{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,13]],"date-time":"2026-10-13T00:14:41Z","timestamp":1791850481192,"version":"4.3.4"},"reference-count":6,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"},{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springernature.com\/gp\/researchers\/text-and-data-mining"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eur J Clin Nutr"],"published-print":{"date-parts":[[2026,9]]},"DOI":"10.1038\/s41430-026-01780-9","type":"journal-article","created":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T17:36:37Z","timestamp":1782322597000},"page":"986-987","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Beyond reliability: Addressing systematic bias and advancing standardization in bioelectrical impedance analysis"],"prefix":"10.1038","volume":"80","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4980-8353","authenticated-orcid":false,"given":"Adam W.","family":"Potter","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2378-279X","authenticated-orcid":false,"given":"Leigh C.","family":"Ward","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher L.","family":"Chapman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4882-0011","authenticated-orcid":false,"given":"William J.","family":"Tharion","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David P.","family":"Looney","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3134-8427","authenticated-orcid":false,"given":"Karl E.","family":"Friedl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"1780_CR1","unstructured":"La N, Rattanapitoon SK, Thanchonnang C, Rattanapitoon NK. When Precision Becomes Pathology: Stable MFBIA Error as a Hidden Driver of Clinical Misclassification. Eur J Clin Nutr. (in press) 2026."},{"key":"1780_CR2","doi-asserted-by":"publisher","DOI":"10.1038\/s41430-025-01664-4","author":"AW Potter","year":"2025","unstructured":"Potter AW, Ward LC, Chapman CL, Tharion WJ, Looney DP, Friedl KE. Real-world assessment of multi-frequency bioelectrical impedance analysis (MFBIA) for measuring body composition in healthy physically active populations. Eur J Clin Nutr. 2025. https:\/\/doi.org\/10.1038\/s41430-025-01664-4.","journal-title":"Eur J Clin Nutr"},{"key":"1780_CR3","doi-asserted-by":"publisher","DOI":"10.3389\/fnut.2024.1491931","volume":"11","author":"DP Looney","year":"2024","unstructured":"Looney DP, Schafer EA, Chapman CL, Pryor RR, Potter AW, Roberts BM, et al. Reliability, biological variability, and accuracy of multi-frequency bioelectrical impedance analysis for measuring body composition components. Frontiers in Nutrition. 2024;11:1491931.","journal-title":"Frontiers in Nutrition"},{"key":"1780_CR4","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1136\/bmjnph-2022-000512","volume":"5","author":"AW Potter","year":"2022","unstructured":"Potter AW, Nindl LJ, Soto LD, Pazmino A, Looney DP, Tharion WJ, et al. High precision but systematic offset in a standing bioelectrical impedance analysis (BIA) compared with dual-energy X-ray absorptiometry (DXA). BMJ Nutrit Prevent Health. 2022;5:254.","journal-title":"BMJ Nutrit Prevent Health"},{"key":"1780_CR5","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1038\/s41430-018-0335-3","volume":"73","author":"LC Ward","year":"2019","unstructured":"Ward LC. Bioelectrical impedance analysis for body composition assessment: reflections on accuracy, clinical utility, and standardisation. Eur J Clin Nutr. 2019;73:194\u20139.","journal-title":"Eur J Clin Nutr"},{"key":"1780_CR6","doi-asserted-by":"publisher","unstructured":"Bioelectrical impedance analysis in body composition measurement: National Institutes of Health Technology Assessment Conference Statement. Am J Clin Nutr. 1996;64:524S\u201332S. https:\/\/doi.org\/10.1093\/ajcn\/64.3.524S.","DOI":"10.1093\/ajcn\/64.3.524S"}],"container-title":["European Journal of Clinical Nutrition"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41430-026-01780-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41430-026-01780-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41430-026-01780-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T08:38:53Z","timestamp":1788943133000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41430-026-01780-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,24]]},"references-count":6,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9]]}},"alternative-id":["1780"],"URL":"https:\/\/doi.org\/10.1038\/s41430-026-01780-9","relation":{},"ISSN":["0954-3007","1476-5640"],"issn-type":[{"value":"0954-3007","type":"print"},{"value":"1476-5640","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,24]]},"assertion":[{"value":"27 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2026","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 June 2026","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 June 2026","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The opinions or assertions contained herein are the private views of the author(s) and are not to be construed as official or reflecting the views of the Army or the Department of Defense. Any citations of commercial organizations and trade names in this report do not constitute an official Department of the Army endorsement of approval of the products or services of these organizations. Author LCW provides consultancy services to ImpediMed Ltd.; all other authors have no conflicts of interest to declare.","order":1,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Ethics"}}]}}