{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T10:24:12Z","timestamp":1787826252380,"version":"build-2784847793"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T00:00:00Z","timestamp":1753401600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T00:00:00Z","timestamp":1753401600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Pediatr Res"],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background and Objectives<\/jats:title>\n                    <jats:p>Failure of continuous positive airway pressure (CPAP) in preterm infants may result from respiratory exhaustion, potentially also evoked by the CPAP device\u2019s imposed work of breathing (iWOB). This study investigated in-vitro the iWOB of 16 CPAP-devices in four simulated neonatal scenarios with focus on the impact of different mechanisms of CPAP-generation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A neonatal lung model and 3D-printed nasopharyngeal dummies (representing a 1000\u2009g preterm and a 3000\u2009g term infant, settings: preterm\/term: V\n                      <jats:sub>tid<\/jats:sub>\n                      4.5\/14\u2009ml, rate 80\/60 bpm) were used to evaluate common CPAP-devices under various conditions (two levels of positive end-expiratory pressure: 5, 10 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      During 9300 simulated breaths, iWOB differed widely across investigated devices. The lowest inspiratory iWOB were observed in Bubble CPAP, variable-flow devices and constant-flow devices with turbine (0.04\/0.15\u20130.17\u2009mJ\/breath for preterm\/term model resp. 0.07\/0.24\u20130.33\u2009mJ\/breath). Devices with mechanical regulation and with constant resistance require higher inspiratory effort and are therefore not relevant in the low iWOB group. The highest iWOB (0.41\/2.92\u2009mJ\/breath at 5 cmH\n                      <jats:sub>2<\/jats:sub>\n                      O) was found in a T-piece device. The mechanism of CPAP generation influenced iWOB levels.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The magnitude of iWOB varied considerably between devices. This should be considered, to optimize non-invasive respiratory support in neonates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Impact<\/jats:title>\n                    <jats:p>\n                      <jats:list list-type=\"bullet\">\n                        <jats:list-item>\n                          <jats:p>This bench study detected differences in the imposed work of breathing (iWOB) between 16 different CPAP devices.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>In addition to existing literature, the present study contributes to a more comprehensive understanding of iWOB and the influence of CPAP generation due to the large number of CPAP devices investigated.<\/jats:p>\n                        <\/jats:list-item>\n                        <jats:list-item>\n                          <jats:p>If the identified differences are confirmed in clinical practice, this could streamline decision-making in CPAP device selection.<\/jats:p>\n                        <\/jats:list-item>\n                      <\/jats:list>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1038\/s41390-025-04265-w","type":"journal-article","created":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T10:34:05Z","timestamp":1753439645000},"page":"1187-1192","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Imposed work of breathing of 16 neonatal CPAP-devices using different mechanisms of CPAP generation"],"prefix":"10.1038","volume":"99","author":[{"given":"Hanna","family":"Sterzik","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joerg","family":"Arand","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0975-1575","authenticated-orcid":false,"given":"Christoph E.","family":"Schwarz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthias","family":"Kumpf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Wald","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Angela","family":"Kribs","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wanda","family":"Lauth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Gross","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian F.","family":"Poets","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bianca","family":"Haase","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,25]]},"reference":[{"key":"4265_CR1","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1001\/jamapediatrics.2021.1497","volume":"175","author":"S Donaldsson","year":"2021","unstructured":"Donaldsson, S. et al. Comparison of Respiratory Support After Delivery in Infants Born Before 28 Weeks\u2019 Gestational Age: The CORSAD Randomized Clinical Trial. JAMA Pediatr. 175, 911\u2013918 (2021).","journal-title":"JAMA Pediatr."},{"key":"4265_CR2","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.1038\/s41390-023-02963-x","volume":"95","author":"CS Chan","year":"2024","unstructured":"Chan, C. S. et al. Evaluation of a respiratory care protocol including less invasive surfactant administration in preterm infants. Pediatr. Res. 95, 1603\u20131610 (2024).","journal-title":"Pediatr. Res"},{"key":"4265_CR3","doi-asserted-by":"crossref","unstructured":"Genzel-Borovicz\u00e9ny O, Nu\u00dfbaum C Checkliste Neonatologie, 7 ed, Stuttgart, Thieme, 2022. p. 245-248.","DOI":"10.1055\/b000000523"},{"key":"4265_CR4","doi-asserted-by":"publisher","first-page":"F203","DOI":"10.1136\/archdischild-2016-310577","volume":"102","author":"S Donaldsson","year":"2017","unstructured":"Donaldsson, S., Drevhammar, T., Taittonen, L., Klemming, S. & Jonsson, B. Initial stabilisation of preterm infants: a new resuscitation system with low imposed work of breathing for use with face mask or nasal prongs. Arch. Dis. Child Fetal Neonatal Ed. 102, F203\u2013F207 (2017).","journal-title":"Arch. Dis. Child Fetal Neonatal Ed."},{"key":"4265_CR5","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2015-3985","volume":"138","author":"PA Dargaville","year":"2016","unstructured":"Dargaville, P. A. et al. Incidence and Outcome of CPAP Failure in Preterm Infants. Pediatrics 138, e20153985 (2016).","journal-title":"Pediatrics"},{"key":"4265_CR6","doi-asserted-by":"publisher","first-page":"1400","DOI":"10.1111\/j.1651-2227.2009.01413.x","volume":"98","author":"H Verder","year":"2009","unstructured":"Verder, H., Bohlin, K., Kamper, J., Lindwall, R. & Jonsson, B. Nasal CPAP and surfactant for treatment of respiratory distress syndrome and prevention of bronchopulmonary dysplasia. Acta Paediatr. 98, 1400\u20131408 (2009).","journal-title":"Acta Paediatr."},{"key":"4265_CR7","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1177\/0310057X8601400304","volume":"14","author":"AW Duncan","year":"1986","unstructured":"Duncan, A. W., Oh, T. E. & Hillman, D. R. PEEP and CPAP. Anaesth. Intensive Care 14, 236\u2013250 (1986).","journal-title":"Anaesth. Intensive Care"},{"key":"4265_CR8","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1002\/(SICI)1099-0496(199609)22:3<188::AID-PPUL8>3.0.CO;2-L","volume":"22","author":"JF Klausner","year":"1996","unstructured":"Klausner, J. F., Lee, A. Y. & Hutchison, A. A. Decreased imposed work with a new nasal continuous positive airway pressure device. Pediatr. Pulmonol. 22, 188\u2013194 (1996).","journal-title":"Pediatr. Pulmonol."},{"key":"4265_CR9","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1542\/peds.108.3.682","volume":"108","author":"PB Pandit","year":"2001","unstructured":"Pandit, P. B., Courtney, S. E., Pyon, K. H., Saslow, J. G. & Habib, R. H. Work of breathing during constant- and variable-flow nasal continuous positive airway pressure in preterm neonates. Pediatrics 108, 682\u2013685 (2001).","journal-title":"Pediatrics"},{"key":"4265_CR10","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.siny.2016.02.009","volume":"21","author":"S Gupta","year":"2016","unstructured":"Gupta, S. & Donn, S. M. Continuous positive airway pressure: Physiology and comparison of devices. Semin Fetal Neonatal Med. 21, 204\u2013211 (2016).","journal-title":"Semin Fetal Neonatal Med"},{"key":"4265_CR11","doi-asserted-by":"publisher","first-page":"453","DOI":"10.1038\/sj.jp.7211325","volume":"25","author":"E Liptsen","year":"2005","unstructured":"Liptsen, E. et al. Work of breathing during nasal continuous positive airway pressure in preterm infants: a comparison of bubble vs variable-flow devices. J. Perinatol. 25, 453\u2013458 (2005).","journal-title":"J. Perinatol."},{"key":"4265_CR12","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1111\/j.1525-1594.2010.01020.x","volume":"35","author":"M Wald","year":"2011","unstructured":"Wald, M. et al. Variety of expiratory resistance between different continuous positive airway pressure devices for preterm infants. Artif. Organs 35, 22\u201328 (2011).","journal-title":"Artif. Organs"},{"key":"4265_CR13","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1542\/peds.112.5.1031","volume":"112","author":"BM Stefanescu","year":"2003","unstructured":"Stefanescu, B. M. et al. A randomized, controlled trial comparing two different continuous positive airway pressure systems for the successful extubation of extremely low birth weight infants. Pediatrics 112, 1031\u20131038 (2003).","journal-title":"Pediatrics"},{"key":"4265_CR14","doi-asserted-by":"publisher","first-page":"322A-A","DOI":"10.1203\/00006450-199904020-01914","volume":"45","author":"SC Sun","year":"1999","unstructured":"Sun, S. C. & Tien, H. C. Randomized Controlled Trial of Two Methods of Nasal CPAP(NCPAP): Flow Driver Vs Conventional NCPAP. Pediatr. Res. 45, 322A-A (1999).","journal-title":"Pediatr. Res."},{"key":"4265_CR15","doi-asserted-by":"publisher","first-page":"318A-A","DOI":"10.1203\/00006450-199904020-01890","volume":"45","author":"H Roukema","year":"1999","unstructured":"Roukema, H., O\u2019Brien, K., Nesbitt, K. & Zaw, W. A Randomized Controlled Trial of Infant Flow Continuous Positive Airway Pressure (CPAP) Versus Nasopharyngeal CPAP in the Extubation of Babies \u2264 1250 grams. Pediatr. Res. 45, 318A-A (1999).","journal-title":"Pediatr. Res."},{"key":"4265_CR16","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1136\/archdischild-2019-317531","volume":"105","author":"B Haase","year":"2020","unstructured":"Haase, B., Badinska, A. M., Koos, B., Poets, C. F. & Lorenz, L. Do commonly available round facemasks fit near-term and term infants?. Arch. Dis. Child Fetal Neonatal Ed. 105, 364\u2013368 (2020).","journal-title":"Arch. Dis. Child Fetal Neonatal Ed."},{"key":"4265_CR17","doi-asserted-by":"publisher","first-page":"654","DOI":"10.1080\/00039896.1969.10666905","volume":"19","author":"SC Glauser","year":"1969","unstructured":"Glauser, S. C., Glauser, E. M. & Rusy, B. F. Influence of gas density and viscosity on the work of breathing. Arch. Environ. Health 19, 654\u2013660 (1969).","journal-title":"Arch. Environ. Health"},{"key":"4265_CR18","doi-asserted-by":"publisher","first-page":"2411","DOI":"10.1002\/ppul.26050","volume":"57","author":"L Auer-Hackenberg","year":"2022","unstructured":"Auer-Hackenberg, L. et al. Breath-dependent pressure fluctuations in various constant- and variable-flow neonatal CPAP devices. Pediatr. Pulmonol. 57, 2411\u20132419 (2022).","journal-title":"Pediatr. Pulmonol."},{"key":"4265_CR19","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1139\/y87-180","volume":"65","author":"JP Mortola","year":"1987","unstructured":"Mortola, J. P., Lauzon, A. M. & Mott, B. Expiratory flow pattern and respiratory mechanics. Can. J. Physiol. Pharm. 65, 1142\u20131145 (1987).","journal-title":"Can. J. Physiol. Pharm."},{"key":"4265_CR20","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1159\/000013962","volume":"73","author":"KS Lee","year":"1998","unstructured":"Lee, K. S., Dunn, M. S., Fenwick, M. & Shennan, A. T. A comparison of underwater bubble continuous positive airway pressure with ventilator-derived continuous positive airway pressure in premature neonates ready for extubation. Biol. Neonate 73, 69\u201375 (1998).","journal-title":"Biol. Neonate"},{"key":"4265_CR21","doi-asserted-by":"publisher","first-page":"e113","DOI":"10.1097\/PCC.0b013e31822f1b79","volume":"13","author":"T Drevhammar","year":"2012","unstructured":"Drevhammar, T., Nilsson, K., Zetterstrom, H. & Jonsson, B. Comparison of seven infant continuous positive airway pressure systems using simulated neonatal breathing. Pediatr. Crit. Care Med. 13, e113\u2013e119 (2012).","journal-title":"Pediatr. Crit. Care Med"},{"key":"4265_CR22","doi-asserted-by":"publisher","first-page":"1929","DOI":"10.1038\/s41390-023-02715-x","volume":"94","author":"K Kuypers","year":"2023","unstructured":"Kuypers, K., Kashyap, A. J., Cramer, S. J. E., Hooper, S. B. & Te Pas, A. B. The effect of imposed resistance in neonatal resuscitators on pressure stability and peak flows: a bench test. Pediatr. Res. 94, 1929\u20131934 (2023).","journal-title":"Pediatr. Res"},{"key":"4265_CR23","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1097\/00003246-198812000-00013","volume":"16","author":"G Moa","year":"1988","unstructured":"Moa, G., Nilsson, K., Zetterstrom, H. & Jonsson, L. O. A new device for administration of nasal continuous positive airway pressure in the newborn: an experimental study. Crit. Care Med. 16, 1238\u20131242 (1988).","journal-title":"Crit. Care Med"},{"key":"4265_CR24","doi-asserted-by":"publisher","first-page":"1760","DOI":"10.1111\/apa.13994","volume":"106","author":"M Falk","year":"2017","unstructured":"Falk, M., Donaldsson, S., Jonsson, B. & Drevhammar, T. Return of neonatal CPAP resistance - the Medijet device family examined using in vitro flow simulations. Acta Paediatr. 106, 1760\u20131766 (2017).","journal-title":"Acta Paediatr."}],"updated-by":[{"DOI":"10.1038\/s41390-025-04640-7","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2025,12,3]],"date-time":"2025-12-03T00:00:00Z","timestamp":1764720000000}}],"container-title":["Pediatric Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41390-025-04265-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41390-025-04265-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41390-025-04265-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T12:21:08Z","timestamp":1774527668000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41390-025-04265-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,25]]},"references-count":24,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026,2]]}},"alternative-id":["4265"],"URL":"https:\/\/doi.org\/10.1038\/s41390-025-04265-w","relation":{},"ISSN":["0031-3998","1530-0447"],"issn-type":[{"value":"0031-3998","type":"print"},{"value":"1530-0447","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,25]]},"assertion":[{"value":"12 March 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 May 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2025","order":6,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":7,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The original online version of this article was revised: In this article the figure for online supplemental with CPAP 10 cmH2O was used instead of the correct Fig. 2.","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 December 2025","order":9,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":10,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":11,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1038\/s41390-025-04640-7","URL":"https:\/\/doi.org\/10.1038\/s41390-025-04640-7","order":12,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"BH participated in the invention of the NeoBreathe device and sold it to PFM Cologne. CES and CFP received funding from Fritz Stephan GmbH and Loewenstein Medical for work unrelated to this study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The trial did not involve humans, the use of the 3D Data published by Haase et al. 2021 was approved by the ethics committee of the university of Tuebingen under the number 242\/2023\u2009A.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent statement"}}]}}