{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T19:41:02Z","timestamp":1772134862494,"version":"3.50.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2022,1,23]],"date-time":"2022-01-23T00:00:00Z","timestamp":1642896000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,1,23]],"date-time":"2022-01-23T00:00:00Z","timestamp":1642896000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100005247","name":"University of British Columbia","doi-asserted-by":"publisher","award":["n\/a"],"award-info":[{"award-number":["n\/a"]}],"id":[{"id":"10.13039\/501100005247","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005247","name":"University of British Columbia","doi-asserted-by":"publisher","award":["n\/a"],"award-info":[{"award-number":["n\/a"]}],"id":[{"id":"10.13039\/501100005247","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Spinal Cord"],"published-print":{"date-parts":[[2022,7]]},"DOI":"10.1038\/s41393-021-00740-3","type":"journal-article","created":{"date-parts":[[2022,1,22]],"date-time":"2022-01-22T19:03:35Z","timestamp":1642878215000},"page":"581-593","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["The microbiological and physical properties of catheters for intermittent catheterization: a systematic review on the impact of reuse and cleaning"],"prefix":"10.1038","volume":"60","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8864-709X","authenticated-orcid":false,"given":"Mark","family":"Grasdal","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5347-1584","authenticated-orcid":false,"given":"Matthias","family":"Walter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrei V.","family":"Krassioukov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,1,23]]},"reference":[{"key":"740_CR1","first-page":"288","volume":"31","author":"A Bakke","year":"1993","unstructured":"Bakke A, Irgens M, Malt F, Hoisreter P. Clean intermittent catheterisation performing abilities, aversive experiences and distress. Paraplegia. 1993;31:288\u201397.","journal-title":"Paraplegia."},{"key":"740_CR2","doi-asserted-by":"publisher","first-page":"2204","DOI":"10.1002\/nau.23562","volume":"37","author":"A Sun","year":"2018","unstructured":"Sun A, Comiter C, Elliott C. The cost of a catheter: An environmental perspective on single use clean intermittent catheterization. Neurourol Urodyn. 2018;37:2204\u20138.","journal-title":"Neurourol Urodyn"},{"key":"740_CR3","first-page":"63","volume":"4","author":"L Guttmann","year":"1966","unstructured":"Guttmann L, Frankel H. The value of intermittent catheterisation in the early management of traumatic paraplegia and tetraplegia. Paraplegia. 1966;4:63\u201384.","journal-title":"Paraplegia."},{"key":"740_CR4","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1016\/S0022-5347(17)61055-3","volume":"107","author":"J Lapides","year":"1972","unstructured":"Lapides J, Diokno A, Silber S, Lowe B. Clean, intermittent self-catheterization in the treatment of urinary tract disease. J Urol. 1972;107:458\u201361.","journal-title":"J Urol."},{"key":"740_CR5","first-page":"122","volume":"77","author":"T Hill","year":"2012","unstructured":"Hill T, Baverstock R, Carlson K, Estey E, Gray G, Hill D, et al. Best practices for the treatment and prevention of urinary tract infection in the spinal cord injured population: The Alberta context Bladder management in the context of a spinal cord injury. Can Urol Assoc J. 2012;77:122\u201330.","journal-title":"Can Urol Assoc J."},{"key":"740_CR6","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.eururo.2015.07.071","volume":"69","author":"J Groen","year":"2016","unstructured":"Groen J, Pannek J, Castro Diaz D, Popolo G, Gross T, Hamid R, et al. Summary of European Association of Urology (EAU) Guidelines on Neuro-Urology. Eur Urol. 2016;69:324\u201333.","journal-title":"Eur Urol"},{"key":"740_CR7","doi-asserted-by":"publisher","first-page":"E910","DOI":"10.1111\/j.1464-410X.2012.11549.x","volume":"110","author":"J-J Wyndaele","year":"2012","unstructured":"Wyndaele J-J, Brauner A, Geerlings S, Bela K, Peter T, Bjerklund-Johanson T. Clean intermittent catheterization and urinary tract infection: Review and guide for future research. BJU Int. 2012;110:E910\u201317.","journal-title":"BJU Int"},{"key":"740_CR8","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1038\/sj.sc.3101646","volume":"42","author":"A Kovindha","year":"2004","unstructured":"Kovindha A, Mai WNC, Madersbacher H. Reused silicone catheter for clean intermittent catheterization (CIC): Is it safe for spinal cord-injured (SCI) men? Spinal Cord. 2004;42:638\u201342.","journal-title":"Spinal Cord."},{"key":"740_CR9","doi-asserted-by":"publisher","first-page":"CD006008","DOI":"10.1002\/14651858.CD006008.pub3","volume":"10","author":"J Prieto","year":"2014","unstructured":"Prieto J, Murphy C, Moore K, Fader M. WITHDRAWN: Intermittent Catheterisation for Long-Term Bladder Management. Cochrane Database Syst Rev. 2014;10:CD006008 https:\/\/doi.org\/10.1002\/14651858.CD006008.pub3. SepUpdate in: Cochrane Database Syst Rev. 2017 Aug 08;8:CD006008. PMID: 25208303.","journal-title":"Cochrane Database Syst Rev."},{"key":"740_CR10","doi-asserted-by":"publisher","first-page":"985","DOI":"10.1089\/neu.2017.5413","volume":"35","author":"K Christison","year":"2018","unstructured":"Christison K, Walter M, Wyndaele J-J, Kennelly M, Kessler T, Noonan V, et al. Intermittent catheterization: The devil is in the details. J Neurotrauma. 2018;35:985\u201389.","journal-title":"J Neurotrauma"},{"key":"740_CR11","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1086\/651091","volume":"31","author":"C Gould","year":"2010","unstructured":"Gould C, Umscheid C, Agarwal R, Kuntz G, Pegues D. Healthcare Infection Control Practices Advisory Committee (HICPAC). Guideline for Prevention of Catheter-Associated Urinary Tract Infections 2009. Infect Control Hospital Epidemiol. 2010;31:319\u201326.","journal-title":"Infect Control Hospital Epidemiol"},{"key":"740_CR12","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1016\/j.euf.2019.10.001","volume":"6","author":"M Walter","year":"2020","unstructured":"Walter M, Krassioukov A. Single-use versus multi-use catheters: pro single-use catheters. Eur Urol Focus. 2020;6:807\u20138.","journal-title":"Eur Urol Focus."},{"key":"740_CR13","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1136\/bmjopen-2018-021554","volume":"8","author":"M Avery","year":"2018","unstructured":"Avery M, Prieto P, Okamoto I, Cullen S, Clancy B, Moore K, et al. Reuse of intermittent catheters: A qualitative study of IC users\u2019 perspectives. BMJ Open. 2018;8:1\u20137. 21554.","journal-title":"BMJ Open."},{"key":"740_CR14","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1007\/s11255-020-02435-9","volume":"52","author":"D Newman","year":"2020","unstructured":"Newman D, New P, Heriseanu R, Petronis S, Hakansson J, Hakansson M, et al. Intermittent catheterization with single- or multiple-reuse catheters: clinical study on safety and impact on quality of life. Int Urol Nephrol. 2020;52:1443\u201351.","journal-title":"Int Urol Nephrol."},{"key":"740_CR15","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1007\/s11884-018-0483-2","volume":"13","author":"D Patel","year":"2018","unstructured":"Patel D, Alabastro C, Anger J. Prevalence and cost of catheters to manage neurogenic bladder. Curr Bladder Dysfunct Rep. 2018;13:215\u201323.","journal-title":"Curr Bladder Dysfunct Rep."},{"key":"740_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2019\/2757862","volume":"2019","author":"M Kennelly","year":"2019","unstructured":"Kennelly M, Thiruchelvam N, Averbeck M, Konstatinidis C, Chartier-Kastler E, Trojgaard P, et al. Adult neurogenic lower urinary tract dysfunction and intermittent catheterisation in a community setting: risk factors model for urinary tract infections. Adv Urol. 2019;2019:1\u201313. 2757862.","journal-title":"Adv Urol"},{"key":"740_CR17","doi-asserted-by":"publisher","first-page":"77","DOI":"10.13004\/kjnt.2019.15.e41","volume":"15","author":"S Jeong","year":"2019","unstructured":"Jeong S, Oh S. Recent updates in urinary catheter products for the neurogenic bladder patients with spinal cord injury. Korean J Neurotrauma. 2019;15:77\u201387.","journal-title":"Korean J Neurotrauma."},{"key":"740_CR18","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1002\/nau.24296","volume":"39","author":"S Wilks","year":"2020","unstructured":"Wilks S, Morris N, Thompson R, Prieto J, Macaulay M, Moore K, et al. An effective evidence-based cleaning method for the safe reuse of intermittent urinary catheters: In vitro testing. Neurourol Urodyn. 2020;39:907\u201315.","journal-title":"Neurourol Urodyn."},{"key":"740_CR19","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1038\/sc.2014.79","volume":"52","author":"M H\u00e5kansson","year":"2014","unstructured":"H\u00e5kansson M. Reuse versus single-use catheters for intermittent catheterization: What is safe and preferred? Review of current status. Spinal Cord. 2014;52:511\u20136.","journal-title":"Spinal Cord."},{"key":"740_CR20","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1016\/S0022-5347(05)64680-0","volume":"168","author":"A Sherbondy","year":"2002","unstructured":"Sherbondy A, Cooper C, Kalinowski S, Boyt M, Hawtrey C. Variability in catheter microwave sterilization techniques in a single clinic population. J Urol. 2002;168:562\u201364.","journal-title":"J Urol"},{"key":"740_CR21","doi-asserted-by":"publisher","first-page":"e1000100","DOI":"10.1371\/journal.pmed.1000100","volume":"6","author":"A Liberati","year":"2009","unstructured":"Liberati A, Altman D, Tetzlaff J, Mulrow C, Gotzche P, Loannidis J, et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration. PLoS Med. 2009;6:e1000100.","journal-title":"PLoS Med."},{"key":"740_CR22","unstructured":"Covidence systematic review software. Veritas Health Innovation: Melbourne, VIC, Australia [Available from: https:\/\/www.covidence.org] (accessed October, 2021)."},{"key":"740_CR23","unstructured":"Joanna Briggs Institute. The Joanna Briggs Institute critical appraisal tools for use in JBI systematic reviews: checklist for quasi-experimental studies (non-randomized experimental studies) 2017 [Available from: https:\/\/jbi.global\/critical-appraisal-tools] (accessed October 2021)."},{"key":"740_CR24","unstructured":"National Heart, Lung, and Blood Institute. Study quality assessment tools: quality assessment tool for observational cohort and cross-sectional studies. [Available from: https:\/\/www.nhlbi.nih.gov\/health-topics\/study-quality-assessment-tools] (accessed October 2021)."},{"key":"740_CR25","unstructured":"National Heart, Lung, and Blood Institute website. Study Quality Assessment Tools: quality assessment tool for case series studies. [Available from: https:\/\/www.nhlbi.nih.gov\/health-topics\/study-quality-assessment-tools] (accessed October 2021)."},{"key":"740_CR26","doi-asserted-by":"publisher","unstructured":"Sterne J, Hern\u00e1n M, Reeves B, Savovic J, Berkman N, Viswanathan M, et al. ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions. BMJ. 2016; https:\/\/doi.org\/10.1136\/bmj.i4919 355:i4919.","DOI":"10.1136\/bmj.i4919"},{"key":"740_CR27","first-page":"10","volume":"12","author":"D Lavall\u00e9e","year":"1995","unstructured":"Lavall\u00e9e D, Lapierre N, Henwood P, Pivik J, Best M, Springthorpe V, et al. Catheter cleaning for re-use in intermittent catheterization: new light on an old problem. SCI Nurs. 1995;12:10\u201312.","journal-title":"SCI Nurs."},{"key":"740_CR28","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1111\/j.1445-2197.1993.tb00519.x","volume":"63","author":"D Griffith","year":"1993","unstructured":"Griffith D, Nacey J, Robinson R, Delahunt B. Microwave Sterilization of Polyethylene Catheters for Intermittent Self\u2010Catheterization. Aust N Z J Surg. 1993;63:203\u20134.","journal-title":"Aust N Z J Surg."},{"key":"740_CR29","doi-asserted-by":"publisher","first-page":"426","DOI":"10.1111\/j.1442-2042.2007.01743.x","volume":"14","author":"Y Sekiguchi","year":"2007","unstructured":"Sekiguchi Y, Yao Y, Ohko Y, Tanaka K, Ishido T, Fujishima A, et al. Self-sterilizing catheters with titanium dioxide photocatalyst thin films for clean intermittent catheterization: Basis and study of clinical use. Int J Urol. 2007;14:426\u201330.","journal-title":"Int J Urol."},{"key":"740_CR30","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1016\/j.eururo.2004.06.016","volume":"46","author":"G Bogaert","year":"2004","unstructured":"Bogaert G, Goeman L, Ridder D, Wevers M, Ivens J, Schuermans A. The physical and antimicrobial effects of microwave heating and alcohol immersion on catheters that are reused for clean intermittent catheterisation. Eur Urol. 2004;46:641\u201346.","journal-title":"Eur Urol"},{"key":"740_CR31","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1002\/j.2048-7940.1997.tb02125.x","volume":"22","author":"J Mervine","year":"1997","unstructured":"Mervine J, Temple R. Using a microwave oven to disinfect intermittent-use catheters. Rehabil Nurs. 1997;22:318\u201320.","journal-title":"Rehabil Nurs."},{"key":"740_CR32","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/0090-4295(90)80035-L","volume":"35","author":"C Douglas","year":"1990","unstructured":"Douglas C, Burke B, Kessler D, Cicmanec J, Bracken B. Method for sterilizing urinary catheters. Urology 1990;35:219\u201322.","journal-title":"Urology"},{"key":"740_CR33","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1002\/j.2048-7940.1995.tb01629.x","volume":"20","author":"M Kurtz","year":"1995","unstructured":"Kurtz M, van Zandt K, Burns J. Comparison study of home catheter cleaning methods. Rehabil Nurs. 1995;20:212\u201314.","journal-title":"Rehabil Nurs."},{"key":"740_CR34","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1016\/j.juro.2009.03.019","volume":"182","author":"J Chan","year":"2009","unstructured":"Chan J, Cooney T, Schober J. Adequacy of sanitization and storage of catheters for intermittent use after washing and microwave sterilization. J Urol. 2009;182:2085\u20139.","journal-title":"J Urol"},{"key":"740_CR35","doi-asserted-by":"publisher","first-page":"601","DOI":"10.3233\/PRM-200741","volume":"13","author":"V Menesesa","year":"2020","unstructured":"Menesesa V, Parentib S, Burns H, Adams R. Latex allergy guidelines for people with spinabifida. J Pediatr Rehabil Med. 2020;13:601\u20139.","journal-title":"J Pediatr Rehabil Med."},{"key":"740_CR36","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1038\/sc.2014.208","volume":"53","author":"A Krassioukov","year":"2015","unstructured":"Krassioukov A, Cragg JJ, West C, Voss C, Krassioukov-Enns D. The good, the bad and the ugly of catheterization practices among elite athletes with spinal cord injury: a global perspective. Spinal Cord. 2015;53:78\u201382.","journal-title":"Spinal Cord."}],"container-title":["Spinal Cord"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41393-021-00740-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41393-021-00740-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41393-021-00740-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,29]],"date-time":"2022-07-29T10:48:49Z","timestamp":1659091729000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41393-021-00740-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,23]]},"references-count":36,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022,7]]}},"alternative-id":["740"],"URL":"https:\/\/doi.org\/10.1038\/s41393-021-00740-3","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/2021.04.28.21256230","asserted-by":"object"}]},"ISSN":["1362-4393","1476-5624"],"issn-type":[{"value":"1362-4393","type":"print"},{"value":"1476-5624","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,23]]},"assertion":[{"value":"5 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 December 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 December 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 January 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Andrei V. Krassioukov is an advisory board member for Coloplast and Wellspect. All other authors declare that they have no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}