{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T13:53:12Z","timestamp":1781617992447,"version":"3.54.5"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T00:00:00Z","timestamp":1738281600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T00:00:00Z","timestamp":1738281600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BDJ Open"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objective<\/jats:title>\n            <jats:p>This study aimed to create a 3D-printed customized transfer key and evaluate the accuracy of the virtual patient model with maxillomandibular relationship at centric occlusion using the transfer key.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A 3D-printed transfer key was designed, combining facial and intraoral (IOS) scans. The design included components that recorded the 3D upper and lower arch at centric occlusion. The virtual patient model image was generated in-vitro using a phantom head with soft tissue simulation. Accuracy was assessed by superimposing the 3D scans with reference CBCT images and analyzing trueness and precision using root mean square (RMS) deviations.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The transfer key included an intra-oral part that acts as an anterior deprogrammer to record the relationship of two dental arches at centric occlusion (CO) and an extra-oral with a rotatable cross-shaped design with two arms for locating the facial midline and the two pupils connecting line. Superimposition demonstrated high trueness (RMS: 0.51\u2009mm for the arch regions, 0.69\u2009mm for the whole head region, 0.85\u2009mm in the face region) and precision (RMS: 0.41\u2009mm for the arch regions, 0.52\u2009mm for the entire head, 0.63\u2009mm in the face region) significantly (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). Minimal deviations were observed in critical areas, including the tooth and lip position, indicating that the virtual patient model was closely aligned with the CBCT reference. The dental arches achieved the highest accuracy, while slight deviations were noted in the facial regions.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The 3D-printed customized transfer key effectively enhanced the virtual patient model\u2019s accuracy, surpassing traditional trueness and precision methods. This novel approach offers a streamlined, patient-friendly solution for digital dental workflows.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1038\/s41405-025-00303-1","type":"journal-article","created":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T17:56:37Z","timestamp":1738346197000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["In-vitro accuracy of the virtual patient model with maxillomandibular relationship at centric occlusion using 3D-printed customized transfer key"],"prefix":"10.1038","volume":"11","author":[{"given":"Anh Ho-Quynh","family":"Nguyen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4718-7813","authenticated-orcid":false,"given":"Nam Cong-Nhat","family":"Huynh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Oanh Ngoc-Hoang","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nhat Dinh-Minh","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hai Hoang","family":"Phan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong-Eun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gan","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khanh Hung","family":"Nguyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hung Trong","family":"Hoang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,1,31]]},"reference":[{"key":"303_CR1","doi-asserted-by":"crossref","unstructured":"Avelino MEL, Neves BR, Ribeiro AKC, Carreiro A, Costa RTF, Moraes SLD. Virtual facebow techniques: A scoping review. J Prosthet Dent. 2023. https:\/\/www.thejpd.org\/article\/S0022-3913(23)00572-3\/abstract.","DOI":"10.1016\/j.prosdent.2023.08.032"},{"key":"303_CR2","doi-asserted-by":"crossref","unstructured":"Dawson PE. Functional Occlusion: From TMJ to Smile Design. St. Louis, Missouri: Mosby; 2007.","DOI":"10.4103\/0972-4052.32520"},{"key":"303_CR3","doi-asserted-by":"crossref","unstructured":"The Glossary of Prosthodontic Terms 2023: Tenth Edition. J Prosthet Dent. 2023;130:e1\u2013e3.","DOI":"10.1016\/j.prosdent.2023.03.003"},{"key":"303_CR4","doi-asserted-by":"crossref","unstructured":"S\u00fcl\u00fcn T. Establishing occlusal relationships. Removable Partial Dentures: A Practitioners\u2019 Manual. Cham, Switzerland: Springer; 2024. p. 153\u201367.","DOI":"10.1007\/978-3-031-47083-7_13"},{"key":"303_CR5","doi-asserted-by":"crossref","unstructured":"Revilla-Leon M, Zeitler JM, Kois JC. An overview of the different digital facebow methods for transferring the maxillary cast into the virtual articulator. J Esthet Restor Dent. 2024;36:1675\u201386.","DOI":"10.1111\/jerd.13264"},{"key":"303_CR6","doi-asserted-by":"publisher","first-page":"e678","DOI":"10.4317\/jced.61620","volume":"16","author":"NC Huynh","year":"2024","unstructured":"Huynh NC, Tran AT, Truong TN, Le YT, Tran NC, Tran TT, et al. Correlation of resin composite translucency and IOS accuracy: An in-vitro study. J Clin Exp Dent. 2024;16:e678\u2013e84.","journal-title":"J Clin Exp Dent"},{"key":"303_CR7","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2023.104747","volume":"139","author":"HM Vo","year":"2023","unstructured":"Vo HM, Huynh NC, Tran TT, Hoang HT, Nguyen AT. Influence of titanium dioxide and composite on the accuracy of an intraoral scanner for bilateral upper posterior edentulous jaw (Kennedy class I) scanning: An in vitro study. J Dentistry. 2023;139:104747.","journal-title":"J Dentistry"},{"key":"303_CR8","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2023.104622","volume":"137","author":"C Raffone","year":"2023","unstructured":"Raffone C, Gianfreda F, Antonacci D, Pompeo MG, Bollero P, Canullo L. Chairside virtual patient protocol. Part 3: In vitro accuracy of a digital facebow. J Dentistry. 2023;137:104622.","journal-title":"J Dentistry"},{"key":"303_CR9","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1111\/jopr.13437","volume":"31","author":"JC Kois","year":"2022","unstructured":"Kois JC, Kois DE, Zeitler JM, Martin J. Digital to Analog Facially Generated Interchangeable Facebow Transfer: Capturing a Standardized Reference Position. J Prosthodont. 2022;31:13\u201322.","journal-title":"J Prosthodont"},{"key":"303_CR10","doi-asserted-by":"publisher","first-page":"921","DOI":"10.1016\/j.prosdent.2014.03.021","volume":"112","author":"E Solaberrieta","year":"2014","unstructured":"Solaberrieta E, Otegi JR, Minguez R, Etxaniz O. Improved digital transfer of the maxillary cast to a virtual articulator. J Prosthet Dent. 2014;112:921\u20134.","journal-title":"J Prosthet Dent"},{"key":"303_CR11","doi-asserted-by":"crossref","unstructured":"Ender A, Mehl A. Accuracy in dental medicine, a new way to measure trueness and precision. J Vis Exp. 2014;86:51374.","DOI":"10.3791\/51374"},{"key":"303_CR12","first-page":"201","volume":"26","author":"ND Nguyen","year":"2023","unstructured":"Nguyen ND, Tran NC, Tran TT, Huynh NC, Nguyen KD, Hoang HT, et al. Effects of core buildup composite resin translucency on intraoral scanner accuracy: an in vitro study. Int J Comput Dent. 2023;26:201\u201310.","journal-title":"Int J Comput Dent"},{"key":"303_CR13","doi-asserted-by":"publisher","first-page":"87","DOI":"10.32895\/UMP.MPR.7.4.11","volume":"7","author":"HNM Tran","year":"2023","unstructured":"Tran HNM, Nguyen ATD, Tran TTN, Nguyen KD, Huynh NCN. 3D-printed inlays with different cavity depths impact intraoral-scanner\u2019s accuracy in-vitro. MedPharmRes. 2023;7:87\u201394.","journal-title":"MedPharmRes"},{"key":"303_CR14","doi-asserted-by":"publisher","DOI":"10.1186\/s41205-020-00069-2","volume":"6","author":"T Kamio","year":"2020","unstructured":"Kamio T, Suzuki M, Asaumi R, Kawai T. DICOM segmentation and STL creation for 3D printing: a process and software package comparison for osseous anatomy. 3D Print Med. 2020;6:17.","journal-title":"3D Print Med"},{"key":"303_CR15","doi-asserted-by":"crossref","unstructured":"Faul F, Erdfelder E, Lang AG, Buchner AG. *Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences. Behav Res Methods. 2007;39:175\u201391.","DOI":"10.3758\/BF03193146"},{"key":"303_CR16","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1111\/jopr.13366","volume":"31","author":"J Li","year":"2022","unstructured":"Li J, Chen Z, Decker AM, Wang HL, Joda T, Mendonca G, et al. Trueness and Precision of Economical Smartphone-Based Virtual Facebow Records. J Prosthodont. 2022;31:22\u20139.","journal-title":"J Prosthodont"},{"key":"303_CR17","doi-asserted-by":"crossref","unstructured":"Quinzi V, Polizzi A, Ronsivalle V, Santonocito S, Conforte C, Manenti RJ, et al. Facial Scanning Accuracy with Stereophotogrammetry and Smartphone Technology in Children: A Systematic Review. Children. 2022;9:1390.","DOI":"10.3390\/children9091390"},{"key":"303_CR18","doi-asserted-by":"publisher","first-page":"210","DOI":"10.1067\/mpr.2002.121447","volume":"87","author":"VF Ferrario","year":"2002","unstructured":"Ferrario VF, Sforza C, Serrao G, Schmitz JH. Three-dimensional assessment of the reliability of a postural face-bow transfer. J Prosthet Dent. 2002;87:210\u20135.","journal-title":"J Prosthet Dent"},{"key":"303_CR19","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.prosdent.2022.03.001","volume":"131","author":"N Inoue","year":"2024","unstructured":"Inoue N, Scialabba R, Lee JD, Lee SJ. A comparison of virtually mounted dental casts from traditional facebow records, average values, and 3D facial scans. J Prosthet Dent. 2024;131:136\u201343.","journal-title":"J Prosthet Dent"},{"key":"303_CR20","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1016\/j.prosdent.2021.02.007","volume":"128","author":"X Amezua","year":"2022","unstructured":"Amezua X, Iturrate M, Garikano X, Solaberrieta E. Analysis of the influence of the facial scanning method on the transfer accuracy of a maxillary digital scan to a 3D face scan for a virtual facebow technique: An in vitro study. J Prosthet Dent. 2022;128:1024\u201331.","journal-title":"J Prosthet Dent"},{"key":"303_CR21","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1016\/j.prosdent.2021.10.025","volume":"130","author":"X Amezua","year":"2023","unstructured":"Amezua X, Iturrate M, Garikano X, Solaberrieta E. Analysis of the impact of the facial scanning method on the precision of a virtual facebow record technique: An in vivo study. J Prosthet Dent. 2023;130:382\u201391.","journal-title":"J Prosthet Dent"},{"key":"303_CR22","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1093\/ortho\/29.2.101","volume":"29","author":"RH Samuels","year":"2002","unstructured":"Samuels RH, Brezniak N. Orthodontic facebows: safety issues and current management. J Orthod. 2002;29:101\u20137.","journal-title":"J Orthod"},{"key":"303_CR23","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1016\/j.jcms.2013.09.010","volume":"42","author":"MS Kook","year":"2014","unstructured":"Kook MS, Jung S, Park HJ, Oh HK, Ryu SY, Cho JH, et al. A comparison study of different facial soft tissue analysis methods. J Craniomaxillofac Surg. 2014;42:648\u201356.","journal-title":"J Craniomaxillofac Surg"},{"key":"303_CR24","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1016\/0022-3913(92)90079-P","volume":"67","author":"JF Bowley","year":"1992","unstructured":"Bowley JF, Michaels GC, Lai TW, Lin PP. Reliability of a facebow transfer procedure. J Prosthet Dent. 1992;67:491\u20138.","journal-title":"J Prosthet Dent"},{"key":"303_CR25","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1016\/j.prosdent.2016.05.013","volume":"116","author":"WY Lam","year":"2016","unstructured":"Lam WY, Hsung RT, Choi WW, Luk HW, Pow EH. A 2-part facebow for CAD-CAM dentistry. J Prosthet Dent. 2016;116:843\u20137.","journal-title":"J Prosthet Dent"}],"container-title":["BDJ Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00303-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00303-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00303-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,31]],"date-time":"2025-01-31T17:56:42Z","timestamp":1738346202000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41405-025-00303-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,31]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["303"],"URL":"https:\/\/doi.org\/10.1038\/s41405-025-00303-1","relation":{},"ISSN":["2056-807X"],"issn-type":[{"value":"2056-807X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,31]]},"assertion":[{"value":"12 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2025","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2025","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 January 2025","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The study was approved by the Ethics Committee in Medical Research - University of Medicine and Pharmacy at Ho Chi Minh City (No. 736\/H\u0110\u0110\u0110- \u0110HYD, dated 24\/6\/2024). No consent form was applied for the retro information of the sample.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}}],"article-number":"8"}}