{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T20:27:21Z","timestamp":1784233641634,"version":"3.55.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T00:00:00Z","timestamp":1581033600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T00:00:00Z","timestamp":1581033600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100002855","name":"Ministry of Science and Technology of the People's Republic of China","doi-asserted-by":"publisher","award":["2017YFB1302305"],"award-info":[{"award-number":["2017YFB1302305"]}],"id":[{"id":"10.13039\/501100002855","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Spinal Cord"],"published-print":{"date-parts":[[2020,7]]},"DOI":"10.1038\/s41393-020-0423-9","type":"journal-article","created":{"date-parts":[[2020,2,7]],"date-time":"2020-02-07T12:02:36Z","timestamp":1581076956000},"page":"787-794","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":43,"title":["The safety and feasibility of a new rehabilitation robotic exoskeleton for assisting individuals with lower extremity motor complete lesions following spinal cord injury (SCI): an observational study"],"prefix":"10.1038","volume":"58","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8659-1080","authenticated-orcid":false,"given":"Xiao-Na","family":"Xiang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-Fu","family":"Ding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hui-Yan","family":"Zong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng-Qi","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong-Chen","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,2,7]]},"reference":[{"key":"423_CR1","doi-asserted-by":"publisher","first-page":"2236","DOI":"10.1001\/jama.2015.6250","volume":"313","author":"NB Jain","year":"2015","unstructured":"Jain NB, Ayers GD, Peterson EN, Harris MB, Morse L, O'Connor KC, et al. Traumatic spinal cord injury in the United States, 1993-2012. JAMA. 2015;313:2236\u201343.","journal-title":"JAMA."},{"key":"423_CR2","doi-asserted-by":"publisher","first-page":"S61","DOI":"10.1097\/PHM.0000000000000680","volume":"96","author":"JD Reinhardt","year":"2017","unstructured":"Reinhardt JD, Zheng Y, Xu G, Lu X, Yin Y, Liu S, et al. People with spinal cord injury in China. Am J Phys Med Rehabil. 2017;96:S61\u20135.","journal-title":"Am J Phys Med Rehabil"},{"key":"423_CR3","first-page":"309","volume":"6","author":"A Singh","year":"2014","unstructured":"Singh A, Tetreault L, Kalsi-Ryan S, Nouri A, Fehlings MG. Global prevalence and incidence of traumatic spinal cord injury. Clin Epidemiol. 2014;6:309\u201331.","journal-title":"Clin Epidemiol"},{"key":"423_CR4","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1080\/17483107.2017.1413145","volume":"14","author":"DH Gagnon","year":"2019","unstructured":"Gagnon DH, Vermette M, Duclos C, Aubertin-Leheudre M, Ahmed S, Kairy D. Satisfaction and perceptions of long-term manual wheelchair users with a spinal cord injury upon completion of a locomotor training program with an overground robotic exoskeleton. Disabil Rehabil Assist Technol. 2019;14:138\u201345.","journal-title":"Disabil Rehabil Assist Technol"},{"key":"423_CR5","doi-asserted-by":"publisher","first-page":"436","DOI":"10.1038\/s41393-017-0047-x","volume":"56","author":"EWM Scholten","year":"2018","unstructured":"Scholten EWM, Kieftenbelt A, Hillebregt CF, de Groot S, Ketelaar M, Visser-Meily JMA, et al. Provided support, caregiver burden and well-being in partners of persons with spinal cord injury 5 years after discharge from first inpatient rehabilitation. Spinal Cord. 2018;56:436\u201346.","journal-title":"Spinal Cord"},{"key":"423_CR6","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1310\/sci16-00016","volume":"23","author":"M Arazpour","year":"2017","unstructured":"Arazpour M, Gholami M, Bahramizadeh M, Sharifi G, Bani MA. Influence of reciprocating link when using an Isocentric Reciprocating Gait Orthosis (IRGO) on walking in patients with spinal cord injury: a pilot study. Top Spinal Cord Inj Rehabil. 2017;23:256\u201362.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"423_CR7","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.nec.2016.08.007","volume":"28","author":"G Stricsek","year":"2017","unstructured":"Stricsek G, Ghobrial G, Wilson J, Theofanis T, Harrop JS. Complications in the management of patients with spine trauma. Neurosurg Clin N Am. 2017;28:147\u201355.","journal-title":"Neurosurg Clin N Am"},{"key":"423_CR8","doi-asserted-by":"publisher","first-page":"89","DOI":"10.2147\/MDER.S107134","volume":"10","author":"Y He","year":"2017","unstructured":"He Y, Eguren D, Luu TP, Contreras-Vidal JL. Risk management and regulations for lower limb medical exoskeletons: a review. Med Devices. 2017;10:89\u2013107.","journal-title":"Med Devices"},{"key":"423_CR9","doi-asserted-by":"publisher","first-page":"183","DOI":"10.3109\/17483107.2013.875067","volume":"10","author":"M Ahmadi Bani","year":"2015","unstructured":"Ahmadi Bani M, Arazpour M, Farahmand F, Mousavi ME, Hutchins SW. The efficiency of mechanical orthoses in affecting parameters associated with daily living in spinal cord injury patients: a literature review. Disabil Rehabil Assist Technol. 2015;10:183\u201390.","journal-title":"Disabil Rehabil Assist Technol"},{"key":"423_CR10","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1080\/10790268.2016.1225913","volume":"40","author":"A Ikumi","year":"2016","unstructured":"Ikumi A, Kubota S, Shimizu Y, Kadone H, Marushima A, Ueno T, et al. Decrease of spasticity after hybrid assistive limb\u00ae training for a patient with C4 quadriplegia due to chronic SCI. J Spinal Cord Med. 2016;40:573\u20138.","journal-title":"J Spinal Cord Med"},{"key":"423_CR11","doi-asserted-by":"publisher","first-page":"7492024","DOI":"10.1155\/2018\/7492024","volume":"2018","author":"G Carpino","year":"2018","unstructured":"Carpino G, Pezzola A, Urbano M, Guglielmelli E. Assessing effectiveness and costs in robot-mediated lower limbs rehabilitation: a meta-analysis and state of the art. J Health Eng. 2018;2018:7492024.","journal-title":"J Health Eng"},{"key":"423_CR12","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1080\/10790268.2016.1180831","volume":"39","author":"C Schuld","year":"2016","unstructured":"Schuld C, Franz S, Br\u00fcggemann K, Heutehaus L, Weidner N, Kirshblum SC, et al. International standards for neurological classification of spinal cord injury: impact of the revised worksheet on classification performance. J Spinal Cord Med. 2016;39:504\u201312.","journal-title":"J Spinal Cord Med"},{"key":"423_CR13","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1007\/s00421-012-2421-x","volume":"113","author":"J Scherr","year":"2013","unstructured":"Scherr J, Wolfarth B, Christle JW, Pressler A, Wagenpfeil S, Halle M. Associations between Borg\u2019s rating of perceived exertion and physiological measures of exercise intensity. Eur J Appl Physiol. 2013;113:147\u201355.","journal-title":"Eur J Appl Physiol"},{"key":"423_CR14","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.math.2015.06.002","volume":"21","author":"NM Evensen","year":"2016","unstructured":"Evensen NM, Kv\u00e5le A, Br\u00e6kken IH. Convergent validity of the Timed Up and Go Test and Ten-metre Timed Walk Test in pregnant women with pelvic girdle pain. Man Ther. 2016;21:94\u201399.","journal-title":"Man Ther"},{"key":"423_CR15","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1310\/sci2102-133","volume":"21","author":"ND DiPiro","year":"2015","unstructured":"DiPiro ND, Holthaus KD, Morgan PJ, Embry AE, Perry LA, Bowden MG, et al. Lower extremity strength Is correlated with walking function after incomplete SCI. Top Spinal Cord Inj Rehabil. 2015;21:133\u20139.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"423_CR16","doi-asserted-by":"publisher","first-page":"1926","DOI":"10.1080\/09638280601046302","volume":"29","author":"M Itzkovich","year":"2007","unstructured":"Itzkovich M, Gelernter I, Biering-Sorensen F, Weeks C, Laramee MT, Craven BC, et al. The Spinal Cord Independence Measure (SCIM) version III: reliability and validity in a multi-center international study. Disabil Rehabil. 2007;29:1926\u201333.","journal-title":"Disabil Rehabil"},{"key":"423_CR17","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1038\/sc.2016.142","volume":"55","author":"C Calhoun Thielen","year":"2017","unstructured":"Calhoun Thielen C, Sadowsky C, Vogel LC, Taylor H, Davidson L, Bultman J, et al. Evaluation of the Walking Index for Spinal Cord Injury II (WISCI-II) in children with Spinal Cord Injury (SCI). Spinal Cord. 2017;55:478\u201382.","journal-title":"Spinal Cord"},{"key":"423_CR18","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1111\/jep.12629","volume":"23","author":"RW Bohannon","year":"2017","unstructured":"Bohannon RW, Crouch R. Minimal clinically important difference for change in 6-minute walk test distance of adults with pathology: a systematic review. J Eval Clin Pr. 2017;23:377\u201381.","journal-title":"J Eval Clin Pr"},{"key":"423_CR19","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1038\/sc.2009.107","volume":"48","author":"BC Craven","year":"2009","unstructured":"Craven BC, Morris AR. Modified Ashworth scale reliability for measurement of lower extremity spasticity among patients with SCI. Spinal Cord. 2009;48:207.","journal-title":"Spinal Cord"},{"key":"423_CR20","doi-asserted-by":"publisher","unstructured":"G. Niklas Nor\u00e9n, Roland Orre, Andrew Bate. A hit-miss model for duplicate detection in the WHO drug safety Database. Proceedings of the Eleventh ACM SIGKDD International Conference on Knowledge Discovery in Data Mining. 2005:459\u2013468. https:\/\/doi.org\/10.1145\/1081870.1081923.","DOI":"10.1145\/1081870.1081923"},{"key":"423_CR21","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1310\/sci17-00014","volume":"24","author":"C Tefertiller","year":"2018","unstructured":"Tefertiller C, Hays K, Jones J, Jayaraman A, Hartigan C, Bushnik T, et al. Initial outcomes from a multicenter study utilizing the indego powered exoskeleton in spinal cord injury. Top Spinal Cord Inj Rehabil. 2018;24:78\u201385.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"423_CR22","doi-asserted-by":"crossref","unstructured":"Yue C, Lin X, Zhang X, Qiu J, Cheng H. Design and performance evaluation of a wearable sensing system for lower-limb exoskeleton. Appl Bionics Biomech. 2018;2018:8610458.","DOI":"10.1155\/2018\/8610458"},{"key":"423_CR23","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.apmr.2019.09.005","volume":"101","author":"K McIntosh","year":"2020","unstructured":"McIntosh K, Charbonneau R, Bensaada Y, Bhatiya U, Ho C. The safety and feasibility of exoskeletal-assisted walking in acute rehabilitation after spinal cord injury. Arch Phys Med Rehabil. 2020;101:113\u201320.","journal-title":"Arch Phys Med Rehabil"},{"key":"423_CR24","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1038\/s41393-017-0013-7","volume":"56","author":"C Bach Baunsgaard","year":"2018","unstructured":"Bach Baunsgaard C, Vig Nissen U, Katrin Brust A, Frotzler A, Ribeill C, Kalke YB, et al. Gait training after spinal cord injury: safety, feasibility and gait function following 8 weeks of training with the exoskeletons from Ekso Bionics. Spinal Cord. 2018;56:106\u201316.","journal-title":"Spinal Cord"},{"key":"423_CR25","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1097\/PHM.0b013e318269d9a3","volume":"91","author":"A Esquenazi","year":"2010","unstructured":"Esquenazi A, Talaty M, Packel A, Saulino M. The ReWalk powered exoskeleton to restore ambulatory function to individuals with thoracic-level motor-complete spinal cord injury. Am J Phys Med Rehabil. 2010;91:911\u201321.","journal-title":"Am J Phys Med Rehabil"},{"key":"423_CR26","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1310\/sci2102-93","volume":"21","author":"C Hartigan","year":"2015","unstructured":"Hartigan C, Kandilakis C, Dalley S, Clausen M, Wilson E, Morrison S, et al. Mobility outcomes following five training sessions with a powered exoskeleton. Top Spinal Cord Inj Rehabil. 2015;21:93\u201399.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"423_CR27","doi-asserted-by":"publisher","first-page":"385","DOI":"10.2340\/16501977-2547","volume":"51","author":"A Piira","year":"2019","unstructured":"Piira A, Lannem AM, Sorensen M, Glott T, Knutsen R, J\u00f8rgensen L, et al. Robot-assisted locomotor training did not improve walking function in patients with chronic incomplete spinal cord injury: a randomized clinical trial. J Rehabil Med. 2019;51:385\u201389.","journal-title":"J Rehabil Med"},{"key":"423_CR28","doi-asserted-by":"publisher","DOI":"10.1038\/srep30383","volume":"6","author":"AR Donati","year":"2016","unstructured":"Donati AR, Shokur S, Morya E, Campos DS, Moioli RC, Gitti CM, et al. Long-term training with a brain-machine interface-based gait protocol induces partial neurological recovery in paraplegic patients. Sci Rep. 2016;6:30383.","journal-title":"Sci Rep."},{"key":"423_CR29","doi-asserted-by":"publisher","first-page":"63","DOI":"10.3233\/TAD-180195","volume":"30","author":"V Lajeunesse","year":"2018","unstructured":"Lajeunesse V, Routhier F, Vincent C, Careau E, Michaud F. Perspectives of individuals with incomplete spinal cord injury concerning the usability of lower limb exoskeletons: an exploratory study. Technol Disabil. 2018;30:63\u201376.","journal-title":"Technol Disabil"},{"key":"423_CR30","doi-asserted-by":"crossref","unstructured":"Juszczak M, Gallo E, Bushnik T. Examining the effects of a powered exoskeleton on quality of life and secondary impairments in people living with spinal cord injury. Top Spinal Cord Inj Rehabil. 2018;24:336\u201342.","DOI":"10.1310\/sci17-00055"},{"key":"423_CR31","doi-asserted-by":"publisher","first-page":"3018","DOI":"10.1128\/IAI.00255-13","volume":"81","author":"ZR Balsara","year":"2013","unstructured":"Balsara ZR, Ross SS, Dolber PC, Wiener JS, Tang Y, Seed PC. Enhanced susceptibility to urinary tract infection in the spinal cord-injured host with neurogenic bladder. Infect Immun. 2013;81:3018\u201326.","journal-title":"Infect Immun"},{"key":"423_CR32","first-page":"72","volume":"5","author":"HR Vigil","year":"2016","unstructured":"Vigil HR, Hickling DR. Urinary tract infection in the neurogenic bladder. Transl Androl Urol. 2016;5:72\u201387.","journal-title":"Transl Androl Urol"},{"key":"423_CR33","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1310\/sci2102-100","volume":"21","author":"A Yang","year":"2015","unstructured":"Yang A, Asselin P, Knezevic S, Kornfeld S, Spungen AM. Assessment of in-hospital walking velocity and level of assistance in a powered exoskeleton in persons with spinal cord injury. Top Spinal Cord Inj Rehabil. 2015;21:100\u20139.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"423_CR34","doi-asserted-by":"publisher","DOI":"10.23736\/S1973-9087.18.05308-X","author":"E Guanziroli","year":"2018","unstructured":"Guanziroli E, Cazzaniga M, Colombo L, Basilico S, Legnani G, Molteni F. Assistive powered exoskeleton for complete spinal cord injury: correlations between walking ability and exoskeleton control. Eur J Phys Rehabil Med. 2018. https:\/\/doi.org\/10.23736\/S1973-9087.18.05308-X.","journal-title":"Eur J Phys Rehabil Med"},{"key":"423_CR35","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12984-015-0074-9","volume":"12","author":"DR Louie","year":"2015","unstructured":"Louie DR, Eng JJ, Lam T, Spinal Cord Injury Research Evidence (SCIRE) Research Team. Gait speed using powered robotic exoskeletons after spinal cord injury: a systematic review and correlational study. J Neuroeng Rehabil. 2015;12:82.","journal-title":"J Neuroeng Rehabil"}],"container-title":["Spinal Cord"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.nature.com\/articles\/s41393-020-0423-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/s41393-020-0423-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/s41393-020-0423-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T21:38:57Z","timestamp":1684618737000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41393-020-0423-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,7]]},"references-count":35,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2020,7]]}},"alternative-id":["423"],"URL":"https:\/\/doi.org\/10.1038\/s41393-020-0423-9","relation":{},"ISSN":["1362-4393","1476-5624"],"issn-type":[{"value":"1362-4393","type":"print"},{"value":"1476-5624","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,7]]},"assertion":[{"value":"7 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 January 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 February 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This study received approval from the Ethics Committee of West China Hospital of Sichuan University and was registered at the Chinese Clinical Trial Registry with the following identifier: ChiCTR1900021037. All the necessary approvals were obtained at the three centres.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}