{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T08:10:29Z","timestamp":1793347829796,"version":"4.5.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2018,3,12]],"date-time":"2018-03-12T00:00:00Z","timestamp":1520812800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1038\/s41433-018-0063-x","type":"journal-article","created":{"date-parts":[[2018,3,8]],"date-time":"2018-03-08T12:40:28Z","timestamp":1520512828000},"page":"1244-1252","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":44,"title":["Accuracy of intraocular lens power calculation using three optical biometry measurement devices: the OA-2000, Lenstar-LS900 and IOLMaster-500"],"prefix":"10.1038","volume":"32","author":[{"given":"Olga","family":"Reitblat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adi","family":"Levy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guy","family":"Kleinmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ehud I.","family":"Assia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,3,12]]},"reference":[{"key":"63_CR1","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.jcrs.2007.10.031","volume":"34","author":"S Norrby","year":"2008","unstructured":"Norrby S. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 2008;34:368\u201376.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR2","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1136\/bjo.2008.156554","volume":"93","author":"PJ Buckhurst","year":"2009","unstructured":"Buckhurst PJ, Wolffsohn JS, Shah S, Naroo SA, Davies LN, Berrow EJ. A new optical low coherence reflectometry device for ocular biometry in cataract patients. Br J Ophthalmol. 2009;93:949\u201353.","journal-title":"Br J Ophthalmol"},{"key":"63_CR3","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1136\/bjo.2008.152736","volume":"93","author":"MP Holzer","year":"2009","unstructured":"Holzer MP, Mamusa M, Auffarth GU. Accuracy of a new partial coherence interferometry analyser for biometric measurements. Br J Ophthalmol. 2009;93:807\u201310.","journal-title":"Br J Ophthalmol"},{"key":"63_CR4","doi-asserted-by":"publisher","first-page":"2387","DOI":"10.1016\/j.jcrs.2015.05.028","volume":"41","author":"S Goebels","year":"2015","unstructured":"Goebels S, Pattm\u00f6ller M, Eppig T, Cayless A, Seitz B, Langenbucher A. Comparison of 3 biometry devices in cataract patients. J Cataract Refract Surg. 2015;41:2387\u201393.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR5","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s40662-016-0059-1","volume":"3","author":"P Kongsap","year":"2016","unstructured":"Kongsap P. Comparison of a new optical biometer and a standard biometer in cataract patients. Eye Vis (Lond, Engl). 2016;3:27.","journal-title":"Eye Vis (Lond, Engl)"},{"key":"63_CR6","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1136\/bjophthalmol-2016-308352","volume":"101","author":"J Huang","year":"2017","unstructured":"Huang J, Savini G, Hoffer KJ, Chen H, Lu W, Hu Q, et al. Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMaster. Br J Ophthalmol. 2017;101:493\u20138.","journal-title":"Br J Ophthalmol"},{"key":"63_CR7","doi-asserted-by":"publisher","first-page":"690","DOI":"10.3928\/1081597X-20170721-05","volume":"33","author":"G Savini","year":"2017","unstructured":"Savini G, Hoffer KJ, Shammas HJ, Aramberri J, Huang J, Barboni P. Accuracy of a new swept-source optical coherence tomography biometer for IOL power calculation and comparison to IOLMaster. J Refract Surg. 2017;33:690\u20135.","journal-title":"J Refract Surg"},{"key":"63_CR8","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","volume":"19","author":"KJ Hoffer","year":"1993","unstructured":"Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg. 1993;19:700\u201312.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR9","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.jcrs.2006.08.054","volume":"33","author":"B Zuberbuhler","year":"2007","unstructured":"Zuberbuhler B, Morrell AJ. Errata in printed Hoffer Q formula. J Cataract Refract Surg. 2007;33:2.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR10","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","volume":"14","author":"JT Holladay","year":"1988","unstructured":"Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruiz RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14:17\u201324.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR11","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","volume":"16","author":"JA Retzlaff","year":"1990","unstructured":"Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK\/T intraocular lens implant power calculation formula. J Cataract Refract Surg. 1990;16:333\u201340.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR12","doi-asserted-by":"publisher","first-page":"389","DOI":"10.1016\/S0886-3350(87)80037-8","volume":"13","author":"GD Barrett","year":"1987","unstructured":"Barrett GD. Intraocular lens calculation formulas for new intraocular lens implants. J Cataract Refract Surg. 1987;13:389\u201396.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR13","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1016\/S0886-3350(13)80339-2","volume":"19","author":"GD Barrett","year":"1993","unstructured":"Barrett GD. An improved universal theoretical formula for intraocular lens power prediction. J Cataract Refract Surg. 1993;19:713\u201320.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR14","unstructured":"Barrett GD. Calculating astigmatic correction. Presented at the XXXIV Congress of the European Society of Cataract and Refractive Surgeons, September 2016, Copenhagen, Denmark."},{"key":"63_CR15","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/S0886-3350(00)00796-3","volume":"27","author":"JT Holladay","year":"2001","unstructured":"Holladay JT, Moran JR, Kezirian GM. Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism. J Cataract Refract Surg. 2001;27:61\u201379.","journal-title":"J Cataract Refract Surg"},{"key":"63_CR16","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307\u201310.","journal-title":"Lancet"},{"key":"63_CR17","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","volume":"85","author":"T Olsen","year":"2007","unstructured":"Olsen T. Calculation of intraocular lens power: a review. Acta Ophthalmol Scand. 2007;85:472\u201385.","journal-title":"Acta Ophthalmol Scand"},{"key":"63_CR18","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.survophthal.2003.10.010","volume":"49","author":"NA Alpins","year":"2004","unstructured":"Alpins NA, Goggin M. Practical astigmatism analysis for refractive outcomes in cataract and refractive surgery. Surv Ophthalmol. 2004;49:109\u201322.","journal-title":"Surv Ophthalmol"}],"container-title":["Eye"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.nature.com\/articles\/s41433-018-0063-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/s41433-018-0063-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.nature.com\/articles\/s41433-018-0063-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,20]],"date-time":"2023-05-20T21:04:06Z","timestamp":1684616646000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41433-018-0063-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3,12]]},"references-count":18,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["63"],"URL":"https:\/\/doi.org\/10.1038\/s41433-018-0063-x","relation":{},"ISSN":["0950-222X","1476-5454"],"issn-type":[{"value":"0950-222X","type":"print"},{"value":"1476-5454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,3,12]]},"assertion":[{"value":"28 October 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 January 2018","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 February 2018","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2018","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"OR received partial travel reimbursement from Tomey Corporation and T.Y.R. SKYMED LTD; AL received travel reimbursement from Hanita Lenses; GK is a consultant of Hanita Lenses; EIA is a consultant of Hanita Lenses.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}