{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T11:39:49Z","timestamp":1777894789394,"version":"3.51.4"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,26]],"date-time":"2025-01-26T00:00:00Z","timestamp":1737849600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,26]],"date-time":"2025-01-26T00:00:00Z","timestamp":1737849600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BDJ Open"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The aim of the present study was to compare the accuracy of fully guided implant insertion in vitro achieved by two fabrication methods in a cohort of undergraduates. We hypothesized that both methods achieve a comparable accuracy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Surface scans and cone beam computed tomography images of 48 mandibular models were matched. For each model, two surgical guides enabling a fully guided implant insertion in the region of the first molar on the left or the right side were virtually designed. Fabrication by either Digital Light Processing (DLP) or Fused Filament Fabrication (FFF) followed. Subsequently, 96 implants using the guides were inserted into the models by 48 undergraduate students. The accuracy of the implant insertion was assessed radiographically, followed by statistical analysis. Additionally, all participants completed a questionnaire.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The implants inserted using guides made by DLP showed a higher accuracy compared to guides made by FFF. The mean three-dimensional deviation was 1.94\u2009\u00b1\u20091.05 vs. 3.35\u2009\u00b1\u20092.03 degrees (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). The evaluation of the questionnaires revealed mainly theoretical knowledge and a pronounced interest in implant dentistry.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Discussion<\/jats:title>\n            <jats:p>The main hypothesis has to be rejected as\u00a0there were statistically significant differences in accuracy. However, it is possible to teach students the principles of guided implant dentistry and the digital workflow. Furthermore, the initial and running costs for the FFF workflow are substantially lower enabling a higher practicability for undergraduate education.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Despite the lower accuracy of the templates made from FFF the method seems to be suitable for laboratory hands-on courses for undergraduates.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1038\/s41405-025-00295-y","type":"journal-article","created":{"date-parts":[[2025,1,26]],"date-time":"2025-01-26T12:52:28Z","timestamp":1737895948000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Influence of two different printing methods on the accuracy of full-guided implant insertion \u2013 a laboratory study in undergraduate dental students"],"prefix":"10.1038","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7641-4814","authenticated-orcid":false,"given":"Matthias C.","family":"Schulz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Krimmel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christina","family":"Weismann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pablo","family":"Kaucher-Fernandez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernd","family":"Lethaus","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nils Kristian","family":"Mann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,1,26]]},"reference":[{"key":"295_CR1","doi-asserted-by":"publisher","first-page":"804","DOI":"10.1016\/j.jcms.2017.02.015","volume":"45","author":"R-E Matta","year":"2017","unstructured":"Matta R-E, Bergauer B, Adler W, Wichmann M, Nickenig H-J. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. J Cranio Maxillo Facial Surg. 2017;45:804\u20138.","journal-title":"J Cranio Maxillo Facial Surg"},{"key":"295_CR2","doi-asserted-by":"publisher","first-page":"101","DOI":"10.11607\/jomi.5556","volume":"33","author":"F Bover-Ramos","year":"2018","unstructured":"Bover-Ramos F, Vina-Almunia J, Cervera-Ballester J, Penarrocha-Diago M, Garcia-Mira B. Accuracy of Implant Placement with Computer-Guided Surgery: A Systematic Review and Meta-Analysis Comparing Cadaver, Clinical, and In Vitro Studies. Int J Oral Maxillofac Implants. 2018;33:101\u201315.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"295_CR3","doi-asserted-by":"crossref","unstructured":"Wegm\u00fcller L, Halbeisen F, Sharma N, K\u00fchl S, Thieringer FM. Consumer vs. High-End 3D Printers for Guided Implant Surgery-An In Vitro Accuracy Assessment Study of Different 3D Printing Technologies. J Clin Med. 2021;10:4894.","DOI":"10.3390\/jcm10214894"},{"key":"295_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2023.104748","volume":"139","author":"A Tak\u00e1cs","year":"2023","unstructured":"Tak\u00e1cs A, Hardi E, Cavalcante BGN, Szab\u00f3 B, Kisp\u00e9lyi B, Jo\u00f3b-Fancsaly \u00c1, et al. Advancing accuracy in guided implant placement: A comprehensive meta-analysis: Meta-Analysis evaluation of the accuracy of available implant placement Methods. J Dent. 2023;139:104748.","journal-title":"J Dent"},{"key":"295_CR5","doi-asserted-by":"publisher","DOI":"10.7717\/peerj.14857","volume":"11","author":"Y Huang","year":"2023","unstructured":"Huang Y, Hu Y, Chan U, Lai P, Sun Y, Dai J, et al. Student perceptions toward virtual reality training in dental implant education. PeerJ. 2023;11:e14857.","journal-title":"PeerJ"},{"key":"295_CR6","doi-asserted-by":"publisher","first-page":"30","DOI":"10.2341\/18-229-L","volume":"45","author":"A Kessler","year":"2020","unstructured":"Kessler A, Hickel R, Reymus M. 3D Printing in Dentistry-State of the Art. Operative Dent. 2020;45:30\u201340.","journal-title":"Operative Dent"},{"key":"295_CR7","doi-asserted-by":"publisher","first-page":"743","DOI":"10.11607\/jomi.6074","volume":"33","author":"B Sommacal","year":"2018","unstructured":"Sommacal B, Savic M, Filippi A, K\u00fchl S, Thieringer FM. Evaluation of Two 3D Printers for Guided Implant Surgery. Int J Oral Maxillofac Implants. 2018;33:743\u20136.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"295_CR8","first-page":"e484","volume":"22","author":"M-A S\u00e1nchez-Garc\u00e9s","year":"2017","unstructured":"S\u00e1nchez-Garc\u00e9s M-A, Ber\u00e1stegui-Jimeno E, Gay-Escoda C. Knowledge, aptitudes, and preferences in implant dentistry teaching\/training among undergraduate dental students at the University of Barcelona. Med Oral Patol Oral Cir Bucal. 2017;22:e484\u201390.","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"295_CR9","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/6794682","volume":"2018","author":"A Sharma","year":"2018","unstructured":"Sharma A, Shrestha B, Chaudhari BK, Suwal P, Singh RK, Niraula SR, et al. Preferred Source and Perceived Need of More Information about Dental Implants by the Undergraduate Dental Students of Nepal: All Nepal Survey. Int J Dent. 2018;2018:6794682.","journal-title":"Int J Dent"},{"key":"295_CR10","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-020-00224-8","volume":"6","author":"R Schweyen","year":"2020","unstructured":"Schweyen R, Al-Nawas B, Arnold C, Hey J. A cross-sectional survey of attitudes towards education in implant dentistry in the undergraduate dental curriculum. Int J Implant Dent. 2020;6:26.","journal-title":"Int J Implant Dent"},{"key":"295_CR11","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1002\/jdd.12453","volume":"85","author":"S Chaturvedi","year":"2021","unstructured":"Chaturvedi S, Elmahdi AE, Abdelmonem AM, Haralur SB, Alqahtani NM, Suleman G, et al. Predoctoral dental implant education techniques-students\u2019 perception and attitude. J Dent Educ. 2021;85:392\u2013400.","journal-title":"J Dent Educ"},{"key":"295_CR12","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1111\/j.1532-849X.2007.00247.x","volume":"17","author":"A Maalhagh-Fard","year":"2008","unstructured":"Maalhagh-Fard A, Nimmo A. Eleven-year report on a predoctoral implant dentistry program. J Prosthodontics. 2008;17:64\u20138.","journal-title":"J Prosthodontics"},{"key":"295_CR13","doi-asserted-by":"crossref","unstructured":"Hare A, Bird S, Wright S, Ucer C, Khan RS. Current Undergraduate Dental Implantology Teaching in UK. Dentistry J. 2022;10:127.","DOI":"10.3390\/dj10070127"},{"key":"295_CR14","doi-asserted-by":"crossref","unstructured":"World Medical Association Declaration of Helsinki: ethical principles for medical research involving human subjects. JAMA. 2013;310:2191\u20134.","DOI":"10.1001\/jama.2013.281053"},{"key":"295_CR15","doi-asserted-by":"publisher","DOI":"10.1186\/s40729-019-0176-4","volume":"5","author":"MC Schulz","year":"2019","unstructured":"Schulz MC, Hofmann F, Range U, Lauer G, Haim D. Pilot-drill guided vs. full-guided implant insertion in artificial mandibles-a prospective laboratory study in fifth-year dental students. Int J implant Dent. 2019;5:23.","journal-title":"Int J implant Dent"},{"key":"295_CR16","doi-asserted-by":"crossref","unstructured":"Ebeling M, Sakkas A, Schramm A, Wilde F, Scheurer M, Winter K, et al. Accuracy Analysis of Computer-Assisted and Guided Dental Implantology by Comparing 3D Planning Data and Actual Implant Placement in a Mandibular Training Model: A Monocentric Comparison between Dental Students and Trained Implantologists. J. Personalized Med. 2023;13:1037.","DOI":"10.3390\/jpm13071037"},{"key":"295_CR17","doi-asserted-by":"publisher","first-page":"931","DOI":"10.11607\/jomi.8186","volume":"35","author":"J Abduo","year":"2020","unstructured":"Abduo J, Lau D. Effect of Manufacturing Technique on the Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery. Int J Oral Maxillofac Implants. 2020;35:931\u20138.","journal-title":"Int J Oral Maxillofac Implants"},{"key":"295_CR18","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1111\/jopr.13161","volume":"29","author":"P Henprasert","year":"2020","unstructured":"Henprasert P, Dawson DV, El-Kerdani T, Song X, Couso-Queiruga E, Holloway JA. Comparison of the Accuracy of Implant Position Using Surgical Guides Fabricated by Additive and Subtractive Techniques. J Prosthodontics. 2020;29:534\u201341.","journal-title":"J Prosthodontics"},{"key":"295_CR19","doi-asserted-by":"publisher","first-page":"38","DOI":"10.1111\/jopr.13476","volume":"31","author":"T Elliott","year":"2022","unstructured":"Elliott T, Hamilton A, Griseto N, Gallucci GO. Additively Manufactured Surgical Implant Guides: A Review. J Prosthodontics. 2022;31:38\u201346.","journal-title":"J Prosthodontics"},{"key":"295_CR20","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1016\/j.jcms.2019.03.019","volume":"47","author":"Y Sun","year":"2019","unstructured":"Sun Y, Ding Q, Tang L, Zhang L, Sun Y, Xie Q. Accuracy of a chairside fused deposition modeling 3D-printed single-tooth surgical template for implant placement: An in vitro comparison with a light cured template. J Cranio Maxillo Facial Surg. 2019;47:1216\u201321.","journal-title":"J Cranio Maxillo Facial Surg"},{"key":"295_CR21","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1016\/j.prosdent.2020.03.017","volume":"125","author":"L Herschdorfer","year":"2021","unstructured":"Herschdorfer L, Negreiros WM, Gallucci GO, Hamilton A. Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: An in vitro study. J Prosthet Dent. 2021;125:905\u201310.","journal-title":"J Prosthet Dent"},{"key":"295_CR22","doi-asserted-by":"crossref","unstructured":"Schnutenhaus S, Wagner M, Edelmann C, Luthardt RG, Rudolph H. Factors Influencing the Accuracy of Freehand Implant Placement: A Prospective Clinical Study. Dentistry J. 2021;9:54.","DOI":"10.3390\/dj9050054"},{"key":"295_CR23","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1111\/cid.12705","volume":"21","author":"K El Kholy","year":"2019","unstructured":"El Kholy K, Janner SFM, Schimmel M, Buser D. The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery. Clin implant Dent Relat Res. 2019;21:101\u20137.","journal-title":"Clin implant Dent Relat Res"},{"key":"295_CR24","doi-asserted-by":"publisher","DOI":"10.1155\/2021\/7713058","volume":"2021","author":"AO Al-Zain","year":"2021","unstructured":"Al-Zain AO, Abdel-Azim AM, Othman HI. Dental Students\u2019 Didactic and Psychomotor Skills Performance in Dental Anatomy and Preclinical Operative Dentistry Courses in a Saudi Governmental School. Int J Dent. 2021;2021:7713058.","journal-title":"Int J Dent"},{"key":"295_CR25","doi-asserted-by":"publisher","first-page":"1511","DOI":"10.1002\/jdd.12638","volume":"85","author":"DL Kornmehl","year":"2021","unstructured":"Kornmehl DL, Patel E, Agrawal R, Harris JR, Ba AK, Ohyama H. The effect of gender on student self-assessment skills in operative preclinical dentistry. J Dent Educ. 2021;85:1511\u20137.","journal-title":"J Dent Educ"},{"key":"295_CR26","doi-asserted-by":"crossref","unstructured":"Schulz MC, Rittmann L, Range U, Lauer G, Haim D. The Use of Orientation Templates and Free-Hand Implant Insertion in Artificial Mandibles-An Experimental Laboratory Examination in Fifth-Year Dental Students. Dentistry J. 2018;6:43.","DOI":"10.3390\/dj6030043"},{"key":"295_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.aanat.2023.152082","volume":"248","author":"MC Schulz","year":"2023","unstructured":"Schulz MC, Tokarski M, Jacoby J, Naros A, Weise C, Tausche E, et al. Accuracy of full-guided vs. pilot-guided implant insertion - A prospective laboratory study in fifth-year dental students. Ann Anat. 2023;248:152082.","journal-title":"Ann Anat"},{"key":"295_CR28","doi-asserted-by":"publisher","first-page":"e724","DOI":"10.1111\/eje.12386","volume":"22","author":"SD Haslach","year":"2018","unstructured":"Haslach SD, Aytepe Z, Kokkari A, Azrak B, Ehlers V, Herz MM, et al. Country and gender differences in the motivation of dental students-An international comparison. Eur J Dent Educ. 2018;22:e724\u20139.","journal-title":"Eur J Dent Educ"},{"key":"295_CR29","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1038\/s41415-020-1704-6","volume":"228","author":"S Khan","year":"2020","unstructured":"Khan S, Ibrahim S, Butt R, Ahmed B, White D. The influence of gender on career aspirations of University of Birmingham dental students and junior trainees in the West Midlands. Br Dent J. 2020;228:933\u20137.","journal-title":"Br Dent J"},{"key":"295_CR30","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.jcms.2009.10.023","volume":"38","author":"H-J Nickenig","year":"2010","unstructured":"Nickenig H-J, Wichmann M, Hamel J, Schlegel KA, Eitner S. Evaluation of the difference in accuracy between implant placement by virtual planning data and surgical guide templates versus the conventional free-hand method - a combined in vivo - in vitro technique using cone-beam CT (Part II). J Cranio Maxillo Facial Surg. 2010;38:488\u201393.","journal-title":"J Cranio Maxillo Facial Surg"},{"key":"295_CR31","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1016\/j.jsurg.2013.11.007","volume":"71","author":"DA Back","year":"2014","unstructured":"Back DA, Haberstroh N, Sostmann K, Schmidmaier G, Putzier M, Perka C, et al. High efficacy and students\u2019 satisfaction after voluntary vs mandatory use of an e-learning program in traumatology and orthopedics-a follow-up study. J Surgical Educ. 2014;71:353\u20139.","journal-title":"J Surgical Educ"},{"key":"295_CR32","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1002\/cre2.3","volume":"1","author":"T Toyoshima","year":"2015","unstructured":"Toyoshima T, Tanaka H, Sasaki M, Ichimaru E, Naito Y, Matsushita Y, et al. Accuracy of implant surgery with surgical guide by inexperienced clinicians: an in vitro study. Clin Exp Dent Res. 2015;1:10\u20137.","journal-title":"Clin Exp Dent Res"}],"container-title":["BDJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00295-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00295-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00295-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,26]],"date-time":"2025-01-26T12:52:35Z","timestamp":1737895955000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00295-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,26]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["295"],"URL":"https:\/\/doi.org\/10.1038\/s41405-025-00295-y","relation":{},"ISSN":["2056-807X"],"issn-type":[{"value":"2056-807X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,26]]},"assertion":[{"value":"29 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2024","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 December 2024","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 January 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Before the start of the study, the study protocol was reviewed and approved by the Ethics Committee at the Medical Faculty of the Eberhard Karls University and at the University Hospital of T\u00fcbingen (file reference: 123\/2022BO2). All students participating in the study gave their written informed consent before taking part.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}],"article-number":"6"}}