{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,14]],"date-time":"2026-09-14T11:36:34Z","timestamp":1789385794920,"version":"build-2803163510"},"reference-count":7,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T00:00:00Z","timestamp":1705017600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T00:00:00Z","timestamp":1705017600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Perinatol"],"published-print":{"date-parts":[[2024,8]]},"DOI":"10.1038\/s41372-023-01857-4","type":"journal-article","created":{"date-parts":[[2024,1,12]],"date-time":"2024-01-12T18:02:40Z","timestamp":1705082560000},"page":"1193-1195","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Comparison between a laser-lancing device and automatic incision lancet for capillary blood sampling from the heel of newborn infants: a randomized feasibility trial"],"prefix":"10.1038","volume":"44","author":[{"given":"Chul Kyu","family":"Yun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2192-2648","authenticated-orcid":false,"given":"Eui Kyung","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyung Jin","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jaeyoung","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byung Cheol","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyuhee","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0931-2353","authenticated-orcid":false,"given":"Byung Min","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,12]]},"reference":[{"key":"1857_CR1","doi-asserted-by":"publisher","first-page":"F53","DOI":"10.1136\/fn.84.1.F53","volume":"84","author":"H Vertanen","year":"2001","unstructured":"Vertanen H, Fellman V, Brommels M, Viinikka L. An automatic incision device for obtaining blood samples from the heels of preterm infants causes less damage than a conventional manual lancet. Arch Dis Child Fetal Neonatal Ed. 2001;84:F53\u20135.","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"1857_CR2","first-page":"912876","volume":"2013","author":"E Koklu","year":"2013","unstructured":"Koklu E, Ariguloglu EA, Koklu S. Foot skin ischemic necrosis following heel prick in a newborn. Case Rep Pediatr. 2013;2013:912876.","journal-title":"Case Rep Pediatr"},{"issue":"Suppl 1","key":"1857_CR3","first-page":"S89","volume":"8","author":"T Bhalla","year":"2014","unstructured":"Bhalla T, Shepherd E, Tobias JD. Neonatal pain management. Saudi J Anaesth. 2014;8(Suppl 1):S89\u201397.","journal-title":"Saudi J Anaesth"},{"key":"1857_CR4","doi-asserted-by":"publisher","first-page":"936","DOI":"10.4093\/dmj.2021.0293","volume":"46","author":"JA Kim","year":"2022","unstructured":"Kim JA, Park MJ, Song E, Roh E, Park SY, Lee DY, et al. Comparison of laser and conventional lancing devices for blood glucose measurement conformance and patient satisfaction in diabetes mellitus. Diabetes Metab J. 2022;46:936\u201340.","journal-title":"Diabetes Metab J"},{"key":"1857_CR5","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1002\/lsm.23298","volume":"53","author":"WS Yoo","year":"2021","unstructured":"Yoo WS, Min J, Chung PS, Woo SH. Biochemical and pain comparisons between the laser lancing device and needle lancets for capillary blood sampling: a randomized control trial. Lasers Surg Med. 2021;53:316\u201323.","journal-title":"Lasers Surg Med"},{"key":"1857_CR6","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1038\/sj.jp.7210583","volume":"22","author":"M Janes","year":"2002","unstructured":"Janes M, Pinelli J, Landry S, Downey S, Paes B. Comparison of capillary blood sampling using an automated incision device with and without warming the heel. J Perinatol. 2002;22:154\u201385.","journal-title":"J Perinatol"},{"key":"1857_CR7","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1542\/peds.106.1.105","volume":"106","author":"G Yosipovitch","year":"2000","unstructured":"Yosipovitch G, Maayan-Metzger A, Merlob P, Sirota L. Skin barrier properties in different body areas in neonates. Pediatrics. 2000;106:105\u20138.","journal-title":"Pediatrics"}],"container-title":["Journal of Perinatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41372-023-01857-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41372-023-01857-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41372-023-01857-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,5]],"date-time":"2024-08-05T12:06:28Z","timestamp":1722859588000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41372-023-01857-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,12]]},"references-count":7,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2024,8]]}},"alternative-id":["1857"],"URL":"https:\/\/doi.org\/10.1038\/s41372-023-01857-4","relation":{},"ISSN":["0743-8346","1476-5543"],"issn-type":[{"value":"0743-8346","type":"print"},{"value":"1476-5543","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,12]]},"assertion":[{"value":"1 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2023","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2023","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2024","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}