directions"],"prefix":"10.1038","volume":"9","author":[{"given":"Laurel R.","family":"Fisher","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"William L.","family":"Hasler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2012,5,8]]},"reference":[{"key":"BFnrgastro201288_CR1","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1016\/j.gie.2009.09.031","volume":"71","author":"Z Liao","year":"2010","unstructured":"Liao, Z., Gao, R., Xu, C. & Li, Z. S. Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointest. Endosc. 71, 280\u2013286 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR2","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1038\/nrgastro.2009.69","volume":"6","author":"A Moglia","year":"2009","unstructured":"Moglia, A., Menciassi, A., Dario, P. & Cuschieri, A. Capsule endoscopy: progress update and challenges ahead. Nat. Rev. Gastroenterol. Hepatol. 6, 353\u2013362 (2009).","journal-title":"Nat. Rev. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR3","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1038\/35013140","volume":"405","author":"G Iddan","year":"2000","unstructured":"Iddan, G., Meron, G., Glukhovsky, A. & Swain, P. Wireless capsule endoscopy. Nature 405, 417 (2000).","journal-title":"Nature"},{"key":"BFnrgastro201288_CR4","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1007\/s00261-008-9431-5","volume":"34","author":"M Waterman","year":"2009","unstructured":"Waterman, M. & Eliakim, R. Capsule enteroscopy of the small intestine. Abdom. Imaging 34, 452\u2013458 (2009).","journal-title":"Abdom. Imaging"},{"key":"BFnrgastro201288_CR5","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1016\/j.gie.2007.12.037","volume":"68","author":"DR Cave","year":"2008","unstructured":"Cave, D. R. et al. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest. Endosc. 68, 487\u2013494 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR6","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1038\/nrgastro.2011.152","volume":"8","author":"R Kiesslich","year":"2011","unstructured":"Kiesslich, R., Goetz, M., Hoffman, A. & Galle, P. R. New imaging techniques and opportunities in endoscopy. Nat. Rev. Gastroenterol. Hepatol. 8, 547\u2013553 (2011).","journal-title":"Nat. Rev. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR7","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1111\/j.1572-0241.2007.01670.x","volume":"103","author":"J Pohl","year":"2008","unstructured":"Pohl, J. et al. Computed virtural chromoendoscopy for classification of small colorectal lesions: a prospective comparative study. Am. J. Gastroenterol. 103, 562\u2013569 (2008).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR8","first-page":"299","volume":"73","author":"H Imagawa","year":"2011","unstructured":"Imagawa, H. et al. Improved visibility of lesions of the small intestine via capsule endoscopy with computed virtual chromoendoscopy. Clin. Endosc. 73, 299\u2013306 (2011).","journal-title":"Clin. Endosc."},{"key":"BFnrgastro201288_CR9","doi-asserted-by":"publisher","first-page":"1274","DOI":"10.1016\/j.gie.2011.01.073","volume":"73","author":"H Aihara","year":"2011","unstructured":"Aihara, H., Ikeda, K. & Tajiri, H. Image-enhanced capsule endoscopy based on the diagnosis of vascularity when using a new type of capsule. Gastrointest. Endosc. 73, 1274\u20131279 (2011).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR10","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/S0016-5107(04)02587-8","volume":"61","author":"PN D'Halluin","year":"2005","unstructured":"D'Halluin, P. N. et al. Does the \u201csuspected blood indicator\u201d improve the detection of bleeding lesions by capsule endoscopy? Gastrointest. Endosc. 61, 243\u2013249 (2005).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR11","doi-asserted-by":"publisher","first-page":"1769","DOI":"10.1007\/s10620-010-1500-2","volume":"56","author":"SC Park","year":"2011","unstructured":"Park, S. C. et al. Effect of bowel preparation with polyethylene glycol on quality of capsule endoscopy. Dig. Dis. Sci. 56, 1769\u20131775 (2011).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR12","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1111\/j.1440-1746.2009.05968.x","volume":"25","author":"S Nouda","year":"2010","unstructured":"Nouda, S. et al. Usefulness of polyethylene glycol solution with dimethylpolysiloxanes for bowel preparation before capsule endoscopy. J. Gastroenterol. Hepatol. 25, 70\u201374 (2010).","journal-title":"J. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR13","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1111\/j.1572-0241.2007.01633.x","volume":"103","author":"W Wei","year":"2008","unstructured":"Wei, W. et al. Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging. Am. J. Gastroenterol. 103, 77\u201382 (2008).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR14","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1038\/ajg.2008.63","volume":"104","author":"T Rokkas","year":"2009","unstructured":"Rokkas, T., Papaxoinis, K., Triantafyllou, K., Pistiolas, D. & Ladas, S. D. Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy? A meta-analysis. Am. J. Gastroenterol. 104, 219\u2013227 (2009).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR15","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1055\/s-0030-1256228","volume":"43","author":"SJ Van Weyenberg","year":"2011","unstructured":"Van Weyenberg, S. J., De Leest, H. T. & Mulder, C. J. Description of a novel grading system to assess the quality of bowel preparation in video capsule endoscopy. Endoscopy 43, 406\u2013411 (2011).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR16","doi-asserted-by":"publisher","first-page":"5329","DOI":"10.3748\/wjg.v16.i42.5329","volume":"16","author":"MM Lee","year":"2010","unstructured":"Lee, M. M. et al. Factors associated with incomplete small bowel capsule endoscopy studies. World J. Gastroenterol. 16, 5329\u20135333 (2010).","journal-title":"World J. Gastroenterol."},{"key":"BFnrgastro201288_CR17","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.gie.2008.04.034","volume":"69","author":"J Westerhof","year":"2009","unstructured":"Westerhof, J., Weersma, R. K. & Koornstra, J. J. Risk factors for incomplete small-bowel capsule endoscopy. Gastrointest. Endosc. 69, 74\u201380 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR18","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1007\/s10620-010-1419-7","volume":"56","author":"G Scaglione","year":"2011","unstructured":"Scaglione, G. et al. Age and video capsule endoscopy in obscure gastrointestinal bleeding: a prospective study on hospitalized patients. Dig. Dis. Sci. 56, 1188\u20131193 (2011).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR19","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1093\/gerona\/glq186","volume":"66","author":"CM Girelli","year":"2011","unstructured":"Girelli, C. M., Maiero, S., Porta, P. & Cannizzaro, R. Small bowel capsule endoscopy performance in octogenarians: a case-control study. J. Gerontol. Biol. Sci. Med. Sci. 66, 68\u201373 (2011).","journal-title":"J. Gerontol. Biol. Sci. Med. Sci."},{"key":"BFnrgastro201288_CR20","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/s10620-008-0687-y","volume":"55","author":"N Almeida","year":"2010","unstructured":"Almeida, N. et al. The effect of metoclopramide in capsule enteroscopy. Dig. Dis. Sci. 55, 153\u2013157 (2010).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR21","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1016\/j.gie.2009.04.045","volume":"70","author":"SB Hooks","year":"2009","unstructured":"Hooks, S. B., Rutland, T. J. & Di Palma, J. A. Lubiprostone neither decreases gastric and small-bowel transit nor improves visualization of small bowel for capsule endoscopy: a double-blind, placebo-controlled study. Gastrointest. Endosc. 70, 942\u2013946 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR22","doi-asserted-by":"publisher","first-page":"3201","DOI":"10.1007\/s10620-008-0292-0","volume":"53","author":"H Endo","year":"2008","unstructured":"Endo, H. et al. Ingesting 500 ml of polyethylene glycol solution during capsule endoscopy improves the image quality and completion rate to the cecum. Dig. Dis. Sci. 53, 3201\u20133205 (2008).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR23","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1111\/j.1365-2036.2008.03762.x","volume":"28","author":"P Apostolopoulos","year":"2008","unstructured":"Apostolopoulos, P. et al. Clinical trial: effectiveness of chewing-gum in accelerating capsule endoscopy transit time\u2014a prospective randomized, controlled pilot study. Aliment. Pharmacol. Ther. 28, 405\u2013411 (2008).","journal-title":"Aliment. Pharmacol. Ther."},{"key":"BFnrgastro201288_CR24","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.gie.2009.12.003","volume":"72","author":"YJ Gao","year":"2010","unstructured":"Gao, Y. J. et al. Endoscopic capsule placement improves the completion rate of small-bowel capsule endoscopy and increases the diagnostic yield. Gastrointest. Endosc. 72, 103\u2013108 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR25","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1097\/00004836-200609000-00005","volume":"40","author":"AS Cheifetz","year":"2006","unstructured":"Cheifetz, A. S. & Lewis, B. S. Capsule endoscopy retention: is it a complication? J. Clin. Gastroenterol. 40, 688\u2013691 (2006).","journal-title":"J. Clin. Gastroenterol."},{"key":"BFnrgastro201288_CR26","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1016\/j.gie.2007.10.063","volume":"67","author":"JM Herrerias","year":"2008","unstructured":"Herrerias, J. M. et al. Agile patency system eliminates risk of capsule retention in patients with known intestinal strictures who undergo capsule endoscopy. Gastrointest. Endosc. 67, 902\u2013909 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR27","doi-asserted-by":"publisher","first-page":"2732","DOI":"10.1007\/s10620-008-0210-5","volume":"53","author":"AJ Postgate","year":"2008","unstructured":"Postgate, A. J., Burling, D., Gupta, A., Fitzpatrick, A. & Fraser, C. Safety, reliability and limitations of the GIVEN patency capsule in patients at risk of capsule retention: a 3-year technical review. Dig. Dis. Sci. 53, 2732\u20132738 (2008).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR28","first-page":"141","volume":"19","author":"ST Van Turenhout","year":"2010","unstructured":"Van Turenhout, S. T. et al. Diagnostic yield of capsule endoscopy in a tertiary hospital in patients with obscure gastrointestinal bleeding. J. Gastrointest. Liver Dis. 19, 141\u2013145 (2010).","journal-title":"J. Gastrointest. Liver Dis."},{"key":"BFnrgastro201288_CR29","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1055\/s-0029-1214610","volume":"41","author":"D Bandorski","year":"2009","unstructured":"Bandorski, D., Irnich, W., Bruck, M., Kramer, W. & Jakobs, R. Do endoscopy capsules interfere with implantable cardioverter-defibrillators? Endoscopy 41, 457\u2013461 (2009).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR30","first-page":"33","volume":"20","author":"D Bandorski","year":"2011","unstructured":"Bandorski, D. et al. Capsule endoscopy in patients with cardiac pacemakers and implantable cardioverter-defibrillators\u2014a retrospective multicenter investigation. J. Gastrointest. Liver Dis. 20, 33\u201337 (2011).","journal-title":"J. Gastrointest. Liver Dis."},{"key":"BFnrgastro201288_CR31","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1055\/s-2007-966785","volume":"40","author":"MH Dirks","year":"2008","unstructured":"Dirks, M. H., Costea, F. & Seidman, E. G. Successful videocapsule endoscopy in patients with an abdominal cardiac pacemaker. Endoscopy 40, 73\u201375 (2008).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR32","doi-asserted-by":"publisher","first-page":"1067","DOI":"10.1055\/s-2004-826034","volume":"36","author":"M Delvaux","year":"2004","unstructured":"Delvaux, M., Fassler, I. & Gay, G. Clinical usefulness of the endoscopic video capsule as the initial intestinal investigation in patients with obscure digestive bleeding: validation of a diagnostic strategy based on the patient outcome after 12 months. Endoscopy 36, 1067\u20131073 (2004).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR33","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1007\/s10620-011-1592-3","volume":"56","author":"J Vlachogiannakos","year":"2011","unstructured":"Vlachogiannakos, J. et al. Bleeding lesions within reach of conventional endoscopy in capsule endoscopy examinations for obscure gastrointestinal bleeding: is repeating endoscopy economically feasible? Dig. Dis. Sci. 56, 1763\u20131768 (2011).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR34","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.2214\/AJR.08.1494","volume":"193","author":"AK Hara","year":"2009","unstructured":"Hara, A. K., Walker, F. B., Silva, A. C. & Leighton, J. A. Preliminary estimate of triphasic CT enterography performance in hemodynamically stable patients with suspected gastrointestinal bleeding. Am. J. Roentgenol. 193, 1252\u20131260 (2009).","journal-title":"Am. J. Roentgenol."},{"key":"BFnrgastro201288_CR35","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.1016\/j.gie.2011.01.006","volume":"73","author":"A Milano","year":"2011","unstructured":"Milano, A. et al. A prospective evaluation of iron deficiency anemia in the GI endoscopy setting: role of standard endoscopy, videocapsule endoscopy, and CT-enteroclysis. Gastrointest. Endosc. 73, 1002\u20131008 (2011).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR36","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1016\/j.cgh.2008.01.005","volume":"6","author":"SF Pasha","year":"2008","unstructured":"Pasha, S. F. et al. Double-balloon enteroscopy and capsule endoscopy have comparable diagnostic yield in small-bowel disease: a meta-analysis. Clin. Gastroenterol. Hepatol. 6, 671\u2013676 (2008).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR37","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1111\/j.1440-1746.2010.06530.x","volume":"26","author":"CW Teshima","year":"2001","unstructured":"Teshima, C. W., Kuipers, E. J., van Zanten, S. V. & Mensink, P. B. Double balloon enteroscopy and capsule endoscopy for obscure gastrointestinal bleeding: an updated meta-analysis. J. Gastroenterol. Hepatol. 26, 796\u2013801 (2001).","journal-title":"J. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR38","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1111\/j.1572-0241.2007.01058.x","volume":"102","author":"E Saperas","year":"2007","unstructured":"Saperas, E. et al. Capsule endoscopy versus computed tomographic or standard angiography for the diagnosis of obscure gastrointestinal bleeding. Am. J. Gastroenterol. 102, 731\u2013737 (2007).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR39","doi-asserted-by":"publisher","first-page":"1697","DOI":"10.1053\/j.gastro.2007.06.007","volume":"133","author":"GS Raju","year":"2007","unstructured":"Raju, G. S., Gerson, L., Das, A. & Lewis, B. American Gastroenterological Association (AGA) Institute technical review on obscure gastrointestinal bleeding. Gastroenterology 133, 1697\u20131717 (2007).","journal-title":"Gastroenterology"},{"key":"BFnrgastro201288_CR40","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.gie.2010.04.032","volume":"72","author":"GA Decker","year":"2010","unstructured":"Decker, G. A. et al. The role of endoscopy in the management of obscure GI bleeding. Gastrointest. Endosc. 72, 471\u2013479 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR41","doi-asserted-by":"publisher","first-page":"1776","DOI":"10.1007\/s10620-010-1506-9","volume":"56","author":"AT DeBenedet","year":"2011","unstructured":"DeBenedet, A. T., Saini, S. D., Takami, M. & Fisher, L. R. Do clinical characteristics predict the presence of small bowel angioectasias on capsule endoscopy? Dig. Dis. Sci. 56, 1776\u20131781 (2011).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR42","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1016\/j.cgh.2010.07.011","volume":"8","author":"R Sidhu","year":"2010","unstructured":"Sidhu, R., Brunt, L. K., Morley, S. R., Sanders, D. S. & McAlindon, M. E. Undisclosed use of nonsteroidal anti-inflammatory drugs may underlie small-bowel injury observed by capsule endoscopy. Clin. Gastroenterol. Hepatol. 8, 992\u2013995 (2010).","journal-title":"Clin. Gastroenterol. Hepatol."},{"issue":"Suppl. 19","key":"BFnrgastro201288_CR43","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1007\/s00535-008-2248-8","volume":"44","author":"L Maiden","year":"2009","unstructured":"Maiden, L. Capsule endoscopic diagnosis of nonsteroidal anti-inflammatory drug-induced enteropathy. J. Gastroenterol. 44 (Suppl. 19), 64\u201371 (2009).","journal-title":"J. Gastroenterol."},{"key":"BFnrgastro201288_CR44","doi-asserted-by":"publisher","first-page":"643","DOI":"10.1053\/j.gastro.2003.11.057","volume":"126","author":"M Pennazio","year":"2004","unstructured":"Pennazio, M. et al. Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases. Gastroenterology 126, 643\u2013653 (2004).","journal-title":"Gastroenterology"},{"key":"BFnrgastro201288_CR45","first-page":"273","volume":"18","author":"R Sidhu","year":"2009","unstructured":"Sidhu, R., Sanders, D. S., Kapur, K., Leeds, J. S. & McAlindon, M. E. Factors predicting the diagnostic yield and intervention in obscure gastrointestinal bleeding investigators using capsule endoscopy. J. Gastrointest. Liver Dis. 18, 273\u2013278 (2009).","journal-title":"J. Gastrointest. Liver Dis."},{"key":"BFnrgastro201288_CR46","doi-asserted-by":"publisher","first-page":"621","DOI":"10.3109\/00365521.2010.545833","volume":"46","author":"T Matsumura","year":"2011","unstructured":"Matsumura, T. et al. Negative capsule endoscopy for obscure gastrointestinal bleeding is closely associated with the use of low-dose aspirin. Scand. J. Gastroenterol. 46, 621\u2013626 (2011).","journal-title":"Scand. J. Gastroenterol."},{"key":"BFnrgastro201288_CR47","doi-asserted-by":"publisher","first-page":"1224","DOI":"10.1111\/j.1572-0241.2006.00565.x","volume":"101","author":"LH Lai","year":"2006","unstructured":"Lai, L. H. et al. Long-term follow-up of patients with obscure gastrointestinal bleeding after negative capsule endoscopy. Am. J. Gastroenterol. 101, 1224\u20131228 (2006).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR48","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1016\/j.gie.2008.05.053","volume":"69","author":"N Viazis","year":"2009","unstructured":"Viazis, N. et al. Is there a role for second-look capsule endoscopy in patients with obscure GI bleeding after a nondiagnostic first test? Gastrointest. Endosc. 69, 850\u2013856 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR49","unstructured":"Fisher, L. Provocative Capsule Endoscopy. Presented at the 2010 International Conference on Capsule and Double Balloon Endoscopy."},{"key":"BFnrgastro201288_CR50","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1055\/s-0029-1215009","volume":"41","author":"X Li","year":"2009","unstructured":"Li, X., Chen, H., Dai, J., Gao, Y. & Ge, Z. Predictive role of capsule endoscopy on the insertion route of double-balloon endoscopy. Endoscopy 41, 762\u2013766 (2009).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR51","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.amjsurg.2008.06.036","volume":"198","author":"R Douard","year":"2009","unstructured":"Douard, R. et al. Role of intraoperative enteroscopy in the management of obscure gastrointestinal bleeding at the time of video-capsule endoscopy. Am. J. Surg. 198, 6\u201311 (2009).","journal-title":"Am. J. Surg."},{"key":"BFnrgastro201288_CR52","doi-asserted-by":"publisher","first-page":"2441","DOI":"10.1007\/s10620-009-0925-y","volume":"54","author":"S Kim","year":"2009","unstructured":"Kim, S., Kedia, P. S., Jaffe, D. L. & Ahmad, N. A. Impact of capsule endoscopy findings on patient outcomes. Dig. Dis. Sci. 54, 2441\u20132448 (2009).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR53","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1053\/j.gastro.2010.01.047","volume":"138","author":"L Laine","year":"2010","unstructured":"Laine, L., Sahota, A. & Shah, A. Does capsule endoscopy improve outcomes in obscure gastrointestinal bleeding? Randomized trial versus dedicated small bowel radiography. Gastroenterology 138, 1673\u20131680 (2010).","journal-title":"Gastroenterology"},{"key":"BFnrgastro201288_CR54","doi-asserted-by":"publisher","first-page":"3299","DOI":"10.3748\/wjg.v16.i26.3299","volume":"16","author":"C Petruzziello","year":"2010","unstructured":"Petruzziello, C. et al. Wireless capsule endoscopy and proximal small bowel lesions in Crohn's disease. World J. Gastroenterol. 16, 3299\u20133304 (2010).","journal-title":"World J. Gastroenterol."},{"key":"BFnrgastro201288_CR55","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.gie.2009.06.034","volume":"71","author":"S Mehdizadeh","year":"2010","unstructured":"Mehdizadeh, S. et al. Capsule endoscopy in patients with Crohn's disease: diagnostic yield and safety. Gastrointest. Endosc. 71, 121\u2013127 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR56","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1055\/s-2007-995359","volume":"40","author":"S Mehdizadeh","year":"2008","unstructured":"Mehdizadeh, S. et al. Diagnostic yield of capsule endoscopy in ulcerative colitis and inflammatory bowel disease of unclassified type (IBDU). Endoscopy 40, 30\u201335 (2008).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR57","doi-asserted-by":"publisher","first-page":"2734","DOI":"10.1038\/ajg.2009.404","volume":"104","author":"M Tukey","year":"2009","unstructured":"Tukey, M., Pleskow, D., Legnani, P., Cheifetz, A. S. & Moss, A. C. The utility of capsule endoscopy in patients with suspected Crohn's disease. Am. J. Gastroenterol. 104, 2734\u20132739 (2009).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR58","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.gie.2008.02.017","volume":"68","author":"CA Solem","year":"2008","unstructured":"Solem, C. A. et al. Small-bowel imaging in Crohn's disease: a prospective, blinded, 4-way comparison trial. Gastrointest. Endosc. 68, 255\u2013266 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR59","doi-asserted-by":"publisher","first-page":"124","DOI":"10.1016\/j.cgh.2010.10.019","volume":"9","author":"MD Jensen","year":"2011","unstructured":"Jensen, M. D., Nathan, T., Rafaelsen, S. R. & Kjeldsen, J. Diagnostic accuracy of capsule endoscopy for small bowel Crohn's disease is superior to that of MR enterography or CT enterography. Clin. Gastroenterol. Hepatol. 9, 124\u2013129 (2011).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR60","doi-asserted-by":"publisher","first-page":"1240","DOI":"10.1038\/ajg.2009.713","volume":"105","author":"PM Dionisio","year":"2010","unstructured":"Dionisio, P. M. et al. Capsule endoscopy has a significantly higher diagnostic yield in patients with suspected and established small-bowel Crohn's disease: a meta-analysis. Am. J. Gastroenterol. 105, 1240\u20131248 (2010).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR61","doi-asserted-by":"publisher","first-page":"561","DOI":"10.3109\/00365521.2011.551835","volume":"46","author":"A Koulaouzidis","year":"2011","unstructured":"Koulaouzidis, A., Douglas, S., Rogers, M. A., Arnott, I. D. & Plevris, J. N. Fecal calprotectin: a selection tool for small bowel capsule endoscopy in suspected IBD with prior negative bi-directional endoscopy. Scand. J. Gastroenterol. 46, 561\u2013566 (2011).","journal-title":"Scand. J. Gastroenterol."},{"key":"BFnrgastro201288_CR62","first-page":"257","volume":"19","author":"R Sidhu","year":"2010","unstructured":"Sidhu, R. et al. Faecal lactoferrin, capsule endoscopy and Crohn's disease. Is there a three way relationship? A pilot study. J. Gastrointest. Liver Dis. 19, 257\u2013260 (2010).","journal-title":"J. Gastrointest. Liver Dis."},{"key":"BFnrgastro201288_CR63","doi-asserted-by":"publisher","first-page":"1933","DOI":"10.1007\/s10620-007-0084-y","volume":"53","author":"E Gal","year":"2008","unstructured":"Gal, E., Geller, A., Fraser, G., Levi, Z. & Niv, Y. Assessment and validation of the new capsule endoscopy Crohn's disease activity index (CECDAI). Dig. Dis. Sci. 53, 1933\u20131937 (2008).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR64","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1111\/j.1365-2036.2007.03556.x","volume":"27","author":"IM Gralnek","year":"2008","unstructured":"Gralnek, I. M., Defranchis, R., Seidman, E., Leighton, J. A., Legnani, P. & Lewis, B. S. Development of a capsule endoscopy scoring index for small bowel mucosal inflammatory change. Aliment. Pharmacol. Ther. 27, 146\u2013154 (2008).","journal-title":"Aliment. Pharmacol. Ther."},{"key":"BFnrgastro201288_CR65","doi-asserted-by":"publisher","first-page":"987","DOI":"10.1007\/s10620-011-1956-8","volume":"57","author":"A Koulaouzidis","year":"2012","unstructured":"Koulaouzidis, A., Douglas, S. & Plevris, J. N. Lewis score correlates more closely with fecal calprotectin than capsule endoscopy Crohn's disease activity index. Dig. Dis. Sci. 57, 987\u2013993 (2012).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR66","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1007\/s10620-009-0758-8","volume":"55","author":"V Lorenzo-Zuniga","year":"2010","unstructured":"Lorenzo-Zuniga, V. et al. Impact of capsule endoscopy findings in the management of Crohn's disease. Dig. Dis. Sci. 55, 411\u2013414 (2010).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR67","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.cgh.2009.10.032","volume":"8","author":"BG Levesque","year":"2010","unstructured":"Levesque, B. G. et al. Cost effectiveness of alternative imaging strategies for the diagnosis of small-bowel Crohn's disease. Clin. Gastroenterol. Hepatol. 8, 261\u2013267 (2010).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR68","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1097\/MEG.0b013e32830ce7a7","volume":"21","author":"DW Crook","year":"2009","unstructured":"Crook, D. W. et al. Comparison of magnetic resonance enterography and video capsule endoscopy in evaluating small bowel disease. Eur. J. Gastroenterol. Hepatol. 21, 54\u201365 (2009).","journal-title":"Eur. J. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR69","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1055\/s-2007-995783","volume":"40","author":"E Rondonotti","year":"2008","unstructured":"Rondonotti, E. et al. Small-bowel neoplasms in patients undergoing video capsule endoscopy: a multicenter European study. Endoscopy 40, 488\u2013495 (2008).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR70","first-page":"21","volume":"19","author":"A Trifan","year":"2010","unstructured":"Trifan, A., Singeap, A. M., Cojocariu, C., Sfarti, C. & Stanciu, C. Small bowel tumors in patients undergoing capsule endoscopy: a single center experience. J. Gastrointest. Liver Dis. 19, 21\u201325 (2010).","journal-title":"J. Gastrointest. Liver Dis."},{"key":"BFnrgastro201288_CR71","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1016\/j.gie.2010.11.028","volume":"73","author":"E Prakoso","year":"2011","unstructured":"Prakoso, E., Fulham, M., Thompson, J. F. & Selby, W. S. Capsule endoscopy versus positron emission tomography for detection of small-bowel metastatic melanoma: a pilot study. Gastrointest. Endosc. 73, 750\u2013756 (2011).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR72","doi-asserted-by":"publisher","first-page":"6075","DOI":"10.3748\/wjg.15.6075","volume":"15","author":"P Katsinelos","year":"2009","unstructured":"Katsinelos, P. et al. Wireless capsule endoscopy in detecting small-intestinal polyps in familial adenomatous polyposis. World J. Gastroenterol. 15, 6075\u20136079 (2009).","journal-title":"World J. Gastroenterol."},{"key":"BFnrgastro201288_CR73","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1097\/MPG.0b013e31818f0a1f","volume":"49","author":"A Postgate","year":"2009","unstructured":"Postgate, A. et al. Feasibility of video capsule endoscopy in the management of children with Peutz\u2013Jeghers syndrome: a blinded comparison with barium enterography for the detection of small bowel polyps. J. Pediatr. Gastroenterol. Nutr. 49, 417\u2013423 (2009).","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"BFnrgastro201288_CR74","doi-asserted-by":"publisher","first-page":"108","DOI":"10.2214\/AJR.09.3174","volume":"195","author":"A Gupta","year":"2010","unstructured":"Gupta, A. et al. A prospective study of MR enterography versus capsule endoscopy for the surveillance of adult patients with Peutz-Jeghers syndrome. Am. J. Roentgenol. 195, 108\u2013116 (2010).","journal-title":"Am. J. Roentgenol."},{"key":"BFnrgastro201288_CR75","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.gie.2007.11.055","volume":"68","author":"JO Clarke","year":"2008","unstructured":"Clarke, J. O. et al. How good is capsule endoscopy for detection of periampullary lesions? Results of a tertiary-referral center. Gastrointest. Endosc. 68, 267\u2013272 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR76","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1055\/s-2003-41520","volume":"35","author":"E Bardan","year":"2003","unstructured":"Bardan, E., Nadler, M., Chowers, Y., Fidder, H. & Bar-Meir, S. Capsule endoscopy for the evaluation of patients with chronic abdominal pain. Endoscopy 35, 688\u2013689 (2003).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR77","doi-asserted-by":"publisher","first-page":"1264","DOI":"10.1016\/j.arcped.2010.04.026","volume":"17","author":"C Dupont-Lucas","year":"2010","unstructured":"Dupont-Lucas, C. et al. Capsule endoscopy in children: which are the best indications? [French] Arch. Pediatrie 17, 1264\u20131272 (2010).","journal-title":"Arch. Pediatrie"},{"key":"BFnrgastro201288_CR78","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.cgh.2011.03.025","volume":"9","author":"SA Cohen","year":"2011","unstructured":"Cohen, S. A. & Klevens, A. I. Use of capsule endoscopy in diagnosis and management of pediatric patients, based on meta-analysis. Clin. Gastroenterol. Hepatol. 9, 490\u2013496 (2011).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR79","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1016\/j.dld.2010.10.004","volume":"43","author":"G Di Nardo","year":"2011","unstructured":"Di Nardo, G. et al. Usefulness of wireless capsule endoscopy in paediatric inflammatory bowel disease. Dig. Liver Dis. 43, 220\u2013224 (2011).","journal-title":"Dig. Liver Dis."},{"key":"BFnrgastro201288_CR80","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1097\/MPG.0b013e318160df85","volume":"47","author":"SA Cohen","year":"2008","unstructured":"Cohen, S. A. et al. Capsule endoscopy may reclassify pediatric inflammatory bowel disease: a historical analysis. J. Pediatr. Gastroenterol. Nutr. 47, 31\u201336 (2008).","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"BFnrgastro201288_CR81","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1097\/MPG.0b013e3181926b01","volume":"49","author":"O Atay","year":"2009","unstructured":"Atay, O. et al. Risk of capsule endoscope retention in pediatric patients: a large single-center experience and review of the literature. J. Pediatr. Gastroenterol. Nutr. 49, 196\u2013201 (2009).","journal-title":"J. Pediatr. Gastroenterol. Nutr."},{"key":"BFnrgastro201288_CR82","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1136\/gut.2009.177774","volume":"58","author":"A Fritscher-Ravens","year":"2009","unstructured":"Fritscher-Ravens, A. et al. The feasibility of wireless capsule endoscopy in detecting small intestinal pathology in children under the age of 8 years: a multicentre European study. Gut 58, 1467\u20131472 (2009).","journal-title":"Gut"},{"key":"BFnrgastro201288_CR83","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1097\/MEG.0b013e3283433abf","volume":"23","author":"H Dokoutsidou","year":"2011","unstructured":"Dokoutsidou, H. et al. A study comparing an endoscopy nurse and an endoscopy physician in capsule endoscopy interpretation. Eur. J. Gastroenterol. Hepatol. 23, 166\u2013170 (2011).","journal-title":"Eur. J. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR84","doi-asserted-by":"publisher","first-page":"497","DOI":"10.1016\/j.gie.2008.05.070","volume":"69","author":"J Westerhof","year":"2009","unstructured":"Westerhof, J., Koornstra, J. J. & Weersma, R. K. Can we reduce capsule endoscopy reading times? Gastrointest. Endosc. 69, 497\u2013502 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR85","first-page":"522","volume":"13","author":"X Chu","year":"2010","unstructured":"Chu, X. et al. Epitomized summarization of wireless capsule endoscopic videos for efficient visualization. Med. Image Comput. Comput. Assist. Interv. 13, 522\u2013529 (2010).","journal-title":"Med. Image Comput. Comput. Assist. Interv."},{"key":"BFnrgastro201288_CR86","doi-asserted-by":"publisher","first-page":"6929","DOI":"10.3748\/wjg.14.6929","volume":"14","author":"T Gan","year":"2008","unstructured":"Gan, T., Wu, J. C., Rao, N. N., Chen, T. & Liu, B. A feasibility trial of computer-aided diagnosis for enteric lesions in capsule endoscopy. World J. Gastroenterol. 14, 6929\u20136935 (2008).","journal-title":"World J. Gastroenterol."},{"key":"BFnrgastro201288_CR87","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1016\/j.gie.2007.10.060","volume":"67","author":"F Graepler","year":"2008","unstructured":"Graepler, F., Wolter, M., Vonthein, R. & Gregor, M. Accuracy of the size estimation in wireless capsule endoscopy: calibrating the M2A PillCam. Gastrointest. Endosc. 67, 924\u2013931 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR88","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1007\/s10620-010-1336-9","volume":"56","author":"M Rubin","year":"2011","unstructured":"Rubin, M. et al. Live view video capsule endoscopy enables risk stratification of patients with acute upper GI bleeding in the emergency room: a pilot study. Dig. Dis. Sci. 56, 786\u2013791 (2011).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR89","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1016\/j.gie.2008.04.033","volume":"69","author":"S Bang","year":"2009","unstructured":"Bang, S. et al. First clinical trial of the \u201cMiRo\u201d capsule endoscope by using a novel transmission technology: electric field propagation. Gastrointest. Endosc. 69, 253\u2013259 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR90","doi-asserted-by":"publisher","first-page":"2669","DOI":"10.3748\/wjg.v16.i21.2669","volume":"16","author":"Z Liao","year":"2010","unstructured":"Liao, Z. et al. Field of applications, diagnostic yields and findings of OMOM capsule endoscopy in 2400 Chinese patients. World J. Gastroenterol. 16, 2669\u20132676 (2010).","journal-title":"World J. Gastroenterol."},{"key":"BFnrgastro201288_CR91","unstructured":"CapsoVision. CapsoVision [online] , (2012)."},{"key":"BFnrgastro201288_CR92","unstructured":"RF System. RF System Lab [online] , (2012)."},{"key":"BFnrgastro201288_CR93","doi-asserted-by":"publisher","first-page":"1462","DOI":"10.3748\/wjg.v17.i11.1462","volume":"17","author":"K Triantafyllou","year":"2011","unstructured":"Triantafyllou, K., Papanikolaou, I. S., Papaxoinis, K. & Ladas, S. D. Two cameras detect more lesions in the small-bowel than one. World J. Gastroenterol. 17, 1462\u20131467 (2011).","journal-title":"World J. Gastroenterol."},{"key":"BFnrgastro201288_CR94","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1038\/35104644","volume":"414","author":"JM Tarascon","year":"2001","unstructured":"Tarascon, J. M. & Armand, M. Issues and challenges facing rechargeable lithium batteries. Nature 414, 359\u2013367 (2001).","journal-title":"Nature"},{"key":"BFnrgastro201288_CR95","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1002\/rcs.298","volume":"6","author":"W Xin","year":"2010","unstructured":"Xin, W., Yan, G. & Wang, W. Study of a wireless power transmission system for an active capsule endoscope. Int. J. Mod. Robot. 6, 113\u2013122 (2010).","journal-title":"Int. J. Mod. Robot."},{"key":"BFnrgastro201288_CR96","first-page":"3727","volume":"2009","author":"J Wu","year":"2009","unstructured":"Wu, J. & Li, Y. Low-complexity video compression for capsule endoscope based on compressed sensing theory. Conf. Proc. Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. 2009, 3727\u20133730 (2009).","journal-title":"Conf. Proc. Ann. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"BFnrgastro201288_CR97","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1055\/s-0029-1243993","volume":"42","author":"Z Liao","year":"2010","unstructured":"Liao, Z., Xu, C. & Li, Z. S. Completion rate and diagnostic yield of small-bowel capsule endoscopy: 1 vs. 2 frames per second. Endoscopy 42, 360\u2013364 (2010).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR98","first-page":"S667","volume":"138","author":"T Gupta","year":"2010","unstructured":"Gupta, T. et al. Is Fujinon Intelligent Color Enhancement (FICE) assisted capsule endoscopy (CE) useful for analyzing obscure GI bleeding (OGIB)? Gastroenterology 138, S667\u2013S668 (2010).","journal-title":"Gastroenterology"},{"key":"BFnrgastro201288_CR99","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/s10544-005-1588-x","volume":"7","author":"L Wang","year":"2005","unstructured":"Wang, L. et al. Wireless spectroscopic compact photonic explorer for diagnostic optical imaging. Biomed. Microdevices 7, 111\u2013115 (2005).","journal-title":"Biomed. Microdevices"},{"key":"BFnrgastro201288_CR100","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1016\/j.gie.2008.02.023","volume":"68","author":"H Zhang","year":"2008","unstructured":"Zhang, H. et al. Biochromoendoscopy: molecular imaging with capsule endoscopy for detection of adenomas in the GI tract. Gastrointest. Endosc. 68, 520\u2013527 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR101","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.cgh.2007.12.029","volume":"6","author":"JM Buscaglia","year":"2008","unstructured":"Buscaglia, J. M. et al. Performance characteristics of the suspected blood indicator feature in capsule endoscopy according to indication for study. Clin. Gastroenterol. Hepatol. 6, 298\u2013301 (2008).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR102","doi-asserted-by":"publisher","first-page":"575","DOI":"10.1080\/03091900903111974","volume":"33","author":"G Pan","year":"2009","unstructured":"Pan, G., Yan, G., Song, X. & Qiu, X. BP neural network classification for bleeding detection in wireless capsule endoscopy. J. Med. Eng. Tech. 33, 575\u2013581 (2009).","journal-title":"J. Med. Eng. Tech."},{"key":"BFnrgastro201288_CR103","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1109\/TMI.2010.2098882","volume":"30","author":"A Karargyris","year":"2011","unstructured":"Karargyris, A. & Bourbakis, N. Three-dimensional reconstruction of the digestive wall in capsule endoscopy videos using elastic video interpolation. IEEE Trans. Med. Imaging 30, 957\u2013971 (2011).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"BFnrgastro201288_CR104","doi-asserted-by":"publisher","first-page":"1769","DOI":"10.1109\/TMI.2008.926061","volume":"27","author":"M Mackiewicz","year":"2008","unstructured":"Mackiewicz, M., Berens, J. & Fisher, M. Wireless capsule endoscopy color video segmentation. IEEE Trans. Med. Imaging 27, 1769\u20131781 (2008).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"BFnrgastro201288_CR105","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1109\/TBME.2010.2095849","volume":"58","author":"SH Woo","year":"2011","unstructured":"Woo, S. H., Mohy-Ud-Din, Z. & Cho, J. H. Duodenum identification mechanism for capsule endoscopy. IEEE Trans. Biomed. Eng. 58, 905\u2013912 (2011).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"BFnrgastro201288_CR106","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/j.gie.2007.11.055","volume":"68","author":"JO Clarke","year":"2008","unstructured":"Clarke, J. O. et al. How good is capsule endoscopy for detection of periampullary lesions? Results of a tertiary-referral center. Gastrointest. Endosc. 68, 267\u2013272 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR107","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1097\/MEG.0b013e3283410210","volume":"23","author":"WS Selby","year":"2011","unstructured":"Selby, W. S. & Prakoso, E. The inability to visualize the ampulla of Vater is an inherent limitation of capsule endoscopy. Eur. J. Gastroenterol. Hepatol. 23, 101\u2013103 (2011).","journal-title":"Eur. J. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR108","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1097\/MEG.0b013e3283440443","volume":"23","author":"A Koulaouzidis","year":"2011","unstructured":"Koulaouzidis, A., Douglas, S. & Plevris, J. N. Identification of the ampulla of Vater during oesophageal capsule endoscopy: two heads and viewing speed make a difference. Eur. J. Gastroenterol. Hepatol. 23, 361 (2011).","journal-title":"Eur. J. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR109","doi-asserted-by":"publisher","unstructured":"Pox, C. P. et al. Efficacy of a nationwide screening colonoscopy program for colorectal cancer. Gastroenterology http:\/\/dx.doi.org\/10.1053\/j.gastro.2012.03.022 .","DOI":"10.1053\/j.gastro.2012.03.022"},{"key":"BFnrgastro201288_CR110","first-page":"2055","volume":"2008","author":"C Hu","year":"2008","unstructured":"Hu, C., Yang, W., Chen, D., Meng, M. Q. & Dai, H. An improved magnetic localization and orientation algorithm for wireless capsule endoscope. Conf. Proc. Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. 2008, 2055\u20132058 (2008).","journal-title":"Conf. Proc. Ann. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"BFnrgastro201288_CR111","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1586\/erd.09.32","volume":"6","author":"F Carpi","year":"2009","unstructured":"Carpi, F. & Pappone, C. Stereotaxis Niobe magnetic navigation system for endocardial catheter ablation and gastrointestinal capsule endoscopy. Expert Rev. Med. Devices 6, 487\u2013498 (2009).","journal-title":"Expert Rev. Med. Devices"},{"key":"BFnrgastro201288_CR112","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1055\/s-0030-1255521","volume":"42","author":"JF Rey","year":"2010","unstructured":"Rey, J. F. et al. Feasibility of stomach exploration with a guided capsule endoscopy. Endoscopy 42, 541\u2013545 (2010).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR113","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1055\/s-0029-1244170","volume":"42","author":"P Valdastri","year":"2010","unstructured":"Valdastri, P. et al. A magnetic internal mechanism for precise orientation of the camera in wireless endoluminal applications. Endoscopy 42, 481\u2013486 (2010).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR114","doi-asserted-by":"publisher","first-page":"836","DOI":"10.1016\/j.gie.2010.06.016","volume":"72","author":"E Morita","year":"2010","unstructured":"Morita, E. et al. In vivo trial of a driving system for a self-propelling capsule endoscopy using a magnetic field. Gastrointest. Endosc. 72, 836\u2013840 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR115","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1055\/s-0029-1243808","volume":"42","author":"G Ciuti","year":"2010","unstructured":"Ciuti, G. et al. Robotic versus manual control in magnetic steering of an endoscopic capsule. Endoscopy 42, 148\u2013152 (2010).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR116","first-page":"1204","volume":"2009","author":"A Menciassi","year":"2009","unstructured":"Menciassi, A., Valdastri, P., Quaglia, C., Buselli, E. & Dario, P. Wireless steering mechanism with magnetic actuation for an endoscopic capsule. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2009, 1204\u20131207 (2009).","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"BFnrgastro201288_CR117","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.gie.2010.08.053","volume":"73","author":"J Keller","year":"2011","unstructured":"Keller, J. et al. Inspection of the human stomach using remote-controlled capsule endoscopy: a feasibility study in healthy volunteers. Gastrointest. Endosc. 73, 22\u201328 (2011).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR118","first-page":"141","volume":"14","author":"P Mewes","year":"2011","unstructured":"Mewes, P. Automatic region-of interest segmentation and pathology detection in magnetically guided capsule endoscopy. Med. Image Comp. Comp Ass. Intervent. MICCAI 14, 141\u2013148 (2011).","journal-title":"Med. Image Comp. Comp Ass. Intervent. MICCAI"},{"key":"BFnrgastro201288_CR119","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1007\/s10544-006-9025-3","volume":"9","author":"A Moglia","year":"2007","unstructured":"Moglia, A., Menciassi, A., Schurr, M. O. & Dario, P. Wireless capsule endoscopy: from diagnostic devices to multipurpose robotic systems. Biomed. Microdevices 9, 235\u2013243 (2007).","journal-title":"Biomed. Microdevices"},{"key":"BFnrgastro201288_CR120","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1016\/j.gie.2007.11.052","volume":"67","author":"M Quirini","year":"2008","unstructured":"Quirini, M. et al. Feasibility proof of a legged locomotion capsule for the GI tract. Gastrointest. Endosc. 67, 1153\u20131158 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR121","doi-asserted-by":"publisher","first-page":"280","DOI":"10.1080\/13645700903201167","volume":"18","author":"G Tortora","year":"2009","unstructured":"Tortora, G. et al. Propeller-based wireless device for active capsular endoscopy in the gastric district. Minim. Invasive Ther. Allied Technol. 18, 280\u2013290 (2009).","journal-title":"Minim. Invasive Ther. Allied Technol."},{"key":"BFnrgastro201288_CR122","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1016\/j.bios.2009.08.049","volume":"25","author":"R Carta","year":"2009","unstructured":"Carta, R. et al. Wireless powering for a self-propelled and steerable endoscopic capsule for stomach inspection. Biosens. Bioelectron. 25, 845\u2013851 (2009).","journal-title":"Biosens. Bioelectron."},{"key":"BFnrgastro201288_CR123","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/j.gie.2009.12.058","volume":"72","author":"HM Kim","year":"2010","unstructured":"Kim, H. M. et al. Active locomotion of a paddling-based capsule endoscope in an in vitro and in vivo experiment. Gastrointest. Endosc. 72, 381\u2013387 (2010).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR124","first-page":"1946","volume":"2010","author":"JL Toennies","year":"2010","unstructured":"Toennies, J. L. et al. Toward tetherless insufflation of the GI tract. Conf. Proc. Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. 2010, 1946\u20131949 (2010).","journal-title":"Conf. Proc. Ann. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"BFnrgastro201288_CR125","first-page":"1890","volume":"2010","author":"J Chandrappan","year":"2010","unstructured":"Chandrappan, J., Ruigi, L., Su, N., Qiang, T. S. & Vaidyanathan, K. Tagging module for lesion localization in capsule endoscopy. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2010, 1890\u20131893 (2010).","journal-title":"Conf. Proc. IEEE Eng. Med. Biol. Soc."},{"key":"BFnrgastro201288_CR126","unstructured":"Kong, K.-C., Cha, J. & Doyoung, J. A rotational micro biopsy device for the capsule endoscope. International Conference on Intelligent Robots and Systems 3057\u20133061 (2008)."},{"key":"BFnrgastro201288_CR127","doi-asserted-by":"publisher","first-page":"025032","DOI":"10.1088\/0960-1317\/18\/2\/025032","volume":"18","author":"S Park","year":"2008","unstructured":"Park, S. et al. A novel microactuator for microbiopsy in capsular endoscopes. J. Micromech. Microeng. 18, 025032 (2008).","journal-title":"J. Micromech. Microeng."},{"key":"BFnrgastro201288_CR128","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1055\/s-0028-1103424","volume":"40","author":"P Valdastri","year":"2008","unstructured":"Valdastri, P. et al. Wireless therapeutic endoscopic capsule: in vivo experiment. Endoscopy 40, 979\u2013982 (2008).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR129","doi-asserted-by":"publisher","first-page":"1444","DOI":"10.1093\/jnci\/djp396","volume":"101","author":"C Schmidt","year":"2009","unstructured":"Schmidt, C. Capsule endoscopy to screen for colon cancer scores low on sensitivity, high on controversy. J. Natl Cancer Inst. 101, 1444\u20131445 (2009).","journal-title":"J. Natl Cancer Inst."},{"key":"BFnrgastro201288_CR130","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1056\/NEJMoa0806347","volume":"361","author":"A Van Gossum","year":"2009","unstructured":"Van Gossum, A. et al. Capsule endoscopy versus colonoscopy for the detection of polyps and cancer. N. Engl. J. Med. 361, 264\u2013270 (2009).","journal-title":"N. Engl. J. Med."},{"key":"BFnrgastro201288_CR131","doi-asserted-by":"publisher","first-page":"1145","DOI":"10.1111\/j.1365-2036.2010.04458.x","volume":"32","author":"S Sacher-Huvelin","year":"2010","unstructured":"Sacher-Huvelin, S. et al. Colon capsule endoscopy vs. colonoscopy in patients at average or increased risk of colorectal cancer. Aliment. Pharmacol. Ther. 32, 1145\u20131153 (2010).","journal-title":"Aliment. Pharmacol. Ther."},{"key":"BFnrgastro201288_CR132","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1016\/j.cgh.2010.02.018","volume":"8","author":"C Spada","year":"2010","unstructured":"Spada, C. et al. Meta-analysis shows colon capsule endoscopy is effective in detecting colorectal polyps. Clin. Gastroenterol. Hepatol. 8, 516\u2013522 (2010).","journal-title":"Clin. Gastroenterol. Hepatol."},{"key":"BFnrgastro201288_CR133","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1016\/j.gie.2011.03.1125","volume":"74","author":"C Spada","year":"2011","unstructured":"Spada, C. et al. Second-generation colon capsule endoscopy compared with colonoscopy. Gastrointest. Endosc. 74, 581\u2013589 (2011).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR134","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1055\/s-0029-1215360","volume":"41","author":"R Eliakim","year":"2009","unstructured":"Eliakim, R. et al. Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy. Endoscopy 41, 1026\u20131031 (2009).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR135","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1016\/j.gie.2008.10.047","volume":"69","author":"K Triantafyllou","year":"2009","unstructured":"Triantafyllou, K. et al. PillCam COLON capsule endoscopy does not always complement incomplete colonoscopy. Gastrointest. Endosc. 69, 572\u2013576 (2009).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR136","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1586\/erd.10.84","volume":"8","author":"A Sieg","year":"2011","unstructured":"Sieg, A. Colon capsule endoscopy compared with conventional colonoscopy for the detection of colorectal neoplasms. Expert Rev. Med. Devices 8, 257\u2013261 (2011).","journal-title":"Expert Rev. Med. Devices"},{"key":"BFnrgastro201288_CR137","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1055\/s-2007-995645","volume":"40","author":"IM Gralnek","year":"2008","unstructured":"Gralnek, I. M. et al. Detecting esophageal disease with second-generation capsule endoscopy: initial evaluation of the PillCam ESO2. Endoscopy 40, 275\u2013279 (2008).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR138","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1111\/j.1572-0241.2007.01233.x","volume":"103","author":"P Sharma","year":"2008","unstructured":"Sharma, P. et al. The diagnostic accuracy of esophageal capsule endoscopy in patients with gastroesophageal reflux disease and Barrett's esophagus: a blinded, prospective study. Am. J. Gastroenterol. 103, 525\u2013532 (2008).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR139","doi-asserted-by":"publisher","first-page":"1533","DOI":"10.1038\/ajg.2009.86","volume":"104","author":"A Bhardwaj","year":"2009","unstructured":"Bhardwaj, A., Hollenbeck, C. S., Pooran, N. & Mathew, A. A meta-analysis of the diagnostic accuracy of esophageal capsule endoscopy for Barrett's esophagus in patients with gastroesophageal reflux disease. Am. J. Gastroenterol. 104, 1533\u20131539 (2009).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR140","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.gie.2007.10.040","volume":"68","author":"FC Ramirez","year":"2008","unstructured":"Ramirez, F. C., Akins, R. & Shaukat, M. Screening of Barrett's esophagus with string-capsule endoscopy: a prospective blinded study of 100 consecutive patients using histology as the criterion standard. Gastrointest. Endosc. 68, 25\u201331 (2008).","journal-title":"Gastrointest. Endosc."},{"key":"BFnrgastro201288_CR141","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1055\/s-0029-1243856","volume":"42","author":"D Heresbach","year":"2010","unstructured":"Heresbach, D. et al. Diagnostic accuracy of esophageal capsule endoscopy versus conventional upper digestive endoscopy for suspected esophageal squamous cell carcinoma. Endoscopy 42, 93\u201397 (2010).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR142","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1002\/hep.22227","volume":"47","author":"R de Franchis","year":"2008","unstructured":"de Franchis, R. et al. Esophageal capsule endoscopy for screening and surveillance of esophageal varices in patients with portal hypertension. Hepatology 47, 1595\u20131603 (2008).","journal-title":"Hepatology"},{"key":"BFnrgastro201288_CR143","first-page":"1","volume":"57","author":"P Guturu","year":"2011","unstructured":"Guturu, P. et al. Capsule endoscopy and PillCam ESO for detecting esophageal varices: a meta-analysis. Minerva Gastroenterol. Dietol. 57, 1\u201311 (2011).","journal-title":"Minerva Gastroenterol. Dietol."},{"key":"BFnrgastro201288_CR144","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1007\/s10620-010-1272-8","volume":"56","author":"I Schreibman","year":"2011","unstructured":"Schreibman, I. et al. Defining the threshold: new data on the ability of capsule endoscopy to discriminate the size of esophageal varices. Dig. Dis. Sci. 56, 220\u2013226 (2011).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR145","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1038\/ajg.2009.66","volume":"104","author":"MG Lapalus","year":"2009","unstructured":"Lapalus, M. G. et al. Esophageal capsule endoscopy vs. EGD for the evaluation of portal hypertension: a French prospective multicenter comparative study. Am. J. Gastroenterol. 104, 1112\u20131118 (2009).","journal-title":"Am. J. Gastroenterol."},{"key":"BFnrgastro201288_CR146","doi-asserted-by":"publisher","first-page":"980","DOI":"10.1097\/MCG.0b013e3181354455","volume":"42","author":"A Muhammad","year":"2008","unstructured":"Muhammad, A. & Pitchumoni, C. S. Newly detected celiac disease by wireless capsule endoscopy in older adults with iron deficiency anemia. J. Clin. Gastroenterol. 42, 980\u2013983 (2008).","journal-title":"J. Clin. Gastroenterol."},{"key":"BFnrgastro201288_CR147","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1089\/lap.2008.0380","volume":"19","author":"W El-Matary","year":"2009","unstructured":"El-Matary, W., Huynh, H. & Vandermeer, B. Diagnostic characteristics of GIVEN video capsule endoscopy in diagnosis of celiac disease: a meta-analysis. J. Laparoendosc. Adv. Surg. Tech. 19, 815\u2013820 (2009).","journal-title":"J. Laparoendosc. Adv. Surg. Tech."},{"key":"BFnrgastro201288_CR148","doi-asserted-by":"publisher","first-page":"1280","DOI":"10.1007\/s10620-008-0486-5","volume":"54","author":"L Maiden","year":"2009","unstructured":"Maiden, L., Elliott, T., McLaughlin, S. D. & Ciclitira, P. A blinded pilot comparison of capsule endoscopy and small bowel histology in unresponsive celiac disease. Dig. Dis. Sci. 54, 1280\u20131283 (2009).","journal-title":"Dig. Dis. Sci."},{"key":"BFnrgastro201288_CR149","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1056\/NEJM198809223191202","volume":"319","author":"E Brocchi","year":"1988","unstructured":"Brocchi, E. et al. Endoscopic demonstration of loss of duodenal folds in the diagnosis of celiac disease. N. Engl. J. Med. 319, 741\u2013744 (1988).","journal-title":"N. Engl. J. Med."},{"key":"BFnrgastro201288_CR150","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1055\/s-2007-966239","volume":"39","author":"S Daum","year":"2007","unstructured":"Daum, S. et al. Capsule endoscopy in refractory celiac disease. Endoscopy 39, 455\u2013458 (2007).","journal-title":"Endoscopy"},{"key":"BFnrgastro201288_CR151","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1007\/s00535-007-2140-y","volume":"43","author":"H Ogata","year":"2008","unstructured":"Ogata, H. et al. Clinical impact of a newly developed capsule endoscope: usefulness of a real-time viewer for gastric transit abnormality. J. Gastroenterol. 43, 186\u2013192 (2008).","journal-title":"J. Gastroenterol."},{"key":"BFnrgastro201288_CR152","first-page":"453","volume":"58","author":"M Nakamura","year":"2011","unstructured":"Nakamura, M. et al. Are symptomatic changes in irritable bowel syndrome correlated with the capsule endoscopy transit time? A pilot study using the 5-HT4 receptor agonist mosapride. Hepatogastroenterology 58, 453\u2013458 (2011).","journal-title":"Hepatogastroenterology"},{"key":"BFnrgastro201288_CR153","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1111\/j.1365-2982.2010.01612.x","volume":"23","author":"SS Rao","year":"2011","unstructured":"Rao, S. S. et al. Evaluation of gastrointestinal transit in clinical practice: position paper of the American and European Neurogastroenterology and Motility Societies. Neurogastroenterol. Motil. 23, 8\u201323 (2011).","journal-title":"Neurogastroenterol. Motil."},{"key":"BFnrgastro201288_CR154","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1111\/j.1365-2036.2007.03564.x","volume":"27","author":"B Kuo","year":"2008","unstructured":"Kuo, B. et al. Comparison of gastric emptying of a nondigestible capsule to a radio-labelled meal in healthy and gastroparetic subjects. Aliment. Pharmacol. Ther. 27, 186\u2013196 (2008).","journal-title":"Aliment. Pharmacol. Ther."},{"key":"BFnrgastro201288_CR155","doi-asserted-by":"publisher","first-page":"933","DOI":"10.2214\/ajr.143.5.933","volume":"143","author":"CA Rohrmann Jr","year":"1984","unstructured":"Rohrmann, C. A. Jr, Ricci, M. T., Krishnamurthy, S. & Schuffler, M. D. Radiologic and histologic differentiation of neuromuscular disorders of the gastrointestinal tract: visceral myopathies, visceral neuropathies, and progressive systemic sclerosis. AJR Am. J. Roentgenol. 143, 933\u2013941 (1984).","journal-title":"AJR Am. J. Roentgenol."},{"key":"BFnrgastro201288_CR156","doi-asserted-by":"publisher","first-page":"1155","DOI":"10.1053\/j.gastro.2008.06.084","volume":"135","author":"C Malagelada","year":"2008","unstructured":"Malagelada, C. et al. New insight into intestinal motor function via noninvasive endoluminal image analysis. Gastroenterology 135, 1155\u20131162 (2008).","journal-title":"Gastroenterology"},{"key":"BFnrgastro201288_CR157","doi-asserted-by":"publisher","first-page":"1264-e119","DOI":"10.1111\/j.1365-2982.2009.01363.x","volume":"21","author":"F de Iorio","year":"2009","unstructured":"de Iorio, F. et al. Intestinal motor activity, endoluminal motion and transit. Neurogastroenterol. Motil. 21, 1264-e119 (2009).","journal-title":"Neurogastroenterol. Motil."},{"key":"BFnrgastro201288_CR158","unstructured":"VECTOR. Versatile Endoscopic Capsule for gastrointestinal TumOr Recognition and therapy [online] , (2012)."}],"container-title":["Nature Reviews Gastroenterology &amp; Hepatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.nature.com\/articles\/nrgastro.2012.88.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/nrgastro.2012.88","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/nrgastro.2012.88.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,19]],"date-time":"2023-05-19T03:47:18Z","timestamp":1684468038000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/nrgastro.2012.88"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,5,8]]},"references-count":158,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2012,7]]}},"alternative-id":["BFnrgastro201288"],"URL":"https:\/\/doi.org\/10.1038\/nrgastro.2012.88","relation":{},"ISSN":["1759-5045","1759-5053"],"issn-type":[{"value":"1759-5045","type":"print"},{"value":"1759-5053","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,5,8]]}}}