{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T23:30:43Z","timestamp":1793403043094,"version":"4.5.0"},"reference-count":14,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T00:00:00Z","timestamp":1783382400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T00:00:00Z","timestamp":1783382400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J Obes"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Dual-energy X-ray absorptiometry (DXA) is often used as the reference method for calibrating and validating other clinically useful body composition devices, although previous studies report DXA system differences in component estimates. This study evaluated the hypothesis that body composition estimates, specifically percent body fat (BF%), acquired with a method such as 3D optical (3DO) imaging might lead to varying conclusions when judged against different DXA systems and software versions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>BF% was evaluated in healthy adult participants with a 3DO imaging system (Size Stream, Mobile Fit) and three DXA systems (Hologic Horizon A [Apex 4.0.2] and Discovery A [Apex 5.6.1.3]), and GE Lunar iDXA [enCore 13.60.033] on the same day. Agreement between BF% estimates by 3DO and each DXA system was evaluated with multiple statistical procedures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Ninety-nine participants completed all four evaluations. Linear correlations (r and R\n                      <jats:sup>2<\/jats:sup>\n                      s), Bland\u2013Altman analyses, mean differences, mean absolute errors, root-mean square errors, and concordance correlations differed between %BF by 3DO and each of the DXA devices. Relative to BF% by 3DO, agreement measures were best for Discovery A compared to the other two DXA scanners. A linear mixed-effects model with method as a fixed effect and participant as a random intercept revealed a statistically significant effect of assessment method on estimated BF%: Horizon A DXA (X\u2009\u00b1\u2009SD, 36.4\u2009\u00b1\u20099.3%) differed significantly from 3DO (33.3\u2009\u00b1\u20098.8%), iDXA (35.2\u2009\u00b1\u200910.9%), and Discovery A (34.4\u2009\u00b1\u200910.0%); and iDXA and Discovery A both differed significantly from 3DO and Horizon A DXA. Significant interactions between method and sex and method and BMI category were also observed, indicating the differences between measurement methods were not uniform across males and females or BMI categories.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our findings indicate that conclusions related to a clinical body composition method\u2019s accuracy depend on the specific DXA device and associated software version chosen to serve as the reference method.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1038\/s41366-026-02148-6","type":"journal-article","created":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T18:01:47Z","timestamp":1783447307000},"page":"2239-2243","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Reference method matters: DXA system differences influence agreement with 3D optical imaging body composition estimates"],"prefix":"10.1038","volume":"50","author":[{"given":"Sophia","family":"Ramirez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miriam","family":"Bustami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3962-7268","authenticated-orcid":false,"given":"Christian","family":"Rodriguez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8758-7227","authenticated-orcid":false,"given":"Sri Lakshmi S.","family":"Devarakonda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6298-6301","authenticated-orcid":false,"given":"Shengping","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2641-9304","authenticated-orcid":false,"given":"Diana M.","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0230-6586","authenticated-orcid":false,"given":"Grant M.","family":"Tinsley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1127-9425","authenticated-orcid":false,"given":"Steven B.","family":"Heymsfield","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,7]]},"reference":[{"key":"2148_CR1","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.ajcnut.2025.05.022","volume":"122","author":"CM Prado","year":"2025","unstructured":"Prado CM, Gonzalez MC, Norman K, Barazzoni R, Cederholm T, Compher C, et al. Methodological standards for body composition-an expert-endorsed guide for research and clinical applications: levels, models, and terminology. Am J Clin Nutr. 2025;122:384\u201391.","journal-title":"Am J Clin Nutr"},{"key":"2148_CR2","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1093\/ajcn\/61.3.457","volume":"61","author":"ZM Wang","year":"1995","unstructured":"Wang ZM, Heshka S, Pierson RN Jr, Heymsfield SB. Systematic organization of body-composition methodology: an overview with emphasis on component-based methods. Am J Clin Nutr. 1995;61:457\u201365.","journal-title":"Am J Clin Nutr"},{"key":"2148_CR3","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1038\/s41387-022-00223-1","volume":"12","author":"A Buch","year":"2022","unstructured":"Buch A, Ben-Yehuda A, Rouach V, Maier AB, Greenman Y, Izkhakov E, et al. Validation of a multi-frequency bioelectrical impedance analysis device for the assessment of body composition in older adults with type 2 diabetes. Nutr Diab. 2022;12:45.","journal-title":"Nutr Diab"},{"key":"2148_CR4","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1016\/j.nutres.2024.01.002","volume":"123","author":"D Rojano-Ortega","year":"2024","unstructured":"Rojano-Ortega D, Moya-Amaya H, Berral-Aguilar AJ, Baratto P, Molina-Lopez A, Berral-de la Rosa FJ. Development and validation of new bioelectrical impedance equations to accurately estimate fat mass percentage in a heterogeneous Caucasian population. Nutr Res. 2024;123:80\u20137.","journal-title":"Nutr Res"},{"key":"2148_CR5","doi-asserted-by":"publisher","DOI":"10.1016\/j.bone.2020.115683","volume":"142","author":"T Sutter","year":"2021","unstructured":"Sutter T, Duboeuf F, Chapurlat R, Cortet B, Lespessailles E, Roux JP. DXA body composition corrective factors between Hologic Discovery models to conduct multicenter studies. Bone. 2021;142:115683.","journal-title":"Bone"},{"key":"2148_CR6","volume":"8","author":"C Vendrami","year":"2024","unstructured":"Vendrami C, Gatineau G, Gonzalez Rodriguez E, Lamy O, Hans D, Shevroja E. Standardization of body composition parameters between GE Lunar iDXA and Hologic Horizon A and their clinical impact. JBMR. 2024;8:ziae088.","journal-title":"JBMR"},{"key":"2148_CR7","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1016\/j.jocd.2015.06.002","volume":"19","author":"W Xu","year":"2016","unstructured":"Xu W, Chafi H, Guo B, Heymsfield SB, Murray KB, Zheng J, et al. Quantitative comparison of 2 dual-energy X-ray absorptiometry systems in assessing body composition and bone mineral measurements. J Clin Densitom. 2016;19:298\u2013304.","journal-title":"J Clin Densitom"},{"key":"2148_CR8","doi-asserted-by":"publisher","unstructured":"Siekman B, Gagliardi A, Gantz M, Williams K, Tinsley GM, Heymsfield SB, et al. Conversion of DXA body composition measurements across different devices: A standardized approach. Eur J Clin Nutr. 2026. https:\/\/doi.org\/10.1038\/s41430-026-01729-y. Epub ahead of print.","DOI":"10.1038\/s41430-026-01729-y"},{"key":"2148_CR9","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.jocd.2006.01.002","volume":"9","author":"D Krueger","year":"2006","unstructured":"Krueger D, Checovich M, Gemar D, Wei X, Binkley N. Calcium supplement ingestion may alter lumbar spine bone mineral density measurement. J Clin Densitom. 2006;9:159\u201363.","journal-title":"J Clin Densitom"},{"key":"2148_CR10","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1002\/oby.23434","volume":"30","author":"B Smith","year":"2022","unstructured":"Smith B, McCarthy C, Dechenaud ME, Wong MC, Shepherd J, Heymsfield SB. Anthropometric evaluation of a 3D scanning mobile application. Obesity. 2022;30:1181\u20138.","journal-title":"Obesity"},{"key":"2148_CR11","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307\u201310.","journal-title":"Lancet"},{"key":"2148_CR12","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1038\/s41430-023-01289-5","volume":"77","author":"N Ashby","year":"2023","unstructured":"Ashby N, Jake LaPorte G, Richardson D, Scioletti M, Heymsfield SB, Shepherd JA, et al. Translating digital anthropometry measurements obtained from different 3D body image scanners. Eur J Clin Nutr. 2023;77:872\u201380.","journal-title":"Eur J Clin Nutr"},{"key":"2148_CR13","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1634\/theoncologist.2019-0600","volume":"25","author":"GFP Aleixo","year":"2020","unstructured":"Aleixo GFP, Shachar SS, Nyrop KA, Muss HB, Battaglini CL, Williams GR. Bioelectrical impedance analysis for the assessment of sarcopenia in patients with cancer: a systematic review. Oncologist. 2020;25:170\u201382.","journal-title":"Oncologist"},{"key":"2148_CR14","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1146\/annurev-nutr-062122-031443","volume":"44","author":"R Fernandez-Verdejo","year":"2024","unstructured":"Fernandez-Verdejo R, Sanchez-Delgado G, Ravussin E. Energy expenditure in humans: principles, methods, and changes throughout the life course. Annu Rev Nutr. 2024;44:51\u201376.","journal-title":"Annu Rev Nutr"}],"container-title":["International Journal of Obesity"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41366-026-02148-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41366-026-02148-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41366-026-02148-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T23:01:19Z","timestamp":1793401279000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41366-026-02148-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,7]]},"references-count":14,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["2148"],"URL":"https:\/\/doi.org\/10.1038\/s41366-026-02148-6","relation":{},"ISSN":["0307-0565","1476-5497"],"issn-type":[{"value":"0307-0565","type":"print"},{"value":"1476-5497","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,7]]},"assertion":[{"value":"20 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 July 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"SBH serves on the Medical Advisory Boards of Tanita Corporation, Novo Nordisk, Lilly, Abbott, Regeneron, and Medifast. GMT serves as a Scientific Advisor for Prism Labs. Unrelated to the present work, GMT has received research support through in-kind equipment donations and formal research contracts with Size Stream.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}]}}