{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T19:55:28Z","timestamp":1792698928493,"version":"4.5.0"},"reference-count":70,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T00:00:00Z","timestamp":1741910400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Expo Sci Environ Epidemiol"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>There is increasing attention on the effects of residential fossil fuel combustion, particularly the use of natural gas or oil, on indoor air quality. Given the prevalent use of natural gas in Canadian homes, understanding its influence on indoor air quality is important.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>This study investigated associations between indoor levels of nitrogen dioxide (NO<jats:sub>2<\/jats:sub>), carbon monoxide (CO), formaldehyde, and acetaldehyde with potential emission sources and other influencing factors in 344 homes in four Canadian cities.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Using mixed models and general linear models, we evaluated the associations between potential sources and pollutant concentrations, conducting both city-specific and pooled analyses for winter and summer seasons.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Our findings indicated that gas stoves, present in 24% of the homes, were significantly associated with increased indoor NO<jats:sub>2<\/jats:sub> concentrations, resulting in a 191% increase in winter and a 114% increase in summer. Additionally, the presence of gas stoves was strongly associated with a 43% increase in peak hourly CO levels in winter. The presence of gas clothes dryers was significantly associated with increased indoor NO<jats:sub>2<\/jats:sub> levels (47% in summer and 54% in winter). Oil heating was significantly associated with a 58% increase in winter indoor NO<jats:sub>2<\/jats:sub> levels. Gas heating was associated with a 62% increase in winter NO<jats:sub>2<\/jats:sub> levels in older homes (built before 1949), with marginal significance. Aldehyde levels were primarily associated with off-gassing from building materials and household activities. Other factors associated with indoor pollutant levels included housing characteristics, occupant behaviors, indoor environmental conditions, and outdoor sources.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Impact<\/jats:title>\n            <jats:p>\n              <jats:list list-type=\"bullet\">\n                <jats:list-item>\n                  <jats:p>This study enhances understanding of the association between fossil fuel combustion and indoor air quality in predominantly detached homes. It highlights differences in pollutant levels between homes with gas and electric cooking, which can inform advice on cooking practices to reduce emissions in homes.<\/jats:p>\n                <\/jats:list-item>\n              <\/jats:list>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.1038\/s41370-025-00762-6","type":"journal-article","created":{"date-parts":[[2025,3,14]],"date-time":"2025-03-14T11:28:33Z","timestamp":1741951713000},"page":"649-660","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Associations between residential fossil fuel combustion and indoor concentrations of nitrogen dioxide, carbon monoxide, and aldehydes in Canadian homes"],"prefix":"10.1038","volume":"35","author":[{"given":"Liu","family":"Sun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie-\u00c8ve","family":"H\u00e9roux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaohong","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanda J.","family":"Wheeler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,14]]},"reference":[{"key":"762_CR1","unstructured":"Statistics Canada. Households and the Environment: 2011. 2013. Available from: https:\/\/www150.statcan.gc.ca\/n1\/pub\/11-526-s\/11-526-s2013002-eng.htm."},{"key":"762_CR2","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1289\/ehp.1306673","volume":"122","author":"JM Logue","year":"2014","unstructured":"Logue JM, Klepeis NE, Lobscheid AB, Singer BC. Pollutant exposures from natural gas cooking burners: a simulation-based assessment for Southern California. Environ Health Perspect. 2014;122:43\u201350.","journal-title":"Environ Health Perspect"},{"key":"762_CR3","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1111\/ina.12190","volume":"26","author":"NA Mullen","year":"2016","unstructured":"Mullen NA, Li J, Russell ML, Spears M, Less BD, Singer BC. Results of the California Healthy Homes Indoor Air Quality Study of 2011-2013: Impact of natural gas appliances on air pollutant concentrations. Indoor Air. 2016;26:231\u201345.","journal-title":"Indoor Air"},{"key":"762_CR4","unstructured":"Poppendieck D, Gong M. Simmering sauces! Elevated formaldehyde concentrations from gas stove burners. In: 15th Conference of the International Society of Indoor Air Quality and Climate, Indoor Air 2018, Philadelphia, PA. 2018. Available from: https:\/\/tsapps.nist.gov\/publication\/get_pdf.cfm?pub_id=926006."},{"key":"762_CR5","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/j.buildenv.2017.06.021","volume":"122","author":"BC Singer","year":"2017","unstructured":"Singer BC, Pass RZ, Delp WW, Lorenzetti DM, Maddalena RL. Pollutant concentrations and emission rates from natural gas cooking burners without and with range hood exhaust in nine California homes. Build Environ. 2017;122:215\u201329.","journal-title":"Build Environ"},{"key":"762_CR6","unstructured":"Zhu Y, Connolly R, Lin Y, Mathews T, Wang Z. Effects of residential gas appliances on indoor and outdoor air quality and public health in California. UCLA Fielding School of Public Health Department of Environmental Health Sciences. 2020. Available from: https:\/\/ucla.app.box.com\/s\/xyzt8jc1ixnetiv0269qe704wu0ihif7."},{"key":"762_CR7","doi-asserted-by":"crossref","unstructured":"Singer BC, Apte MG, Black DR, Hotchi T, Lucas D, Lunden MM, et al. Natural gas variability in California: environmental impacts and device performance: experimental evaluation of pollutant emissions from residential appliances. Lawrence Berkeley National Laboratory, Berkeley. 2009. Available from: https:\/\/www.osti.gov\/biblio\/980736.","DOI":"10.2172\/980736"},{"key":"762_CR8","doi-asserted-by":"publisher","first-page":"6167","DOI":"10.1021\/es3001079","volume":"46","author":"WW Delp","year":"2012","unstructured":"Delp WW, Singer BC. Performance assessment of U.S. residential cooking exhaust hoods. Environ Sci Technol. 2012;46:6167\u201373.","journal-title":"Environ Sci Technol"},{"key":"762_CR9","doi-asserted-by":"publisher","first-page":"350","DOI":"10.1016\/j.scitotenv.2012.06.015","volume":"432","author":"D Rim","year":"2012","unstructured":"Rim D, Wallace L, Nabinger S, Persily A. Reduction of exposure to ultrafine particles by kitchen exhaust hoods: the effects of exhaust flow rates, particle size, and burner position. Sci Total Environ. 2012;432:350\u20136.","journal-title":"Sci Total Environ"},{"key":"762_CR10","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1111\/j.1600-0668.2011.00756.x","volume":"22","author":"BC Singer","year":"2012","unstructured":"Singer BC, Delp WW, Price PN, Apte MG. Performance of installed cooking exhaust devices. Indoor Air. 2012;22:224\u201334.","journal-title":"Indoor Air"},{"key":"762_CR11","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1016\/j.buildenv.2018.02.039","volume":"135","author":"NA Dobbin","year":"2018","unstructured":"Dobbin NA, Sun L, Wallace L, Kulka R, You H, Shin T, et al. The benefit of kitchen exhaust fan use after cooking - an experimental assessment. Build Environ. 2018;135:286\u201396.","journal-title":"Build Environ"},{"key":"762_CR12","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1038\/s41370-023-00543-z","volume":"33","author":"L Sun","year":"2023","unstructured":"Sun L, Singer BC. Cooking methods and kitchen ventilation availability, usage, perceived performance and potential in Canadian homes. J Expo Sci Environ Epidemiol. 2023;33:439\u201347.","journal-title":"J Expo Sci Environ Epidemiol"},{"key":"762_CR13","doi-asserted-by":"publisher","first-page":"2108","DOI":"10.3390\/ijerph110202108","volume":"11","author":"CJ Matz","year":"2014","unstructured":"Matz CJ, Stieb DM, Davis K, Egyed M, Rose A, Chou B, et al. Effects of age, season, gender and urban-rural status on time-activity: Canadian human activity pattern survey 2 (CHAPS 2). Int J Environ Res Public Health. 2014;11:2108\u201324.","journal-title":"Int J Environ Res Public Health"},{"key":"762_CR14","unstructured":"Fortmann RC, Kariher P, Clayton R. Indoor air quality: residential cooking exposures. Air Resources Board, State of California. 2001. Available from: https:\/\/ww2.arb.ca.gov\/sites\/default\/files\/2023-05\/FR97-330a.pdf."},{"key":"762_CR15","unstructured":"Traynor GW, Apte MG, Chang GM. Pollutant emission factors from residential natural gas appliances: a literature review. Lawrence Berkeley National Laboratory, Berkeley. 1996. Available from: https:\/\/www.osti.gov\/scitech\/servlets\/purl\/1008317."},{"key":"762_CR16","doi-asserted-by":"publisher","first-page":"1233","DOI":"10.1080\/00022470.1986.10466170","volume":"36","author":"SM Relwani","year":"1986","unstructured":"Relwani SM, Moschandreas DJ, Billick IH. Effects of operational factors on pollutant emission rates from residential gas appliances. J Air Pollut Control Assoc. 1986;36:1233\u20137.","journal-title":"J Air Pollut Control Assoc"},{"key":"762_CR17","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/0160-4120(89)90066-4","volume":"15","author":"DJ Moschandreas","year":"1989","unstructured":"Moschandreas DJ, Relwani SM. Field measurements of NO2 gas range-top burner emission rates. Environ Int. 1989;15:489\u201392.","journal-title":"Environ Int"},{"key":"762_CR18","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1046\/j.1600-0668.2003.00216.x","volume":"14","author":"W Yang","year":"2004","unstructured":"Yang W, Lee K, Chung M. Characterization of indoor air quality using multiple measurements of nitrogen dioxide. Indoor Air. 2004;14:105\u201311.","journal-title":"Indoor Air"},{"key":"762_CR19","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1111\/j.1600-0668.2004.00256.x","volume":"14","author":"\u00d3 Garc\u00eda-Algar","year":"2004","unstructured":"Garc\u00eda-Algar \u00d3, Pichini S, Basaga\u00f1a X, Puig C, Vall O, Torrent M, et al. Concentrations and determinants of NO2 in homes of Ashford, UK and Barcelona and Menorca, Spain. Indoor Air. 2004;14:298\u2013304.","journal-title":"Indoor Air"},{"key":"762_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.envres.2006.02.007","volume":"102","author":"NL Gilbert","year":"2006","unstructured":"Gilbert NL, Gauvin D, Guay M, H\u00e9roux M\u00c8, Dupuis G, Legris M, et al. Housing characteristics and indoor concentrations of nitrogen dioxide and formaldehyde in Quebec City, Canada. Environ Res. 2006;102:1\u20138.","journal-title":"Environ Res"},{"key":"762_CR21","doi-asserted-by":"publisher","first-page":"3080","DOI":"10.3390\/ijerph7083080","volume":"7","author":"ME H\u00e9roux","year":"2010","unstructured":"H\u00e9roux ME, Clark N, van, Ryswyk K, Mallick R, Gilbert NL, et al. Predictors of indoor air concentrations in smoking and non-smoking residences. Int J Environ Res Public Health. 2010;7:3080\u201399.","journal-title":"Int J Environ Res Public Health"},{"key":"762_CR22","doi-asserted-by":"publisher","first-page":"324","DOI":"10.3155\/1047-3289.61.3.324","volume":"61","author":"AJ Wheeler","year":"2011","unstructured":"Wheeler AJ, Xu X, Kulka R, You H, Wallace L, Mallach G, et al. Windsor, Ontario exposure assessment study: design and methods validation of personal, indoor, and outdoor air pollution monitoring. J Air Waste Manag Assoc. 2011;61:324\u201338.","journal-title":"J Air Waste Manag Assoc"},{"key":"762_CR23","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1111\/ina.12084","volume":"24","author":"M MacNeill","year":"2014","unstructured":"MacNeill M, Kearney J, Wallace L, Gibson M, H\u00e9roux ME, Kuchta J, et al. Quantifying the contribution of ambient and indoor-generated fine particles to indoor air in residential environments. Indoor Air. 2014;24:362\u201375.","journal-title":"Indoor Air"},{"key":"762_CR24","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/j.atmosenv.2014.05.020","volume":"94","author":"J Kearney","year":"2014","unstructured":"Kearney J, Wallace L, MacNeill M, H\u00e9roux ME, Kindzierski W, Wheeler A. Residential infiltration of fine and ultrafine particles in Edmonton. Atmos Environ. 2014;94:793\u2013805.","journal-title":"Atmos Environ"},{"key":"762_CR25","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1097\/JOM.0b013e3181a0363c","volume":"51","author":"R Dales","year":"2009","unstructured":"Dales R, Wheeler AJ, Mahmud M, Frescura AM, Liu L. The influence of neighborhood roadways on respiratory symptoms among elementary schoolchildren. J Occup Environ Med. 2009;51:654\u201360.","journal-title":"J Occup Environ Med"},{"key":"762_CR26","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/0160-4120(82)90060-5","volume":"8","author":"RN Dietz","year":"1982","unstructured":"Dietz RN, Cote EA. Air infiltration measurements in a home using a convenient perfluorocarbon tracer technique. Environ Int. 1982;8:419\u201333.","journal-title":"Environ Int"},{"key":"762_CR27","doi-asserted-by":"crossref","unstructured":"Helsel DR. Statistics for censored environmental data using Minitab and R - Dennis R. Helsel - Google Books. 2nd ed. New York: John Wiley & Sons, Inc.; 2012. pp. 79\u201393.","DOI":"10.1002\/9781118162729"},{"key":"762_CR28","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/S0048-9697(01)00834-8","volume":"281","author":"B L\u00e9vesque","year":"2001","unstructured":"L\u00e9vesque B, Allaire S, Gauvin D, Koutrakis P, Gingras S, Rhainds M, et al. Wood-burning appliances and indoor air quality. Sci Total Environ. 2001;281:47\u201362.","journal-title":"Sci Total Environ"},{"key":"762_CR29","doi-asserted-by":"publisher","first-page":"1520","DOI":"10.1080\/15287390903129408","volume":"72","author":"T Sahsuvaroglu","year":"2009","unstructured":"Sahsuvaroglu T, Su JG, Brook J, Burnett R, Loeb M, Jerrett M. Predicting personal nitrogen dioxide exposure in an elderly population: integrating residential indoor and outdoor measurements, fixed-site ambient pollution concentrations, modeled pollutant levels, and time-activity patterns. J Toxicol Environ Health. 2009;72:1520\u201333.","journal-title":"J Toxicol Environ Health"},{"key":"762_CR30","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.envres.2004.09.009","volume":"99","author":"NL Gilbert","year":"2005","unstructured":"Gilbert NL, Guay M, Miller JD, Judek S, Chan CC, Dales RE. Levels and determinants of formaldehyde, acetaldehyde, and acrolein in residential indoor air in Prince Edward Island, Canada. Environ Res. 2005;99:11\u20137.","journal-title":"Environ Res"},{"key":"762_CR31","doi-asserted-by":"publisher","first-page":"e0294040","DOI":"10.1371\/journal.pone.0294040","volume":"18","author":"G Mallach","year":"2023","unstructured":"Mallach G, Sun LS, McKay M, Kovesi T, Lawlor G, Kulka R, et al. Indoor air quality in remote first nations communities in Ontario, Canada. PLoS ONE. 2023;18:e0294040.","journal-title":"PLoS ONE"},{"key":"762_CR32","doi-asserted-by":"crossref","unstructured":"Raw GJ, Coward SKD, Brown VM, Crump DR. Exposure to air pollutants in English homes. J Expo Anal Environ Epidemiol. 2004;14:S85-S94.","DOI":"10.1038\/sj.jea.7500363"},{"key":"762_CR33","unstructured":"Blair H, Kearney N, Pricop C, Scholand M. Exposing the hidden health impacts of cooking with gas. CLASP and European Public Health Alliance. 2023."},{"key":"762_CR34","doi-asserted-by":"publisher","first-page":"2529","DOI":"10.1021\/acs.est.1c04707","volume":"56","author":"ED Lebel","year":"2022","unstructured":"Lebel ED, Finnegan CJ, Ouyang Z, Jackson RB. Methane and NOx emissions from natural gas stoves, cooktops, and ovens in residential homes. Environ Sci Technol. 2022;56:2529\u201339.","journal-title":"Environ Sci Technol"},{"key":"762_CR35","doi-asserted-by":"publisher","first-page":"830","DOI":"10.1080\/10962247.2020.1823525","volume":"71","author":"L Sun","year":"2021","unstructured":"Sun L, Wallace LA. Residential cooking and use of kitchen ventilation: the impact on exposure. J Air Waste Manag Assoc. 2021;71:830\u201343.","journal-title":"J Air Waste Manag Assoc"},{"key":"762_CR36","doi-asserted-by":"crossref","unstructured":"Chan WR, Maddalena RL, Stratton JC, Hotchi T, Singer BC, Walker IS, et al. Healthy Efficient New Gas Homes (HENGH) pilot test results. Lawrence Berkeley National Laboratory, Berkeley. 2016. Available from: https:\/\/eta-publications.lbl.gov\/sites\/default\/files\/1005818.pdf.","DOI":"10.2172\/1342387"},{"key":"762_CR37","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1111\/ina.12118","volume":"25","author":"MM Lunden","year":"2015","unstructured":"Lunden MM, Delp WW, Singer BC. Capture efficiency of cooking-related fine and ultrafine particles by residential exhaust hoods. Indoor Air. 2015;25:45\u201358.","journal-title":"Indoor Air"},{"key":"762_CR38","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.tranpol.2018.12.002","volume":"74","author":"J P\u00e9rez","year":"2019","unstructured":"P\u00e9rez J, de Andr\u00e9s JM, Borge R, de la Paz D, Lumbreras J, Rodr\u00edguez E. Vehicle fleet characterization study in the city of Madrid and its application as a support tool in urban transport and air quality policy development. Transp Policy. 2019;74:114\u201326.","journal-title":"Transp Policy"},{"key":"762_CR39","doi-asserted-by":"publisher","DOI":"10.1016\/j.envint.2020.106329","volume":"149","author":"RM Harrison","year":"2021","unstructured":"Harrison RM, Vu TVan, Jafar H, Shi Z. More mileage in reducing urban air pollution from road traffic. Environ Int. 2021;149:106329.","journal-title":"Environ Int"},{"key":"762_CR40","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1080\/10473289.2003.10466297","volume":"53","author":"\u00d3 Garc\u00eda-Algar","year":"2003","unstructured":"Garc\u00eda-Algar \u00d3, Zapater M, Figueroa C, Vall O, Basaga\u00f1 X, Sunyer J, et al. Sources and concentrations of indoor nitrogen dioxide in Barcelona, Spain. J Air Waste Manag Assoc. 2003;53:1312\u20137.","journal-title":"J Air Waste Manag Assoc"},{"key":"762_CR41","unstructured":"Bohac D, Cheple M. Ventilation and depressurization information for houses undergoing remodeling. Minnesota, MN: Final Report for the Minnesota Department of Commerce State Energy Office. 2002."},{"key":"762_CR42","doi-asserted-by":"crossref","unstructured":"Rapp VH, Less BL, Singer BC, Stratton JC, Wray CP. Assessment of literature related to combustion appliance venting systems. Lawrence Berkeley National Laboratory, Berkeley. 2015. Available from: https:\/\/eta-publications.lbl.gov\/sites\/default\/files\/lbnl-5798e-rev.pdf.","DOI":"10.2172\/1220526"},{"key":"762_CR43","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1080\/10473289.1996.10467519","volume":"46","author":"NL Nagda","year":"1996","unstructured":"Nagda NL, Koontz MD, Billick IH, Leslie NP, Behrens DW. Causes and consequences of backdrafting of vented gas appliances. J Air Waste Manag Assoc. 1996;46:838\u201346.","journal-title":"J Air Waste Manag Assoc"},{"key":"762_CR44","unstructured":"Scanada Sheltair Consortium. Residential combustion venting failure - a systems approach. 1987. Available from: https:\/\/publications.gc.ca\/collections\/collection_2016\/schl-cmhc\/NH17-76-1987-eng.pdf."},{"key":"762_CR45","doi-asserted-by":"publisher","first-page":"563","DOI":"10.1080\/10473289.2004.10470931","volume":"54","author":"LA Graham","year":"2004","unstructured":"Graham LA, Noseworthy L, Fugler D, O\u2019leary K, Karman D, Grande C. Contribution of vehicle emissions from an attached garage to residential indoor air pollution levels. J Air Waste Manag Assoc. 2004;54:563\u201384.","journal-title":"J Air Waste Manag Assoc"},{"key":"762_CR46","doi-asserted-by":"publisher","first-page":"487","DOI":"10.1111\/ina.12321","volume":"27","author":"G Mallach","year":"2017","unstructured":"Mallach G, St-Jean M, MacNeill M, Aubin D, Wallace L, Shin T, et al. Exhaust ventilation in attached garages improves residential indoor air quality. Indoor Air. 2017;27:487\u201399.","journal-title":"Indoor Air"},{"key":"762_CR47","unstructured":"Greiner TH, Schwab CV. Carbon monoxide exposure from a vehicle in a garage. 1998. Proceedings of Thermal Envelopes VII. Available from: https:\/\/web.ornl.gov\/sci\/buildings\/conf-archive\/1998%20B7%20papers\/024_Greiner.pdf."},{"key":"762_CR48","doi-asserted-by":"publisher","first-page":"3445","DOI":"10.1016\/j.atmosenv.2005.01.062","volume":"39","author":"WR Chan","year":"2005","unstructured":"Chan WR, Nazaroff WW, Price PN, Sohn MD, Gadgil AJ. Analyzing a database of residential air leakage in the United States. Atmos Environ. 2005;39:3445\u201355.","journal-title":"Atmos Environ"},{"key":"762_CR49","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1177\/1420326X221121519","volume":"32","author":"M Ismaiel","year":"2023","unstructured":"Ismaiel M, Gouda M, Li Y, Chen Y. Airtightness evaluation of Canadian dwellings and influencing factors based on measured data and predictive models. Indoor Built Environ. 2023;32:553\u201373.","journal-title":"Indoor Built Environ"},{"key":"762_CR50","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1111\/j.1600-0668.2008.00580.x","volume":"19","author":"H Guo","year":"2009","unstructured":"Guo H, Kwok NH, Cheng HR, Lee SC, Hung WT, Li YS. Formaldehyde and volatile organic compounds in Hong Kong homes: concentrations and impact factors. Indoor Air. 2009;19:206\u201317.","journal-title":"Indoor Air"},{"key":"762_CR51","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1111\/j.1600-0668.2010.00670.x","volume":"20","author":"Y Maruo","year":"2010","unstructured":"Maruo Y, Yamada T, Nakamura J, Izumi K, Uchiyama M. Formaldehyde measurements in residential indoor air using a developed sensor element in the Kanto area of Japan. Indoor Air. 2010;20:486\u201393.","journal-title":"Indoor Air"},{"key":"762_CR52","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0013-9351(03)00039-2","volume":"92","author":"B Clarisse","year":"2003","unstructured":"Clarisse B, Laurent AM, Seta N, Le Moullec Y, El Hasnaoui A, Momas I. Indoor aldehydes: measurement of contamination levels and identification of their determinants in Paris dwellings. Environ Res. 2003;92:245\u201353.","journal-title":"Environ Res"},{"key":"762_CR53","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1111\/ina.12714","volume":"31","author":"A Klosterk\u00f6ther","year":"2021","unstructured":"Klosterk\u00f6ther A, Kurtenbach R, Wiesen P, Kleffmann J. Determination of the emission indices for NO, NO2, HONO, HCHO, CO, and particles emitted from candles. Indoor Air. 2021;31:116\u201327.","journal-title":"Indoor Air"},{"key":"762_CR54","doi-asserted-by":"publisher","DOI":"10.1016\/j.envint.2021.106590","volume":"155","author":"T Salthammer","year":"2021","unstructured":"Salthammer T, Gu J, Wientzek S, Harrington R, Thomann S. Measurement and evaluation of gaseous and particulate emissions from burning scented and unscented candles. Environ Int. 2021;155:106590.","journal-title":"Environ Int"},{"key":"762_CR55","doi-asserted-by":"publisher","first-page":"2128","DOI":"10.1016\/j.atmosenv.2005.11.047","volume":"40","author":"SC Lee","year":"2006","unstructured":"Lee SC, Wang B. Characteristics of emissions of air pollutants from mosquito coils and candles burning in a large environmental chamber. Atmos Environ. 2006;40:2128\u201338.","journal-title":"Atmos Environ"},{"key":"762_CR56","doi-asserted-by":"publisher","DOI":"10.1016\/j.chemosphere.2020.126324","volume":"250","author":"ZF Zhang","year":"2020","unstructured":"Zhang ZF, Zhang X, Zhang Xming, Liu LY, Li YF, Sun W. Indoor occurrence and health risk of formaldehyde, toluene, xylene and total volatile organic compounds derived from an extensive monitoring campaign in Harbin, a megacity of China. Chemosphere. 2020;250:126324.","journal-title":"Chemosphere"},{"key":"762_CR57","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.buildenv.2014.11.017","volume":"85","author":"H Tao","year":"2015","unstructured":"Tao H, Fan Y, Li X, Zhang Z, Hou W. Investigation of formaldehyde and TVOC in underground malls in Xi\u2019an, China: concentrations, sources, and affecting factors. Build Environ. 2015;85:85\u201393.","journal-title":"Build Environ"},{"key":"762_CR58","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1016\/j.envres.2016.09.003","volume":"151","author":"J Xiong","year":"2016","unstructured":"Xiong J, Zhang P, Huang S, Zhang Y. Comprehensive influence of environmental factors on the emission rate of formaldehyde and VOCs in building materials: correlation development and exposure assessment. Environ Res. 2016;151:734\u201341.","journal-title":"Environ Res"},{"key":"762_CR59","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1016\/0004-6981(75)90188-2","volume":"9","author":"I Andersen","year":"1975","unstructured":"Andersen I, Lundqvist GR, M\u00f8lhave L. Indoor air pollution due to chipboard used as a construction material. Atmos Environ. 1975;9:1121\u20137.","journal-title":"Atmos Environ"},{"key":"762_CR60","doi-asserted-by":"publisher","first-page":"792","DOI":"10.1080\/15298668691390674","volume":"47","author":"T Godish","year":"1986","unstructured":"Godish T, Rough J. Mitigation of residential formaldehyde contamination by indoor climate control. Am Ind Hyg Assoc J. 1986;47:792\u20137.","journal-title":"Am Ind Hyg Assoc J"},{"key":"762_CR61","unstructured":"U.S. EPA. Protect against exposures to formaldehyde. US Environmental Protection Agency. 2023. Available from: https:\/\/www.epa.gov\/formaldehyde\/protect-against-exposures-formaldehyde."},{"key":"762_CR62","unstructured":"Health Canada. Relative humidity indoors: factsheet. 2016. Available from: https:\/\/publications.gc.ca\/collections\/collection_2018\/sc-hc\/H144-33-2016-eng.pdf."},{"key":"762_CR63","unstructured":"Health Canada. Formaldehyde. 2021. Available from: https:\/\/www.canada.ca\/en\/health-canada\/services\/environmental-workplace-health\/reports-publications\/air-quality\/formaldehyde-indoor-air-environment-workplace-health.html#a5."},{"key":"762_CR64","doi-asserted-by":"publisher","first-page":"1785","DOI":"10.1016\/j.buildenv.2011.02.007","volume":"46","author":"J Xu","year":"2011","unstructured":"Xu J, Zhang JS. An experimental study of relative humidity effect on VOCs\u2019 effective diffusion coefficient and partition coefficient in a porous medium. Build Environ. 2011;46:1785\u201396.","journal-title":"Build Environ"},{"key":"762_CR65","doi-asserted-by":"publisher","first-page":"785","DOI":"10.1007\/s11869-018-0593-1","volume":"11","author":"N Nematollahi","year":"2018","unstructured":"Nematollahi N, Doronila A, Mornane PJ, Duan A, Kolev SD, Steinemann A. Volatile chemical emissions from fragranced baby products. Air Qual Atmos Heal. 2018;11:785\u201390.","journal-title":"Air Qual Atmos Heal"},{"key":"762_CR66","first-page":"A16","volume":"119","author":"A Steinemann","year":"2011","unstructured":"Steinemann A. Emit a bouquet of VOCs fragrance figures. Environ Health Perspect. 2011;119:A16.","journal-title":"Environ Health Perspect"},{"key":"762_CR67","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1007\/s11869-016-0442-z","volume":"9","author":"A Steinemann","year":"2016","unstructured":"Steinemann A. Fragranced consumer products: exposures and effects from emissions. Air Qual Atmos Health. 2016;9:861\u20136.","journal-title":"Air Qual Atmos Heal"},{"key":"762_CR68","unstructured":"Statistics Canada. Type of dwelling reference guide. 2021. Available from: https:\/\/www12.statcan.gc.ca\/census-recensement\/2021\/ref\/98-500\/001\/98-500-x2021001-eng.pdf."},{"key":"762_CR69","doi-asserted-by":"publisher","first-page":"996","DOI":"10.1164\/rccm.202302-0278VP","volume":"207","author":"JR Balmes","year":"2023","unstructured":"Balmes JR, Holm SM, McCormack MC, Hansel NN, Gerald LB, Krishnan JA. Cooking with natural gas: just the facts, please. Am J Respir Crit Care Med. 2023;207:996\u20137.","journal-title":"Am J Respir Crit Care Med"},{"key":"762_CR70","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1111\/ina.12085","volume":"24","author":"LM Paulin","year":"2014","unstructured":"Paulin LM, Diette GB, Scott M, McCormack MC, Matsui EC, Curtin-Brosnan J, et al. Home interventions are effective at decreasing indoor nitrogen dioxide concentrations. Indoor Air. 2014;24:416\u201324.","journal-title":"Indoor Air"}],"container-title":["Journal of Exposure Science &amp; Environmental Epidemiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41370-025-00762-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41370-025-00762-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41370-025-00762-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,7]],"date-time":"2025-07-07T09:03:13Z","timestamp":1751878993000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41370-025-00762-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,14]]},"references-count":70,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,7]]}},"alternative-id":["762"],"URL":"https:\/\/doi.org\/10.1038\/s41370-025-00762-6","relation":{},"ISSN":["1559-0631","1559-064X"],"issn-type":[{"value":"1559-0631","type":"print"},{"value":"1559-064X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,14]]},"assertion":[{"value":"26 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 February 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 March 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}