{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T02:08:28Z","timestamp":1792807708700,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2020,8,31]],"date-time":"2020-08-31T00:00:00Z","timestamp":1598832000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,31]],"date-time":"2020-08-31T00:00:00Z","timestamp":1598832000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye"],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objectives<\/jats:title>\n                <jats:p>This comparative study aimed to determine if total keratometry (TK) from IOLMaster 700 could be applied to conventional formulas to perform IOL power calculation in eyes with previous myopic laser refractive surgery, and to evaluate their accuracy with known post-laser refractive surgery formulas.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Sixty-four eyes of 49 patients with previous myopic laser refractive surgery were evaluated 1 month after cataract surgery. A comparison of the prediction error was made between no clinical history post-laser refractive surgery formulas (Barrett True-K, Haigis-L, Shammas-PL) and conventional formulas (EVO, Haigis, Hoffer Q, Holladay I, and SRK\/T) using TK values obtained with the optical biometer IOLMaster 700 (Carl Zeiss Meditec), as well as Barrett True-K with TK.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean prediction error was statistically different from zero for Barrett True-K, Barrett True-K with TK, Haigis-L, Shammas-PL, and Holladay I with TK. The mean absolute error (MAE) was 0.424, 0.671, 0.638, 0.439, 0.408, 0.424, 0.479, 0.647, and 0.524, and median absolute error (MedAE) was 0.388, 0.586, 0.605, 0.298, 0.294, 0.324, 0.333, 0.438, and 0.377 for Barrett True-K, Haigis-L, Shammas-PL, Barrett True-K TK, EVO with TK, Haigis with TK, Hoffer Q with TK, Holladay I with TK, and SRK\/T with TK, respectively. EVO TK followed by Barrett True-K TK and Haigis TK achieved the highest percentages of patients with absolute prediction error within 0.50 and 1.00\u2009D (68.75%, 92.19%, and 64.06%, 92.19%, respectively)<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Formulas combined with TK achieve similar or better results compared to existing no-history post-myopic laser refractive surgery formulas.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1038\/s41433-020-01159-5","type":"journal-article","created":{"date-parts":[[2020,8,31]],"date-time":"2020-08-31T13:06:57Z","timestamp":1598879217000},"page":"1705-1711","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":66,"title":["Accuracy of intraocular lens formulas using total keratometry in eyes with previous myopic laser refractive surgery"],"prefix":"10.1038","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0589-4555","authenticated-orcid":false,"given":"Tun Kuan","family":"Yeo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wee Jin","family":"Heng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Don","family":"Pek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Han Bor","family":"Fam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,8,31]]},"reference":[{"key":"1159_CR1","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1186\/s40662-018-0110-5","volume":"5","author":"G Savini","year":"2018","unstructured":"Savini G, Hoffer KJ. Intraocular lens power calculation in eyes with previous corneal refractive surgery. Eye Vis. 2018;5:18.","journal-title":"Eye Vis"},{"key":"1159_CR2","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","volume":"42","author":"A Abulafia","year":"2016","unstructured":"Abulafia A, Hill WE, Koch DD, Wang L, Barrett GD. Accuracy of the BarrettTrue-K formula for intraocular lens power prediction after laser in situkeratomileusis or photorefractive keratectomy for myopia. J Cataract Refract Surg. 2016;42:363\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR3","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1016\/j.jcrs.2005.12.106","volume":"32","author":"S Masket","year":"2006","unstructured":"Masket S, Masket SE. Simple regression formula for intraocular lens poweradjustment in eyes requiring cataract surgery after excimer laser photoablation. J Cataract Refract Surg. 2006;32:430\u20134.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR4","doi-asserted-by":"publisher","first-page":"1455","DOI":"10.1016\/j.jcrs.2010.02.029","volume":"36","author":"G Savini","year":"2010","unstructured":"Savini G, Hoffer KJ, Carbonelli M, Barboni P. Intraocular lens powercalculation after myopic excimer laser surgery: clinical comparison of publishedmethods. J Cataract Refract Surg. 2010;36:1455\u201365.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR5","doi-asserted-by":"publisher","first-page":"2063","DOI":"10.1016\/S0886-3350(03)00957-X","volume":"29","author":"J Aramberri","year":"2003","unstructured":"Aramberri J. Intraocular lens power calculation after corneal refractivesurgery: double-K method. J Cataract Refract Surg. 2003;29:2063\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR6","doi-asserted-by":"publisher","first-page":"2004","DOI":"10.1016\/j.jcrs.2006.08.037","volume":"32","author":"E Borasio","year":"2006","unstructured":"Borasio E, Stevens J, Smith GT. Estimation of true corneal power afterkeratorefractive surgery in eyes requiring cataract surgery: BESSt formula. J Cataract Refract Surg. 2006;32:2004\u201314.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR7","doi-asserted-by":"publisher","first-page":"1658","DOI":"10.1016\/j.jcrs.2008.06.029","volume":"34","author":"W Haigis","year":"2008","unstructured":"Haigis W. Intraocular lens calculation after refractive surgery for myopia:Haigis-L formula. J Cataract Refract Surg. 2008;34:1658\u201363.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR8","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.jcrs.2006.08.045","volume":"33","author":"HJ Shammas","year":"2007","unstructured":"Shammas HJ, Shammas MC. No-history method of intraocular lens powercalculation for cataract surgery after myopic laser in situ keratomileusis. J Cataract Refract Surg. 2007;33:31\u20136.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR9","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.jcrs.2014.05.040","volume":"41","author":"R Potvin","year":"2015","unstructured":"Potvin R, Hill W. New algorithm for intraocular lens power calculations aftermyopic laser in situ keratomileusis based on rotating Scheimpflug camera data. J Cataract Refract Surg. 2015;41:339\u201347.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR10","doi-asserted-by":"publisher","first-page":"2443","DOI":"10.1016\/j.ophtha.2015.08.037","volume":"122","author":"L Wang","year":"2015","unstructured":"Wang L, Tang M, Huang D, Weikert MP, Koch DD. Comparison of newer intraocular lens power calculation methods for eyes after corneal refractive surgery. Ophthalmology. 2015;122:2443\u20139.","journal-title":"Ophthalmology"},{"key":"1159_CR11","doi-asserted-by":"publisher","first-page":"54","DOI":"10.3928\/1081597X-20181119-01","volume":"35","author":"V Vrijman","year":"2019","unstructured":"Vrijman V, Abulafia A, van der Linden JW, van der Meulen IJE, Mourits MP, Lapid-Gortzak R. Evaluation of different IOL calculation formulas of the ASCRScalculator in eyes after corneal refractive laser surgery for myopia withmultifocal IOL implantation. J Refract Surg. 2019;35:54\u20139.","journal-title":"J Refract Surg"},{"key":"1159_CR12","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1016\/S0886-3350(99)00327-2","volume":"26","author":"H Gimbel","year":"2000","unstructured":"Gimbel H, Sun R, Kaye GB. Refractive error in cataract surgery after previous refractive surgery. J Cataract Refract Surg. 2000;26:142\u20134.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR13","doi-asserted-by":"publisher","first-page":"331","DOI":"10.3928\/1081597X-20180214-02","volume":"34","author":"BR LaHood","year":"2018","unstructured":"LaHood BR, Goggin M. Measurement of posterior corneal astigmatism by the IOLMaster 700. J Refract Surg. 2018;34:331\u20136.","journal-title":"J Refract Surg"},{"key":"1159_CR14","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1136\/bjophthalmol-2015-307779","volume":"100","author":"A Akman","year":"2016","unstructured":"Akman A, Asena L, Gungor SG. Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500. Br J Ophthalmol. 2016;100:1201\u20135.","journal-title":"Br J Ophthalmol"},{"key":"1159_CR15","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1016\/j.jcrs.2018.11.029","volume":"45","author":"G Savini","year":"2019","unstructured":"Savini G, Abbate R, Hoffer KJ, Mularoni A, Imburgia A, Avoni L, et al. Intraocular lens power calculation in eyes with keratoconus. J Cataract Refract Surg. 2019;45:576\u201381.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR16","doi-asserted-by":"publisher","first-page":"2080","DOI":"10.1016\/j.jcrs.2012.08.036","volume":"38","author":"DD Koch","year":"2012","unstructured":"Koch DD, Ali SF, Weikert MP, Shirayama M, Jenkins R, Wang L. Contribution of posterior corneal astigmatism to total corneal astigmatism. J Cataract Refract Surg. 2012;38:2080\u20137.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR17","doi-asserted-by":"publisher","first-page":"497","DOI":"10.3341\/kjo.2018.0008","volume":"32","author":"K Cho","year":"2018","unstructured":"Cho K, Lim DH, Yang CM, Chung ES, Chung TY. Comparison of intraocular lens power calculation methods following myopic laser refractive surgery: new options using a rotating Scheimpflug camera. Korean J Ophthalmol. 2018;32:497\u2013505.","journal-title":"Korean J Ophthalmol"},{"key":"1159_CR18","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s004170000188","volume":"238","author":"W Haigis","year":"2000","unstructured":"Haigis W, Lege B, Miller N, Schneider B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch Clin Exp Ophthalmol. 2000;238:765\u201373.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"1159_CR19","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","volume":"19","author":"KJ Hoffer","year":"1993","unstructured":"Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg. 1993;19:700\u201312.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR20","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","volume":"14","author":"JT Holladay","year":"1988","unstructured":"Holladay JT, Prager TC, Chandler TY, Musgrove KH, Lewis JW, Ruiz RS. A three-part system for refining intraocular lens power calculations. J Cataract Refract Surg. 1988;14:17\u201324.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR21","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","volume":"16","author":"JA Retzlaff","year":"1990","unstructured":"Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK\/T intraocular lens power calculation formula. J Cataract Refract Surg. 1990;16:333\u201340.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR22","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1016\/j.ophtha.2019.04.011","volume":"126","author":"RB Melles","year":"2019","unstructured":"Melles RB, Kane JX, Olsen T, Chang WJ. Update on intraocular lens calculation formulas. Ophthalmology. 2019;126:1334\u20135.","journal-title":"Ophthalmology"},{"key":"1159_CR23","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1097\/j.jcrs.0000000000000205","volume":"46","author":"G Savini","year":"2020","unstructured":"Savini G, Hoffer KJ, Balducci N, Barboni P, Schiano-Lomoriello D. Comparisonof formula accuracy for intraocular lens power calculation based on measurementsby a swept-source optical coherence tomography optical biometer. J Cataract Refract Surg. 2020;46:27\u201333.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR24","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1016\/j.jcrs.2019.05.020","volume":"45","author":"L Wang","year":"2019","unstructured":"Wang L, Spektor T, de Souza RG, Koch DD. Evaluation of total keratometry and its accuracy for IOL power calculation in eyes following corneal refractive surgery. J Cataract Refract Surg. 2019;45:1416\u201321.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR25","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1016\/j.jcrs.2014.06.034","volume":"41","author":"CW Wong","year":"2015","unstructured":"Wong CW, Yuen L, Tseng P, Han DC. Outcomes of the Haigis-L formula for calculating intraocular lens power in Asian eyes after refractive surgery. J Cataract Refract Surg. 2015;41:607\u201312.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR26","doi-asserted-by":"publisher","first-page":"940","DOI":"10.1016\/j.ophtha.2010.08.048","volume":"118","author":"M McCarthy","year":"2011","unstructured":"McCarthy M, Gavanski GM, Paton KE, Holland SP. Intraocular lens power calculations after myopic laser refractive surgery: a comparison of methods in 173 eyes. Ophthalmology. 2011;118:940\u20134.","journal-title":"Ophthalmology"},{"key":"1159_CR27","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1016\/j.jcrs.2010.03.044","volume":"36","author":"L Wang","year":"2010","unstructured":"Wang L, Hill WE, Koch DD. Evaluation of intraocular lens power prediction methods using the American Society of Cataract and Refractive Surgeons post-keratorefractive intraocular lens power calculator. J Cataract Refract Surg. 2010;36:1466\u201373.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR28","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1016\/j.jcrs.2015.12.005","volume":"42","author":"X Chen","year":"2016","unstructured":"Chen X, Yuan F, Wu L. Metaanalysis of intraocular lens power calculation after laser refractive surgery in myopic eyes. J Cataract Refract Surg. 2016;42:163\u201370.","journal-title":"J Cataract Refract Surg"},{"key":"1159_CR29","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1097\/ICO.0b013e31829e1eb5","volume":"32","author":"VJ Camps","year":"2013","unstructured":"Camps VJ, Pi\u00f1ero DP, Mateo V, Ribera D, de Fez D, Blanes-Momp\u00f3 FJ, et al. Algorithm for correcting the keratometric error in the estimation of the corneal power in eyes with previous myopic laser refractive surgery. Cornea. 2013;32:1454\u20139.","journal-title":"Cornea"},{"key":"1159_CR30","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1016\/j.jcrs.2012.10.044","volume":"39","author":"M Saiki","year":"2013","unstructured":"Saiki M, Negishi K, Kato N, Ogino R, Arai H, Toda I, et al. Modified double-K method for intraocular lens power calculation after excimer laser corneal refractive surgery. J Cataract Refract Surg. 2013;39:556\u201362.","journal-title":"J Cataract Refract Surg"}],"container-title":["Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41433-020-01159-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41433-020-01159-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41433-020-01159-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,30]],"date-time":"2021-08-30T23:15:35Z","timestamp":1630365335000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41433-020-01159-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,31]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["1159"],"URL":"https:\/\/doi.org\/10.1038\/s41433-020-01159-5","relation":{},"ISSN":["0950-222X","1476-5454"],"issn-type":[{"value":"0950-222X","type":"print"},{"value":"1476-5454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,31]]},"assertion":[{"value":"9 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 August 2020","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 August 2020","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 August 2020","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}