{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T12:07:41Z","timestamp":1791288461719,"version":"4.3.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T00:00:00Z","timestamp":1641945600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T00:00:00Z","timestamp":1641945600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000272","name":"DH | National Institute for Health Research","doi-asserted-by":"publisher","award":["CL-2017-11-003"],"award-info":[{"award-number":["CL-2017-11-003"]}],"id":[{"id":"10.13039\/501100000272","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Eye"],"published-print":{"date-parts":[[2023,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background\/objectives<\/jats:title>\n                <jats:p>Handheld fundus cameras are portable and cheaper alternatives to table-top counterparts. To date there have been no studies comparing feasibility and clinical utility of handheld fundus cameras to table-top devices. We compare the feasibility and clinical utility of four handheld fundus cameras\/retinal imaging devices (Remidio NMFOP, Volk Pictor Plus, Volk iNview, oDocs visoScope) to a table-top camera (Zeiss Visucam<jats:sup>NM\/FA<\/jats:sup>).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Subjects\/methods<\/jats:title>\n                <jats:p>Healthy participants (<jats:italic>n<\/jats:italic>\u2009=\u200910, mean age\u2009\u00b1\u2009SD = 21.0\u2009\u00b1\u20090.9 years) underwent fundus photography with five devices to assess success\/failure rates of image acquisition. Participants with optic disc abnormalities (<jats:italic>n<\/jats:italic>\u2009=\u20098, mean age\u2009\u00b1\u2009SD\u2009=\u200926.8\u2009\u00b1\u200915.9) and macular abnormalities (<jats:italic>n<\/jats:italic>\u2009=\u200910, mean age\u2009\u00b1\u2009SD\u2009=\u200971.6\u2009\u00b1\u200915.4) underwent imaging with the top three scoring fundus cameras. Images were randomised and subsequently validated by ophthalmologists masked to the diagnoses and devices used.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Image acquisition success rates (100%) were achieved in non-mydriatic and mydriatic settings for Zeiss, Remidio and Pictor, compared with lower success rates for iNview and oDocs. Image quality and gradeability were significantly higher for Zeiss, Remidio and Pictor (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001) compared to iNview and oDocs. For cup:disc ratio estimates, similar levels of bias were seen for Zeiss (\u22120.09\u2009\u00b1\u2009SD:0.15), Remidio (\u22120.07\u2009\u00b1\u2009SD:0.14) and Pictor (\u22120.05\u2009\u00b1\u2009SD:0.16). Diagnostic sensitivities were highest for Zeiss (84.9%; 95% CI, 78.2\u201391.5%) followed by Pictor (78.1%; 95% CI, 66.6\u201389.5%) and Remidio (77.5%; 95% CI, 65.9\u201389.0%).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Remidio and Pictor achieve comparable results to the Zeiss table-top camera. Both devices achieved similar scores in feasibility, image quality, image gradeability and diagnostic sensitivity. This suggests that these devices potentially offer a more cost-effective alternative in certain clinical scenarios.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1038\/s41433-021-01926-y","type":"journal-article","created":{"date-parts":[[2022,1,12]],"date-time":"2022-01-12T13:03:16Z","timestamp":1641992596000},"page":"274-279","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Feasibility and clinical utility of handheld fundus cameras for retinal imaging"],"prefix":"10.1038","volume":"37","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3039-6336","authenticated-orcid":false,"given":"Susmit","family":"Das","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helen J.","family":"Kuht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ian","family":"De Silva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sundeep S.","family":"Deol","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lina","family":"Osman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joyce","family":"Burns","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nagini","family":"Sarvananthan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Usman","family":"Sarodia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bharat","family":"Kapoor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tahir","family":"Islam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raghavan","family":"Sampath","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6098-3761","authenticated-orcid":false,"given":"Alicia","family":"Poyser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5219-5805","authenticated-orcid":false,"given":"Vasileios","family":"Konidaris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rossella","family":"Anzidei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank A.","family":"Proudlock","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4630-1234","authenticated-orcid":false,"given":"Mervyn G.","family":"Thomas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,12]]},"reference":[{"key":"1926_CR1","doi-asserted-by":"publisher","first-page":"e373","DOI":"10.1212\/WNL.0000000000004895","volume":"90","author":"V Sachdeva","year":"2018","unstructured":"Sachdeva V, Vasseneix C, Hage R, Bidot S, Clough LC, Wright DW, et al. Optic nerve head edema among patients presenting to the emergency department. Neurology. 2018;90:e373\u20139.","journal-title":"Neurology"},{"key":"1926_CR2","doi-asserted-by":"publisher","first-page":"2402","DOI":"10.1001\/jama.2016.17216","volume":"316","author":"V Gulshan","year":"2016","unstructured":"Gulshan V, Peng L, Coram M, Stumpe MC, Wu D, Narayanaswamy A, et al. Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs. JAMA. 2016;316:2402\u201310.","journal-title":"JAMA"},{"key":"1926_CR3","doi-asserted-by":"publisher","unstructured":"Li B, Chen H, Zhang B, Yuan M, Jin X, Lei B, et al. Development and evaluation of a deep learning model for the detection of multiple fundus diseases based on colour fundus photography. Br J Ophthalmol. 2021. https:\/\/doi.org\/10.1136\/bjophthalmol-2020-316290.","DOI":"10.1136\/bjophthalmol-2020-316290"},{"key":"1926_CR4","doi-asserted-by":"publisher","unstructured":"Milea D, Najjar RP, Jiang Z, Ting D, Vasseneix C, Xu X, et al. Artificial intelligence to detect papilledema from ocular fundus photographs. N. Engl J Med. 2020;382:1687\u201395. https:\/\/doi.org\/10.1056\/NEJMoa1917130.","DOI":"10.1056\/NEJMoa1917130"},{"key":"1926_CR5","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1089\/tmj.2015.0068","volume":"22","author":"N Panwar","year":"2016","unstructured":"Panwar N, Huang P, Lee J, Keane PA, Chuan TS, Richhariya A, et al. Fundus photography in the 21st century\u2014a review of recent technological advances and their implications for worldwide healthcare. Telemed J e-Health. 2016;22:198.","journal-title":"Telemed J e-Health"},{"key":"1926_CR6","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1007\/s40135-018-0162-7","volume":"6","author":"A Barikian","year":"2018","unstructured":"Barikian A, Haddock LJ. Smartphone assisted fundus fundoscopy\/photography. Curr Ophthalmol Rep. 2018;6:46\u201352.","journal-title":"Curr Ophthalmol Rep"},{"key":"1926_CR7","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1109\/RBME.2010.2084567","volume":"3","author":"MD Abr\u00e0moff","year":"2010","unstructured":"Abr\u00e0moff MD, Garvin MK, Sonka M. Retinal imaging and image analysis. IEEE Rev Biomed Eng. 2010;3:169\u2013208.","journal-title":"IEEE Rev Biomed Eng"},{"key":"1926_CR8","unstructured":"Remidio. Remidio. NM Fundus On Phone (NMFOP). Available at: https:\/\/www.remidio.us\/fop.php. Accessed 11\/05\/2020."},{"key":"1926_CR9","unstructured":"Remidio. Remidio. The technology inside the world\u2019s first smartphone based non mydriatic retinal imaging device. Available at: https:\/\/www.remidio.us\/smartphone_retinal_imaging.php. Accessed 11\/05\/2020."},{"key":"1926_CR10","unstructured":"Remidio. Remidio. Fundus-on-phone non-mydriatic brochure. 2019; Available at: https:\/\/www.remidio.us\/images\/FOP_NM-10_Brochure.pdf. Accessed 30\/09\/21."},{"key":"1926_CR11","unstructured":"Volk. Volk. User\u2019s manual volk pictor plus digital imaging device. Available at: https:\/\/www.volk.com\/pages\/portable-cameras-instructions-for-use. Accessed 06\/08\/2020."},{"key":"1926_CR12","unstructured":"VOLK. Pictor Plus\u2122 Fundus Camera. Available at: https:\/\/www.volk.com\/products\/pictor-plus-fundus-camera. Accessed 11\/05\/2021."},{"key":"1926_CR13","unstructured":"Volk. Volk. User\u2019s manual\/instructions for use Volk iNview Retinal Camera. Available at: https:\/\/www.volk.com\/pages\/portable-cameras-instructions-for-use. Accessed 06\/08\/2020."},{"key":"1926_CR14","unstructured":"Volk. User\u2019s manual\/instructions for use Volk iNview Retinal Camera. 2016; Available at: https:\/\/www.topcon.ca\/wp-content\/uploads\/2017\/06\/IM-088-Volk-iNview-Instruction-Manual-English.pdf. Accessed 30\/09\/21."},{"key":"1926_CR15","unstructured":"Yang K, Yang K. Kaixi Yang -oDocs Eye Care. Available at: https:\/\/kaixiyang.com\/odocs-eye-care. Accessed 11\/05\/2020."},{"key":"1926_CR16","unstructured":"oDocs. visoScope 2.0. Available at: https:\/\/odocseyecare.shop\/products\/visoscope-2-0. Accessed 30\/09\/2021."},{"key":"1926_CR17","unstructured":"Mart\u00ednez-Aguirre IR, Dorville YL, Maroto JMA, S\u00e1nchez MT, Zarzosa ME, Benito FJJ. Smartphones for ophthalmic fundus imaging: a review. 2017."},{"key":"1926_CR18","unstructured":"Zeiss. Zeiss. VISUCAM NM\/FA - Fundus Imaging - Retina - Medical Technology | ZEISS United States. Available at: https:\/\/www.zeiss.com\/meditec\/us\/products\/ophthalmology-optometry\/retina\/diagnostics\/fundus-imaging\/visucam-nm-fa.html. Accessed 05\/05\/2020."},{"key":"1926_CR19","unstructured":"Zeiss. VISUCAM Fundus Imaging from ZEISS. 2017; Available at: https:\/\/www.zeiss.com\/content\/dam\/Meditec\/us\/brochures\/visucam_fundus_imaging_en_31_022_0024ii-us_31_022_0024ii.pdf. Accessed 30\/09\/21."},{"key":"1926_CR20","unstructured":"DOTmed. DOTmed. Used CARL ZEISS Visucam NMFA non mydriatic digital fundus camera fluorescein fundus camera for sale - DOTmed Listing #2934021: Available at: https:\/\/www.dotmed.com\/listing\/fundus-camera\/carl-zeiss\/visucam-nmfa-non-mydriatic-digital-fundus-camera-fluorescein\/2934021\/. Accessed 09\/08\/2020."},{"key":"1926_CR21","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1212\/WNL.0000000000005480","volume":"90","author":"S Zafar","year":"2018","unstructured":"Zafar S, Cardenas YM, Leishangthem L, Yaddanapudi S. Opinion and special articles: amateur fundus photography with various new devices: Our experience as neurology residents. Neurology. 2018;90:897\u2013901.","journal-title":"Neurology"},{"key":"1926_CR22","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.oret.2018.09.016","volume":"3","author":"S Sengupta","year":"2019","unstructured":"Sengupta S, Sindal MD, Baskaran P, Pan U, Venkatesh R. Sensitivity and specificity of smartphone-based retinal imaging for diabetic retinopathy: a comparative study. Ophthalmol Retin. 2019;3:146\u201353.","journal-title":"Ophthalmol Retin"},{"key":"1926_CR23","first-page":"1426","volume":"56","author":"W Zhang","year":"2015","unstructured":"Zhang W, Nicholas P, Schuman S, Allingham M, Faridi A, Tushar S, et al. Screening for diabetic retinopathy using the hand-held PICTOR Camera. Invest Ophthalmol Vis Sci. 2015;56:1426.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1926_CR24","doi-asserted-by":"publisher","first-page":"1138","DOI":"10.1038\/s41433-018-0064-9","volume":"32","author":"R Rajalakshmi","year":"2018","unstructured":"Rajalakshmi R, Subashini R, Anjana RM, Mohan V. Automated diabetic retinopathy detection in smartphone-based fundus photography using artificial intelligence. Eye (Lond). 2018;32:1138\u201344.","journal-title":"Eye (Lond)"},{"key":"1926_CR25","first-page":"1645","volume":"61","author":"ES Barriga","year":"2020","unstructured":"Barriga ES, Dewi ER, Baldivieso O, Borda J, Diaz C, Rahimy E, et al. Using a handheld retinal camera and artificial intelligence for diabetic retinopathy screening in Bolivia. Invest Ophthalmol Vis Sci. 2020;61:1645\u201345.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1926_CR26","first-page":"476","volume":"61","author":"P Soliz","year":"2020","unstructured":"Soliz P, Zamora G, Aslan J, Nemeth SC, Benson J, Burgess P. Impact of artificial intelligence for diabetic retinopathy screening in a Malawi, Africa Clinic. Invest Ophthalmol Vis Sci. 2020;61:476.","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"1926_CR27","doi-asserted-by":"crossref","unstructured":"Waisbourd M, Bond EA, Sullivan T, Hu WD, Shah SB, Molineaux J, et al. Evaluation of nonmydriatic hand-held optic disc photography grading in the Philadelphia glaucoma detection and treatment project. J Glaucoma. 2016;25:e520\u20135.","DOI":"10.1097\/IJG.0000000000000382"},{"key":"1926_CR28","doi-asserted-by":"publisher","first-page":"1307","DOI":"10.1038\/s41433-020-0822-3","volume":"34","author":"R Kaur","year":"2020","unstructured":"Kaur R, Singh H, Samria S, Kumar N, Parachuri N, Sharma R, et al. MII RetCam assisted smartphone-based fundus imaging (MSFI)-A boon for paediatric retinal imaging. Eye (Lond). 2020;34:1307\u20139.","journal-title":"Eye (Lond)"}],"updated-by":[{"DOI":"10.1038\/s41433-022-02041-2","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2022,5,25]],"date-time":"2022-05-25T00:00:00Z","timestamp":1653436800000}}],"container-title":["Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41433-021-01926-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41433-021-01926-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41433-021-01926-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,24]],"date-time":"2023-01-24T10:07:27Z","timestamp":1674554847000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41433-021-01926-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,12]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["1926"],"URL":"https:\/\/doi.org\/10.1038\/s41433-021-01926-y","relation":{"correction":[{"id-type":"doi","id":"10.1038\/s41433-022-02041-2","asserted-by":"object"}]},"ISSN":["0950-222X","1476-5454"],"issn-type":[{"value":"0950-222X","type":"print"},{"value":"1476-5454","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,12]]},"assertion":[{"value":"4 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 December 2021","order":2,"name":"revised","label":"Revised","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 December 2021","order":3,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 January 2022","order":4,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2022","order":5,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":6,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1038\/s41433-022-02041-2","URL":"https:\/\/doi.org\/10.1038\/s41433-022-02041-2","order":8,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}]}}